1.Evaluation of Surface Hardness and Wear Resistance of a Glass-Hybrid Restorative Material with Nano-filled Resin Coating
Gawon LEE ; Haeni KIM ; Minho HONG ; Juhyun LEE
Journal of Korean Academy of Pediatric Dentistry 2025;52(2):152-158
This study aimed to evaluate the surface hardness and wear resistance of a novel glass-hybrid restorative material in comparison with those of high-viscosity glass ionomer cement (GIC). Additionally, this study examined how the application of a nano-filled resin coating affected these mechanical properties. This study utilized 80 disk-shaped samples prepared from two distinct GI materials: Equia Forte HT Fil and Fuji IX GP. Half of the specimens from each material group were treated with an Equia Forte Coat. Vickers hardness tests were conducted on a set of 40 specimens, and wear resistance was measured on a separate set of 40 specimens. Equia Forte HT Fil showed significantly higher hardness than Fuji IX GP (p < 0.05). The nano-filled resin coating did not significantly affect the hardness in both groups (p > 0.05). In wear depth measurements, uncoated Equia Forte HT Fil showed significantly lower wear depth compared to uncoated Fuji IX GP (p < 0.05). After coating application, both GI groups showed significantly decreased wear depth (p < 0.05). In terms of both hardness and wear resistance, the properties of the glass-hybrid restorative material were superior to those of the high-viscosity GIC. Nano-filled resin coating exhibited no significant positive effect on the hardness of either GI cement material but significantly increased their wear resistance.
2.Evaluation of Surface Hardness and Wear Resistance of a Glass-Hybrid Restorative Material with Nano-filled Resin Coating
Gawon LEE ; Haeni KIM ; Minho HONG ; Juhyun LEE
Journal of Korean Academy of Pediatric Dentistry 2025;52(2):152-158
This study aimed to evaluate the surface hardness and wear resistance of a novel glass-hybrid restorative material in comparison with those of high-viscosity glass ionomer cement (GIC). Additionally, this study examined how the application of a nano-filled resin coating affected these mechanical properties. This study utilized 80 disk-shaped samples prepared from two distinct GI materials: Equia Forte HT Fil and Fuji IX GP. Half of the specimens from each material group were treated with an Equia Forte Coat. Vickers hardness tests were conducted on a set of 40 specimens, and wear resistance was measured on a separate set of 40 specimens. Equia Forte HT Fil showed significantly higher hardness than Fuji IX GP (p < 0.05). The nano-filled resin coating did not significantly affect the hardness in both groups (p > 0.05). In wear depth measurements, uncoated Equia Forte HT Fil showed significantly lower wear depth compared to uncoated Fuji IX GP (p < 0.05). After coating application, both GI groups showed significantly decreased wear depth (p < 0.05). In terms of both hardness and wear resistance, the properties of the glass-hybrid restorative material were superior to those of the high-viscosity GIC. Nano-filled resin coating exhibited no significant positive effect on the hardness of either GI cement material but significantly increased their wear resistance.
3.Evaluation of Surface Hardness and Wear Resistance of a Glass-Hybrid Restorative Material with Nano-filled Resin Coating
Gawon LEE ; Haeni KIM ; Minho HONG ; Juhyun LEE
Journal of Korean Academy of Pediatric Dentistry 2025;52(2):152-158
This study aimed to evaluate the surface hardness and wear resistance of a novel glass-hybrid restorative material in comparison with those of high-viscosity glass ionomer cement (GIC). Additionally, this study examined how the application of a nano-filled resin coating affected these mechanical properties. This study utilized 80 disk-shaped samples prepared from two distinct GI materials: Equia Forte HT Fil and Fuji IX GP. Half of the specimens from each material group were treated with an Equia Forte Coat. Vickers hardness tests were conducted on a set of 40 specimens, and wear resistance was measured on a separate set of 40 specimens. Equia Forte HT Fil showed significantly higher hardness than Fuji IX GP (p < 0.05). The nano-filled resin coating did not significantly affect the hardness in both groups (p > 0.05). In wear depth measurements, uncoated Equia Forte HT Fil showed significantly lower wear depth compared to uncoated Fuji IX GP (p < 0.05). After coating application, both GI groups showed significantly decreased wear depth (p < 0.05). In terms of both hardness and wear resistance, the properties of the glass-hybrid restorative material were superior to those of the high-viscosity GIC. Nano-filled resin coating exhibited no significant positive effect on the hardness of either GI cement material but significantly increased their wear resistance.
4.Color Stability and Surface Roughness of Single-Shade Composite Resin after Finishing and Polishing
Hyewon SHIN ; Haeni KIM ; Minho HONG ; Juhyun LEE
Journal of Korean Academy of Pediatric Dentistry 2024;51(3):197-207
This study aims to evaluate the color stability and surface roughness of the single-shade composite resin after finishing and polishing for primary molars. A single-shade composite resin (OM, OMNICHROMA) and two multi-shade composite resins (FT, FiltekTM Z350XT; ES, ESTELITE® SIGMA QUICK) were included. The specimens were divided into three subgroups using different polishing methods: control, Sof-Lex XT, and Sof-Lex Diamond. For color stability tests, cavities were prepared on extracted primary second molars and restored with experimental composite resins. Each specimen was immersed in the coffee solution for 48 hours. The color difference of each specimen was calculated. For surface roughness tests, cylindrical specimens were crafted with experimental composite resins. Surface roughness was analyzed using an atomic force microscope and a scanning electron microscope. In the color stability tests, FT demonstrated a significantly lower ΔEab than ES among the control groups, but no significant differences were observed between the ΔEab values of OM and FT or OM and ES. Additionally, no significant differences were found between the Sof-Lex XT and Sof-Lex Diamond subgroups in the three composite groups. Moreover, no significant differences in the surface roughness were found between the three composite groups, regardless of the polishing methods. The single-shade composite resin demonstrated comparable color stability and surface roughness to that of the multi-shade composite resins regardless of the polishing methods used in restoring primary molars. The single-shade composite resin is expected to be applicable in clinical pediatric dentistry reducing chair time due to the easy shade matching procedures.
5.Color Stability and Surface Roughness of Single-Shade Composite Resin after Finishing and Polishing
Hyewon SHIN ; Haeni KIM ; Minho HONG ; Juhyun LEE
Journal of Korean Academy of Pediatric Dentistry 2024;51(3):197-207
This study aims to evaluate the color stability and surface roughness of the single-shade composite resin after finishing and polishing for primary molars. A single-shade composite resin (OM, OMNICHROMA) and two multi-shade composite resins (FT, FiltekTM Z350XT; ES, ESTELITE® SIGMA QUICK) were included. The specimens were divided into three subgroups using different polishing methods: control, Sof-Lex XT, and Sof-Lex Diamond. For color stability tests, cavities were prepared on extracted primary second molars and restored with experimental composite resins. Each specimen was immersed in the coffee solution for 48 hours. The color difference of each specimen was calculated. For surface roughness tests, cylindrical specimens were crafted with experimental composite resins. Surface roughness was analyzed using an atomic force microscope and a scanning electron microscope. In the color stability tests, FT demonstrated a significantly lower ΔEab than ES among the control groups, but no significant differences were observed between the ΔEab values of OM and FT or OM and ES. Additionally, no significant differences were found between the Sof-Lex XT and Sof-Lex Diamond subgroups in the three composite groups. Moreover, no significant differences in the surface roughness were found between the three composite groups, regardless of the polishing methods. The single-shade composite resin demonstrated comparable color stability and surface roughness to that of the multi-shade composite resins regardless of the polishing methods used in restoring primary molars. The single-shade composite resin is expected to be applicable in clinical pediatric dentistry reducing chair time due to the easy shade matching procedures.
6.Color Stability and Surface Roughness of Single-Shade Composite Resin after Finishing and Polishing
Hyewon SHIN ; Haeni KIM ; Minho HONG ; Juhyun LEE
Journal of Korean Academy of Pediatric Dentistry 2024;51(3):197-207
This study aims to evaluate the color stability and surface roughness of the single-shade composite resin after finishing and polishing for primary molars. A single-shade composite resin (OM, OMNICHROMA) and two multi-shade composite resins (FT, FiltekTM Z350XT; ES, ESTELITE® SIGMA QUICK) were included. The specimens were divided into three subgroups using different polishing methods: control, Sof-Lex XT, and Sof-Lex Diamond. For color stability tests, cavities were prepared on extracted primary second molars and restored with experimental composite resins. Each specimen was immersed in the coffee solution for 48 hours. The color difference of each specimen was calculated. For surface roughness tests, cylindrical specimens were crafted with experimental composite resins. Surface roughness was analyzed using an atomic force microscope and a scanning electron microscope. In the color stability tests, FT demonstrated a significantly lower ΔEab than ES among the control groups, but no significant differences were observed between the ΔEab values of OM and FT or OM and ES. Additionally, no significant differences were found between the Sof-Lex XT and Sof-Lex Diamond subgroups in the three composite groups. Moreover, no significant differences in the surface roughness were found between the three composite groups, regardless of the polishing methods. The single-shade composite resin demonstrated comparable color stability and surface roughness to that of the multi-shade composite resins regardless of the polishing methods used in restoring primary molars. The single-shade composite resin is expected to be applicable in clinical pediatric dentistry reducing chair time due to the easy shade matching procedures.
7.Safe Utilization and Sharing of Genomic Data: Amendment to the Health and Medical Data Utilization Guidelines of South Korea
Hyojeong PARK ; Jongkeun PARK ; Hyun Goo WOO ; Hongseok YUN ; Minho LEE ; Dongwan HONG
Cancer Research and Treatment 2024;56(4):1027-1039
Purpose:
In 2024, medical researchers in the Republic of Korea were invited to amend the health and medical data utilization guidelines (Government Publications Registration Number: 11-1352000-0052828-14). This study aimed to show the overall impact of the guideline revision, with a focus on clinical genomic data.
Materials and Methods:
This study amended the pseudonymization of genomic data defined in the previous version through a joint study led by the Ministry of Health and Welfare, the Korea Health Information Service, and the Korea Genome Organization. To develop the previous version, we held three conferences with four main medical research institutes and seven academic societies. We conducted two surveys targeting special genome experts in academia, industry, and institutes.
Results:
We found that cases of pseudonymization in the application of genome data were rare and that there was ambiguity in the terminology used in the previous version of the guidelines. Most experts (>~90%) agreed that the ‘reserved’ condition should be eliminated to make genomic data available after pseudonymization. In this study, the scope of genomic data was defined as clinical next-generation sequencing data, including FASTQ, BAM/SAM, VCF, and medical records. Pseudonymization targets genomic sequences and metadata, embedding specific elements, such as germline mutations, short tandem repeats, single-nucleotide polymorphisms, and identifiable data (for example, ID or environmental values). Expression data generated from multi-omics can be used without pseudonymization.
Conclusion
This amendment will not only enhance the safe use of healthcare data but also promote advancements in disease prevention, diagnosis, and treatment.
8.The Role of Growth Differentiation Factor 15 in Energy Metabolism
Joon Young CHANG ; Hyun Jung HONG ; Seul Gi KANG ; Jung Tae KIM ; Ben Yuan ZHANG ; Minho SHONG
Diabetes & Metabolism Journal 2020;44(3):363-371
Growth differentiation factor 15 (GDF15) is receiving great interest beyond its role as an aging and disease-related biomarker. Recent discovery of its receptor, glial cell line-derived neurotrophic factor (GDNF) family receptor α-like (GFRAL), suggests a central role in appetite regulation. However, there is also considerable evidence that GDF15 may have peripheral activity through an as-of-yet undiscovered mode of action. This raises the question as to whether increased GDF15 induction during pathophysiologic conditions also suppresses appetite. The present review will briefly introduce the discovery of GDF15 and describe the different contexts under which GDF15 is induced, focusing on its induction during mitochondrial dysfunction. We will further discuss the metabolic role of GDF15 under various pathophysiological conditions and conclude with possible therapeutic applications.
9.Delayed postpartum hemoperitoneum due to uterine artery pseudoaneurysm rupture.
Kyu Sang KYEONG ; Ji Yeon MOON ; Song Hwa CHAE ; Seung Hwa HONG ; Minho KANG ; Eun Hwan JEONG
Obstetrics & Gynecology Science 2017;60(3):303-307
A 30-year-old woman experienced severe abdominal pain 8 days after vaginal delivery. The patient was diagnosed with hemoperitoneum due to rupture of the left uterine artery pseudoaneurysm, which was confirmed via ultrasound with color Doppler and computed tomography scans. This patient was treated with bilateral uterine artery embolization to maintain fertility. A uterine artery pseudoaneurysm that causes delayed postpartum hemorrhage can occur after cesarean section or vaginal delivery. A uterine artery pseudoaneurysm can be fatal, so its detection and diagnosis are critical. Herein, we report a case of delayed postpartum hemoperitoneum due to uterine artery pseudoaneurysm rupture.
Abdominal Pain
;
Adult
;
Aneurysm, False*
;
Cesarean Section
;
Diagnosis
;
Female
;
Fertility
;
Hemoperitoneum*
;
Humans
;
Postpartum Hemorrhage
;
Postpartum Period*
;
Pregnancy
;
Rupture*
;
Ultrasonography
;
Uterine Artery Embolization
;
Uterine Artery*
10.Volumetric Changes in the Bony External Auditory Canal in Unilateral Chronic Otitis Media.
Jae Hong PARK ; MinHo NOH ; Chi Kyou LEE ; Seung Bum PARK ; Kye Hoon PARK ; Jong Kyu HAN ; Hyun Jeong KIM
Journal of Audiology & Otology 2016;20(1):41-46
BACKGROUND AND OBJECTIVES: Pneumatization of air cells in the mastoid bone is decreased in chronic otitis media (COM). A decrease in the size of the external auditory canal (EAC) is also found frequently in patients with COM, but this has been little studied. We compared the size of affected bony EACs and the contralateral side in patients with single-side COM using high-resolution computed tomography. SUBJECTS AND METHODS: In total, 99 patients with single-side COM were included. Four indicators related to the size of the bony EAC and IAC were measured using high-resolution computed tomography: the axial and coronal lengths of the tympanic membrane, the length of the isthmus, and the area of the bony ear canal. We also compared both internal auditory canals as negative controls. These assessments were made by radiologists who were blinded to the objective of this study. RESULTS: In patients with single-side COM, the axial length of the tympanic membrane was significantly shorter than normal, and the volume of the EAC was also significantly smaller. The length of the isthmus of the EAC was shorter on the affected side, but the difference was not significant. The IAC volume showed no difference between the two sides. CONCLUSIONS: COM affects general temporal bony development, including the bony EAC and mastoid bone. Therefore, whether to correct this should be considered when preparing for COM surgery.
Ear Canal*
;
Humans
;
Mastoid
;
Otitis Media*
;
Otitis*
;
Tympanic Membrane

Result Analysis
Print
Save
E-mail