1.Preliminary efficacy observation of 3D printed functional spinal external fixation brace combined with McKenzie therapy in the treatment of lumbar disc herniation.
Ning-Xia WANG ; Ping CHEN ; Hai-Dong WANG ; Jing JI ; Fang-Hong NIAN ; Xin LIU ; Chong-Fei JIN ; Duo-Ming ZHAO ; Hao-Lin LI ; Wei-Gang CHENG ; Gui-Lin LAI ; Guo-Biao WU
China Journal of Orthopaedics and Traumatology 2025;38(10):1047-1054
OBJECTIVE:
To observe the clinical efficacy of 3D printing spinal external fixator combined with McKenzie therapy for patients with lumbar dics herniation (LDH).
METHODS:
Sixty patients with LDH between January 2022 and January 2023 were enrolled. Among them, 30 patients were given McKinsey training. According to different treatment methods, all patients were divided into McKenzie group and McKenzie + 3D printing group, 30 patients in each group. The McKenzie group provided McKenzie therapy. The McKenzie + 3D printing group were treated with 3D printing spinal external fixation brace on the basis of McKenzie therapy. Patients in both groups were between 25 and 60 years of age and had their first illness. In the McKenzie group, there were 19 males and 11 females, with an average age of (48.57±5.86) years old, and the disease duration was (7.03 ±2.39) months. The McKenzie + 3D printing group, there were 21 males and 9 females, with an average age of (48.80±5.92) years old, and the disease duration was(7.30±2.56) months. Pain was evaluated using the visual analogue scale (VAS), and lumbar spine function was assessed using the Oswestry disability index (ODI) and the Japanese Orthopaedic Association (JOA) score. VAS, ODI and JOA scores were compared between two groups before treatment and at 1, 3, 6, 9 and 12 months after treatment.
RESULTS:
All patients were followed up for 12 months. The VAS for the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(6.533±0.860), (5.133±1.008), (3.933±0.868), (2.900±0.759), (2.067±0.640), (1.433±0.504), respectively. In the McKenzie group, the corresponding scores were (6.467±0.860), (5.067±1.048), (4.600±0.968), (3.533±1.008), (2.567±0.728), (1.967±0.809), respectively. The ODI of the McKenzie group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were (41.033±6.810)%, (37.933±6.209)%, (35.467±6.962)%, (27.567±10.081)%, (20.800±7.531)%, (13.533±5.158)%, respectively. For the McKenzie combined with 3D printing group, the corresponding ODI were(38.033±5.605)%, (33.000±6.192)%, (28.767±7.045)%, (22.200±5.517)%, (17.700±4.836)%, (11.900±2.771)%, respectively. The JOA scores of the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(8.900±2.074), (13.133±2.330), (15.700±3.583), (20.400±3.480), (22.267±3.084), (24.833±2.640), respectively. In the McKenzie group, the corresponding scores were(9.200±2.091), (12.267±2.406), (15.333±3.198), (18.467±2.240), (20.133±2.751), (22.467±2.849), respectively. Before the initiation of treatment, no statistically significant differences were observed in the VAS, ODI, and JOA scores between two groups (P>0.05). At 3, 6, 9, and 12 months post-treatment, the VAS in the McKenzie combined with 3D printing group was significantly lower than that in the McKenzie group, and the difference was statistically significant (P<0.05). The comparison of ODI between two groups at 1, 3, 6, 9, and 12 months post-treatment revealed statistically significant differences (P<0.05). At 6, 9, and 12 months post-treatment, the JOA score in the McKenzie combined with 3D printing group was significantly higher than that in the McKenzie-only group, and the difference was statistically significant (P<0.05).
CONCLUSION
The combination of 3D printed functional spinal external fixation brace with McKenzie therapy can significantly improve and maintain lumbar function in patients with LDH.
Humans
;
Male
;
Female
;
Middle Aged
;
Printing, Three-Dimensional
;
Intervertebral Disc Displacement/surgery*
;
External Fixators
;
Lumbar Vertebrae/surgery*
;
Adult
;
Braces
;
Treatment Outcome
2.Shexiang Tongxin Dropping Pill Improves Stable Angina Patients with Phlegm-Heat and Blood-Stasis Syndrome: A Multicenter, Randomized, Double-Blind, Placebo-Controlled Trial.
Ying-Qiang ZHAO ; Yong-Fa XING ; Ke-Yong ZOU ; Wei-Dong JIANG ; Ting-Hai DU ; Bo CHEN ; Bao-Ping YANG ; Bai-Ming QU ; Li-Yue WANG ; Gui-Hong GONG ; Yan-Ling SUN ; Li-Qi WANG ; Gao-Feng ZHOU ; Yu-Gang DONG ; Min CHEN ; Xue-Juan ZHANG ; Tian-Lun YANG ; Min-Zhou ZHANG ; Ming-Jun ZHAO ; Yue DENG ; Chang-Jiang XIAO ; Lin WANG ; Bao-He WANG
Chinese journal of integrative medicine 2025;31(8):685-693
OBJECTIVE:
To evaluate the efficacy and safety of Shexiang Tongxin Dropping Pill (STDP) in treating stable angina patients with phlegm-heat and blood-stasis syndrome by exercise duration and metabolic equivalents.
METHODS:
This multicenter, randomized, double-blind, placebo-controlled clinical trial enrolled stable angina patients with phlegm-heat and blood-stasis syndrome from 22 hospitals. They were randomized 1:1 to STDP (35 mg/pill, 6 pills per day) or placebo for 56 days. The primary outcome was the exercise duration and metabolic equivalents (METs) assessed by the standard Bruce exercise treadmill test after 56 days of treatment. The secondary outcomes included the total angina symptom score, Chinese medicine (CM) symptom scores, Seattle Angina Questionnaire (SAQ) scores, changes in ST-T on electrocardiogram and adverse events (AEs).
RESULTS:
This trial enrolled 309 patients, including 155 and 154 in the STDP and placebo groups, respectively. STDP significantly prolonged exercise duration with an increase of 51.0 s, compared to a decrease of 12.0 s with placebo (change rate: -11.1% vs. 3.2%, P<0.01). The increase in METs was significantly greater in the STDP group than in the placebo group (change: -0.4 vs. 0.0, change rate: -5.0% vs. 0.0%, P<0.01). The improvement of total angina symptom scores (25.0% vs. 0.0%), CM symptom scores (38.7% vs. 11.8%), reduction of nitroglycerin consumption (100.0% vs. 11.3%), and all domains of SAQ, were significantly greater with STDP than placebo (all P<0.01). The changes in Q-T intervals at 28 and 56 days from baseline were similar between the two groups (both P>0.05). Twenty-five participants (16.3%) with STDP and 16 (10.5%) with placebo experienced AEs (P=0.131), with no serious AEs observed.
CONCLUSION
STDP could improve exercise tolerance in patients with stable angina and phlegm-heat and blood stasis syndrome, with a favorable safety profile. (Registration No. ChiCTR-IPR-15006020).
Humans
;
Double-Blind Method
;
Drugs, Chinese Herbal/adverse effects*
;
Male
;
Female
;
Middle Aged
;
Angina, Stable/physiopathology*
;
Aged
;
Syndrome
;
Treatment Outcome
;
Placebos
;
Tablets
3.Variation rules of main secondary metabolites in Hedysari Radix before and after rubbing strip
Xu-Dong LUO ; Xin-Rong LI ; Cheng-Yi LI ; Peng QI ; Ting-Ting LIANG ; Shu-Bin LIU ; Zheng-Ze QIANG ; Jun-Gang HE ; Xu LI ; Xiao-Cheng WEI ; Xiao-Li FENG ; Ming-Wei WANG
Chinese Traditional Patent Medicine 2024;46(3):747-754
AIM To investigate the variation rules of main secondary metabolites in Hedysari Radix before and after rubbing strip.METHODS UPLC-MS/MS was adopted in the content determination of formononetin,ononin,calycosin,calycosin-7-glucoside,medicarpin,genistein,luteolin,liquiritigenin,isoliquiritigenin,vanillic acid,ferulic acid,γ-aminobutyric acid,adenosine and betaine,after which cluster analysis,principal component analysis and orthogonal partial least squares discriminant analysis were used for chemical pattern recognition to explore differential components.RESULTS After rubbing strip,formononetin,calycosin,liquiritigenin and γ-aminobutynic acid demonstrated increased contents,along with decreased contents of ononin,calycosin-7-glucoside and vanillic acid.The samples with and without rubbing strip were clustered into two types,calycosin-7-glucoside,formononetin,γ-aminobutynic acid,vanillic acid,calycosin-7-glucoside and formononetin were differential components.CONCLUSION This experiment clarifies the differences of chemical constituents in Hedysari Radix before and after rubbing strip,which can provide a reference for the research on rubbing strip mechanism of other medicinal materials.
4.A reporter gene assays for bioactivity determination of human chorinonic gonadotropin
Ying HUANG ; Xiao-ming ZHANG ; He-yang LI ; Lü-yin WANG ; Hui ZHANG ; Ping LÜ ; Jing LI ; Xiang-dong GAO ; Cheng-gang LIANG
Acta Pharmaceutica Sinica 2024;59(2):432-438
This study constructed a LHCGR-CRE-luc-HEK293 transgenic cell line according to the activation of the cAMP signaling pathway after recombinant human chorionic gonadotropin binding to the receptor. The biological activity of recombinant human chorionic gonadotropin was assayed using a luciferase assay system. The relative potency of the samples was calculated using four-parameter model. And the method conditions were optimized to validate the specificity, relative accuracy, precision and linearity of the method. The results showed that there was a quantitative potency relationship of human chorinonic gonadotropin (hCG) in the method and it was in accordance with the four-parameter curve. After optimization, the conditions were determined as hCG dilution concentration of 2.5 μg·mL-1, dilution ratio of 1∶4, cell number of 10 000-15 000 cells/well, and induction time of 6 h. The method had good specificity, relative accuracy with relative bias ranging from -8.9% to 3.4%, linear regression equation correlation coefficient of 0.996, intermediate precision geometric coefficient of variation ranging from 3.3% to 15.0%, and linearity range of 50% to 200%. This study successfully established and validated a reporter gene method to detect hCG biological activity, which can be used for hCG biological activity assay and quality control.
5.Robotic visualization system-assisted microsurgical reconstruction of the reproductive tract in male rats
Zheng LI ; Jian-Jun DONG ; Ming LIU ; Xun-Zhu WU ; Ren-Feng JIA ; San-Wei GUO ; Kai MENG ; Chen-Cheng YAO ; Er-Lei ZHI ; Gang LIU ; Da-Xian TAN ; Zheng LI ; Peng LI
National Journal of Andrology 2024;30(8):675-680
Objective:To evaluate the safety and efficiency of robotic visualization system(RVS)-assisted microsurgical re-construction of the reproductive tract in male rats and the satisfaction of the surgeons.Methods:We randomly divided 8 adult male SD rats into an experimental and a control group,the former treated by RVS-assisted microsurgical vasoepididymostomy(VE)or vaso-vasostomy(VV),and the latter by VE or VV under the standard operating microscope(SOM).We compared the operation time,me-chanical patency and anastomosis leakage immediately after surgery,and the surgeons'satisfaction between the two groups.Results:No statistically significant difference was observed the operation time between the experimental and the control groups,and no anasto-mosis leakage occurred after VV in either group.The rate of mechanical patency immediately after surgery was 100%in both groups,and that of anastomosis leakage after VE was 16.7%in the experimental group and 14.3%in the control.Compared with the control group,the experimental group achieved dramatically higher scores on visual comfort(3.00±0.76 vs 4.00±0.53,P<0.05),neck/back comfort(2.75±1.16 vs 4.38±1.06,P<0.01)and man-machine interaction(3.88±1.55 va 4.88±0.35,P<0.05).There were no statistically significant differences in the scores on image definition and operating room suitability between the two groups.Conclusion:RVS can be used in microsurgical reconstruction of the reproductive tract in male rats and,with its advantages over SOM in ergonomic design and image definition,has a potential application value in male reproductive system micosurgery.
7.Quality evaluation of Qilong Zhuang'er oral liquid based on UHPLC-Q-exactive orbitrap MS and chemometrics analysis
Xiao-min CUI ; Ming-zhi DONG ; Hong ZHANG ; Jian-gang LI ; Hui REN ; Jing HU ; Wen-jing LU ; Juan CHEN ; Xue MENG ; Zhi-yong CHEN
Acta Pharmaceutica Sinica 2023;58(6):1655-1662
An UHPLC-Q-exactive orbitrap MS method for the simultaneous determination of 19 chemical components in Qilong Zhuang'er oral liquid was established and the quality differences between different batches of samples was compared by chemometric analysis to provide a basis for the quality evaluation of the preparation. The contents of allantoin,
8.Diagnostic values of nuclear score combined with cyclin D1 immunocytochemistry in indeterminate thyroid follicular nodules in preoperative fine needle aspiration.
Shu Rong HE ; Long Teng LIU ; Rong Ming CHEN ; Meng Ge WANG ; Song Tao HU ; Gang MIAO ; Lan CHEN ; Dong Ge LIU
Chinese Journal of Pathology 2023;52(7):696-701
Objective: To assess the feasibility of nuclear score combined with cyclin D1 immunocytochemistry in classifying indeterminate thyroid nodules with fine-needle aspiration (FNA) cytological diagnosis of Bethesda category Ⅲ-Ⅴ. Methods: A consecutive cohort of 118 thyroid FNA specimens with indeterminate diagnosis (TBSRTC category Ⅲ-Ⅴ) and available histopathologic follow-up data were collected between December 2018 and April 2022 at the Department of Pathology, Beijing Hospital, China. These cases were subjected to cytological evaluation and cyclin D1 immunocytochemistry. The optimal cut-off points of a simplified nuclear score and the percentage of cyclin D1-positive cells for the diagnosis of malignancy or low-risk neoplasm were determined using the receiver operating characteristic (ROC) curves and area under the ROC curve (AUC). The specificity, sensitivity, positive predictive value (PPV) and negative predictive value (NPV) of nuclear score and cyclin D1 immunostaining were evaluated from the crosstabs based on cut-off points. The diagnostic accuracy of simplified nuclear score combined with cyclin D1 immunostaining was estimated using ROC curve analysis. Results: Nuclear grooves, intra-nuclear inclusions and chromatin clearing were more commonly found in malignancy/low-risk neoplasms than benign lesions (P=0.001, P=0.012 and P=0.001 respectively). A cut-off point of≥2 for the simplified nuclear score was sensitive for defining malignancy/low-risk neoplasm, and its PPV, NPV, sensitivity and specificity were 93.6%, 87.5%, 99.0% and 50.0% respectively. A positive cut-off point of 10% positive thyroid cells in cyclin D1 immunostaining demonstrated sensitivity of 88.5%, specificity of 100%, PPV of 100% and NPV of 53.8% for correctly detecting thyroid malignancy or low-risk neoplasm. The sensitivity and PPV of simplified nuclear score combined with cyclin D1 immunostaining were 93.3% and 100%, respectively. Both specificity and NPV were maintained at high levels (100% and 66.7%, respectively). The diagnostic accuracy of simplified nuclear score combined with cyclin D1 immunostaining in detecting thyroid malignancy/low-risk neoplasm was increased to 94.1% compared to using either of them alone. Conclusions: Combing simplified nuclear score and cyclin D1 immunostaining on FNA cytology specimens can increase the diagnostic accuracy in classifying thyroid nodules of indeterminate cytological categories. Thus, this supplementary approach provides a simple, accurate, and convenient diagnostic method for cytopathologists so that may reduce unnecessary thyroidectomies.
Humans
;
Thyroid Nodule/pathology*
;
Biopsy, Fine-Needle
;
Cyclin D1
;
Immunohistochemistry
;
Thyroid Neoplasms/pathology*
;
Retrospective Studies
9.A comparative study for the efficacies of transaxillary non-inflatable endoscopic surgery versus traditional surgery for papillary thyroid carcinoma.
Xiao Lei CHEN ; Chao LI ; Yu Qiu ZHOU ; Yong Cong CAI ; Yu Dong NING ; Chun Yan SHUI ; Xu WANG ; Zi Xun ZENG ; Gang QIN ; Ming Hua GE ; Chuan Ming ZHENG
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(4):351-357
Objective: To compare the efficacies between open surgery and axillary non-inflatable endoscopic surgery in papillary thyroid carcinoma (PTC). Methods: A retrospective analysis was performed on 343 patients with unilateral PTC treated by traditional open surgery (201 cases) and transaxillary non-inflating endoscopic surgery (142 cases) from May 2019 to December 2021 in the Head and Neck Surgery of Sichuan Cancer Hospital. Among them, 97 were males and 246 were females, aged 20-69 years. 1∶1 propensity score matching (PSM) was performed on the enrolled patients, and the basic characteristics, perioperative clinical outcomes, postoperative complications, postoperative quality of life (Thyroid Cancer-Specific Quality of Life), aesthetic satisfaction and other aspects of the two groups were compared after successful matching. SPSS 26.0 software was used for statistical analysis. Results: A total of 190 patients were enrolled after PSM, with 95 cases in open group and 95 cases in endoscopic group. Intraoperative blood losses for endoscopic and open groups were [20 (20) ml vs. 20 (10) ml, M (IQR), Z=-2.22], postoperative drainage volumes [170 (70)ml vs. 101 (55)ml, Z=-7.91], operative time [135 (35)min vs. 95 (35)min, Z=-7.34], hospitalization cost [(28 188.7±2 765.1)yuan vs. (25 643.5±2 610.7)yuan, x¯±s, t=0.73], postoperative hospitalization time [(3.1±0.9)days vs. (2.6±0.9)days, t=-3.24], and drainage tube placement time [(2.5±0.8) days vs. (2.0±1.0)days, t=-4.16], with statistically significant differrences (all P<0.05). There was no significant difference in surgical complications (P>0.05). There were significant diffferences between two groups in the postoperative quality of life scores in neuromuscular, psychological, scar and cold sensation (all P<0.05), while there were no statistically significant differences in other quality of life scores (all P>0.05). In terms of aesthetic satisfaction 6 months after surgery, the endoscopic group was better than the open group, with statistically significant difference (χ2=41.47, P<0.05). Conclusion: Endoscopic thyroidectomy by a gasless unilateral axillary approach is a safe and reliable surgical method, which has remarkable cosmetic effect and can improve the postoperative quality of life of patients compared with the traditional thyroidectomy.
Male
;
Female
;
Humans
;
Thyroid Cancer, Papillary/surgery*
;
Retrospective Studies
;
Quality of Life
;
Thyroid Neoplasms/pathology*
;
Endoscopy
;
Thyroidectomy/methods*
10.Quality evaluation and multi-spectral identification of origin herbs of Lonicerae Japonicae Flos based on grey correlation-TOPSIS method.
Ji-Jing DONG ; Lu-Ming QI ; Ke WANG ; Yu-Gang DING ; Yun-Tong MA
China Journal of Chinese Materia Medica 2023;48(10):2713-2724
The grey correlation-TOPSIS method was used to evaluate the quality of the origin herbs of Lonicerae Japonicae Flos, and the Fourier transform near-infrared(NIR) and mid-infrared(MIR) spectroscopy was applied to establish the identification model of origin herbs of Lonicerae Japonicae Flos by combining chemometrics and spectral fusion strategies. The content of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, caffeic acid, secoxyloganin, isoquercitrin, isochlorogenic acid B, isochlorogenic acid A, and isochlorogenic acid C in six origin herbs of Lonicerae Japonicae Flos was determined by high-performance liquid chromatography(HPLC), and their quality was evaluated by the grey correlation-TOPSIS method. The Fourier transform NIR and MIR spectra of six origin herbs of Lonicerae Japonicae Flos(Lonicera japonica, L. macranthoides, L. hypoglauca, L. fulvotomentosa, L. confuse, and L. similis) were collected. At the same time, principal component analysis(PCA), support vector machine(SVM), and spectral data fusion technology were combined to determine the optimal identification method for the origin herbs of Lonicerae Japonicae Flos. There were differences in the quality of the origin herbs of Lonicerae Japonicae Flos. Specifically, there were significant differences between L. japonica and the other five origin herbs(P<0.01). The quality of L. similis was significantly different from that of L. fulvotomentosa, L. macranthoides, and L. hypoglauca(P=0.008, 0.027, 0.01), and there were also significant differences in the quality of L. hypoglauca and L. confuse(P=0.001). The PCA and SVM 2D models based on a single spectrum could not be used for the effective identification of the origin herbs of Lonicerae Japonicae Flos. The data fusion combined with the SVM model further improved the identification accuracy, and the identification accuracy of the mid-level data fusion reached 100%. Therefore, the grey correlation-TOPSIS method can be used to evaluate the quality of the origin herbs of Lonicerae Japonicae Flos. Based on the infrared spectral data fusion strategy and SVM chemometric model, it can accurately identify the origin herbs of Lonicerae Japonicae Flos, which can provide a new method for the origin identification of medicinal materials of Lonicerae Japonicae Flos.
Drugs, Chinese Herbal/chemistry*
;
Flowers/chemistry*
;
Quality Control
;
Lonicera/chemistry*
;
Chromatography, High Pressure Liquid/methods*

Result Analysis
Print
Save
E-mail