1.Just 1-min exposure to a pure tone at 100 Hz with daily exposable sound pressure levels may improve motion sickness.
Yishuo GU ; Nobutaka OHGAMI ; Tingchao HE ; Takumi KAGAWA ; Fitri KURNIASARI ; Keming TONG ; Xiang LI ; Akira TAZAKI ; Kodai TAKEDA ; Masahiro MOURI ; Masashi KATO
Environmental Health and Preventive Medicine 2025;30():22-22
BACKGROUND:
Motion sickness is a common transportation issue worldwide. Vestibular dysfunction has been reported to be a key etiology of motion sickness. However, there are limited technologies for alleviating motion sickness.
METHODS:
The most appropriate frequency (Hz) and level (dBZ) of pure tone for modulation of vestibular function were determined by an ex vivo study using murine utricle explants. The preventive effects of the selected pure tone on motion sickness were then confirmed by using a beam balance test in mice. The alleviating effects of pure tone on motion sickness induced by a swing, driving simulator or real car were objectively assessed by using posturography and electrocardiography (ECG) and were subjectively assessed by using the Motion Sickness Assessment Questionnaire (MSAQ) in humans.
RESULTS:
The effect of short-term (≤5 min) exposure to a pure tone of 80-85 dBZ (= 60.9-65.9 dBA) at 100 Hz on motion sickness was investigated in mice and humans. A mouse study showed a long-lasting (≥120 min) alleviative effect on shaking-mediated exacerbated beam test scores by 5-min exposure to a pure tone of 85 dBZ at 100 Hz, which was ex vivo determined as a sound activating vestibular function, before shaking. Human studies further showed that 1-min exposure to a pure tone of 80-85 dBZ (= 60.9-65.9 dBA) at 100 Hz before shaking improved the increased envelope areas in posturography caused by the shakings of a swing, a driving simulator and a vehicle. Driving simulator-mediated activation of sympathetic nerves assessed by the heart rate variable (HRV) and vehicle-mediated increased scores of the MSAQ were improved by pure tone exposure before the shaking.
CONCLUSION:
Since the exacerbated results of posturography and HRV reflect shaking-mediated imbalance and autonomic dysfunction, respectively, the results suggest that the imbalance and autonomic dysregulation in motion sickness could be improved by just 1-min exposure to a pure tone with daily exposable sound pressure levels.
TRIAL REGISTRATION
Registration number: UMIN000022413 (2016/05/23-2023/04/19) and UMIN000053735 (2024/02/29-present).
Motion Sickness/therapy*
;
Animals
;
Mice
;
Humans
;
Male
;
Adult
;
Female
;
Sound
;
Middle Aged
;
Young Adult
;
Mice, Inbred C57BL
2.Comparation of anterior maxilla and whole maxilla clockwise rotation to improve paranasal aesthetic defects of skeletal Class Ⅲ maxillofacial deformity.
Fengqi SONG ; Xinyu XU ; Xiaojing LIU ; Zili LI
Journal of Peking University(Health Sciences) 2025;57(5):980-988
OBJECTIVE:
To compare the aesthetic effects of anterior maxilla clockwise rotation combined with segmental Le Fort Ⅰ osteotomy and whole maxilla clockwise rotation on improving paranasal concavity in patients with Class Ⅲ maxillofacial deformity.
METHODS:
A non-randomized controlled trial was designed, and 21 patients diagnosed with skeletal Class Ⅲ maxillofacial deformity were included. In the study, 11 patients in the test group were treated by segmental Le Fort Ⅰ osteotomy combined with anterior maxilla clockwise rotation, and 10 patients in the control group were treated by whole maxilla clockwise rotation. The CBCT and 3D photography of preoperative (T0), 2 weeks postoperative (T1), and 6 months postoperative (T2) were collected respectively, and the three-dimensional cephalometry was carried out. The differences of specific parameters between the two groups were compared by independent sample t-test, including saggital displacement of the cheek mass point (CK) and subalare point (SA), nasolabial angle, occlusal plane angle and labial inclination angle of the upper incisor.
RESULTS:
There were no significant differences of the parameters on T0 between the two groups. The average sagittal displacement of the upper incisors of the test group was (-0.71±1.67) mm and smaller than that of control group [(2.26±1.68) mm], t=-4.052, P < 0.05. The average angle of the occlusal plane clockwise rotation of the test group was 1.46°±2.38° and smaller than that of the control group (4.31°±1.83°), t=-3.047, P < 0.05. The angle of anterior maxilla clockwise rotation was 11.73°±2.81° during the surgery. The average saggital displacement of the paranasal soft tissue landmarks of the test group from T0 to T2 was larger than that of the control group [CK point, (4.96±1.18) mm vs. (2.01± 1.50) mm, P < 0.05;SA point, (5.19±1.17) mm vs. (2.69±1.45) mm, P < 0.05]. The labial inclination angle of the upper incisor of the test group was 112.15°±5.40° in T2 and significantly smaller than that of the control group (122.38°±8.83°), t=-3.237, P < 0.05. The nasolabial angle of the test group was 106.54°±12.82° in T2 and significantly larger than that of the control group (93.90°±12.46°), t=2.288, P < 0.05.
CONCLUSION
Compared with whole maxilla clockwise rotation, anterior maxilla clockwise rotation combined with segmental Le Fort Ⅰ osteotomy can increase the saggital displacement of the paranasal soft tissue, correct labial inclination of the upper incisors and the acute naso-labial angle and better improve the paranasal aesthetic defects in patients with Class Ⅲ maxillofacial deformity with less changing on the saggital orientation of the upper incisors and the occlusal plane angle.
Humans
;
Maxilla/surgery*
;
Female
;
Male
;
Osteotomy, Le Fort/methods*
;
Malocclusion, Angle Class III/surgery*
;
Adult
;
Cephalometry
;
Young Adult
;
Rotation
;
Adolescent
3.3D Pulse Image Detection and Pulse Pattern Recognition Based on Subtle Motion Magnification Technology.
Chongyang YAO ; Yongxin CHOU ; Zhiwei LIANG ; Haiping YANG ; Jicheng LIU ; Dongmei LIN
Chinese Journal of Medical Instrumentation 2025;49(3):255-262
To address the problem of large reconstruction errors in 3D pulse signals caused by excessively small out-of-plane displacement of the contact membrane in the existing traditional Chinese medicine fingertip tactile binocular vision detection technology, this study proposes a 3D pulse image detection method based on subtle motion magnification technology and explores its application in pulse pattern recognition. Firstly, a 3D pulse image detection system based on binocular vision to obtain pulse image signals is developed as experimental data. Then, the phase motion video magnification algorithm is used to amplify the original signals, and the amplified signals are reconstructed in three dimensions to obtain 3D pulse signals. On this basis, nine features are extracted from the 3D pulse signals and features selection is performed using a two-sample Kolmogorov-Smirnov test. Finally, machine learning algorithms such as decision trees and random forests are used to identify the five types of pulse conditions: deep pulse, intermittent pulse, flooding pulse, slippery pulse, and rapid pulse. The experimental results show that compared to the methods without subtle motion magnification technology, the proposed method significantly improves waveform clarity, amplitude stability, and periodic regularity. Meanwhile, the average accuracy in pulse pattern recognition reaches 96.29%±0.26%.
Algorithms
;
Imaging, Three-Dimensional/methods*
;
Pattern Recognition, Automated
;
Medicine, Chinese Traditional
;
Motion
;
Humans
;
Pulse
;
Signal Processing, Computer-Assisted
;
Machine Learning
4.A segmented backprojection tensor degradation feature encoding model for motion artifacts correction in dental cone beam computed tomography.
Zhixiong ZENG ; Yongbo WANG ; Zongyue LIN ; Zhaoying BIAN ; Jianhua MA
Journal of Southern Medical University 2025;45(2):422-436
OBJECTIVES:
We propose a segmented backprojection tensor degradation feature encoding (SBP-MAC) model for motion artifact correction in dental cone beam computed tomography (CBCT) to improve the quality of the reconstructed images.
METHODS:
The proposed motion artifact correction model consists of a generator and a degradation encoder. The segmented limited-angle reconstructed sub-images are stacked into the tensors and used as the model input. A degradation encoder is used to extract spatially varying motion information in the tensor, and the generator's skip connection features are adaptively modulated to guide the model for correcting artifacts caused by different motion waveforms. The artifact consistency loss function was designed to simplify the learning task of the generator.
RESULTS:
The proposed model could effectively remove motion artifacts and improve the quality of the reconstructed images. For simulated data, the proposed model increased the peak signal-to-noise ratio by 8.28%, increased the structural similarity index measurement by 2.29%, and decreased the root mean square error by 23.84%. For real clinical data, the proposed model achieved the highest expert score of 4.4221 (against a 5-point scale), which was significantly higher than those of all the other comparison methods.
CONCLUSIONS
The SBP-MAC model can effectively extract spatially varying motion information in the tensors and achieve adaptive artifact correction from the tensor domain to the image domain to improve the quality of reconstructed dental CBCT images.
Cone-Beam Computed Tomography/methods*
;
Artifacts
;
Humans
;
Motion
;
Image Processing, Computer-Assisted/methods*
;
Signal-To-Noise Ratio
;
Algorithms
5.Synthesis of a temperature-responsive multimodal motion microrobot capable of precise navigation for targeted controllable drug release.
Xuhui ZHAO ; Mengran LIU ; Xi CHEN ; Jing HUANG ; Yuan LIU ; Haifeng XU
Journal of Southern Medical University 2025;45(8):1758-1767
OBJECTIVES:
To synthesize a temperature-responsive multimodal motion microrobot (MMMR) using temperature and magnetic field-assisted microfluidic droplet technology to achieve targeted drug delivery and controlled drug release.
METHODS:
Microfluidic droplet technology was utilized to synthesize the MMMR by mixing gelatin with magnetic microparticles. The microrobot possessed a magnetic anisotropy structure to allow its navigation and targeted drug release by controlling the temperature field and magnetic field. In the experiment, the MMMR was controlled to move in a wide range along a preset path by rotating a uniform magnetic field, and the local circular motion was driven by a planar rotating gradient magnetic field of different frequencies. The MMMR was loaded with simulated drugs, which were released in response to laser heating.
RESULTS:
Driven by a rotating magnetic field, the MMMR achieved linear motion following a predefined path. The planar gradient rotating magnetic field controlled circular motion of the MMMR with an adjustable radius, utilizing the centrifugal force generated by rotation. The drug-loaded MMMR successfully reached the target location under magnetic guidance, where the gelatin matrix was melted using laser heating for accurate drug release, after which the remaining magnetic particles were removed using magnetic field.
CONCLUSIONS
The MMMR possesses multimodal motion capabilities to enable precise navigation along a predefined path and dynamic regulation of drug release within the target area, thus having great potential for a wide range of biomedical applications.
Drug Delivery Systems/methods*
;
Temperature
;
Drug Liberation
;
Magnetic Fields
;
Robotics
;
Gelatin/chemistry*
;
Delayed-Action Preparations
;
Microfluidics
;
Motion
6.Research on machine-learning quantitative evaluative model of manual acupuncture manipulation based on three-dimensional motion tracking technology.
Jiayao WAN ; Binggan WANG ; Tianai HUANG ; Fan WANG ; Wenchao TANG
Chinese Acupuncture & Moxibustion 2025;45(9):1201-1208
OBJECTIVE:
To develop an objective quantitative evaluative model of manual acupuncture manipulation (MAM) using three-dimensional motion tracking technology and machine learning, so as to provide a new approach to the study on acupuncture and moxibustion education and manipulation standardization.
METHODS:
A total of 120 undergraduate students in the major of acupuncture-moxibustion and tuina were recruited. The Simi Motion Ver.8.5 motion tracking system was used to collect the data of three types of MAM, balanced reinforcing and reducing by twisting, reinforcing technique by twisting and reducing technique by twisting. Eight quantitative parameters covering movement performance and stability were established. With 5 types of machine learning algorithms (logistic regression, random forest, support vector machine, K-nearest neighbor, and decision tree) adopted, the evaluative model was constructed, and the feature importance analyzed.
RESULTS:
In the evaluation of different types of MAM, the support vector machine presented the best for the effects of the balanced reinforcing and reducing by twisting, and the reducing by twisting (accuracy rates were both 0.88); and the logistic regression algorithm showed the optimal performance in evaluating the reinforcing by twisting (1.00 of accuracy rate). Feature importance analysis revealed that twisting velocity was the dominant parameter for evaluating the balanced reinforcing-reducing manipulation. The reinforcing and reducing of acupuncture techniques were more dependent on the left-hand twisting parameters and comprehensive performances, respectively.
CONCLUSION
The objective evaluative model of MAM based on three-dimensional motion tracking technology and machine learning demonstrates a reliable evaluative performance, providing a new technical approach to standardized assessment in acupuncture and moxibustion education.
Humans
;
Male
;
Acupuncture Therapy/instrumentation*
;
Machine Learning
;
Female
;
Young Adult
;
Adult
;
Motion
7.Research progress in motor assessment of neurodegenerative diseases driven by motion capture data.
Junlang WU ; Wei GUO ; Kexin LUO ; Ling HE ; Guanci YANG
Journal of Biomedical Engineering 2025;42(2):396-403
Neurodegenerative diseases (NDDs) are a group of heterogeneous neurological disorders that can cause progressive loss of neurons in the central nervous system or peripheral nervous system, resulting in a decline in motor function. Motion capture, as a high-precision and high-resolution technology for capturing human motion data, drives NDDs motor assessment to effectively extract kinematic features and thus assess the patient's motor ability or disease severity. This paper focuses on the recent research progress in motor assessment of NDDs driven by motion capture data. Based on a brief introduction of NDDs motor assessment datasets, we categorized the assessment methods into three types according to the way of feature extraction and processing: NDDs motor assessment methods based on statistical analysis, machine learning and deep learning. Then, we comparatively analyzed the technical points and characteristics of the three types of methods from the aspects of data composition, data preprocessing, assessment methods, assessment purposes and effects. Finally, we discussed and prospected the development trends of NDDs motor assessment.
Humans
;
Neurodegenerative Diseases/diagnosis*
;
Machine Learning
;
Biomechanical Phenomena
;
Deep Learning
;
Motion
;
Motion Capture
8.Early effectiveness of navigation-free robot-assisted total knee arthroplasty in treating knee osteoarthritis with extra-articular deformities.
Chen MENG ; Yongqing XU ; Rongmao SHI ; Luqiao PU ; Jian'an JI ; Xingyou YAO ; Xizong ZHOU ; Chuan LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):5-12
OBJECTIVE:
To evaluate the early effectiveness of navigation-free robot-assisted total knee arthroplasty (TKA) compared to traditional TKA in the treatment of knee osteoarthritis combined with extra-articular deformities.
METHODS:
The clinical data of 30 patients with knee osteoarthritis combined with extra-articular deformities who met the selection criteria between June 2019 and January 2024 were retrospectively analyzed. Fifteen patients underwent CORI navigation-free robot-assisted TKA and intra-articular osteotomy (robot group) and 15 patients underwent traditional TKA and intra-articular osteotomy (traditional group). There was no significant difference in age, gender, body mass index, affected knee side, extra-articular deformity angle, deformity position, deformity type, and preoperative knee range of motion, American Knee Society (KSS) knee score and KSS function score, and lower limb alignment deviation between the two groups ( P>0.05). The operation time, intraoperative blood loss, and complications of the two groups were recorded and compared. The knee range of motion and lower limb alignment deviation were recorded before operation and at 6 months after operation, and the knee joint function was evaluated by KSS knee score and function score.
RESULTS:
There was no significant difference in operation time between the two groups ( P>0.05); the intraoperative blood loss in the robot group was significantly less than that in the traditional group ( P<0.05). Patients in both groups were followed up 6-12 months, with an average of 8.7 months. The incisions of all patients healed well, and there was no postoperative complication such as thrombosis or infection. At 6 months after operation, X-ray examination showed that the position of the prosthesis was good in both groups, and there was no loosening or dislocation of the prosthesis. The knee joint range of motion, the lower limb alignment deviation, and the KSS knee score and KSS function score significantly improved in both groups ( P<0.05) compared to preoperative ones. The changes of lower limb alignment deviation and KSS function score between pre- and post-operation in the robot group were significantly better than those in the traditional group ( P<0.05), while the changes of other indicators between pre- and post-operation in the two groups were not significant ( P>0.05).
CONCLUSION
Compared to traditional TKA, navigation-free robot-assisted TKA for knee osteoarthritis with extra-articular deformities results in less intraoperative blood loss, more precise reconstruction of lower limb alignment, and better early effectiveness. However, long-term effectiveness require further investigation.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Osteoarthritis, Knee/surgery*
;
Robotic Surgical Procedures/methods*
;
Male
;
Female
;
Retrospective Studies
;
Range of Motion, Articular
;
Middle Aged
;
Aged
;
Treatment Outcome
;
Osteotomy/methods*
;
Knee Joint/physiopathology*
;
Operative Time
9.Three-dimensional binding treatment for avulsion fractures of inferior pole of patella utilizing suture anchor.
Hongqing HE ; Ningkai LI ; Meng LIU ; Jiating LIN ; Qiang WANG ; Yinchang ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):26-31
OBJECTIVE:
To explore the feasibility and effectiveness of suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique for avulsion fractures of the inferior pole of the patella.
METHODS:
A clinical data of 38 patients with avulsion fractures of the inferior pole of the patella, who met the selective criteria and were admitted between September 2021 and April 2023, was retrospectively analyzed. The fractures were treated with suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique in 18 cases (group A) and steel wire tension-band fixation in 20 cases (group B). There was no significant difference in terms of age, gender, cause of fracture, side of fracture, and disease duration between the two groups ( P>0.05). The length of incision, operation time, occurrence of complications, the range of motion of knee joint, and Böstman score of knee joint at last follow-up were recorded. The fracture healing was evaluated through X-ray films and the time of fracture healing was recorded.
RESULTS:
All incisions healed by first intention. The length of incision was significantly shorter in group A than in group B ( P<0.05). There was no significant difference in the operation time between the two groups ( P>0.05). All patients were followed up 12-24 months (mean, 16.1 months). X-ray films showed that all fractures healed and there was no significant difference in the healing time between the two groups ( P>0.05). At last follow-up, the range of motion and Böstman score of the knee joint in group A were significantly better than those in group B ( P<0.05). During follow-up, 1 patient (5.6%) in group A had one anchor mild prolapse and 3 patients (15.0%) occured internal fixation irritation in group B. But there was no significant difference in the incidence of complications between the two groups ( P>0.05).
CONCLUSION
For the avulsion fractures of the inferior pole of the patella, the suture anchor double-pulley technique combined with suture three-dimensional binding via bone tunnel technique has advantages of reliable fixation, small incision, avoidance of secondary operation to remove internal fixator, and fewer complications, with definite effectiveness.
Humans
;
Male
;
Female
;
Patella/surgery*
;
Suture Anchors
;
Fracture Fixation, Internal/instrumentation*
;
Adult
;
Retrospective Studies
;
Middle Aged
;
Fractures, Avulsion/surgery*
;
Treatment Outcome
;
Young Adult
;
Range of Motion, Articular
;
Fracture Healing
;
Adolescent
;
Suture Techniques
;
Knee Joint/physiopathology*
10.Wrist arthroscopic Wafer surgery combined with triangular fibrocartilage complex insertion point reconstruction in treatment of Palmer type ⅡC combined with type ⅠB ulnar impingement syndrome.
Yong LI ; Mingming MA ; Xiaojun RUAN ; Yongbin FU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):59-63
OBJECTIVE:
To investigate the effectivess of arthroscopic Wafer surgery combined with triangular fibrocartilage complex (TFCC) insertion point reconstruction in the treatment of Palmer type ⅡC combined with typeⅠB ulnar impingement syndrome.
METHODS:
The clinical data of 14 patients with Parlmer type ⅡC combined with type ⅠB ulnar impingement syndrome who met the selection criteria between July 2021 and April 2024 were retrospectively analyzed. There were 7 males and 7 females with an average age of 43 years ranging from 16 to 59 years. The causes of injury were fall in 8 cases and sprain in 6 cases. The time from injury to operation ranged from 1 to 6 months, with an average of 2.3 months. Distal radioulnar joint instability was found in all cases. Arthroscopic Wafer surgery combined with TFCC insertion point reconstruction was used. The effectiveness was evaluated by comparing the wrist flexion-dorsiflexion range of motion, wrist ulnar deviation-radial deflection range of motion, forearm pronation-supination range of motion, visual analogue scale (VAS) score, and modified Mayo wrist score before and after operation.
RESULTS:
All patients were followed up 6-12 months, with an average of 9.1 months. The positive variation of ulna was (3.2±0.7) mm before operation, and the negative variation of ulna was (2.2±0.6) mm after operation. There was a significant difference in ulna variation between pre- and post-operation ( t=23.851, P<0.001). The pain symptoms and forearm rotation function of the patients after operation significantly improved. At last follow-up, the wrist flexion-dorsiflexion range of motion, wrist ulnar deviation-radial deflection range of motion, forearm pronation-supination range of motion, VAS score, and modified Mayo wrist score significantly improved when compared with those before operation ( P<0.05).
CONCLUSION
Arthroscopic Wafer surgery combined with TFCC insertion point reconstruction can effectively relieve wrist pain, enhance the stability of the distal radioulnar joint, and restore the function of the wrist in patients with Palmer type ⅡC combined with type ⅠB ulnar impingement syndrome.
Humans
;
Male
;
Adult
;
Arthroscopy/methods*
;
Female
;
Triangular Fibrocartilage/surgery*
;
Middle Aged
;
Range of Motion, Articular
;
Retrospective Studies
;
Wrist Joint/physiopathology*
;
Adolescent
;
Young Adult
;
Ulna/surgery*
;
Treatment Outcome
;
Wrist Injuries/surgery*
;
Plastic Surgery Procedures/methods*
;
Joint Instability/surgery*

Result Analysis
Print
Save