1.Safety and Tolerability of Wharton’s Jelly-Derived Mesenchymal Stem Cells for Patients With Duchenne Muscular Dystrophy: A Phase 1 Clinical Study
Jiwon LEE ; Sang Eon PARK ; Mira KIM ; Hyeongseop KIM ; Jeong-Yi KWON ; Hong Bae JEON ; Jong Wook CHANG ; Jeehun LEE
Journal of Clinical Neurology 2025;21(1):40-52
Background:
and Purpose This study was an open-label, dose-escalation, phase 1 clinical trial to determine the safety and dose of EN001 for patients with Duchenne muscular dystrophy (DMD). EN001, developed by ENCell, are allogeneic early-passage Wharton’s jelly-derived mesenchymal stem cells that originate at the umbilical cord, with preclinical studies demonstrating their high therapeutic efficacy for DMD.
Methods:
This phase 1 clinical trial explored the safety and tolerability of EN001 as a potential treatment option for patients with DMD. Six pediatric participants with DMD were divided into two subgroups of equal size: low-dose EN001 (5.0×105 cells/kg) and high-dose EN001 (2.5×106 cells/kg). All participants were monitored for 12 weeks after EN001 administration to assess its safety. Dose-limiting toxicity (DLT) was evaluated across 2 weeks post administration. Exploratory efficacy was evaluated by measuring serum creatine kinase levels, and functional evaluations—including spirometry, myometry, the North Star Ambulatory Assessment, and the 6-minute walk test—were conducted at week 12 and compared with the baseline values.
Results:
No participants experienced serious adverse events related to EN001 injection during the 12-week follow-up period. Mild adverse events included injection-related local erythema, edema, parosmia, and headache, but DLT was not observed. Functional evaluations at week 12 revealed no significant changes from baseline.
Conclusions
These results demonstrated that EN001 are safe and well tolerated for patients with DMD, and did not cause serious adverse events. The efficacy of EN001 could be confirmed through larger-scale future studies that incorporate repeated dosing and have a randomized controlled trial design.
2.Safety and Tolerability of Wharton’s Jelly-Derived Mesenchymal Stem Cells for Patients With Duchenne Muscular Dystrophy: A Phase 1 Clinical Study
Jiwon LEE ; Sang Eon PARK ; Mira KIM ; Hyeongseop KIM ; Jeong-Yi KWON ; Hong Bae JEON ; Jong Wook CHANG ; Jeehun LEE
Journal of Clinical Neurology 2025;21(1):40-52
Background:
and Purpose This study was an open-label, dose-escalation, phase 1 clinical trial to determine the safety and dose of EN001 for patients with Duchenne muscular dystrophy (DMD). EN001, developed by ENCell, are allogeneic early-passage Wharton’s jelly-derived mesenchymal stem cells that originate at the umbilical cord, with preclinical studies demonstrating their high therapeutic efficacy for DMD.
Methods:
This phase 1 clinical trial explored the safety and tolerability of EN001 as a potential treatment option for patients with DMD. Six pediatric participants with DMD were divided into two subgroups of equal size: low-dose EN001 (5.0×105 cells/kg) and high-dose EN001 (2.5×106 cells/kg). All participants were monitored for 12 weeks after EN001 administration to assess its safety. Dose-limiting toxicity (DLT) was evaluated across 2 weeks post administration. Exploratory efficacy was evaluated by measuring serum creatine kinase levels, and functional evaluations—including spirometry, myometry, the North Star Ambulatory Assessment, and the 6-minute walk test—were conducted at week 12 and compared with the baseline values.
Results:
No participants experienced serious adverse events related to EN001 injection during the 12-week follow-up period. Mild adverse events included injection-related local erythema, edema, parosmia, and headache, but DLT was not observed. Functional evaluations at week 12 revealed no significant changes from baseline.
Conclusions
These results demonstrated that EN001 are safe and well tolerated for patients with DMD, and did not cause serious adverse events. The efficacy of EN001 could be confirmed through larger-scale future studies that incorporate repeated dosing and have a randomized controlled trial design.
3.Safety and Tolerability of Wharton’s Jelly-Derived Mesenchymal Stem Cells for Patients With Duchenne Muscular Dystrophy: A Phase 1 Clinical Study
Jiwon LEE ; Sang Eon PARK ; Mira KIM ; Hyeongseop KIM ; Jeong-Yi KWON ; Hong Bae JEON ; Jong Wook CHANG ; Jeehun LEE
Journal of Clinical Neurology 2025;21(1):40-52
Background:
and Purpose This study was an open-label, dose-escalation, phase 1 clinical trial to determine the safety and dose of EN001 for patients with Duchenne muscular dystrophy (DMD). EN001, developed by ENCell, are allogeneic early-passage Wharton’s jelly-derived mesenchymal stem cells that originate at the umbilical cord, with preclinical studies demonstrating their high therapeutic efficacy for DMD.
Methods:
This phase 1 clinical trial explored the safety and tolerability of EN001 as a potential treatment option for patients with DMD. Six pediatric participants with DMD were divided into two subgroups of equal size: low-dose EN001 (5.0×105 cells/kg) and high-dose EN001 (2.5×106 cells/kg). All participants were monitored for 12 weeks after EN001 administration to assess its safety. Dose-limiting toxicity (DLT) was evaluated across 2 weeks post administration. Exploratory efficacy was evaluated by measuring serum creatine kinase levels, and functional evaluations—including spirometry, myometry, the North Star Ambulatory Assessment, and the 6-minute walk test—were conducted at week 12 and compared with the baseline values.
Results:
No participants experienced serious adverse events related to EN001 injection during the 12-week follow-up period. Mild adverse events included injection-related local erythema, edema, parosmia, and headache, but DLT was not observed. Functional evaluations at week 12 revealed no significant changes from baseline.
Conclusions
These results demonstrated that EN001 are safe and well tolerated for patients with DMD, and did not cause serious adverse events. The efficacy of EN001 could be confirmed through larger-scale future studies that incorporate repeated dosing and have a randomized controlled trial design.
4.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
Purpose:
This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard.
Methods:
This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses.
Results:
TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710).
Conclusion
QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups.
5.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
Purpose:
This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard.
Methods:
This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses.
Results:
TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710).
Conclusion
QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups.
6.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
Purpose:
This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard.
Methods:
This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses.
Results:
TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710).
Conclusion
QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups.
7.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
Purpose:
This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard.
Methods:
This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses.
Results:
TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710).
Conclusion
QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups.
8.Diagnostic performance of quantitative ultrasonography for hepatic steatosis in a health screening program: a prospective single-center study
Jeung Hui PYO ; Soo Jin CHO ; Sung Chul CHOI ; Jae Hwan JEE ; Jeeyeong YUN ; Jeong Ah HWANG ; Goeun PARK ; Kyunga KIM ; Wonseok KANG ; Mira KANG ; Young hye BYUN
Ultrasonography 2024;43(4):250-262
Purpose:
This study compared the diagnostic performance of quantitative ultrasonography (QUS) with that of conventional ultrasonography (US) in assessing hepatic steatosis among individuals undergoing health screening using magnetic resonance imaging–derived proton density fat fraction (MRI-PDFF) as the reference standard.
Methods:
This single-center prospective study enrolled 427 participants who underwent abdominal MRI and US. Measurements included the attenuation coefficient in tissue attenuation imaging (TAI) and the scatter-distribution coefficient in tissue scatter-distribution imaging (TSI). The correlation between QUS and MRI-PDFF was evaluated. The diagnostic capabilities of QUS, conventional B-mode US, and their combined models for detecting hepatic fat content of ≥5% (MRI-PDFF ≥5%) and ≥10% (MRI-PDFF ≥10%) were compared by analyzing the areas under the receiver operating characteristic curves. Additionally, clinical risk factors influencing the diagnostic performance of QUS were identified using multivariate linear regression analyses.
Results:
TAI and TSI were strongly correlated with MRI-PDFF (r=0.759 and r=0.802, respectively; both P<0.001) and demonstrated good diagnostic performance in detecting and grading hepatic steatosis. The combination of QUS and B-mode US resulted in the highest areas under the ROC curve (AUCs) (0.947 and 0.975 for detecting hepatic fat content of ≥5% and ≥10%, respectively; both P<0.05), compared to TAI, TSI, or B-mode US alone (AUCs: 0.887, 0.910, 0.878 for ≥5% and 0.951, 0.922, 0.875 for ≥10%, respectively). The independent determinants of QUS included skinliver capsule distance (β=7.134), hepatic fibrosis (β=4.808), alanine aminotransferase (β=0.202), triglyceride levels (β=0.027), and diabetes mellitus (β=3.710).
Conclusion
QUS is a useful and effective screening tool for detecting and grading hepatic steatosis during health checkups.
9.Prognostic Impact of Elevation of Cancer Antigen 15-3 (CA15-3) in Patients With Early Breast Cancer With Normal Serum CA15-3 Level
Jai Min RYU ; Danbee KANG ; Juhee CHO ; Jeong Eon LEE ; Seok Won KIM ; Seok Jin NAM ; Se Kyung LEE ; Yeon Jin KIM ; Young-Hyuck IM ; Jin Seok AHN ; Yeon Hee PARK ; Ji-Yeon KIM ; Hyunjong LEE ; Mira KANG ; Jong Han YU
Journal of Breast Cancer 2023;26(2):126-135
Purpose:
Cancer antigen 15-3 (CA15-3) is a serum tumor marker for breast cancer (BC) extensively used in clinical practice. CA15-3 is non-invasive, easily available, and a costeffective tumor marker for immediate diagnosis, monitoring and prediction of BC recurrence. We hypothesized that an elevation of CA15-3 may have prognostic impact in patients with early BC with normal serum CA15-3 level.
Methods:
This was a retrospective cohort study, which included patients with BC who received curative surgery at a comprehensive single institution between 2000 and 2016.CA15-3 levels from 0 to 30 U/mL were considered normal, and patients who had CA15-3 > 30 U/mL, were excluded from the study.
Results:
The mean age of study participants (n = 11,452) was 49.3 years. The proportion of participants with elevated CA15-3 ≥ 1 standard deviation (SD) compared with the previous examination during follow-up was 23.3% (n = 2,666). During the follow-up (median followup 5.8 years), 790 patients experienced recurrence. The fully-adjusted hazard ratio (HR) for recurrence comparing participants with stable CA15-3 level to subjects with elevated CA15-3 level was 1.76 (95% confidence interval [CI], 1.52–2.03). In addition, if the CA15-3was elevated ≥ 1 SD, the risk was much higher (HR, 6.87; 95% CI, 5.81–8.11) than in patients without elevated CA15-3 ≥ 1 SD. In sensitivity analysis, the recurrence risk was consistently higher in participants with elevated CA15-3 levels than in participants without elevated CA15-3 levels. The association between elevated CA15-3 levels and incidence of recurrence was observed in all subtypes and the association was stronger in patients with N+ than in patients with N0 stage (p-value for interaction < 0.01).
Conclusion
The results of the present study demonstrated that elevation of CA15-3 in patients with early BC and initial normal serum CA15-3 levels has a prognostic impact.
10.A Median Arcuate Ligament Syndrome Could Be Re-termed as a Nutcracker Celiac Ganglion Abdominal Pain Syndrome
Ji Eun KIM ; Mira KANG ; Ok Soon JEONG ; Poong-Lyul RHEE
Journal of Neurogastroenterology and Motility 2023;29(2):200-207
Background/Aims:
Median arcuate ligament syndrome (MALS) is known as chronic recurrent abdominal pain related to compression of the celiac artery by the median arcuate ligament. We aim to seek the specific mechanism of the pain by evaluating symptoms and radiological characteristics on abdominal CT scans.
Methods:
We analyzed 35 patients who visited the emergency room for recurrent abdominal pain after cholecystectomy. We classified the characteristics of patients as 4 clinical components and 2 radiological components. We defined the sum of weighted clinical scores and weighted radiological scores as nutcracker ganglion abdominal pain syndrome (NCGAPS) scores. We categorized the patients into 3 groups classified by the degree of NCGAPS scores. The 3 patients with top-3 NCGAPS scores were recommended for CT angiography.
Results:
When the suspicion was graded by NCGAPS scores, post stenotic dilatation was significantly different among all groups (P < 0.001).The clinical components of pain varied positional or respirational change and continuous pain were significantly different among all the groups (P < 0.01). NCGAPS scores can remarkably differentiate highly suspicious patients in comparison to simply combined scores. Only 1 patient in the highly suspicious group by NCGAPS scores took the CT angiography and was confirmed with NCGAPS.
Conclusions
We suggest renaming MALS as NCGAPS, nutcracker celiac ganglion abdominal pain syndrome, to better explain the mechanism of the recurrent abdominal pain. Further studies on the diagnostic cutoff of clinical and radiological scores of NCGAPS are needed not to miss the diagnosis of NCGAPS.

Result Analysis
Print
Save
E-mail