1.Nationwide Survey on Endoscopic Submucosal Dissection for Early Gastric Cancer in Korea: Results From the Korean College of Helicobacter and Upper Gastrointestinal Research (KCHUGR) 2023 Survey
Jae Yong PARK ; Jeong Hoon LEE ; Tae-Se KIM ; Da Hyun JUNG ; Bong Eun LEE ; Yonghoon CHOI ; Wan-Sik LEE ; Young-Il KIM ; Sun Hyung KANG ; Hyunsoo CHUNG ; Su Jin KIM ; Joon Sung KIM ; Donghoon KANG ; Su Youn NAM ; Seung Han KIM ; Hyo-Joon YANG ; Hyun LIM ; Jin LEE ; Seon-Young PARK ; Seung-Woo LEE ; Sun Moon KIM ; Sam Ryong JEE ; Dae Young CHEUNG ; Chung Hyun TAE ; Seokin KANG ; Sung Chul PARK ; Seung In SEO ; Cheol Min SHIN ; Kee Don CHOI ; Jong Yeul LEE ;
Journal of Gastric Cancer 2026;26(2):169-183
Purpose:
Endoscopic submucosal dissection (ESD) has become a standard minimally invasive treatment for selected patients with early gastric cancer (EGC). This study presents the first nationwide survey of patients with EGC treated with ESD in 2023, conducted by the Korean College of Helicobacter and Upper Gastrointestinal Research.
Materials and Methods:
Data were retrospectively collected from participating referral centers across Korea using a standardized case report form covering patient characteristics, tumor features, procedural details, histopathological findings, and clinical outcomes.Descriptive and comparative analyses were conducted to summarize nationwide ESD practice patterns and outcomes.
Results:
Data from 5,460 ESD cases from 5,250 patients across 27 institutions were analyzed. The mean age was 67.4 years, with 74.1% males. Multiple synchronous lesions were identified in 3.7%. Most lesions were located in the lower third of the stomach (64.0%), and differentiated-type adenocarcinomas accounted for 87.8%. The en bloc and complete resection rates were 99.2% and 91.4%, respectively. Curative resection was achieved in 80.5%, whereas local non-curative resection (L-NCR) and surgical non-curative resection (S-NCR) were identified in 2.8% and 16.7%, respectively. Additional surgery was performed more frequently in patients with S-NCR than in those with L-NCR (59.3% vs. 24.7%). The bleeding and perforation rates were 3.6% and 0.9%, respectively, and were mostly managed conservatively or endoscopically. The median length of hospitalization was 4.0 days.
Conclusions
This first nationwide survey provides a comprehensive overview of the current practice of EGC treatment using ESD in Korea, demonstrating high technical success and safety, and establishing a baseline dataset for future longitudinal research.
2.Bisphosphonates as a Tacrolimus-Sparing Strategy in Kidney Transplantation: Insights from a Retrospective Analysis
Hee Byung KOH ; Hyo Jeong KIM ; Ga Young HEO ; Namki HONG ; Yaeji LEE ; Seung Hwan SONG ; Hoon Young CHOI ; Chan-Young JUNG ; Hyung Woo KIM ; Jaeseok YANG ; Kyu Ha HUH ; Chung Mo NAM ; Beom Seok KIM
Yonsei Medical Journal 2026;67(1):17-26
Purpose:
Due to chronic toxicity, tacrolimus-sparing is an important issue in kidney transplant recipients (KTRs). Several studies have shown that bisphosphonate use is associated with favorable graft outcomes in KTRs. We investigated whether the association between tacrolimus trough levels (TTLs) and graft outcomes differed according to bisphosphonate use in KTRs.
Materials and Methods:
We conducted a retrospective study encompassing 1441 KTRs who were administered tacrolimus-based immunosuppressants. The primary exposure was a time-dependent cross-product of TTLs (low TTLs vs. normal-high TTLs with a reference of 6 ng/mL) and bisphosphonate use. Two primary outcomes were evaluated: overall graft loss (death or conversion to kidney replacement) and an estimated glomerular filtration rate (eGFR) <30 mL/min/1.73 m 2 .
Results:
During the median follow-up of 6.1 (3.4–9.7) years, overall graft loss occurred in 157 (10.9%) patients. Cox regression revealed that normal-high TTLs without bisphosphonate use were associated with a reduced risk of overall graft loss [adjusted hazard ratio (aHR), 0.65; 95% confidence interval (CI), 0.45–0.95] compared to low TTLs without bisphosphonate use. The use of bisphosphonate in conjunction with normal-high TTLs correlated with an even lower risk of overall graft loss (aHR, 0.25; 95% CI, 0.08–0.80) compared with low TTLs without bisphosphonate use. In patients with low TTLs, bisphosphonate use was associated with a reduced risk of overall graft loss compared with non-use (aHR, 0.20; 95% CI, 0.09–0.43). Similar trends were observed in the eGFR outcome.
Conclusion
The use of bisphosphonate was associated with favorable graft outcomes, even with low TTLs. Incorporating bisphosphonate into a conventional immunosuppressant regimen may potentially reduce tacrolimus requirement.
3.Nationwide Survey on Endoscopic Submucosal Dissection for Early Gastric Cancer in Korea: Results From the Korean College of Helicobacter and Upper Gastrointestinal Research (KCHUGR) 2023 Survey
Jae Yong PARK ; Jeong Hoon LEE ; Tae-Se KIM ; Da Hyun JUNG ; Bong Eun LEE ; Yonghoon CHOI ; Wan-Sik LEE ; Young-Il KIM ; Sun Hyung KANG ; Hyunsoo CHUNG ; Su Jin KIM ; Joon Sung KIM ; Donghoon KANG ; Su Youn NAM ; Seung Han KIM ; Hyo-Joon YANG ; Hyun LIM ; Jin LEE ; Seon-Young PARK ; Seung-Woo LEE ; Sun Moon KIM ; Sam Ryong JEE ; Dae Young CHEUNG ; Chung Hyun TAE ; Seokin KANG ; Sung Chul PARK ; Seung In SEO ; Cheol Min SHIN ; Kee Don CHOI ; Jong Yeul LEE ;
The Korean Journal of Helicobacter and Upper Gastrointestinal Research 2026;26(1):50-59
Objectives:
Endoscopic submucosal dissection (ESD) has become a standard minimally invasive treatment for selected patients with early gastric cancer (EGC). This study presents the first nationwide survey of patients with EGC treated with ESD in 2023, conducted by the Korean College of Helicobacter and Upper Gastrointestinal Research.
Methods:
Data were retrospectively collected from participating referral centers across Korea using a standardized case report form covering patient characteristics, tumor features, procedural details, histopathological findings, and clinical outcomes. Descriptive and comparative analyses were conducted to summarize nationwide ESD practice patterns and outcomes.
Results:
Data from 5460 ESD cases from 5250 patients across 27 institutions were analyzed. The mean age was 67.4 years, with 74.1% males. Multiple synchronous lesions were identified in 3.7%. Most lesions were located in the lower third of the stomach (64.0%), and differentiated-type adenocarcinomas accounted for 87.8%. The en bloc and complete resection rates were 99.2% and 91.4%, respectively. Curative resection was achieved in 80.5%, whereas local non-curative resection (L-NCR) and surgical non-curative resection (S-NCR) were identified in 2.8% and 16.7%, respectively. Additional surgery was performed more frequently in patients with S-NCR than in those with L-NCR (59.3% vs. 24.7%). The bleeding and perforation rates were 3.6% and 0.9%, respectively, and were mostly managed conservatively or endoscopically. The median length of hospitalization was 4.0 days.
Conclusions
This first nationwide survey provides a comprehensive overview of the current practice of EGC treatment using ESD in Korea, demonstrating high technical success and safety, and establishing a baseline dataset for future longitudinal research.
4.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
5.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
6.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
7.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
8.Deformation analysis of 3D-printed three-unit fixed partial dentures according to various cleaning strategies after DLP 3D printing:a geometric library matching approach
Yuwon JEONG ; Sang-Yeop CHUNG ; Ju Ri YE ; Ok Hyung NAM ; Hyeonjong LEE
The Journal of Advanced Prosthodontics 2025;17(1):11-21
PURPOSE:
Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
MATERIALS AND METHODS:
A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
RESULTS:
Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
CONCLUSION
Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
9.Clinical Practice Guidelines for Diagnosis and Non-Surgical Treatment of Primary Frozen Shoulder
Byung Chan LEE ; Gi-Wook KIM ; Keewon KIM ; Nackhwan KIM ; Dong Hwan KIM ; Doo Young KIM ; Du Hwan KIM ; Beom Suk KIM ; Seong Hun KIM ; In Jong KIM ; Hyun Jung KIM ; Yoonju NA ; Kyung Eun NAM ; Sung Gyu MOON ; Chang-Won MOON ; Kyunghoon MIN ; Donghwi PARK ; Myung Woo PARK ; Yong Bok PARK ; Jae Hyeon PARK ; Chul-Hyun PARK ; Hyeng-Kyu PARK ; Yunsoo SOH ; Jaeki AHN ; Seoyon YANG ; Kyeong Eun UHM ; Sun Jae WON ; Yu Hui WON ; Dong Hwan YUN ; Yu Sung YOON ; Jin A YOON ; Byeong-Ju LEE ; Woo Hyung LEE ; Yun Jung LEE ; Jae-Hyun LEE ; Jong Hwa LEE ; Yu Jin IM ; Jae-Young LIM ; Min Cheol CHANG ; Sung Joon CHUNG ; Il Young JUNG ; Sungju JEE ; Kyoung Hyo CHOI ; Jong-Moon HWANG ; Jae-Young HAN
Clinical Pain 2025;24(1):1-26
Objective:
Primary frozen shoulder causes significant pain and progressively restricts shoulder movements. Diagnosis is made clinically based on patient history and physical examination. Management is mainly non-invasive owing to its self-limiting clinical course. However, clinical practice guidelines for frozen shoulder have not yet been developed in Korea. The developed guidelines aim to provide evidence-based recommendations for the diagnosis and treatment of frozen shoulder.
Methods:
A guideline development committee reviewed the literature from four databases (PubMed, Embase, Cochrane Library, and KMbase). Using the Population, Intervention, Comparator, and Outcome (PICO) framework, the committee formulated two backgrounds and 16 key questions to address common clinical concerns. Recommendations were made using the Grading of Recommendations, Assessment, Development, and Evaluation framework.
Results:
Diabetes, thyroid disease, and dyslipidemia significantly increase the risk of developing a frozen shoulder. Although frozen shoulder is often self-limiting, some patients may experience long-term functional disabilities. Ultrasound and magnetic resonance imaging should be used as adjunctive tools alongside clinical diagnosis, and rather than as independent diagnostic methods. Noninvasive approaches, such as medications, physical modalities, exercises, electrical stimulation, and manual therapy, may reduce pain and improve shoulder function. Other noninvasive interventions have limited evidence, and their application should be based on clinical judgment. Intra-articular steroid injections are recommended for treatment, and physiotherapy or hydrodilation with steroid injections can also be beneficial.
Conclusion
These guidelines provide evidence-based recommendations for diagnosing and treating primary frozen shoulder.
10.Development of an Instrument for Slit-lamp Examination of Donor Corneas in Preservation Medium
Ga Hee NAM ; Da Ran KIM ; Young Chae YOON ; Soon Won YANG ; Woong Joo WHANG ; Yong-Soo BYUN ; Hyung Bin HWANG ; Kyung Sun NA ; Hyun Soo LEE ; So Hyang CHUNG ; Eun Chul KIM ; Yang Kyung CHO ; Hyun Seung KIM ; Ho Sik HWANG
Journal of the Korean Ophthalmological Society 2024;65(2):108-116
Purpose:
To evaluate the effectiveness of an instrument devised for slit-lamp examination of donor corneas suspended in preservation medium.
Methods:
The study examined two donor corneas received at Yeouido St. Mary's Hospital in February 2023 and March 2023. The instrument has three main components: a plastic holder to hold the preservation medium bottle, a cube with a mirror for reflecting the slit beam, and a stand to attach the device to the slit-lamp. Using the instrument, the donor corneas were examined via slit-lamp: microscopy with the endothelium facing upward and downward. Specular microscopy and anterior segment optical coherence tomography (OCT) were also performed on the preserved donor corneas.
Results:
Slit-lamp examination of donor corneas in preservation medium using the instrument showed overall corneal buttoning and optical sections of the donor cornea. Using specular reflection and retroillumination, the endothelial layer was partially visible. However, specular microscopy and anterior segment OCT could not examine the donor cornea in preservation medium using the instrument.
Conclusions
The devised instrument facilitates slit-lamp examination of donor corneas in preservation medium, enabling a qualitative assessment of donor corneas before corneal transplantation surgery.

Result Analysis
Print
Save
E-mail