1.Korean colorectal cancer screening guidelines for asymptomatic, average-risk adults: the 2025 revision
EunKyo KANG ; Jae Myung CHA ; Seo Young KANG ; Kiheon LEE ; Su Young KIM ; Younghoon KIM ; An Na SEO ; Hyo-Jin KANG ; Jong Keon JANG ; Kwang-Pil KO ; Aesun SHIN ; Dae Kyung SOHN ; Youngki HONG ; Eun-Jung CHO ; Minje HAN ; Soo Young KIM ; Hyeon Ji LEE ; Chang Kyun CHOI ; Mina SUH
Journal of the Korean Medical Association 2026;69(3):268-280
Purpose:
To develop the 2025 update to the Korean colorectal cancer (CRC) screening guidelines by systematically evaluating recent evidence, integrating domestic data, and addressing changes since the 2015 guideline revision, thereby providing an evidence-based standard for clinicians and policymakers.
Methods:
A multidisciplinary committee developed the guidelines using the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) methodology. The process included formulation of three key questions addressing screening efficacy, diagnostic accuracy, and optimal screening age and interval. A systematic review of international guidelines and primary literature was conducted, yielding 327 eligible studies. In addition, a utility-based analysis using a Markov model was performed to determine optimal screening ages and intervals.
Results:
The evidence synthesis identified high-certainty evidence supporting the use of the fecal immunochemical test (FIT) for reducing CRC mortality and moderate-certainty evidence for colonoscopy. Evidence for computed tomographic colonography (CTC) and stool DNA testing was rated as very low certainty. Based on the evidence review and cost-utility analysis, the committee conditionally recommends CRC screening for asymptomatic, average-risk adults aged 45–74 years using either colonoscopy every 10 years or FIT every 1–2 years. CTC and stool DNA testing were not recommended owing to insufficient evidence.
Conclusion
The 2025 Korean Guidelines for Colorectal Cancer Screening present updated, evidence-based recommendations tailored to the domestic healthcare context. By conditionally endorsing both colonoscopy and FIT for individuals aged 45–74 years, these guidelines aim to improve population-level screening effectiveness and reduce the burden of CRC in South Korea.
2.Recent Applications of Lung Organoid and Lung-on-a-Chip Technologies for Evaluating the Toxicity of Fine Particulate Matter
Minje KANG ; Ji-Young KIM ; Chan Woo KWON ; Woo Jin KIM ; Seok-Ho HONG
International Journal of Stem Cells 2025;18(4):357-367
There is mounting epidemiologic and experimental evidence of the harmful effects of exposure to fine particulate matter (PM2.5) on human lung health. However, the current utilization of in vitro two-dimensional (2D) cell culture and in vivo animal models falls short in accurately recapitulating the complexity, functions, and development of the human lung. Recently, technologies for creating 3D biomimetic lung organoids from human tissue and pluripotent stem cells that mimic the structure and function of human organs have been rapidly developed. Human lung organoids are currently being applied in various studies such as disease modeling, drug efficacy testing, and regenerative medicine. In the field of environmental toxicology, human lung organoids offer a promising solution for more accurately assessing the health impacts of exposure to PM2.5 and to the limitations posed by 2D cultures and animal models. In this review, we summarize the effects of PM2.5 exposure on human lung and other organoids, as well as the molecular and genetic impacts of such exposure using human organoids. Furthermore, the development of lung-on-a-chip technology to mimic the microenvironment and its utilization for evaluating the pulmotoxicity of PM2.5 exposure are discussed.
3.Comparison of Thyroid-Stimulating Hormone Results from Eight Different Reagents and Assay-Specific Korean Reference Interval for Subclinical Hypothyroidism Treatment
Won Sang YOO ; Sollip KIM ; Young Joo PARK ; Sang Hoon SONG ; Kyunghoon LEE ; Eun Kyung LEE ; Jehoon LEE ; Ho-Young LEE ; Yun Jae CHUNG ; Hyun Kyung CHUNG ; Jin Chul PAENG ; Minje HAN ; Ho-Cheol KANG
International Journal of Thyroidology 2023;16(2):166-174
Background and Objectives:
Recent guidelines from the Korean Thyroid Association have proposed a threshold of 6.8 mIU/L for diagnosing subclinical hypothyroidism based on local research findings. However, due to the lack of standardization/harmonization, thyroid-stimulating hormone (TSH) testing yields varying results across different reagent manufacturers. Hence, the use of uniform reference intervals is challenging. We aimed to establish assay-specific Korean reference interval for TSH.
Materials and Methods:
We performed duplicate measurements on 100 serum samples with varying TSH concentrations (0-23 mIU/L) using eight different TSH reagents including Alinity I TSH (Abbott), Access TSH (Beckman Coulter), Elecsys TSH (Roche), TSH3UL (Siemens),TSH IRMA (Beckman Coulter), TSH1 RIA (Brahms), TSH IRMA TUBE II (Riakey), Turbo TSH IRMA (Izotop).Correlation and simple linear regression analyses were conducted among 8 reagents with Roche as the reference.
Results
The correlation coefficient for each reagent was notably high at 0.99. Through regression analysis, TSH values equivalent to the 6.8 mIU/L (Roche) were determined for each reagent as follows: Abbott 5.2 mIU/L, Beckman 6.5 mIU/L, Siemens 6.9 mIU/L, Beckman-Radioimmunoassay 7.4 mIU/L, Brahms 5.7 mIU/L, Riakey 5.3 mIU/L, Izotop 6.0 mIU/L. Conclusion: Given the observed differences in TSH values associated with different reagents, it is imperative to consider these differences when interpreting results within various clinical contexts and adapting them to clinical practice.
4.Novel Resectable Myocardial Model Using Hybrid Three-Dimensional Printing and Silicone Molding for Mock Myectomy for Apical Hypertrophic Cardiomyopathy
Wooil KIM ; Minje LIM ; You Joung JANG ; Hyun Jung KOO ; Joon-Won KANG ; Sung-Ho JUNG ; Dong Hyun YANG
Korean Journal of Radiology 2021;22(7):1054-1065
Objective:
We implemented a novel resectable myocardial model for mock myectomy using a hybrid method of threedimensional (3D) printing and silicone molding for patients with apical hypertrophic cardiomyopathy (ApHCM).
Materials and Methods:
From January 2019 through May 2020, 3D models from three patients with ApHCM were generated using the end-diastolic cardiac CT phase image. After computer-aided designing of measures to prevent structural deformation during silicone injection into molding, 3D printing was performed to reproduce anatomic details and molds for the left ventricular (LV) myocardial mass. We compared the myocardial thickness of each cardiac segment and the LV myocardial mass and cavity volumes between the myocardial model images and cardiac CT images. The surgeon performed mock surgery, and we compared the volume and weight of the resected silicone and myocardium.
Results:
During the mock surgery, the surgeon could determine an ideal site for the incision and the optimal extent of myocardial resection. The mean differences in the measured myocardial thickness of the model (0.3, 1.0, 6.9, and 7.3 mm in the basal, midventricular, apical segments, and apex, respectively) and volume of the LV myocardial mass and chamber (36.9 mL and 14.8 mL, 2.9 mL and -9.4 mL, and 6.0 mL and -3.0 mL in basal, mid-ventricular and apical segments, respectively) were consistent with cardiac CT. The volume and weight of the resected silicone were similar to those of the resected myocardium (6 mL [6.2 g] of silicone and 5 mL [5.3 g] of the myocardium in patient 2; 12 mL [12.5 g] of silicone and 11.2 mL [11.8 g] of the myocardium in patient 3).
Conclusion
Our 3D model created using hybrid 3D printing and silicone molding may be useful for determining the extent of surgery and planning surgery guided by a rehearsal platform for ApHCM.
5.Novel Resectable Myocardial Model Using Hybrid Three-Dimensional Printing and Silicone Molding for Mock Myectomy for Apical Hypertrophic Cardiomyopathy
Wooil KIM ; Minje LIM ; You Joung JANG ; Hyun Jung KOO ; Joon-Won KANG ; Sung-Ho JUNG ; Dong Hyun YANG
Korean Journal of Radiology 2021;22(7):1054-1065
Objective:
We implemented a novel resectable myocardial model for mock myectomy using a hybrid method of threedimensional (3D) printing and silicone molding for patients with apical hypertrophic cardiomyopathy (ApHCM).
Materials and Methods:
From January 2019 through May 2020, 3D models from three patients with ApHCM were generated using the end-diastolic cardiac CT phase image. After computer-aided designing of measures to prevent structural deformation during silicone injection into molding, 3D printing was performed to reproduce anatomic details and molds for the left ventricular (LV) myocardial mass. We compared the myocardial thickness of each cardiac segment and the LV myocardial mass and cavity volumes between the myocardial model images and cardiac CT images. The surgeon performed mock surgery, and we compared the volume and weight of the resected silicone and myocardium.
Results:
During the mock surgery, the surgeon could determine an ideal site for the incision and the optimal extent of myocardial resection. The mean differences in the measured myocardial thickness of the model (0.3, 1.0, 6.9, and 7.3 mm in the basal, midventricular, apical segments, and apex, respectively) and volume of the LV myocardial mass and chamber (36.9 mL and 14.8 mL, 2.9 mL and -9.4 mL, and 6.0 mL and -3.0 mL in basal, mid-ventricular and apical segments, respectively) were consistent with cardiac CT. The volume and weight of the resected silicone were similar to those of the resected myocardium (6 mL [6.2 g] of silicone and 5 mL [5.3 g] of the myocardium in patient 2; 12 mL [12.5 g] of silicone and 11.2 mL [11.8 g] of the myocardium in patient 3).
Conclusion
Our 3D model created using hybrid 3D printing and silicone molding may be useful for determining the extent of surgery and planning surgery guided by a rehearsal platform for ApHCM.
6.Molecular Analysis of Eight American Type Culture Collection Gonococcal Strains by Neisseria gonorrhoeae Multiantigen Sequence Typing and PorB Sequence Typing
Yousun CHUNG ; Minje HAN ; Ji Young PARK ; Sora KANG ; Inhee KIM ; Jung A PARK ; Jae Seok KIM
Journal of Laboratory Medicine and Quality Assurance 2019;41(1):24-28
BACKGROUND: Molecular epidemiological typing of Neisseria gonorrhoeae is crucial for monitoring the spread of resistant strains. As reference strains can be used for laboratory internal quality control, we genetically characterised the American Type Culture Collection (ATCC) gonococcal strains by Neisseria gonorrhoeae multiantigen sequence typing (NG-MAST) and porB sequence typing using public multilocus sequence typing (PubMLST). METHODS: Eight ATCC gonococcal reference strains (ATCC 19424, ATCC 31426, ATCC 35541, ATCC 43069, ATCC 43070, ATCC 49226, ATCC 49926, and ATCC 49981) from Culti-Loops (Thermo Fisher Scientific, USA) were cultured. After DNA extraction, porB and tbpB were amplified and sequenced. Sequence types (STs) and allele numbers were each determined by NG-MAST (http://www.ng-mast.net) and porB sequence typing using PubMLST (http://pubmlst.org/neisseria/porB/). RESULTS: ATCC 19424 was identified as ST 266 by NG-MAST, and as Allele 946 by PubMLST. ATCC31426 was assigned a novel ST by NG-MAST, and was assigned Allele 958 with 1.2% mismatch by PubMLST. ATCC 35541 was identified as ST 12 by NG-MAST, and as Allele 624 by PubMLST. ATCC 43069 and ATCC 43070 were both identified as ST 681 by NG-MAST, and as Allele 984 by PubMLST. ATCC 49226 was identified as ST 1572 by NG-MAST, and as Allele 2110 by PubMLST. ATCC 49926 and ATCC 49981 were both identified as ST 16496 by NG-MAST, and as Allele 928 by PubMLST. CONCLUSIONS: The ST data obtained for ATCC gonococcal reference strains by NG-MAST and porB sequence typing using PubMLST can be used for quality assurance of molecular epidemiological typing in clinical microbiological laboratories.
Alleles
;
DNA
;
Multilocus Sequence Typing
;
Neisseria gonorrhoeae
;
Neisseria
;
Quality Control
7.Crohn's disease and smoldering multiple myeloma: a case report and literature review.
So Young PARK ; Jae Min KIM ; Hyun Joon KANG ; Minje KIM ; Jae Joon HAN ; Chi Hoon MAENG ; Sun Kyung BAEK ; Hwi Joong YOON ; Si Young KIM ; Hyo Jong KIM
Intestinal Research 2017;15(2):249-254
Crohn's disease (CD) is a chronic inflammatory bowel disease (IBD) that presents with abdominal pain, weight loss, and diarrhea. Although the etiology has not been fully elucidated, both environmental and genetic causes are known to be involved. In chronic inflammatory conditions such as IBD, B lymphocytes are chronically stimulated, and they induce monoclonal expansion of plasma cells, sometimes resulting in monoclonal gammopathy of undetermined significance. Immunomodulators that are commonly used to control inflammation, such as tumor necrosis factor-α (TNF-α) blockers could increase the possibility of hematologic malignancy. The pathogenesis of multiple myeloma in association with TNF-α inhibitor therapy is attributed to decreased apoptosis of plasma cell populations. Here, we describe a case of a 36-year-old male patient who was diagnosed with immunoglobulin A subtype smoldering multiple myeloma during the treatment for CD with infliximab and adalimumab. We report this case along with a review of the literature on cases of multiple myeloma that occurred in conjunction with CD.
Abdominal Pain
;
Adalimumab
;
Adult
;
Apoptosis
;
B-Lymphocytes
;
Crohn Disease*
;
Diarrhea
;
Hematologic Neoplasms
;
Humans
;
Immunoglobulin A
;
Immunologic Factors
;
Inflammation
;
Inflammatory Bowel Diseases
;
Infliximab
;
Male
;
Monoclonal Gammopathy of Undetermined Significance
;
Multiple Myeloma*
;
Necrosis
;
Plasma Cells
;
Tumor Necrosis Factor-alpha
;
Weight Loss
8.Quantification of Human Plasma-Busulfan Concentration by Liquid Chromatography-Tandem Mass Spectrometry.
Soo Young MOON ; Min Kyoo LIM ; Susie HONG ; Yongbum JEON ; Minje HAN ; Sang Hoon SONG ; Kyoung Soo LIM ; Kyung Sang YU ; In Jin JANG ; Ji Won LEE ; Hyoung Jin KANG ; Junghan SONG
Annals of Laboratory Medicine 2014;34(1):7-14
BACKGROUND: Busulfan, an alkylating agent administered prior to hematopoietic stem cell transplantation, has a narrow therapeutic range and wide variability in metabolism. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for rapid and accurate quantification of plasma busulfan. METHODS: Busulfan was separated and detected using an LC system containing a C18 column equipped with MS/MS. The sample was eluted with a mobile phase gradient for a total run time of 10 min. Plasma busulfan concentration was quantified against a 6-point standard curve in a multiple reaction monitoring mode at mass-to-charge (m/z) 264.1 > 151.1. Precision, recovery, matrix effect, linearity, detection capability, carryover, and stability were evaluated. The range of plasma busulfan concentration was obtained by analyzing samples from 9 children receiving busulfan. RESULTS: The coefficients of variation of within-run and within-laboratory precision were all below 5%. Recoveries were all within the range of 100-105%. Linearity was verified from 0 to 5,000 ng/mL. Limit of detection and limit of quantification were 1.56 and 25 ng/mL, respectively. Carryover rate was within allowable limits. Plasma busulfan concentration was stable for 2 weeks at -20degrees C and -80degrees C, but decreased by 25% when the plasma was stored for 24 hr at room temperature, and by <5% in 24 hr at 4degrees C. The plasma busulfan concentrations were between 347 ng/mL and 5,076 ng/mL. CONCLUSIONS: Our method using LC-MS/MS enables highly accurate, reproducible, and rapid busulfan monitoring with minimal sample preparation. The method may also enable safe and proper dosage.
Busulfan/*blood/standards
;
Child
;
Child, Preschool
;
*Chromatography, High Pressure Liquid/standards
;
Hematopoietic Stem Cell Transplantation
;
Humans
;
Infant
;
Quality Control
;
Reference Standards
;
*Tandem Mass Spectrometry/standards

Result Analysis
Print
Save
E-mail