1.Terms Related to The Study of Biomacromolecular Condensates
Ke RUAN ; Xiao-Feng FANG ; Dan LI ; Pi-Long LI ; Yi LIN ; Zheng WANG ; Yun-Yu SHI ; Ming-Jie ZHANG ; Hong ZHANG ; Cong LIU
Progress in Biochemistry and Biophysics 2025;52(4):1027-1035
Biomolecular condensates are formed through phase separation of biomacromolecules such as proteins and RNAs. These condensates exhibit liquid-like properties that can futher transition into more stable material states. They form complex internal structures via multivalent weak interactions, enabling precise spatiotemporal regulations. However, the use of inconsistent and non-standardized terminology has become increasingly problematic, hindering academic exchange and the dissemination of scientific knowledge. Therefore, it is necessary to discuss the terminology related to biomolecular condensates in order to clarify concepts, promote interdisciplinary cooperation, enhance research efficiency, and support the healthy development of this field.
2.Safety of high-carbohydrate fluid diet 2 h versus overnight fasting before non-emergency endoscopic retrograde cholangiopancreatography: A single-blind, multicenter, randomized controlled trial
Wenbo MENG ; W. Joseph LEUNG ; Zhenyu WANG ; Qiyong LI ; Leida ZHANG ; Kai ZHANG ; Xuefeng WANG ; Meng WANG ; Qi WANG ; Yingmei SHAO ; Jijun ZHANG ; Ping YUE ; Lei ZHANG ; Kexiang ZHU ; Xiaoliang ZHU ; Hui ZHANG ; Senlin HOU ; Kailin CAI ; Hao SUN ; Ping XUE ; Wei LIU ; Haiping WANG ; Li ZHANG ; Songming DING ; Zhiqing YANG ; Ming ZHANG ; Hao WENG ; Qingyuan WU ; Bendong CHEN ; Tiemin JIANG ; Yingkai WANG ; Lichao ZHANG ; Ke WU ; Xue YANG ; Zilong WEN ; Chun LIU ; Long MIAO ; Zhengfeng WANG ; Jiajia LI ; Xiaowen YAN ; Fangzhao WANG ; Lingen ZHANG ; Mingzhen BAI ; Ningning MI ; Xianzhuo ZHANG ; Wence ZHOU ; Jinqiu YUAN ; Azumi SUZUKI ; Kiyohito TANAKA ; Jiankang LIU ; Ula NUR ; Elisabete WEIDERPASS ; Xun LI
Chinese Medical Journal 2024;137(12):1437-1446
Background::Although overnight fasting is recommended prior to endoscopic retrograde cholangiopancreatography (ERCP), the benefits and safety of high-carbohydrate fluid diet (CFD) intake 2 h before ERCP remain unclear. This study aimed to analyze whether high-CFD intake 2 h before ERCP can be safe and accelerate patients’ recovery.Methods::This prospective, multicenter, randomized controlled trial involved 15 tertiary ERCP centers. A total of 1330 patients were randomized into CFD group ( n = 665) and fasting group ( n = 665). The CFD group received 400 mL of maltodextrin orally 2 h before ERCP, while the control group abstained from food/water overnight (>6 h) before ERCP. All ERCP procedures were performed using deep sedation with intravenous propofol. The investigators were blinded but not the patients. The primary outcomes included postoperative fatigue and abdominal pain score, and the secondary outcomes included complications and changes in metabolic indicators. The outcomes were analyzed according to a modified intention-to-treat principle. Results::The post-ERCP fatigue scores were significantly lower at 4 h (4.1 ± 2.6 vs. 4.8 ± 2.8, t = 4.23, P <0.001) and 20 h (2.4 ± 2.1 vs. 3.4 ± 2.4, t= 7.94, P <0.001) in the CFD group, with least-squares mean differences of 0.48 (95% confidence interval [CI]: 0.26–0.71, P <0.001) and 0.76 (95% CI: 0.57–0.95, P <0.001), respectively. The 4-h pain scores (2.1 ± 1.7 vs. 2.2 ± 1.7, t = 2.60, P = 0.009, with a least-squares mean difference of 0.21 [95% CI: 0.05–0.37]) and positive urine ketone levels (7.7% [39/509] vs. 15.4% [82/533], χ2 = 15.13, P <0.001) were lower in the CFD group. The CFD group had significantly less cholangitis (2.1% [13/634] vs. 4.0% [26/658], χ2 = 3.99, P = 0.046) but not pancreatitis (5.5% [35/634] vs. 6.5% [43/658], χ2 = 0.59, P = 0.444). Subgroup analysis revealed that CFD reduced the incidence of complications in patients with native papilla (odds ratio [OR]: 0.61, 95% CI: 0.39–0.95, P = 0.028) in the multivariable models. Conclusion::Ingesting 400 mL of CFD 2 h before ERCP is safe, with a reduction in post-ERCP fatigue, abdominal pain, and cholangitis during recovery.Trail Registration::ClinicalTrials.gov, No. NCT03075280.
3.Ultra-fast track anesthesia management for transcatheter mitral valve edge-to-edge repair
Zhi-Yao ZOU ; Da ZHU ; Yi-Ming CHEN ; Shou-Zheng WANG ; Jian-Bin GAO ; Jing DONG ; Xiang-Bin PAN ; Ke YANG
Chinese Journal of Interventional Cardiology 2024;32(5):250-256
Objective To retrospectively analyze the ultra-fast track anesthesia(UFTA)methods and perioperative anesthesia management experiences of transcatheter mitral valve edge-to-edge repair(TEER)in the treatment of functional mitral regurgitant.Methods In this retrospective study,patients underwent the TEER procedure and received UFTA in Fuwai Yunnan Hospital,from May 2022 to September 2022 for heart failure combined with moderate to severe or severe functional mitral regurgitant were included.Baseline,preoperative complications,cardial function and anesthesia classification,amino-terminal probrain natriuretic peptide(NT-proBNP),ultrasound examination results,surgery time,extubation time,intraoperative anesthetic and vasoactive drug,complications related to TEER and UFTA,perioperative,and postoperative 30-day and one-year follow-up data were collected.All perioperative clinical data were recorded and analyzed.Results A total of 30 patients were enrolled,11 patients(36.7%)were female,mean age was(63.6±6.1)years,NYHA classification IV 14 patients(46.7%),left ventricular ejection fraction(LVEF)(36.0±8.1)%,the end-diastolic volume of the left ventricle(66.0±8.2)mm,mitral regurgitation 4+14 patients(56.7%),3+17 patients(43.3%),NT-proBNP(1 934.1±1 973.5)pg/ml,1 patient(3.3%)used high-dose vasoactive drugs during surgery.All patients did not experience nausea,vomiting,delirium,respiratory depression,perioperative transesophageal echocardiography-related gastrointestinal bleeding,pericardial effusion,cerebrovascular accidents,emergency surgery or secondary intervention,or other serious adverse events within 24 hours after surgery.No 30-day all-cause death occurred;the mean postoperative hospital stay was(7.4±2.8)days.All patients completed one-year follow-up,LVEF(37.6±11.1)%,the end-diastolic volume of the left ventricle(63.2±8.6)mm,mitral regurgitation 2+7 patients(23.3%),1+23 patients(76.7%),NT-proBNP(1 949.2±2 576.6)pg/ml.Conclusions Ultra-fast track anesthesia can be safely applied to TEER in treating functional mitral regurgitant patients.
4.Transcatheter edge-to-edge mitral valve repair for the treatment of mitral valve prolapse with cleft:a case report
Yun-Long MA ; Ming-Jun HE ; Xiang HAO ; Shun WANG ; Xiao-Zhen ZHUO ; Zu-Yi YUAN ; Ke HAN
Chinese Journal of Interventional Cardiology 2024;32(5):284-287
Mitral valve prolapse is one of the common causes of mitral regurgitation.Mitral valve prolapse complicated with leaflet cleft is rare in clinical practice,which most often undergo surgical mitral valve repair or mitral valve replacement.We report a case of mitral valve prolapse with posterior leaflet cleft treated by transcatheter edge-to-edge mitral valve repair,in order to provide a model for similar cases.
5.Detection of five tick-borne pathogens in Maanshan City,Anhui Province,China
Guo-Dong YANG ; Kun YANG ; Liang-Liang JIANG ; Ming WU ; Ying HONG ; Ke-Xia XIANG ; Jia HE ; Lei GONG ; Dan-Dan SONG ; Ming-Jia BAO ; Xing-Zhou LI ; Tian QIN ; Yan-Hua WANG
Chinese Journal of Zoonoses 2024;40(4):308-314
Here,5 important pathogens carried by ticks in Maanshan City,Anhui Province,China were identified.In to-tal,642 ticks were collected from 13 villages around Maanshan City and identified by morphological and mitochondrial COI genes.The 16S rRNA gene of Francisella tularensis,ssrA gene of Bartonella,16S rRNA,ompA and ompB genes of Rickett-sia,16S rRNA and gltA genes of Anaplasma,and groEL and rpoB genes of Coxiella were sequenced.Reference sequences were retrieved from a public database.Phylogenetic trees were constructed with MEG A1 1.0 software.In total,36 Rickettsiae isolates were detected in 640 Haemaphysalis longicornis ticks,which included 20 isolates of Rickettsia heilongjian-gensis,16 of Candidatus Rickettsia jingxinensis,2 of Ana-plasma bovis,and 186 of Coxiella-like endosymbiont.R.hei-longjiangensis HY2 detected in this study and Anhui B8 strain,Ca.R.jingxinensis QL3 and those from Shanxi Prov-ince and Jiangsu Province,A.bovis JX4 and those from Shanxi Province were clustered on the same branch.Overall,17 ticks had combined infections and none of the 5 bacteria were detected in two Amblyomma testudinarium ticks.This is the first report of Ca.R.jingxinensis detected in H.longicornis ticks from Anhui Province.It is recommended that the two types of Rickettsia that cause spotted fever and A.bovis should be reported to local health authorities to initiate appropriate prevention and control measures.
6.Secondary metabolites from endophytic fungi Candida sp.of Berberis atrocarpa
Ming-Zhuo GUO ; Shu-Fang MA ; Shi-Miao WANG ; Ya-Ping FENG ; Yan OUYANG ; Ke-Jian PANG ; Zi-Wei JIAO ; Xin-Zhou YANG
Chinese Traditional Patent Medicine 2024;46(9):3000-3005
AIM To study the secondary metabolites from the endophytic fungi Candida sp.of Berberis atrocarpa Schneid.METHODS The ethyl acetate fraction and petroleum ether fraction from the secondary metabolites of Candida sp.fermentation extract were separated and purified by silica gel,Sephadex LH-20 and preparative liquid chromatography,then the structures of obtained compounds were identified by physicochemical properties and spectral data.RESULTS Eighteen compounds were isolated and identified as 1-phenyl-1,2-ethanediol(1),4-hydroxyphenethyl alcohol(2),4-hydroxybenzoic acid(3),4-hydroxyphenylacetic acid(4),3-hydroxyphenylacetic acid(5),3-methylsulfinyl propionic acid(6),phenylacetic acid(7),(S)-N-nitroso-1-amino-p-hydroxy phenylethanol(8),2-phenylacetamide(9),p-hydroxybenzaldehyde(10),ethyl 2-(4-hydroxyphenyl)acetate(11),dibutyl phthalate(12),5,5'-dimethoxybiphenyl-2,2'-diol(13),3-indolealdehyde(14),N-acetyl-L-phenylalanine(15),9-hydroxy-10E,12Z-octadecadienoic acid(16),9-hydroxy-10E,12E-octadecadienoic acid(17),(6E)-5-methylene-6-tetradecenoic acid(18).CONCLUSION Compounds 1,3-8 and 10-18 are isolated from Candida sp for the first time.
7.Design,numerical simulation and experimental study of novel oxygenator
Ming-Hao YUE ; Shi-Yao ZHANG ; Ji-Nian LI ; Hui-Chao LIU ; Zi-Hua SU ; Ya-Wei WANG ; Zeng-Sheng CHEN ; Shi-Hang LIN ; Jin-Yu LI ; Ya-Ke CHENG ; Yong-Fei HU ; Cun-Ding JIA ; Ming-Zhou XU
Chinese Medical Equipment Journal 2024;45(3):23-28
Objective To design a novel oxygenator to solve the existing problems of extracorporeal membrane oxygenation(ECMO)machine in high transmembrane pressure difference,low efficiency of blood oxygen exchange and susceptibility to thrombosis.Methods The main body of the oxygenator vascular access flow field was gifted with a flat cylindrical shape.The topology of the vascular access was modeled in three dimensions,and the whole flow field was cut into a blood inlet section,an inlet buffer,a heat exchange zone,a blood oxygen exchange zone,an outlet buffer and a blood outlet section.The oxygenator was compared with Quadrox oxygenator by means of ANSYS FLUENT-based simulation and prototype experiments.Results Simulation calculations showed the oxygenator designed was comparable to the clinically used ones in general,and gained advantages in transmembrane pressure difference,blood oxygen exchange and flow uniformity.Experimental results indicated that the oxygenator behaved better than Quadrox oxygenator in transmembrane pressure difference and blood oxygen exchange.Conclusion The oxygenator has advantages in transmem-brane pressure difference,temperature change,blood oxygen ex-change and low probability of thrombosis.[Chinese Medical Equipment Journal,2024,45(3):23-28]
8.Research on evaluation and screening indicator for emergency ventilators
Qin-Qi YAO ; Ming-Kang TANG ; Long-Ying YE ; Pei-Pei ZHANG ; Ke-Sheng WANG ; Dan LING ; Qian-Hong HE ; Zhu CHEN
Chinese Medical Equipment Journal 2024;45(7):8-16
Objective To propose an evaluation and screening indicator for the reliability of emergency ventilators.Methods Firstly,a regression model was used to clean the data and remove noise to ensure the accuracy of regression analysis.Then,four groups of highly correlated data combinations,including inspiratory tidal volume-minute expiratory volume,peak airway pressure-minute expiratory volume,peak airway pressure-inspiratory tidal volume and positive end-expiratory pressure(PEEP)-mean airway pressure,were determined with the methods of curve fitting and transfer function,and the difference between the theoretical output and the actual output of the data combinations was regarded as an indicator to judge whether the ventilator functioned well or not;finally,the indicator proposed was applied to single and multiple ventilators,and the feasibility of the indicator was determined by the proportion of the ventilators functioning well.Results The evaluation results with a single ventilator showed the four groups of data combinations had the actual output fitted well with the theoretical output,and all the differences between the theoretical output and the actual output were lower than the threshold;the results with multiple ventilators indicated there were 71.49%ventilators functioning well,which was very close to the actual result that 72%ventilators behaved well.Conclusion The evaluation and screening indicator for emergency ventilators has high feasibility,and theoretical support is provided for reliability assessment and selection of series of emergency treatment equipment.[Chinese Medical Equipment Journal,2024,45(7):8-16]
9.Modal testing study of three-axis manned centrifuge under elastic boundary conditions
Hai-Xia WANG ; Ke JIANG ; Zhao JIN ; Yi WANG ; Li-Hui ZHANG ; Yan XU ; Cong WANG ; Ming-Hao YANG ; Jing-Hui YANG ; Xiao-Xue ZHANG ; Yuan-Jing ZHENG ; Bao-Hui LI
Chinese Medical Equipment Journal 2024;45(8):38-43
Objective To explore the modal testing method for the three-axis manned centrifuge under elastic boundary conditions with considerations on its complicated structure and high rotational inertia.Methods Modal testing was carried out with a three-axis manned centrifuge under elastic boundary conditions as the subject and a force hammer as the excitation source according to GJB 2706A-2008 Modal tests method for spacecraft and GB/T 11349.3-1992 Experimental determination of mechnical mobility measurements using impact excitation.Four times of hammering were carried out at each excitation position,and the data of the four times of hammering underwent linear average computation.Data acquisition was implemented with a three-axis accelerometer and a 64-channel data collector,and the modal data were analyzed using a frequency response function based on the Test.Lab modal test and analysis software.Results The coherence coefficient of the excitation signal was not lower than 0.8 in the 30 Hz band;the first three orders of the system's intrinsic vibrations were all torsional vibrations,with the frequencies of 9.15,15.66 and 19.22 Hz,respectively;the first order frequency of the system was about 9.15 Hz for both Z18 and Z21 excitation positions,and each of the second and third order frequencies similar situations were observed for also had a roughly equal value for the two excitation positions.Conclusion The force hammer testing method is applicable for the modal testing of the three-axis manned centrifuge,ensuring equipment safety and subject comfort.Referen-ces are provided for the following structural optimization design.[Chinese Medical Equipment Journal,2024,45(8):38-43]
10.Design and implementation of high precision ear pulse wave physiological signal detection device for human centrifuge training
Ke JIANG ; Ming-Hao YANG ; Hai-Xia WANG ; Bao-Hui LI ; Jing-Hui YANG ; Xiao-Xue ZHANG ; Zhong-Zheng GUO ; Xiao-Yang WEI
Chinese Medical Equipment Journal 2024;45(9):35-40
Objective To design and implement a high-precision ear pulse wave physiological signal detection device for human centrifuge training to solve the problems in measurement and calibration of pilot ear pulse wave signal during human centrifuge training.Methods The high-precision ear pulse wave physiological signal detection device was composed of an ear pulse wave acquisition sensor,a signal acquisition and control unit and a host signal processing module.The ear pulse wave acquisition sensor had an ear-clip-like shape and consisted of an outer shell,an inner shell and an elastic steel plate;the signal acquisition and control unit was made up of an power supply module,a constant voltage module for the light source,a signal acquisition module,a master control module and a data transmission module,which had its software developed with an embedded system;the host signal processing module divided the signal processing into 2 phases of signal pre-processing and pulse wave signal monitoring and display.The detection performance of the device was verified by using a physiological electrical signal calibrator to test the ear pulse wave signals detected with the device;the effectiveness and stability of the device were validated by implementing human centrifuge training experiments with different loads.Results The voltage measurement error,amplitude-frequency characteristics and common mode rejection ratio detected by this device were all within the permitted ranges of JJG 760-2003 Verification Regulation for Electro Cardiac Monitor and JJG 954-2019 Verification Regulation of Digital Electroencephalographs;the device was capable of detecting the ear pulse wave signals of pilot during human centrifuge training in real time with little interference from motion and stable signal quality.Conclusion The device can accurately clarify the changes in the amplitude of the pilot's ear pulse wave during human centrifuge training and effectively reflect the changes in the pilot's cerebral blood flow under positive acceleration.[Chinese Medical Equipment Journal,2024,45(9):35-40]

Result Analysis
Print
Save
E-mail