1.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
2.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
3.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
4.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
5.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
6.Pembrolizumab for Patients with Relapsed or Refractory Extranodal NK/T-Cell Lymphoma in Korea
Ji Yun LEE ; Ji Hyun KWON ; Joon Young HUR ; Jun Ho YI ; Ji Hyun LEE ; Hyungwoo CHO ; Young Rok DO ; Jae-Cheol JO ; Hye Jin KANG ; Yougil KOH ; Won Sik LEE ; Sung Nam LIM ; Sang Eun YOON ; Seok Jin KIM ; Jeong-Ok LEE
Cancer Research and Treatment 2024;56(2):681-687
Purpose:
Programmed death-1 blockade with pembrolizumab has shown promising activity in relapsed/refractory (R/R) extranodal natural killer/T-cell lymphoma (NKTCL), but studies are limited, with small patient numbers.
Materials and Methods:
Thirteen institutes involved with the Consortium for Improving Survival of Lymphoma, a Korean lymphoma study group, collected the clinical data of 59 patients treated with pembrolizumab as salvage therapy between 2016 and 2022.
Results:
The median age of the patients was 60 years (range, 22 to 87 years), and 76.3% had advanced Ann Abor stage disease. Pembrolizumab was given to 35.6%, 40.7%, and 23.7% of the patients as second-, third-, and fourth- or higher-line chemotherapy, respectively. The overall response rate was 40.7%, with 28.8% having complete response. The estimated 2-year progression-free survival (PFS) and overall survival rates for all patients were 21.5% and 28.7%, respectively; for responders, the rates were 53.0% and 60.7%, respectively. Although not statistically significant, Eastern Cooperative Oncology Group performance status ≥ 2 (hazard ratio [HR], 1.91; 95% confidence interval [95% CI], 0.93 to 3.94; p=0.078) and stage III or IV disease (HR, 2.59; 95% CI, 0.96 to 6.96; p=0.060) were associated with a trend toward shorter PFS in multivariate analysis. Grade 3 or 4 adverse events (AEs) were noted in 12 patients (20.3%); neutropenia (10.2%), fatigue (6.8%), and pneumonitis (5.1%) were most common AEs.
Conclusion
In conclusion, while pembrolizumab had a modest effect on patients with R/R NKTCL, it may be a useful salvage therapy for patients with localized disease and good performance status.
7.Transradial Versus Transfemoral Access for Bifurcation Percutaneous Coronary Intervention Using SecondGeneration Drug-Eluting Stent
Jung-Hee LEE ; Young Jin YOUN ; Ho Sung JEON ; Jun-Won LEE ; Sung Gyun AHN ; Junghan YOON ; Hyeon-Cheol GWON ; Young Bin SONG ; Ki Hong CHOI ; Hyo-Soo KIM ; Woo Jung CHUN ; Seung-Ho HUR ; Chang-Wook NAM ; Yun-Kyeong CHO ; Seung Hwan HAN ; Seung-Woon RHA ; In-Ho CHAE ; Jin-Ok JEONG ; Jung Ho HEO ; Do-Sun LIM ; Jong-Seon PARK ; Myeong-Ki HONG ; Joon-Hyung DOH ; Kwang Soo CHA ; Doo-Il KIM ; Sang Yeub LEE ; Kiyuk CHANG ; Byung-Hee HWANG ; So-Yeon CHOI ; Myung Ho JEONG ; Hyun-Jong LEE
Journal of Korean Medical Science 2024;39(10):e111-
Background:
The benefits of transradial access (TRA) over transfemoral access (TFA) for bifurcation percutaneous coronary intervention (PCI) are uncertain because of the limited availability of device selection. This study aimed to compare the procedural differences and the in-hospital and long-term outcomes of TRA and TFA for bifurcation PCI using secondgeneration drug-eluting stents (DESs).
Methods:
Based on data from the Coronary Bifurcation Stenting Registry III, a retrospective registry of 2,648 patients undergoing bifurcation PCI with second-generation DES from 21 centers in South Korea, patients were categorized into the TRA group (n = 1,507) or the TFA group (n = 1,141). After propensity score matching (PSM), procedural differences, in-hospital outcomes, and device-oriented composite outcomes (DOCOs; a composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) were compared between the two groups (772 matched patients each group).
Results:
Despite well-balanced baseline clinical and lesion characteristics after PSM, the use of the two-stent strategy (14.2% vs. 23.7%, P = 0.001) and the incidence of in-hospital adverse outcomes, primarily driven by access site complications (2.2% vs. 4.4%, P = 0.015), were significantly lower in the TRA group than in the TFA group. At the 5-year follow-up, the incidence of DOCOs was similar between the groups (6.3% vs. 7.1%, P = 0.639).
Conclusion
The findings suggested that TRA may be safer than TFA for bifurcation PCI using second-generation DESs. Despite differences in treatment strategy, TRA was associated with similar long-term clinical outcomes as those of TFA. Therefore, TRA might be the preferred access for bifurcation PCI using second-generation DES.
8.A machine learning-based approach for predicting renal function recovery in general ward patients with acute kidney injury
Nam-Jun CHO ; Inyong JEONG ; Yeongmin KIM ; Dong Ok KIM ; Se-Jin AHN ; Sang-Hee KANG ; Hyo-Wook GIL ; Hwamin LEE
Kidney Research and Clinical Practice 2024;43(4):538-547
Acute kidney injury (AKI) is a significant challenge in healthcare. While there are considerable researches dedicated to AKI patients, a crucial factor in their renal function recovery, is often overlooked. Thus, our study aims to address this issue through the development of a machine learning model to predict restoration of kidney function in patients with AKI. Methods: Our study encompassed data from 350,345 cases, derived from three hospitals. AKI was classified in accordance with the Kidney Disease: Improving Global Outcomes. Criteria for recovery were established as either a 33% decrease in serum creatinine levels at AKI onset, which was initially employed for the diagnosis of AKI. We employed various machine learning models, selecting 43 pertinent features for analysis. Results: Our analysis contained 7,041 and 2,929 patients’ data from internal cohort and external cohort respectively. The Categorical Boosting Model demonstrated significant predictive accuracy, as evidenced by an internal area under the receiver operating characteristic (AUROC) of 0.7860, and an external AUROC score of 0.7316, thereby confirming its robustness in predictive performance. SHapley Additive exPlanations (SHAP) values were employed to explain key factors impacting recovery of renal function in AKI patients. Conclusion: This study presented a machine learning approach for predicting renal function recovery in patients with AKI. The model performance was assessed across distinct hospital settings, which revealed its efficacy. Although the model exhibited favorable outcomes, the necessity for further enhancements and the incorporation of more diverse datasets is imperative for its application in real- world.
9.Cancer risk in patients with Peutz-Jeghers syndrome in Korea: a retrospective multi-center study
Su Hwan KIM ; Eun Ran KIM ; Jae Jun PARK ; Eun Sun KIM ; Hyeon Jeong GOONG ; Kyeong Ok KIM ; Ji Hyung NAM ; Yehyun PARK ; Sang Pyo LEE ; Hyun Joo JANG ; ;
The Korean Journal of Internal Medicine 2023;38(2):176-185
Background/Aims:
There have been little research on the cancer risks of patients with Peutz-Jeghers syndrome (PJS) in Korea. We aimed to investigate the clinical features of PJS patients and their cancer incidence rate.
Methods:
Patients with PJS from nine medical centers were enrolled. In those patients diagnosed with cancer, data obtained included the date of cancer diagnosis, the tumor location, and the cancer stage. The cumulative risks of gastrointestinal cancers and extra-gastrointestinal cancers were calculated using the Kaplan-Meier method.
Results:
A total of 96 PJS patients were included. The median age at diagnosis of PJS was 23.4 years. Cancer developed in 21 of the 96 patients (21.9%). The age of PJS diagnosis was widely distributed (0.9 to 72.4 years). The most common cancers were gastrointestinal cancer (n = 12) followed by breast cancer (n = 6). The cumulative lifetime cancer risk was calculated to be 62.1% at age 60. The cumulative lifetime gastrointestinal cancer risk was 47.1% at age 70. The cumulative lifetime extra- gastrointestinal cancer risk was 40.3% at age 60.
Conclusions
PJS onset may occur at any age and the risks of gastrointestinal and extra-gastrointestinal cancer are high. Thorough surveillance of PJS patients for malignancies is vital.
10.Utilization of an Artificial Intelligence Program Using the Greulich-Pyle Method to Evaluate Bone Age in the Skeletal Maturation Stage
Jihoon KIM ; Hyejun SEO ; Soyoung PARK ; Eungyung LEE ; Taesung JEONG ; Ok Hyung NAM ; Sungchul CHOI ; Jonghyun SHIN
Journal of Korean Academy of Pediatric Dentistry 2023;50(1):89-103
The purpose of this study was to measure bone age using an artificial intelligence program based on the Greulich-Pyle (GP) method to find out the bone age corresponding to each stage of cervical vertebral maturation (CVM) and the middle phalanx of the third finger (MP3). This study was conducted on 3,118 patients who visited pediatric dentistry at Kyung Hee University Dental Hospital and Pusan National University Dental Hospital from 2013 to 2021. The CVM stage was divided into 5 stages according to the classification by Baccetti, and the MP3 stage was divided into 5 stages according to the methods of Hägg and Taranger. Based on the GP method, bone age was evaluated using an artificial intelligence program. The pubertal growth spurt in the CVM stage was CVM II and III. The mean bone age in CVM II was 11.00 ± 1.81 years for males and 10.00 ± 1.49 years for females, and in CVM III, 13.00 ± 1.46 years for males and 12.00 ± 1.44 years for females (p < 0.0001). The pubertal growth spurt in the MP3 stage was MP3 - G stage. The bone age at the MP3 - G stage was 13.14 ± 1.07 years for males and 11.40 ± 1.09 years for females (p < 0.0001). Bone age evaluation using artificial intelligence is worth using in clinical practice, and it is expected that a faster and more accurate diagnosis will be possible.

Result Analysis
Print
Save
E-mail