1.One-year outcomes of a novel domestic transcatheter aortic valve system in severe aortic stenosis: a multicenter cohort study
Yuehuan LI ; Jiawei ZHOU ; Lai WEI ; Yingqiang GUO ; Liang MA ; Huiming GUO ; Xiangbin PAN ; Dongjin WANG ; Fanyan LUO ; Jue WANG ; Minxin WEI ; Deguang FENG ; Yingbin XIAO ; Liming LIU ; Jian′an WANG ; Jiangang WANG ; Haibo ZHANG
Chinese Journal of Surgery 2025;63(11):1052-1058
Objective:To examine the safety and effectiveness of a novel domestic transcatheter aortic valve system in addressing severe aortic valve stenosis.Methods:This prospective, multicenter, single-arm target-value clinical trial enrolled patients with severe aortic stenosis meeting inclusion criteria from 13 Chinese centers between July 2021 and April 2022. The primary endpoint was all-cause mortality at 1-year post-procedure. Secondary endpoints included safety outcomes (30-day all-cause mortality, 1-year major adverse cardiovascular events, device success) and efficacy parameters (transvalvular pressure gradient, paravalvular leak severity, New York Heart Association(NYHA)class improvement, and quality of life). Survival analysis was performed using the Kaplan-Meier analysis.Results:The study included 134 patients, 85 males and 49 females, with an age of (73.6±5.6)years (range: 65.1 to 91.8 years). Bicuspid aortic valve morphology was present in 59.7% (80/134). Device success rate was 99.3%, with one case converted to open surgery due to coronary obstruction. All-cause mortality was 0.8% (95% CI: 0.1% to 5.3%) at both 30-day and 1-year follow-up, significantly lower than the 25% target value ( P<0.01). Permanent pacemaker implantation rates remained 2.2% (3/134) at both timepoints. Stroke incidence was 0.7% (1/134) at 30 days and 1.5% (2/134) at 1 year. Myocardial infarction rates were 0.7% (1/134) at both intervals. The postoperative transvalvular pressure gradient of the aortic valve was (6.6±3.1) mmHg(1 mmHg=0.133 kPa) (range: 4 to 8 mmHg). Among the patients, 32 cases (23.9%) had mild paravalvular leakage, 4 cases (3.0%) had moderate paravalvular leakage, and no severe paravalvular leakage was observed. NYHA class Ⅰ and Ⅱ patients increased from 18.7% preoperatively to 99.3% postoperatively. Conclusion:The novel domestic transcatheter aortic valve system demonstrates satisfactory 1-year safety and efficacy outcomes in treating severe aortic stenosis.
2.One-year outcomes of a novel domestic transcatheter aortic valve system in severe aortic stenosis: a multicenter cohort study
Yuehuan LI ; Jiawei ZHOU ; Lai WEI ; Yingqiang GUO ; Liang MA ; Huiming GUO ; Xiangbin PAN ; Dongjin WANG ; Fanyan LUO ; Jue WANG ; Minxin WEI ; Deguang FENG ; Yingbin XIAO ; Liming LIU ; Jian′an WANG ; Jiangang WANG ; Haibo ZHANG
Chinese Journal of Surgery 2025;63(11):1052-1058
Objective:To examine the safety and effectiveness of a novel domestic transcatheter aortic valve system in addressing severe aortic valve stenosis.Methods:This prospective, multicenter, single-arm target-value clinical trial enrolled patients with severe aortic stenosis meeting inclusion criteria from 13 Chinese centers between July 2021 and April 2022. The primary endpoint was all-cause mortality at 1-year post-procedure. Secondary endpoints included safety outcomes (30-day all-cause mortality, 1-year major adverse cardiovascular events, device success) and efficacy parameters (transvalvular pressure gradient, paravalvular leak severity, New York Heart Association(NYHA)class improvement, and quality of life). Survival analysis was performed using the Kaplan-Meier analysis.Results:The study included 134 patients, 85 males and 49 females, with an age of (73.6±5.6)years (range: 65.1 to 91.8 years). Bicuspid aortic valve morphology was present in 59.7% (80/134). Device success rate was 99.3%, with one case converted to open surgery due to coronary obstruction. All-cause mortality was 0.8% (95% CI: 0.1% to 5.3%) at both 30-day and 1-year follow-up, significantly lower than the 25% target value ( P<0.01). Permanent pacemaker implantation rates remained 2.2% (3/134) at both timepoints. Stroke incidence was 0.7% (1/134) at 30 days and 1.5% (2/134) at 1 year. Myocardial infarction rates were 0.7% (1/134) at both intervals. The postoperative transvalvular pressure gradient of the aortic valve was (6.6±3.1) mmHg(1 mmHg=0.133 kPa) (range: 4 to 8 mmHg). Among the patients, 32 cases (23.9%) had mild paravalvular leakage, 4 cases (3.0%) had moderate paravalvular leakage, and no severe paravalvular leakage was observed. NYHA class Ⅰ and Ⅱ patients increased from 18.7% preoperatively to 99.3% postoperatively. Conclusion:The novel domestic transcatheter aortic valve system demonstrates satisfactory 1-year safety and efficacy outcomes in treating severe aortic stenosis.
3.Comparison of Volatile Oil of Atractylodis Rhizoma and Atractylodis Macrocephalae Rhizoma before and after Co-Decocting by Using GC-MS
Baohong SONG ; Xuemei TANG ; Minxin MA ; Wei WANG ; Yuanyuan JIANG ; Hui AO ; Lu CHEN
World Science and Technology-Modernization of Traditional Chinese Medicine 2023;25(11):3585-3591
Objective To study the changes of volatile oil of Atractylodis Rhizoma(AR)and Atractylodis macrocephalae Rhizoma(AMR)before and after co-decocting in different proportions(1∶3,1∶2,1∶1,2∶1,3∶1).Methods The volatile oil was extracted by steam distillation and analyzed by gas chromatography-mass spectrometry(GC-MS).Results After co-decocting,the yield of volatile in each group was higher than in single decocting.The relative contents of most components in the mixed volatile oil after co-decocting were significantly different from the theoretical calculation.Co-decocting could promote the extraction of hinesol,which is the main component of the essential oil of AR,and the compatibility with large doses of AMR(1∶2 and 1∶3)could also promote the dissolution of β-eudesmol.At the same time,the extraction of atractylon,germacrene B and valencene was inhibited by co-decocting,which were the main constituents of the volatile oil of AMR.Conclusion Co-decocting of AR and AMR could improve the extraction rate and change the chemical composition of volatile oil.After co-decocting,the dissolution of active components of AR increased,while the dissolution of active components of AMR decreased.It may lead to the change of pharmacological activity.

Result Analysis