1.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
2.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
3.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
4.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
5.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
6.Central Anticholinergic Syndrome Induced by Atropine Eye Drops: A Case Report
Jung Sun HEO ; Je Jin LEE ; Sang Uk CHOI ; Nam Ju MOON ; Joon Hyung YEO
Journal of the Korean Ophthalmological Society 2024;65(11):745-748
Purpose:
We present a case of central anticholinergic syndrome following the administration of atropine eye drops.Case summary: A 60-year-old male presented with decreased visual acuity in his left eye and was diagnosed with intraocular lens dislocation. Preoperatively, Isopto atropine® eye drops (1 drop at 15-minutes intervals) were used for pupil dilation. Within an hour of the first instillation, the patient exhibited drowsiness, disorientation, agitation, and urinary retention. Laboratory tests and computed tomography of the brain were unremarkable. Considering the recent administration of atropine eye drops, a diagnosis of central anticholinergic syndrome was made. The surgery was postponed and the patient recovered fully after 3 hours of observation. He remained asymptomatic during an additional day of hospitalization.
Conclusions
A small dose of atropine eye drops even at a therapeutic dose can induce central anticholinergic syndrome. Therefore, ophthalmologists should be aware of this rare and severe complication.
7.Central Anticholinergic Syndrome Induced by Atropine Eye Drops: A Case Report
Jung Sun HEO ; Je Jin LEE ; Sang Uk CHOI ; Nam Ju MOON ; Joon Hyung YEO
Journal of the Korean Ophthalmological Society 2024;65(11):745-748
Purpose:
We present a case of central anticholinergic syndrome following the administration of atropine eye drops.Case summary: A 60-year-old male presented with decreased visual acuity in his left eye and was diagnosed with intraocular lens dislocation. Preoperatively, Isopto atropine® eye drops (1 drop at 15-minutes intervals) were used for pupil dilation. Within an hour of the first instillation, the patient exhibited drowsiness, disorientation, agitation, and urinary retention. Laboratory tests and computed tomography of the brain were unremarkable. Considering the recent administration of atropine eye drops, a diagnosis of central anticholinergic syndrome was made. The surgery was postponed and the patient recovered fully after 3 hours of observation. He remained asymptomatic during an additional day of hospitalization.
Conclusions
A small dose of atropine eye drops even at a therapeutic dose can induce central anticholinergic syndrome. Therefore, ophthalmologists should be aware of this rare and severe complication.
8.Development of an Instrument for Slit-lamp Examination of Donor Corneas in Preservation Medium
Ga Hee NAM ; Da Ran KIM ; Young Chae YOON ; Soon Won YANG ; Woong Joo WHANG ; Yong-Soo BYUN ; Hyung Bin HWANG ; Kyung Sun NA ; Hyun Soo LEE ; So Hyang CHUNG ; Eun Chul KIM ; Yang Kyung CHO ; Hyun Seung KIM ; Ho Sik HWANG
Journal of the Korean Ophthalmological Society 2024;65(2):108-116
Purpose:
To evaluate the effectiveness of an instrument devised for slit-lamp examination of donor corneas suspended in preservation medium.
Methods:
The study examined two donor corneas received at Yeouido St. Mary's Hospital in February 2023 and March 2023. The instrument has three main components: a plastic holder to hold the preservation medium bottle, a cube with a mirror for reflecting the slit beam, and a stand to attach the device to the slit-lamp. Using the instrument, the donor corneas were examined via slit-lamp: microscopy with the endothelium facing upward and downward. Specular microscopy and anterior segment optical coherence tomography (OCT) were also performed on the preserved donor corneas.
Results:
Slit-lamp examination of donor corneas in preservation medium using the instrument showed overall corneal buttoning and optical sections of the donor cornea. Using specular reflection and retroillumination, the endothelial layer was partially visible. However, specular microscopy and anterior segment OCT could not examine the donor cornea in preservation medium using the instrument.
Conclusions
The devised instrument facilitates slit-lamp examination of donor corneas in preservation medium, enabling a qualitative assessment of donor corneas before corneal transplantation surgery.
9.Central Anticholinergic Syndrome Induced by Atropine Eye Drops: A Case Report
Jung Sun HEO ; Je Jin LEE ; Sang Uk CHOI ; Nam Ju MOON ; Joon Hyung YEO
Journal of the Korean Ophthalmological Society 2024;65(11):745-748
Purpose:
We present a case of central anticholinergic syndrome following the administration of atropine eye drops.Case summary: A 60-year-old male presented with decreased visual acuity in his left eye and was diagnosed with intraocular lens dislocation. Preoperatively, Isopto atropine® eye drops (1 drop at 15-minutes intervals) were used for pupil dilation. Within an hour of the first instillation, the patient exhibited drowsiness, disorientation, agitation, and urinary retention. Laboratory tests and computed tomography of the brain were unremarkable. Considering the recent administration of atropine eye drops, a diagnosis of central anticholinergic syndrome was made. The surgery was postponed and the patient recovered fully after 3 hours of observation. He remained asymptomatic during an additional day of hospitalization.
Conclusions
A small dose of atropine eye drops even at a therapeutic dose can induce central anticholinergic syndrome. Therefore, ophthalmologists should be aware of this rare and severe complication.
10.Comparative analysis of recurrence rates between intravesical gemcitabine and bacillus Calmette–Guérin induction therapy following transurethral resection of bladder tumors in patients with intermediate- and high-risk bladder cancer: A retrospective multicenter study
Joongwon CHOI ; Kyung Hwan KIM ; Hyung Suk KIM ; Hyun Sik YOON ; Jung Hoon KIM ; Jin Wook KIM ; Yong Seong LEE ; Se Young CHOI ; In Ho CHANG ; Young Hwii KO ; Wan SONG ; Byong Chang JEONG ; Jong Kil NAM
Investigative and Clinical Urology 2024;65(3):248-255
Purpose:
This study investigated the efficacy of intravesical gemcitabine as an alternative to bacillus Calmette–Guérin (BCG) therapy.
Materials and Methods:
Data were retrospectively collected across seven institutions from February 1999 to May 2023. Inclusion criteria included patients with intermediate- or high-risk non-muscle invasive bladder cancer (NMIBC) who underwent transurethral resection of bladder tumors (TURBT) and received at least four sessions of intravesical gemcitabine or BCG induction therapy. Patient characteristics, complete remission (CR), occurrence, and progression rates were compared.
Results:
In total, 149 patients were included in this study (gemcitabine, 63; BCG, 86). No differences were apparent between the two groups in baseline characteristics, except for the follow-up period (gemcitabine, 9.2±5.9 months vs. BCG, 43.9±41.4 months, p<0.001). There were no consistent significant differences observed between the two groups in the 3-month (gemcitabine, 98.4% vs. BCG, 95.3%; p=0.848), 6-month (94.9% vs. 90.0%, respectively; p=0.793) and 1-year CR rates (84.2% vs. 83.3%, respectively;p=0.950). Also, there was no significant statistical difference in progression-free survival between the two groups (p=0.953). The occurrence rates of adverse events were similar between the groups (22.2% vs. 22.1%; p=0.989); however, the rate of Clavien– Dindo grade 2 or higher was significantly higher in the BCG group (1.6% vs. 16.3%, respectively; p<0.001).
Conclusions
Intravesical gemcitabine demonstrated efficacy comparable to BCG therapy for the first year in patients with intermediate- and high-risk NMIBC. However, long-term follow-up studies are warranted.

Result Analysis
Print
Save
E-mail