1.Clinical features and risk factors of left ventricular hypertrophy in children with primary hypertension.
Yang LIU ; Lin SHI ; Yao LIN ; Ya Qi LI ; Yan Yan LIU ; Hong Wei ZHANG
Chinese Journal of Pediatrics 2023;61(11):1031-1037
Objective: To assess the clinical features and relative factors of left ventricular hypertrophy (LVH) in children with primary hypertension. Methods: In this retrospective cohort study, 430 children diagnosed with primary hypertension in Children's Hospital, Capital Institute of Pediatrics from January 2019 to September 2022 were enrolled. Their clinical data was analyzed and LVH was assessed by echocardiography. According to left ventricular geometry, these children were assigned to the LVH group and normal geometry group. General conditions, laboratory indicators and ambulatory blood pressure parameters between two groups were compared by independent sample t-test or Mann-Whitney U test. Spearman correlation coefficient was used to analyze the correlation between LVH and clinical indicators including blood pressure, biochemical and metabolic indicators. The independent risk factors of LVH were analyzed by multivariable logistic regression. The receiver operating characteristic (ROC) curve was used to explore the value of risk factors in the diagnosis of LVH. Results: Among the 430 children with primary hypertension, 342 (79.5%) were males and 88 (20.5%) females. Their age was (12.6±2.3) years, and 123 children (28.6%) of them had LVH. Body mass index (BMI) ((30.0±5.2) vs. (26.2±4.3) kg/m2), ratio of stage 2 hypertension (75.6% (93/123) vs. 59.6% (183/307)), 24-hour systolic blood pressure (24 h SBP)((131±10) vs. (128±10) mmHg,1 mmHg=0.133 kPa), daytime systolic blood pressure (SBP) ((135±11) vs. (131±11) mmHg), nighttime SBP ((128±11) vs. (123±10) mmHg), cholesterol level ((4.0±0.7) vs. (3.9±0.7) mmol/L), serum uric acid level ((447±81) vs. (426±91) μmol/L) and incidence of hyperinsulinemia (69.9% (86/123) vs.59.0% (181/307)) were significantly elevated in the LVH group compared with those in the normal geometry group (all P<0.05). There were more patients with a disease course over 5 years in the LVH group than in the normal geometry group, with a statistically significant difference (χ2=8.90,P=0.031). Spearman correlation analysis showed that BMI, 24 h SBP, daytime SBP, nighttime SBP, triglyceride, uric acid, and serum sodium level were positively correlated with LVMI (r=0.43, 0.20, 0.18, 0.18, 0.18, 0.16, and 0.12, all P<0.05). BMI, hyperinsulinemia, and cholesterol level were positively correlated with relative wall thickness (RWT) (r=0.22, 0.12, and 0.16, all P<0.05). The multivariate logistic regression analysis showed that BMI (OR=1.17, 95%CI 1.10-1.25) and 24 h SBP (OR=1.04, 95%CI 1.01-1.08) were the independent risk factors for LVH (both P<0.05). The area under the receiver operator characteristic curve, combined with BMI and 24 h SBP, was 0.72 (95%CI 0.67-0.77, P<0.05), with a sensitivity and specificity of 71.5% and 64.8%, respectively. Conclusions: BMI and 24 h SBP are the independent risk factors for LVH in children with primary hypertension, and the combination of BMI and 24 h SBP has an acceptable diagnostic value for LVH. Early monitoring of these indexes is necessary to predict preclinical cardiac damage.
Male
;
Female
;
Humans
;
Child
;
Adolescent
;
Hypertension/diagnosis*
;
Hypertrophy, Left Ventricular/etiology*
;
Uric Acid
;
Blood Pressure Monitoring, Ambulatory
;
Retrospective Studies
;
Blood Pressure/physiology*
;
Risk Factors
;
Essential Hypertension
;
Hyperinsulinism
;
Cholesterol
2.Design and Research of Wearable Fall Protection Device for the Elderly.
Jie WANG ; Yeke SUN ; Zhenglong CHEN ; Yongchun JIN ; Yunhua XU
Chinese Journal of Medical Instrumentation 2023;47(3):278-283
A protective device was designed that can be worn on the elderly, which consists of protective airbag, control box and protective mechanism. The combined acceleration, combined angular velocity and human posture angle are selected as the parameters to determine the fall, and the threshold algorithm and SVM algorithm are used to detect the fall. The protective mechanism is an inflatable device based on CO2 compressed air cylinder, and the equal-width cam structure is applied to its transmission part to improve the puncture efficiency of the compressed gas cylinder. A fall experiment was designed to obtain the combined acceleration and angular velocity eigenvalues of fall actions (forward fall, backward fall and lateral fall) and daily activities (sitting-standing, walking, jogging and walking up and down stairs), showing that the specificity and sensitivity of the protection module reached 92.1% and 84.4% respectively, which verified the feasibility of the fall protection device.
Humans
;
Aged
;
Monitoring, Ambulatory
;
Activities of Daily Living
;
Wearable Electronic Devices
;
Walking
;
Acceleration
;
Algorithms
3.Anti-motion Artifact Performance Test System for Ambulatory ECG Monitoring Equipment.
Liping QIN ; Yi WU ; Ke XU ; Xiangrui ZHAO
Chinese Journal of Medical Instrumentation 2023;47(6):624-629
Anti-motion artifact is one of the most important properties of ambulatory ECG monitoring equipment. At present, there is a lack of standardized means to test the performance of anti-motion artifact. ECG simulator and special conductive leather are used to build the simulator, it is used to simulate human skin, to generate ECG signal input for the ECG monitoring equipment attached to it. The mechanical arm and fixed support are used to build a motion simulation system to fix the conductive leather. The mechanical arm is programmed to simulate various motion states of the human body, so that the ECG monitoring equipment can produce corresponding motion artifacts. The collected ECG signals are read wirelessly, observed, analyzed and compared, and the anti-motion artifact performance of ECG monitoring equipment is evaluated. The test results show that by artificially creating the small difference between the two groups of ambulatory ECG monitoring equipment, the system can accurately test the interference signals introduced under the conditions of controlled movement such as tension and torsion, and compare the advantages and disadvantages. The research shows that the test system can provide convenient and accurate verification means for the research of optimizing anti-motion interference.
Humans
;
Artifacts
;
Signal Processing, Computer-Assisted
;
Electrocardiography, Ambulatory/methods*
;
Electrocardiography
;
Motion
4.Effect of Home Blood Pressure Telemonitoring Plus Additional Support on Blood Pressure Control: A Randomized Clinical Trial.
Wen Wen MENG ; Yong Yi BAI ; Li YAN ; Wei ZHENG ; Qiang ZENG ; Yan Song ZHENG ; Lin ZHA ; Hong Ying PI ; Xiao Yong SAI
Biomedical and Environmental Sciences 2023;36(6):517-526
OBJECTIVE:
Current clinical evidence on the effects of home blood pressure telemonitoring (HBPT) on improving blood pressure control comes entirely from developed countries. Thus, we performed this randomized controlled trial to evaluate whether HBPT plus support (patient education and clinician remote hypertension management) improves blood pressure control more than usual care (UC) in the Chinese population.
METHODS:
This single-center, randomized controlled study was conducted in Beijing, China. Patients aged 30-75 years were eligible for enrolment if they had blood pressure [systolic (SBP) ≥ 140 mmHg and/or diastolic (DBP) ≥ 90 mmHg; or SBP ≥ 130 mmHg and/or DBP ≥ 80 mmHg with diabetes]. We recruited 190 patients randomized to either the HBPT or the UC groups for 12 weeks. The primary endpoints were blood pressure reduction and the proportion of patients achieving the target blood pressure.
RESULTS:
Totally, 172 patients completed the study, the HBPT plus support group ( n = 84), and the UC group ( n = 88). Patients in the plus support group showed a greater reduction in mean ambulatory blood pressure than those in the UC group. The plus support group had a significantly higher proportion of patients who achieved the target blood pressure and maintained a dipper blood pressure pattern at the 12th week of follow-up. Additionally, the patients in the plus support group showed lower blood pressure variability and higher drug adherence than those in the UC group.
CONCLUSION
HBPT plus additional support results in greater blood pressure reduction, better blood pressure control, a higher proportion of dipper blood pressure patterns, lower blood pressure variability, and higher drug adherence than UC. The development of telemedicine may be the cornerstone of hypertension management in primary care.
Humans
;
Blood Pressure
;
Blood Pressure Monitoring, Ambulatory
;
Hypertension/therapy*
;
Telemedicine/methods*
;
Hypotension
5.Blood Pressure Variability May Be a New Predictor for the Occurrence and Prognosis of Ischemic Stroke.
Ke-Qiong YAN ; Qi-Si WU ; Jun YANG
Chinese Medical Sciences Journal 2023;38(3):242-249
Despite declines in morbidity and mortality in recent years, ischemic stroke (IS) remains one of the leading causes of death and disability from cerebrovascular diseases. Addressing the controllable risk factors underpins the successful clinical management of IS. Hypertension is one of the most common treatable risk factors for IS and is associated with poor outcomes. Ambulatory blood pressure monitoring has revealed that patients with hypertension have a higher incidence of blood pressure variability (BPV) than those without hypertension. Meanwhile, increased BPV has been identified as a risk factor for IS. The risk of IS is higher and the prognosis after infarction is worse with higher BPV, no matter in the acute or subacute phase. BPV is multifactorial, with alterations reflecting individual physiological and pathological changes. This article reviews the current research advances in the relationship between BPV and IS, with an attempt to raise awareness of BPV among clinicians and IS patients, explore the increased BPV as a controllable risk factor for IS, and encourage hypertensive patients to control not only average blood pressure but also BPV and implement personalized blood pressure management.
Humans
;
Blood Pressure/physiology*
;
Ischemic Stroke/complications*
;
Blood Pressure Monitoring, Ambulatory
;
Hypertension
;
Stroke/complications*
;
Prognosis
6.Status of home blood pressure monitoring and influencing factors of regular home blood pressure monitoring among elderly uncontrolled hypertensive patients in Central and Western China.
Jia Ying LI ; Ting Xuan YANG ; Run Qing JI ; Wei LI ; Xue Ke BAI ; Jing LI ; Jia Min LIU
Chinese Journal of Cardiology 2022;50(10):1007-1013
Objective: To describe the prevalence of home blood pressure monitoring and analyze the factors influencing regular blood pressure monitoring among elderly uncontrolled hypertensive patients in Central and Western China. Methods: It was a cross-sectional study, which enrolled hypertensive patients aged over 60 years with office blood pressure ≥140/90 mmHg (1 mmHg=0.133 kPa) from September 2019 to July 2020 in 72 hospitals in Central and Western China. Patients completed the electronic questionnaires, and were divided into regular and irregular home blood pressure monitoring groups. The proportion of patients using different types of sphygmomanometers and the percentage of patients with regular home blood pressure monitoring (at least weekly) were explored. The generalized linear mixed model was used to define the influencing factors of regular home blood pressure monitoring. Results: A total of 3 857 patients were included in this study. Age was 67(64,71) years old and there were 2 163 males (56.1%). Overall, sphygmomanometer was available at home for 3 044(78.9%) patients, 2 168(56.2%) patients conducted regular home blood pressure monitoring. Among the patients with a sphygmomanometer at home, 2 370(77.9%) of the sphygmomanometers were upper arm electronic device. Older age, higher income, longer history of hypertension, multiple antihypertensive medications and awareness of diagnostic criteria of hypertension and hypertension complications were associated with a higher prevalence of regular home blood pressure monitoring (all P<0.05). Conclusions: Among the elderly hypertensive patients with uncontrolled blood pressure in Central and Western China, there is a relatively high prevalence of home sphygmomanometer ownership and regular monitoring. Age, family income, history of hypertension, number of antihypertensive drugs and knowledge of hypertension are the influencing factors of regular home blood pressure monitoring in this population.
Aged
;
Male
;
Humans
;
Middle Aged
;
Blood Pressure Monitoring, Ambulatory
;
Antihypertensive Agents/therapeutic use*
;
Cross-Sectional Studies
;
Hypertension/drug therapy*
;
Blood Pressure
;
China/epidemiology*
7.A study to identify obstructive sleep apnea syndrome based on 24 h ambulatory blood pressure data.
Jian ZHANG ; Jiaojie REN ; Shuchen SUN ; Zhengbo ZHANG
Journal of Biomedical Engineering 2022;39(1):1-9
Sleep apnea causes cardiac arrest, sleep rhythm disorders, nocturnal hypoxia and abnormal blood pressure fluctuations in patients, which eventually lead to nocturnal target organ damage in hypertensive patients. The incidence of obstructive sleep apnea hypopnea syndrome (OSAHS) is extremely high, which seriously affects the physical and mental health of patients. This study attempts to extract features associated with OSAHS from 24-hour ambulatory blood pressure data and identify OSAHS by machine learning models for the differential diagnosis of this disease. The study data were obtained from ambulatory blood pressure examination data of 339 patients collected in outpatient clinics of the Chinese PLA General Hospital from December 2018 to December 2019, including 115 patients with OSAHS diagnosed by polysomnography (PSG) and 224 patients with non-OSAHS. Based on the characteristics of clinical changes of blood pressure in OSAHS patients, feature extraction rules were defined and algorithms were developed to extract features, while logistic regression and lightGBM models were then used to classify and predict the disease. The results showed that the identification accuracy of the lightGBM model trained in this study was 80.0%, precision was 82.9%, recall was 72.5%, and the area under the working characteristic curve (AUC) of the subjects was 0.906. The defined ambulatory blood pressure features could be effectively used for identifying OSAHS. This study provides a new idea and method for OSAHS screening.
Blood Pressure
;
Blood Pressure Monitoring, Ambulatory
;
Humans
;
Hypertension/complications*
;
Polysomnography
;
Sleep Apnea, Obstructive/diagnosis*
8.Technical Difficulties in the Implementation of the Continuous Glucose Monitoring System.
Yacheng FU ; Changyun QUAN ; Lixia LIU ; Wei ZHANG
Chinese Journal of Medical Instrumentation 2022;46(4):422-427
The continuous glucose monitoring system (CGMS) has been clinically applied to monitor the dynamic change of the subcutaneous interstitial glucose concentration which is a function of the blood glucose level by glucose sensors. It can track blood glucose levels all day along, and thus provide comprehensive and reliable information about blood glucose dynamics. The clinical application of CGMS enables monitoring of blood glucose fluctuations and the discovery of hidden hyperglycemia and hypoglycemia that are difficult to be detected by traditional methods. As a CGMS needs to work subcutaneously for a long time, a series of factors such as biocompatibility, enzyme inactivation, oxygen deficiency, foreign body reaction, implant size, electrode flexibility, error correction, comfort, device toxicity, electrical safety, et al. should be considered beforehand. The study focused on the difficulties in the technology, and compared the products of Abbott, Medtronic and DexCom, then summarized their cutting-edge. Finally, this study expounded some key technologies in dynamic blood glucose monitoring and therefore can be utilized as a reference for the development of CGMS.
Blood Glucose
;
Blood Glucose Self-Monitoring/methods*
;
Humans
;
Hyperglycemia
;
Hypoglycemia
;
Monitoring, Ambulatory/methods*
;
Monitoring, Physiologic
9.Study on the quality evaluation of electrocardiogram signal in wearable physiological monitoring system.
Ning HAN ; Ke LAN ; Yuezhou ZHANG ; Tao WAN ; Zhengbo ZHANG ; Deshen CAO ; Wei YAN
Journal of Biomedical Engineering 2021;38(1):131-137
As a novel technology, wearable physiological parameter monitoring technology represents the future of monitoring technology. However, there are still many problems in the application of this kind of technology. In this paper, a pilot study was conducted to evaluate the quality of electrocardiogram (ECG) signals of the wearable physiological monitoring system (SensEcho-5B). Firstly, an evaluation algorithm of ECG signal quality was developed based on template matching method, which was used for automatic and quantitative evaluation of ECG signals. The algorithm performance was tested on a randomly selected 100 h dataset of ECG signals from 100 subjects (15 healthy subjects and 85 patients with cardiovascular diseases). On this basis, 24-hour ECG data of 30 subjects (7 healthy subjects and 23 patients with cardiovascular diseases) were collected synchronously by SensEcho-5B and ECG Holter. The evaluation algorithm was used to evaluate the quality of ECG signals recorded synchronously by the two systems. Algorithm validation results: sensitivity was 100%, specificity was 99.51%, and accuracy was 99.99%. Results of controlled test of 30 subjects: the median (Q1, Q3) of ECG signal detected by SensEcho-5B with poor signal quality time was 8.93 (0.84, 32.53) minutes, and the median (Q1, Q3) of ECG signal detected by Holter with poor signal quality time was 14.75 (4.39, 35.98) minutes (Rank sum test,
Algorithms
;
Electrocardiography
;
Electrocardiography, Ambulatory
;
Humans
;
Pilot Projects
;
Signal Processing, Computer-Assisted
;
Wearable Electronic Devices
10.Association between glycated hemoglobin and ambulatory blood pressure or heart rate in hypertensive patients.
Yuan LI ; Bin DENG ; Yuxuan GUO ; Qingling PENG ; Tao HU ; Ke XIA
Journal of Central South University(Medical Sciences) 2021;46(5):488-496
OBJECTIVES:
To determine the association between glycosylated hemoglobin (HbA1c) and ambulatory blood pressure or heart rate in hypertensive patients.
METHODS:
A total of 585 patients, who performed ambulatory blood pressure monitoring (ABPM) from September 2018 to April 2019 in Xiangya Hospital, Central South University, were enrolled and assigned into 2 groups (470 in a hypertensive group and 115 in a normal group). HbA1c levels were compared. According to the HbA1c level, the hypertensive group was divided into 2 subgroups: A high HbA1c group (HbA1c≥6.1%,
RESULTS:
The hypertensive group had higher HbA1c level than the normal group [(6.1±1.3)% vs (5.1±1.7)%,
CONCLUSIONS
In hypertensive patients, HbA1c is positively correlated with ambulate blood pressure, blood pressure load, and heart rate, and it has no correlation with blood pressure variability, heart rate variability, or morning blood pressure.
Blood Pressure
;
Blood Pressure Monitoring, Ambulatory
;
Glycated Hemoglobin A/analysis*
;
Heart Rate
;
Humans
;
Hypertension

Result Analysis
Print
Save
E-mail