1.Comparison of bladder volume measurement accuracy between two-dimensional ultrasound with three-dimensional reconstruction and conventional two-dimensional ultrasound
Kaixuan ZHANG ; Ying CAO ; Lijing ZUO ; Zhen WANG ; Wensheng NIE ; Yongli SONG ; Xing LIU ; Mingjian SUN ; Yuan TANG ; Yueping LIU
Chinese Journal of Radiation Oncology 2025;34(12):1238-1244
Objective:To compare the accuracy of two-dimensional (2D) ultrasound with three-dimensional (3D) reconstruction and conventional 2D ultrasound in measuring bladder volume in pelvic tumor patients, using computed tomography (CT) as the reference.Methods:A set of bladder phantoms were constructed to compare CT and ultrasound measurements with actual injected volumes. Clinical data of 104 pelvic tumor patients who received radiotherapy at the Cancer Hospital, Chinese Academy of Medical Sciences between August and December 2023 were retrospectively analyzed. Portable transabdominal ultrasound was used to obtain the largest bladder cross-section, and the maximum diameters in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions (D LR, D AP, D SI) were measured. The 2D ultrasound volume was calculated as V=0.523 × D LR × D AP × D SI. Full-bladder transverse videos were recorded and processed in Matlab R2016a through frame extraction(60 images), followed by contrast enhancement, edge detection segmentation, cubic spline interpolation, and image smoothing to achieve 3D reconstruction. Paired t-tests, intraclass correlation coefficients (ICC), and Bland-Altman analyses were performed to assess systematic bias and consistency between ultrasound methods and CT. Multivariate linear regression was applied to evaluate the effects of slice thickness, posture, age, and other factors on CT measurements. Results:In the phantom study, deviations of 2D ultrasound and CT from actual injected volumes were (0.73±3.05) ml ( t=-0.48, P=0.667) and (1.52±11.27) ml ( t=0.17, P=0.875), with ICC values>0.999. In the clinical study, mean bladder volumes measured by 3D-reconstructed ultrasound, conventional 2D ultrasound, and CT were (373.5±153.31), (314.89±135.28), (382.82±157.57) ml, respectively. The 3D-reconstructed method showed excellent agreement with CT (ICC=0.98; Bland-Altman mean bias=-9.32 ml, P=0.096), while 2D ultrasound also showed good consistency (ICC=0.91), but significantly underestimated bladder volume (mean bias=-67.93 ml, P<0.001). Subgroup analysis revealed that 2D ultrasound had the best agreement with CT in the medium-volume group (200-500 ml, ICC=0.902), whereas agreement decreased in the small-volume (<200 ml, ICC=0.884) and large-volume (>500 ml, ICC=0.840) groups (all P<0.001). The 3D-reconstructed ultrasound maintained excellent consistency with CT across all subgroups (all ICC>0.95), and the measured bladder volume was not statistically significant. Multivariate regression showed that slice thickness, posture, age, sex, and surgical status had no significant effects on CT measurements. Conclusions:Ultrasound with 3D reconstruction enables accurate bladder volume monitoring through true 3D contour reconstruction, while conventional 2D ultrasound systematically underestimates bladder volume and requires correction.
2.Study on surface microcirculation sensitization of acupuncture points related to cold coagulation and stasis syndrome in primary dysmenorrhea
Xuxin LI ; Xuesong WANG ; Miao LIN ; Mingjian ZHANG ; Yuanbo GAO ; Xifen ZHANG ; Hao CHEN ; Haiping LI ; Xiaojun ZHENG ; Xisheng FAN ; Jun LIU ; Juncha ZHANG ; Yanfen SHE
Journal of Beijing University of Traditional Chinese Medicine 2025;48(2):253-269
Objective:
To assess the dynamic changes of microcirculation at acupoints in patients with primary dysmenorrhea and cold congelation and blood stasis syndrome using laser speckle blood flow imaging.
Methods:
Patients with primary dysmenorrhea and cold coagulation and blood stasis syndrome (primary dysmenorrhea group, n=53) and healthy female college students(control group, n=57) who met the inclusion and exclusion criteria from October 2020 to July 2022 were enrolled at Hebei University of Chinese Medicine. On the premenstrual and first day of menstruation, a laser speckle blood flow imaging system was used to measure the microcirculation blood flow perfusion on the surface of acupoints related to the conception, thoroughfare, and governor vessels, and stomach, spleen, and bladder meridians in the abdomen and lumbosacral regions. The dynamic changes in microcirculation were calculated based on the difference in average blood flow perfusion at each acupoint before and after menstruation. Receiver operating curve (ROC) analysis was used to analyze the diagnostic efficacy of dynamic changes in microcirculation on the surface of each acupoint. The microcirculation sensitization rate of acupoints was calculated.
Results:
Compared with the control group, the dynamic changes in microcirculation at the following acupoints in the primary dysmenorrhea group were increased (P<0.05): conception vessel (Yinjiao[CV7], Qihai[CV6], Shimen[CV5], Guanyuan[CV4]); left thoroughfare vessel (left Huangshu[KI16], left Zhongzhu[KI15], left Siman[KI14], left Qixue[KI13], left Dahe[KI12], left Henggu[KI11]); left stomach meridian (left Tianshu[ST25], left Wailing[ST26], left Qichong[ST30]); left spleen meridian (left Daheng[SP15], left Fujie[SP14]); right thoroughfare vessel (right Huangshu[KI16], right Zhongzhu[KI15], right Siman[KI14], right Qixue[KI13], right Dahe[KI12], right Henggu[KI11]); right stomach meridian (right Wailing[ST26], right Daju[ST27], right Shuidao[ST28], right Guilai[ST29], right Qichong[ST30]); and right spleen meridian (right Fujie[SP14]). The area under the ROC curve of conception vessel (Yinjiao[CV7], Qihai[CV6], Shimen[CV5], Guanyuan[CV4]), thoroughfare vessel (right Siman[KI14], left Huangshu[KI16], right Qixue[KI13], right Zhongzhu[KI15], right Dahe[KI12], left Zhongzhu[KI15], left Siman[KI14], right Huangshu[KI16], left Qixue[KI13], right Henggu[KI11], left Henggu[KI11], left Dahe[KI12]); stomach meridian (left Tianshu[ST25], right Guilai[ST29], left Wailing[ST26], right Shuidao[ST28], right Daju[ST27], right Wailing[ST26], right Qichong[ST30], left Qichong[ST30]), and spleen meridian (left Daheng[SP15], left Fujie[SP14], right Fujie[SP14]) was 0.610-0.682 (P<0.05). Compared with the control group, the sensitization rate of some acupoints in the primary dysmenorrhea group increased (P<0.05).
Conclusion
With the onset of menstruation, the blood flow perfusion of some acupoints in the abdomen (thoroughfare, and conception vessels, and stomach and spleen meridians) of patients with primary dysmenorrhea and cold blood coagulation and blood stasis syndrome increased, and the status of acupoints changed from a resting state to an active state. These acupoints are sensitive in patients with primary dysmenorrhea and cold blood coagulation and blood stasis syndrome and have a certain diagnostic efficacy, providing a basis for further analyzing the efficacy and mechanism of acupuncture and moxibustion to treat primary dysmenorrhea with cold blood coagulation and blood stasis syndrome.
3.Establishment of a"#-shaped"method of radiotherapy marking of reflecting the range of respiratory motion in radiotherapy
Chenlei GUO ; Ying CAO ; Xin FENG ; Kaixuan ZHANG ; Zhen WANG ; Mingjian SUN ; Yongli SONG ; Xing LIU ; Wenyang LIU ; Jianrong DAI
China Medical Equipment 2025;22(8):52-56
Objective:To propose a novel radiotherapy marking method-the"#"-character method,which aimed at improving the accuracy and repeatability of positioning during radiotherapy.Methods:A specially"cross-shaped"stamp was designed by this study,which consisted of a handheld square base with a"cross-shaped"protrusion.Using this stamp,the extreme positions of end-expiration and end-inspiration were marked respectively at the laser-guided regions on the directly above and bilateral sides of the patient's body,and each position was printed a"+"character.Finally,a"#-shaped"signal was formed,which represented the full range of respiratory motion of patients.The study included two parts:surface displacement caused by respiration was simulated through a three-dimensional(3D)motion platform,which was used to conduct a phantom experiment for anthropomorphic dummy,A randomized controlled study involving 40 patients,who were treated between January and June 2024 at the Department of Radiotherapy,Cancer Hospital,Chinese Academy of Medical Sciences,were conducted.The cohort included 20 patients with breast tumor(Positioning the outer contour by exposing the chest)and 20 patients with thoracic tumor(fixed position of using thermoplastic film).These patients were divided into two groups for comparison,which received respectively the"#-shaped"method and the conventional"+-shaped"method.The cone-beam computed tomography(CBCT)images before treatment were used to compare the influences of the two kinds of marking methods on the positioning errors of patients with breast tumor and patients with thoracic tumor.Then,the statistical analysis was used to assess precision and accuracy of positioning.Results:The result of phantom experiment indicated that the positioning error of the"#-shaped"method was significantly better than that of the"+-shaped"method under various parameters of respiratory movement.Under three kinds of different respiratory cycles(3,4,and 5 seconds)and amplitudes(8,12,and 15 mm),the positioning errors of the"#-shaped"method were respectively(0.15±0.04)cm,(0.19±0.05)cm and(0.35±0.14)cm,while the"+-shaped"method were respectively(0.42±0.16)cm,(0.64±0.28)cm and(0.88±0.37)cm,and the differences were statistically significant(t=8.347,3.416,2.901,P<0.05).The results of actual patients indicated the positioning error[(0.97±0.32)cm]of the"#-shaped"method was significantly lower than[(1.62±0.47)cm]of the"+-shaped"method for patients with breast tumor(Positioning the outer contour by exposing the chest),and the difference was significant(t=3.615,P<0.05).On the other hand,the positioning error[(0.69±0.24)cm]of the"#-shaped"method was significantly lower than[(0.97±0.39)cm]of the"+-shaped"method for patients with thoracic tumor(fixed position of using thermoplastic film),and the difference also was significant(t=1.934,P<0.05).Conclusion:Compared to the conventional"+-shaped"method,the"#-shaped"method appears higher accuracy and repeatability during the positioning process of radiotherapy,which especially is suitable to the treatment for breast tumor and thoracic tumor that need accurately control the influences of respiratory motion.
4.Establishment of a"#-shaped"method of radiotherapy marking of reflecting the range of respiratory motion in radiotherapy
Chenlei GUO ; Ying CAO ; Xin FENG ; Kaixuan ZHANG ; Zhen WANG ; Mingjian SUN ; Yongli SONG ; Xing LIU ; Wenyang LIU ; Jianrong DAI
China Medical Equipment 2025;22(8):52-56
Objective:To propose a novel radiotherapy marking method-the"#"-character method,which aimed at improving the accuracy and repeatability of positioning during radiotherapy.Methods:A specially"cross-shaped"stamp was designed by this study,which consisted of a handheld square base with a"cross-shaped"protrusion.Using this stamp,the extreme positions of end-expiration and end-inspiration were marked respectively at the laser-guided regions on the directly above and bilateral sides of the patient's body,and each position was printed a"+"character.Finally,a"#-shaped"signal was formed,which represented the full range of respiratory motion of patients.The study included two parts:surface displacement caused by respiration was simulated through a three-dimensional(3D)motion platform,which was used to conduct a phantom experiment for anthropomorphic dummy,A randomized controlled study involving 40 patients,who were treated between January and June 2024 at the Department of Radiotherapy,Cancer Hospital,Chinese Academy of Medical Sciences,were conducted.The cohort included 20 patients with breast tumor(Positioning the outer contour by exposing the chest)and 20 patients with thoracic tumor(fixed position of using thermoplastic film).These patients were divided into two groups for comparison,which received respectively the"#-shaped"method and the conventional"+-shaped"method.The cone-beam computed tomography(CBCT)images before treatment were used to compare the influences of the two kinds of marking methods on the positioning errors of patients with breast tumor and patients with thoracic tumor.Then,the statistical analysis was used to assess precision and accuracy of positioning.Results:The result of phantom experiment indicated that the positioning error of the"#-shaped"method was significantly better than that of the"+-shaped"method under various parameters of respiratory movement.Under three kinds of different respiratory cycles(3,4,and 5 seconds)and amplitudes(8,12,and 15 mm),the positioning errors of the"#-shaped"method were respectively(0.15±0.04)cm,(0.19±0.05)cm and(0.35±0.14)cm,while the"+-shaped"method were respectively(0.42±0.16)cm,(0.64±0.28)cm and(0.88±0.37)cm,and the differences were statistically significant(t=8.347,3.416,2.901,P<0.05).The results of actual patients indicated the positioning error[(0.97±0.32)cm]of the"#-shaped"method was significantly lower than[(1.62±0.47)cm]of the"+-shaped"method for patients with breast tumor(Positioning the outer contour by exposing the chest),and the difference was significant(t=3.615,P<0.05).On the other hand,the positioning error[(0.69±0.24)cm]of the"#-shaped"method was significantly lower than[(0.97±0.39)cm]of the"+-shaped"method for patients with thoracic tumor(fixed position of using thermoplastic film),and the difference also was significant(t=1.934,P<0.05).Conclusion:Compared to the conventional"+-shaped"method,the"#-shaped"method appears higher accuracy and repeatability during the positioning process of radiotherapy,which especially is suitable to the treatment for breast tumor and thoracic tumor that need accurately control the influences of respiratory motion.
5.Comparison of bladder volume measurement accuracy between two-dimensional ultrasound with three-dimensional reconstruction and conventional two-dimensional ultrasound
Kaixuan ZHANG ; Ying CAO ; Lijing ZUO ; Zhen WANG ; Wensheng NIE ; Yongli SONG ; Xing LIU ; Mingjian SUN ; Yuan TANG ; Yueping LIU
Chinese Journal of Radiation Oncology 2025;34(12):1238-1244
Objective:To compare the accuracy of two-dimensional (2D) ultrasound with three-dimensional (3D) reconstruction and conventional 2D ultrasound in measuring bladder volume in pelvic tumor patients, using computed tomography (CT) as the reference.Methods:A set of bladder phantoms were constructed to compare CT and ultrasound measurements with actual injected volumes. Clinical data of 104 pelvic tumor patients who received radiotherapy at the Cancer Hospital, Chinese Academy of Medical Sciences between August and December 2023 were retrospectively analyzed. Portable transabdominal ultrasound was used to obtain the largest bladder cross-section, and the maximum diameters in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions (D LR, D AP, D SI) were measured. The 2D ultrasound volume was calculated as V=0.523 × D LR × D AP × D SI. Full-bladder transverse videos were recorded and processed in Matlab R2016a through frame extraction(60 images), followed by contrast enhancement, edge detection segmentation, cubic spline interpolation, and image smoothing to achieve 3D reconstruction. Paired t-tests, intraclass correlation coefficients (ICC), and Bland-Altman analyses were performed to assess systematic bias and consistency between ultrasound methods and CT. Multivariate linear regression was applied to evaluate the effects of slice thickness, posture, age, and other factors on CT measurements. Results:In the phantom study, deviations of 2D ultrasound and CT from actual injected volumes were (0.73±3.05) ml ( t=-0.48, P=0.667) and (1.52±11.27) ml ( t=0.17, P=0.875), with ICC values>0.999. In the clinical study, mean bladder volumes measured by 3D-reconstructed ultrasound, conventional 2D ultrasound, and CT were (373.5±153.31), (314.89±135.28), (382.82±157.57) ml, respectively. The 3D-reconstructed method showed excellent agreement with CT (ICC=0.98; Bland-Altman mean bias=-9.32 ml, P=0.096), while 2D ultrasound also showed good consistency (ICC=0.91), but significantly underestimated bladder volume (mean bias=-67.93 ml, P<0.001). Subgroup analysis revealed that 2D ultrasound had the best agreement with CT in the medium-volume group (200-500 ml, ICC=0.902), whereas agreement decreased in the small-volume (<200 ml, ICC=0.884) and large-volume (>500 ml, ICC=0.840) groups (all P<0.001). The 3D-reconstructed ultrasound maintained excellent consistency with CT across all subgroups (all ICC>0.95), and the measured bladder volume was not statistically significant. Multivariate regression showed that slice thickness, posture, age, sex, and surgical status had no significant effects on CT measurements. Conclusions:Ultrasound with 3D reconstruction enables accurate bladder volume monitoring through true 3D contour reconstruction, while conventional 2D ultrasound systematically underestimates bladder volume and requires correction.
6.Variation of right B2 downwards-shift: A special type of tracheal bronchus
Zhili LIU ; Min ZHANG ; Xingyuan LIU ; Mingjian GE
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(12):1759-1766
Objective To analyze and summarize the changes of the bronchus and vessels of right B2 downwards-shift. Methods The 5 280 patients who underwent three-dimensional computed tomography bronchography and angiography between January 2019 and January 2022 were screened. Based on the opening position of B1+3, we classified bronchial variations into a normal type, over type, and tracheal-bronchus type. Results Finally 6 patients were included with 1 male and 5 females, aged 29 to 71 years. According to our bronchial classification, there were 4 (66.7%) patients of the normal type in this group, 1 (16.7%) of over type, and 1 (16.7%) of tracheal-bronchus type. About arteries, 4 (66.7%) patients was the trunk superior (Tr.sup)+posterior artery (A.post) type and 2 (33.3%) Tr.sup+trunk inferior (Tr.inf)+A.post type. About veins, 2 (33.3%) patients were the Ⅰab+right upper lobe vein posterior to the bronchus intermedius (UVPBI) type, 1 (16.7%)Ⅰb+UVPBI type, 1 (16.7%) anterior+UVPBI type, 1 (16.7%) central+UVPBI type and 1 (16.7%) central type. Conclusion In the right B2 downwards-shift, A.post exists, and the posterior oblique fissure is poorly developed (RS2 and RS6 are interconnected). Therefore, it is easier for us to dissect and disconnect B2 intraoperatively, but it is necessary to be vigilant for vascular damage caused by opening the posterior oblique fissure.
7.Predictive effect of the dual-parametric MRI modified maximum diameter of the lesions with PI-RADS 4 and 5 on the clinically significant prostate cancer
Yuxuan TIAN ; Mingjian RUAN ; Yi LIU ; Derun LI ; Jingyun WU ; Qi SHEN ; Yu FAN ; Jie JIN
Journal of Peking University(Health Sciences) 2024;56(4):567-574
Objective:To assess the rationality of the maximum lesion diameter of 15 mm in prostate imaging reporting and data system(PI-RADS)as a criterion for upgrading a lesion from category 4 to 5 and improve it to enhance the prediction of clinically significant prostate cancer(csPCa).Methods:In this study,the patients who underwent prostate magnetic resonance imaging(MRI)and prostate biopsy at Peking University First Hospital from 2019 to 2022 as a development cohort,and the patients in 2023 as a validation cohort were reviewed.The localization and maximum diameter of the lesion were fully evalua-ted.The area under the curve(AUC)and the cut-off value of the maximum diameter of the lesion to pre-dict the detection of csPCa were calculated from the receiver operating characteristics(ROC)curve.Confounding factors were reduced by propensity score matching(PSM).Diagnostic efficacy was com-pared in the validation cohort.Results:Of the 589 patients in the development cohort,358(60.8%)lesions were located in the peripheral zone and 231(39.2%)were located in the transition zone,and 496(84.2%)patients detected csPCa.The median diameter of the lesions in the peripheral zone was smaller than that in the transition zone(14 mm vs.19 mm,P<0.001).In the ROC analysis of the maximal diameter on the csPCa prediction,there was no statistically significant difference between the peri-pheral zone(AUC=0.709)and the transition zone(AUC=0.673,P=0.585),and the cut-off values were calculated to be 11.5 mm for the peripheral zone and 16.5 mm for the migrating zone.By calcula-ting the Youden index for the cut-off values in the validation cohort,we found that the categorisation by lesion location led to better predictive results.Finally,the net reclassification index(NRI)was 0.170.Conclusion:15 mm as a criterion for upgrading the PI-RADS score from 4 to 5 is reasonable but too general.The cut-off value for peripheral zone lesions is smaller than that in transitional zone.In the future consideration could be given to setting separate cut-off values for lesions in different locations.
8.Diagnostic efficacy of targeted biopsy combined with regional systematic biopsy in prostate cancer in patients with PI-RADS 4-5
Kaifeng YAO ; Mingjian RUAN ; Derun LI ; Yuxuan TIAN ; Yuke CHEN ; Yu FAN ; Yi LIU
Journal of Peking University(Health Sciences) 2024;56(4):575-581
Objective:To investigate the diagnostic efficacy of targeted biopsy combined with regional systematic biopsy in prostate cancer(PCa)in patients with prostate imaging reporting and data system v2.1(PI-RADS v2.1)4-5.Methods:From January 2023 to October 2023,patients who underwent prostate biopsy for the first time with total prostate specific antigen(tPSA)≤20 ng/mL and had a multi-parametric magnetic resonance imaging(mpMRI)PI-RADS of 4-5 in Peking University First Hospital were prospectively collected.All the patients underwent transrectal ultrasound-guided cognitive fusion tar-geted biopsy(3 cores)followed by systematic biopsy(12 cores).Various hypothetical biopsy schemes were defined based on different biopsy sites.The detection effectiveness of targeted biopsy combined with regional systematic biopsy and other biopsy schemes for prostate cancer were compared using Cochran's Q and McNemar tests.Results:A total of 255 patients were enrolled,of whom 204(80.0%)were de-tected with prostate adenocarcinoma and 187(73.3%)were clinically significant with prostate cancer(csPCa).The detection rate of PCa with targeted biopsy was significantly lower than that of targeted biopsy combined with 12-core system biopsy(77.3%vs.80.0%,P=0.016),and 71.4%(5/7)of the missed patients was csPCa.There was no significant difference in the detection rate between targeted biopsy combined with 4-core regional system biopsy and 12-core system biopsy(P>0.999),and 1 case of csPCa and clinically insignificant prostate cancer(cisPCa)were missed.There was no significant difference in the detection rate of PCa between targeted combined regional system biopsy and targeted combined lateral or traditional 6-core system biopsy and the number of cores were reduced.Missed diag-nosis of targeted biopsy was correlated with the maximum diameter of the lesion(OR=0.086,95%CI:0.013-0.562,P=0.010).For the patients with PI-RADS 5,only 1 case of PCa was missed in 122 cases by targeted biopsy alone.For patients with PI-RADS 4,6 PCa cases were missed among the 133 patients with targeted biopsy alone,and 1 case of csPCa and cisPCa were missed by targeted biopsy com-bined with regional system biopsy.The statistics of positive core counts for different biopsy schemes indi-cated that targeted combined regional systematic biopsy had a higher proportion of positive cores second only to targeted biopsy alone.Conclusion:Targeted biopsy combined with regional systematic biopsy has high diagnostic efficacy in patients with PI-RADS 4-5 and can be considered as one of the improved schemes for combined biopsy.Targeted biopsy alone is also a feasible option for patients for patients with a PI-RADS score of 5.
9.Interpretation of the surgical treatment of pancreatic cancer of the 2024 edition of the NCCN guidelines
Mingjian MA ; He CHENG ; Yusheng CHEN ; Chen LIU ; Xianjun YU
Chinese Journal of Surgery 2024;62(7):659-664
Pancreatic cancer is a highly malignant tumor in the digestive system, and radical surgery is the only possible means to cure pancreatic cancer at present. In the past decade, pancreatic surgery has been developing rapidly, with various new technologies and concepts emerging, among which the use of minimally invasive techniques and the popularization of neoadjuvant therapy concepts are the most notable. At the same time, the surgical treatment of pancreatic cancer still has a long way to go, and many problems need to be solved urgently. This article introduces the surgical treatment of pancreatic cancer in the 2024 edition of the NCCN guidelines, focusing on minimally invasive and open surgical treatments, expanded lymph node dissection, combined vascular resection and reconstruction, surgical treatment of pancreatic neck cancer and neoadjuvant therapy, and briefly discussing the unresolved issues.
10.Preparation methods,advantages,and disadvantages of cartilage scaffold materials
Zewen WANG ; Chenzhi LI ; Jiahe LIU ; Yancheng LI ; Mingjian WU ; Yan CUI ; Zhenhao LI ; Wanqi XIONG ; Ting HE ; Baoyi LIU ; Fan YANG
Chinese Journal of Tissue Engineering Research 2024;28(15):2404-2409
BACKGROUND:Scaffold materials serve as platforms that provide space and structure,playing a crucial role in the regeneration of cartilage tissue.Scholars from around the world are exploring different approaches to fabricate more ideal scaffold materials. OBJECTIVE:To review the design principles and preparation methods of cartilage scaffolds,and to further explore the advantages and limitations of various preparation methods. METHODS:Literature searches were conducted on the databases of CNKI,WanFang Data,PubMed,and FMRS from 1998 to 2023.The search terms were"cartilage repair,cartilage tissue engineering,cartilage scaffold materials,preparation"in Chinese and English.A total of 57 articles were ultimately reviewed. RESULTS AND CONCLUSION:(1)The articular cartilage has a unique structure and limited self-repair capacity after injury.Even if self-repair occurs,the newly formed cartilage is typically fibrocartilage,which is far inferior to normal articular cartilage in terms of structure and mechanical properties.It is difficult to maintain normal function and often leads to degenerative changes.Currently,the design and fabrication of scaffold materials for cartilage repair need to consider the following aspects:biocompatibility and biodegradability,suitable pore structure and porosity,appropriate mechanical properties,and bioactivity.(2)Research on the preparation of cartilage scaffolds has made significant progress,continuously introducing new preparation methods and optimization strategies.These methods have their advantages and disadvantages,providing more possibilities for customized preparation and functional design of cartilage scaffolds according to specific requirements.


Result Analysis
Print
Save
E-mail