1.Ultrasound-guided supraclavicular internal jugular vein compression to increase internal jugular vein cross-sectional area in hospitalized patients: a prospective observational study in Japan
Masataka HIRUMA ; Hiroyuki HONDA ; Shuichiro KURITA ; Shunsuke NUKAGA ; Mitsuhiro WATANABE ; Kei NISHIYAMA
Acute and Critical Care 2025;40(4):574-581
Background:
Real-time ultrasound-guided catheterization of the internal jugular vein (IJV) is widely used for its safety and high success rate. However, it becomes difficult when the IJV’s cross-sectional area (CSA) is reduced. A reported technique applies manual pressure (with fingers) to the supraclavicular IJV to impede venous return and enlarge the distal CSA. While effective in previous studies, its clinical utility remains unclear, as those studies involved only healthy volunteers and used blind technique. Therefore, this study aimed to evaluate the efficacy of our novel ultrasound-guided compression of the proximal IJV.
Methods:
In this prospective observational study, 25 hospitalized patients were included. Two ultrasound machines were used: one to visualize the CSA of the distal IJV, and the other to apply and guide compression of the supraclavicular IJV, ensuring real-time confirmation of venous occlusion. Patients were asked about pain during the compression procedure. The primary outcome was the degree of dilation at the puncture site of the IJV.
Results:
All 25 patients (mean Sequential Organ Failure Assessment score: 5.2±3.6) completed the study. Supraclavicular IJV compression resulted in a significant increase in the CSA of the distal IJV by approximately 150%, from 0.4±0.3 cm² to 1.0±0.3 cm² (P<0.001). No patient reported any pain during the procedure.
Conclusions
Ultrasound-guided supraclavicular IJV compression significantly increased the CSA of the distal IJV in hospitalized patients. This method enhances vein visibility by increasing IJV volume, potentially improving the success and safety of central venous catheterization.
2.Effectiveness of endoscopic ultrasound-guided tissue acquisition with stereomicroscopic on-site evaluation for preoperative diagnosis of resectable or borderline resectable pancreatic cancer: a prospective study
Junro ISHIZAKI ; Kosuke OKUWAKI ; Masafumi WATANABE ; Hiroshi IMAIZUMI ; Tomohisa IWAI ; Rikiya HASEGAWA ; Takahiro KUROSU ; Masayoshi TADEHARA ; Takaaki MATSUMOTO ; Kai ADACHI ; Taro HANAOKA ; Mitsuhiro KIDA ; Chika KUSANO
Clinical Endoscopy 2024;57(6):807-813
Background/Aims:
To validate endoscopic ultrasound-guided tissue acquisition (EUS-TA) used in conjunction with stereomicroscopic on-site evaluation (SOSE) as a preoperative diagnostic tool for resectable pancreatic cancer (R-PC) and borderline resectable PC (BR-PC).
Methods:
Seventy-eight consecutive patients who underwent EUS-TA for suspected R-PC or BR-PC were enrolled. The primary endpoint was the sensitivity of EUS-TA together with SOSE based on the stereomicroscopically visible white core (SVWC) cutoff value. One or two sites were punctured by using a 22-gauge biopsy needle for EUS-TA, based on the SOSE findings.
Results:
We collected 99 specimens from 56 and 22 patients with R-PC and BR-PC, respectively. Based on the SOSE results, we performed 57 procedures with one puncture. The SVWC cutoff values were met in 73.7% and 73.1% of all specimens and in those obtained during the first puncture, respectively. The final diagnoses were malignant and benign tumors in 76 and two patients, respectively. The overall sensitivity, specificity, and accuracy of EUS-TA for the 78 lesions were 90.8%, 100%, and 91.0%, respectively. The sensitivity for malignant diagnosis based on the SVWC cutoff value were 89.5% and 90.4% for the first puncture and all specimens, respectively.
Conclusions
The sensitivity of EUS-TA in conjunction with SOSE for malignancy diagnosis in patients with suspected R-PC or BR-PC was 90.4%.
3.Effectiveness of endoscopic ultrasound-guided tissue acquisition with stereomicroscopic on-site evaluation for preoperative diagnosis of resectable or borderline resectable pancreatic cancer: a prospective study
Junro ISHIZAKI ; Kosuke OKUWAKI ; Masafumi WATANABE ; Hiroshi IMAIZUMI ; Tomohisa IWAI ; Rikiya HASEGAWA ; Takahiro KUROSU ; Masayoshi TADEHARA ; Takaaki MATSUMOTO ; Kai ADACHI ; Taro HANAOKA ; Mitsuhiro KIDA ; Chika KUSANO
Clinical Endoscopy 2024;57(6):807-813
Background/Aims:
To validate endoscopic ultrasound-guided tissue acquisition (EUS-TA) used in conjunction with stereomicroscopic on-site evaluation (SOSE) as a preoperative diagnostic tool for resectable pancreatic cancer (R-PC) and borderline resectable PC (BR-PC).
Methods:
Seventy-eight consecutive patients who underwent EUS-TA for suspected R-PC or BR-PC were enrolled. The primary endpoint was the sensitivity of EUS-TA together with SOSE based on the stereomicroscopically visible white core (SVWC) cutoff value. One or two sites were punctured by using a 22-gauge biopsy needle for EUS-TA, based on the SOSE findings.
Results:
We collected 99 specimens from 56 and 22 patients with R-PC and BR-PC, respectively. Based on the SOSE results, we performed 57 procedures with one puncture. The SVWC cutoff values were met in 73.7% and 73.1% of all specimens and in those obtained during the first puncture, respectively. The final diagnoses were malignant and benign tumors in 76 and two patients, respectively. The overall sensitivity, specificity, and accuracy of EUS-TA for the 78 lesions were 90.8%, 100%, and 91.0%, respectively. The sensitivity for malignant diagnosis based on the SVWC cutoff value were 89.5% and 90.4% for the first puncture and all specimens, respectively.
Conclusions
The sensitivity of EUS-TA in conjunction with SOSE for malignancy diagnosis in patients with suspected R-PC or BR-PC was 90.4%.
4.Effectiveness of endoscopic ultrasound-guided tissue acquisition with stereomicroscopic on-site evaluation for preoperative diagnosis of resectable or borderline resectable pancreatic cancer: a prospective study
Junro ISHIZAKI ; Kosuke OKUWAKI ; Masafumi WATANABE ; Hiroshi IMAIZUMI ; Tomohisa IWAI ; Rikiya HASEGAWA ; Takahiro KUROSU ; Masayoshi TADEHARA ; Takaaki MATSUMOTO ; Kai ADACHI ; Taro HANAOKA ; Mitsuhiro KIDA ; Chika KUSANO
Clinical Endoscopy 2024;57(6):807-813
Background/Aims:
To validate endoscopic ultrasound-guided tissue acquisition (EUS-TA) used in conjunction with stereomicroscopic on-site evaluation (SOSE) as a preoperative diagnostic tool for resectable pancreatic cancer (R-PC) and borderline resectable PC (BR-PC).
Methods:
Seventy-eight consecutive patients who underwent EUS-TA for suspected R-PC or BR-PC were enrolled. The primary endpoint was the sensitivity of EUS-TA together with SOSE based on the stereomicroscopically visible white core (SVWC) cutoff value. One or two sites were punctured by using a 22-gauge biopsy needle for EUS-TA, based on the SOSE findings.
Results:
We collected 99 specimens from 56 and 22 patients with R-PC and BR-PC, respectively. Based on the SOSE results, we performed 57 procedures with one puncture. The SVWC cutoff values were met in 73.7% and 73.1% of all specimens and in those obtained during the first puncture, respectively. The final diagnoses were malignant and benign tumors in 76 and two patients, respectively. The overall sensitivity, specificity, and accuracy of EUS-TA for the 78 lesions were 90.8%, 100%, and 91.0%, respectively. The sensitivity for malignant diagnosis based on the SVWC cutoff value were 89.5% and 90.4% for the first puncture and all specimens, respectively.
Conclusions
The sensitivity of EUS-TA in conjunction with SOSE for malignancy diagnosis in patients with suspected R-PC or BR-PC was 90.4%.
5.Stereomicroscopic on-site evaluation in endoscopic ultrasound-guided tissue acquisition of upper gastrointestinal subepithelial lesions
Seigo NAKATANI ; Kosuke OKUWAKI ; Masafumi WATANABE ; Hiroshi IMAIZUMI ; Tomohisa IWAI ; Takaaki MATSUMOTO ; Rikiya HASEGAWA ; Hironori MASUTANI ; Takahiro KUROSU ; Akihiro TAMAKI ; Junro ISHIZAKI ; Ayana ISHIZAKI ; Mitsuhiro KIDA ; Chika KUSANO
Clinical Endoscopy 2024;57(1):89-95
Background/Aims:
In stereomicroscopic sample isolation processing, the cutoff value (≥4 mm) of stereomicroscopically visible white cores indicates high diagnostic sensitivity. We aimed to evaluate endoscopic ultrasound-guided tissue acquisition (EUS-TA) using a simplified stereomicroscopic on-site evaluation of upper gastrointestinal subepithelial lesions (SELs).
Methods:
In this multicenter prospective trial, we performed EUS-TA using a 22-gauge Franseen needle in 34 participants with SELs derived from the upper gastrointestinal muscularis propria, requiring pathological diagnosis. The presence of stereomicroscopically visible white core (SVWC) in each specimen was assessed using stereomicroscopic on-site evaluation. The primary outcome was EUS-TA’s diagnostic sensitivity with stereomicroscopic on-site evaluation based on the SVWC cutoff value (≥4 mm) for malignant upper gastrointestinal SELs.
Results:
The total number of punctures was 68; 61 specimens (89.7%) contained stereomicroscopically visible white cores ≥4 mm in size. The final diagnoses were gastrointestinal stromal tumor, leiomyoma, and schwannoma in 76.5%, 14.7%, and 8.8% of the cases, respectively. The sensitivity of EUS-TA with stereomicroscopic on-site evaluation based on the SVWC cutoff value for malignant SELs was 100%. The per-lesion accuracy of histological diagnosis reached the highest level (100%) at the second puncture.
Conclusions
Stereomicroscopic on-site evaluation showed high diagnostic sensitivity and could be a new method for diagnosing upper gastrointestinal SELs using EUS-TA.
6.Efficacy and safety of a new vedolizumab subcutaneous formulation in Japanese patients with moderately to severely active ulcerative colitis
Taku KOBAYASHI ; Hiroaki ITO ; Toshifumi ASHIDA ; Tadashi YOKOYAMA ; Masakazu NAGAHORI ; Tomoki INABA ; Mitsuhiro SHIKAMURA ; Takayoshi YAMAGUCHI ; Tetsuharu HORI ; Philippe PINTON ; Mamoru WATANABE ; Toshifumi HIBI
Intestinal Research 2021;19(4):448-460
Background/Aims:
A subgroup analysis was conducted in Japanese patients with moderate to severe ulcerative colitis (UC) enrolled in the phase 3 VISIBLE 1 study, which evaluated the safety and efficacy of a new vedolizumab subcutaneous (SC) formulation.
Methods:
Eligible patients received open-label infusions of vedolizumab 300 mg intravenous (IV) at weeks 0 and 2 in the induction phase. Patients with clinical response by complete Mayo score at week 6 entered the double-blind maintenance phase and were randomized to vedolizumab 108 mg SC every 2 weeks, placebo, or vedolizumab 300 mg IV every 8 weeks. The primary endpoint was clinical remission (complete Mayo score ≤ 2 points; no individual subscore > 1 point) at week 52.
Results:
Of 49 patients who entered the induction phase, 22 out of 49 patients (45%) had clinical response at week 6 and were randomized to vedolizumab 108 mg SC (n = 10), placebo (n = 10), or vedolizumab 300 mg IV (n = 2). At week 52, 4 out of 10 patients (40%) who received vedolizumab SC had clinical remission versus 2 out of 10 patients (20%) who received placebo (difference: 20% [95% confidence interval, –27.9 to 61.8]). Two patients (2/10, 20%) who received vedolizumab SC experienced an injection-site reaction versus none who received placebo.
Conclusions
Our results indicate that the efficacy of vedolizumab SC in a subgroup of Japanese patients with UC are similar with those in the overall VISIBLE 1 study population, and with those established with vedolizumab IV. The safety and tolerability of vedolizumab SC were generally similar to that established for vedolizumab IV. (ClinicalTrials.gov ID NCT02611830; EudraCT 2015-000480-14)
7.Cholecystitis after Placement of Covered Self-Expandable Metallic Stents in Patients with Distal Malignant Biliary Obstructions
Masafumi WATANABE ; Kosuke OKUWAKI ; Jun WOO ; Mitsuhiro KIDA ; Hiroshi IMAIZUMI ; Tomohisa IWAI ; Hiroshi YAMAUCHI ; Toru KANEKO ; Rikiya HASEGAWA ; Takahiro KUROSU ; Naoki MINATO ; Hiroki HARADOME ; Wasaburo KOIZUMI
Clinical Endoscopy 2021;54(4):589-595
Background/Aims:
Cholecystitis can occur after the placement of covered self-expandable metallic stents for distal malignant biliary obstructions. We aimed to identify risk factors for cholecystitis following covered self-expandable metallic stent placement.
Methods:
We investigated risk factors related to cholecystitis following covered self-expandable metallic stent placement in 118 patients with distal malignant biliary obstructions between January 1, 2015 and April 30, 2019. Endoscopic assessments and tumor invasion to the arteries feeding the gallbladder were determined by a pancreaticobiliary endoscopist and a radiologist, respectively.
Results:
The median patient age was 72 years (men, 61.0%). The flow of the contrast agent into the gallbladder and tumor involvement in the orifice of the cystic duct were observed in 35 (29.7%) and 35 (29.7%) patients, respectively. During the observation period (median, 179 days), cholecystitis occurred in 18 (15.3%) patients. Multivariate analysis revealed the flow of the contrast agent into the gallbladder (p=0.023) and tumor involvement in the orifice of the cystic duct (p=0.005) as significant independent risk factors associated with cholecystitis.
Conclusions
The flow of the contrast agent into the gallbladder and tumor involvement in the orifice of the cystic duct are potential independent risk factors for cholecystitis following the placement of covered self-expandable metallic stents. A follow-up prospective study is warranted to validate their influence.
8.Cholecystitis after Placement of Covered Self-Expandable Metallic Stents in Patients with Distal Malignant Biliary Obstructions
Masafumi WATANABE ; Kosuke OKUWAKI ; Jun WOO ; Mitsuhiro KIDA ; Hiroshi IMAIZUMI ; Tomohisa IWAI ; Hiroshi YAMAUCHI ; Toru KANEKO ; Rikiya HASEGAWA ; Takahiro KUROSU ; Naoki MINATO ; Hiroki HARADOME ; Wasaburo KOIZUMI
Clinical Endoscopy 2021;54(4):589-595
Background/Aims:
Cholecystitis can occur after the placement of covered self-expandable metallic stents for distal malignant biliary obstructions. We aimed to identify risk factors for cholecystitis following covered self-expandable metallic stent placement.
Methods:
We investigated risk factors related to cholecystitis following covered self-expandable metallic stent placement in 118 patients with distal malignant biliary obstructions between January 1, 2015 and April 30, 2019. Endoscopic assessments and tumor invasion to the arteries feeding the gallbladder were determined by a pancreaticobiliary endoscopist and a radiologist, respectively.
Results:
The median patient age was 72 years (men, 61.0%). The flow of the contrast agent into the gallbladder and tumor involvement in the orifice of the cystic duct were observed in 35 (29.7%) and 35 (29.7%) patients, respectively. During the observation period (median, 179 days), cholecystitis occurred in 18 (15.3%) patients. Multivariate analysis revealed the flow of the contrast agent into the gallbladder (p=0.023) and tumor involvement in the orifice of the cystic duct (p=0.005) as significant independent risk factors associated with cholecystitis.
Conclusions
The flow of the contrast agent into the gallbladder and tumor involvement in the orifice of the cystic duct are potential independent risk factors for cholecystitis following the placement of covered self-expandable metallic stents. A follow-up prospective study is warranted to validate their influence.
9.Retrospective surveillance of metabolic parameters affecting reproductive performance of Japanese Black breeding cows.
Urara WATANABE ; Mitsuhiro TAKAGI ; Osamu YAMATO ; Takeshige OTOI ; Koji OKAMOTO
Journal of Veterinary Science 2014;15(2):283-288
This retrospective study was conducted to confirm the relationship between pre- and postpartum metabolic parameters and postpartum reproductive performance and to clarify seasonal characteristics of the metabolic parameters by using our metabolic profile test (MPT) database of Japanese Black breeding herds. In evaluation 1, MPT databases of blood samples from multiparous cows collected prepartum and postpartum were divided into two groups according to calving interval, and each MPT parameter was compared. In evaluation 2, the same MPT databases used in evaluation 1 were divided into two groups according to the sampling period. Significant differences were found in the prepartal total protein and postpartal gamma-glutamyltransferase in evaluation 1. In evaluation 2, significant differences were found in the prepartal and postpartal total protein, albumin/globulin ratio, and glucose. Clear seasonal differences in MPT results emphasized the usefulness of the MPT in breeding cattle herds fed home-pasture roughage and suggest that unsatisfactory reproductive performance during hot periods reflects inadequate nutritional content of the diet and possible reduced feed intake due to heat stress.
Animals
;
Blood Proteins/analysis
;
Cattle/*physiology
;
Diet/veterinary
;
Dietary Fiber/analysis
;
Female
;
Heat Stress Disorders
;
*Metabolome
;
Postpartum Period
;
*Reproduction
;
Retrospective Studies
;
Seasons
10.Recent Advances of Biliary Stent Management.
Mitsuhiro KIDA ; Shiro MIYAZAWA ; Tomohisa IWAI ; Hiroko IKEDA ; Miyoko TAKEZAWA ; Hidehiko KIKUCHI ; Maya WATANABE ; Hiroshi IMAIZUMI ; Wasaburo KOIZUMI
Korean Journal of Radiology 2012;13(Suppl 1):S62-S66
Recent progress in chemotherapy has prolonged the survival of patients with malignant biliary strictures, leading to increased rates of stent occlusion. Even we employed metallic stents which contributed to higher rates and longer durations of patency, and occlusion of covered metallic stents now occurs in about half of all patients during their survival. We investigated the complication and patency rate for the removal of covered metallic stents, and found that the durations were similar for initial stent placement and re-intervention. In order to preserve patient quality of life, we currently recommend the use of covered metallic stents for patients with malignant biliary obstruction because of their removability and longest patency duration, even though uncovered metallic stents have similar patency durations.
Biliary Tract Diseases/*surgery
;
Coated Materials, Biocompatible
;
Device Removal
;
Drainage/methods
;
Endoscopy
;
Foreign-Body Migration/surgery
;
Humans
;
Metals
;
Postoperative Complications/surgery
;
*Stents/adverse effects

Result Analysis
Print
Save
E-mail