1.Applications of EEG Biomarkers in The Assessment of Disorders of Consciousness
Zhong-Peng WANG ; Jia LIU ; Long CHEN ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(4):899-914
Disorders of consciousness (DOC) are pathological conditions characterized by severely suppressed brain function and the persistent interruption or loss of consciousness. Accurate diagnosis and evaluation of DOC are prerequisites for precise treatment. Traditional assessment methods are primarily based on behavioral scales, which are inherently subjective and rely on observable behaviors. Moreover, traditional methods have a high misdiagnosis rate, particularly in distinguishing minimally conscious state (MCS) from vegetative state/unresponsive wakefulness syndrome (VS/UWS). This diagnostic uncertainty has driven the exploration of objective, reliable, and efficient assessment tools. Among these tools, electroencephalography (EEG) has garnered significant attention for its non-invasive nature, portability, and ability to capture real-time neurodynamics. This paper systematically reviews the application of EEG biomarkers in DOC assessment. These biomarkers are categorized into 3 main types: resting-state EEG features, task-related EEG features, and features derived from transcranial magnetic stimulation-EEG (TMS-EEG). Resting-state EEG biomarkers include features based on spectrum, microstates, nonlinear dynamics, and brain network metrics. These biomarkers provide baseline representations of brain activity in DOC patients. Studies have shown their ability to distinguish different levels of consciousness and predict clinical outcomes. However, because they are not task-specific, they are challenging to directly associate with specific brain functions or cognitive processes. Strengthening the correlation between resting-state EEG features and consciousness-related networks could offer more direct evidence for the pathophysiological mechanisms of DOC. Task-related EEG features include event-related potentials, event-related spectral modulations, and phase-related features. These features reveal the brain’s responses to external stimuli and provide dynamic information about residual cognitive functions, reflecting neurophysiological changes associated with specific cognitive, sensory, or behavioral tasks. Although these biomarkers demonstrate substantial value, their effectiveness rely on patient cooperation and task design. Developing experimental paradigms that are more effective at eliciting specific EEG features or creating composite paradigms capable of simultaneously inducing multiple features may more effectively capture the brain activity characteristics of DOC patients, thereby supporting clinical applications. TMS-EEG is a technique for probing the neurodynamics within thalamocortical networks without involving sensory, motor, or cognitive functions. Parameters such as the perturbational complexity index (PCI) have been proposed as reliable indicators of consciousness, providing objective quantification of cortical dynamics. However, despite its high sensitivity and objectivity compared to traditional EEG methods, TMS-EEG is constrained by physiological artifacts, operational complexity, and variability in stimulation parameters and targets across individuals. Future research should aim to standardize experimental protocols, optimize stimulation parameters, and develop automated analysis techniques to improve the feasibility of TMS-EEG in clinical applications. Our analysis suggests that no single EEG biomarker currently achieves an ideal balance between accuracy, robustness, and generalizability. Progress is constrained by inconsistencies in analysis methods, parameter settings, and experimental conditions. Additionally, the heterogeneity of DOC etiologies and dynamic changes in brain function add to the complexity of assessment. Future research should focus on the standardization of EEG biomarker research, integrating features from resting-state, task-related, and TMS-EEG paradigms to construct multimodal diagnostic models that enhance evaluation efficiency and accuracy. Multimodal data integration (e.g., combining EEG with functional near-infrared spectroscopy) and advancements in source localization algorithms can further improve the spatial precision of biomarkers. Leveraging machine learning and artificial intelligence technologies to develop intelligent diagnostic tools will accelerate the clinical adoption of EEG biomarkers in DOC diagnosis and prognosis, allowing for more precise evaluations of consciousness states and personalized treatment strategies.
2.Color-component correlation and mechanism of component transformation of processed Citri Reticulatae Semen.
Kui-Lin ZHU ; Jin-Lian ZOU ; Xu-Li DENG ; Mao-Xin DENG ; Hai-Ming WANG ; Rui YIN ; Zhang-Xian CHEN ; Yun-Tao ZHANG ; Hong-Ping HE ; Fa-Wu DONG
China Journal of Chinese Materia Medica 2025;50(9):2382-2390
High-performance liquid chromatography(HPLC) was used to determine the content of three major components in Citri Reticulatae Semen(CRS), including limonin, nomilin, and obacunone. The chromaticity of the CRS sample during salt processing and stir-frying was measured using a color difference meter. Next, the relationship between the color and content of the salt-processed CRS sample was investigated through correlation analysis. By integrating the oil bath technique for processing simulation with HPLC, the changes in the relative content of nomilin and its transformation products were analyzed, with its structural transformation pattern during processing identified. Additionally, RAW264.7 cells were induced with lipopolysaccharides(LPSs) to establish an inflammatory model, and the anti-inflammatory activity of nomilin and its transformation product, namely obacunone was evaluated. The results indicated that as processing progressed, E~*ab and L~* values showed a downward trend; a~* values exhibited a slow increase over a certain period, followed by no significant changes, and b~* values remained stable with no significant changes over a certain period and then started to decrease. The limonin content remained barely unchanged; the nomilin content decreased, and the obacunone increased significantly. The changing trends in content and color parameters during salt-processing and stir-frying were basically consistent. The content of nomilin and obacunone was significantly correlated with the colorimetric values(L~*, a~*, b~*, and E~*ab), while limonin content showed no significant correlation with these values. By analyzing HPLC patterns of nomylin at different heating temperatures and time, it was found that under conditions of 200-250 ℃ for heating of 5-60 min, the content of nomilin significantly decreased, while the obacunone content increased pronouncedly. The in vitro anti-inflammatory activity results indicated that compared to the model group, the group with a high concentration of nomilin and the groups with varying concentrations of obacunone showed significantly reduced release of nitric oxide(NO)(P<0.01). When both were at the same concentration, obacunone showed better performance in inhibiting NO release. In this study, the obvious correlation between the color and content of major components during the processing of CRS samples was identified, and the dynamic patterns of quality change in CRS samples during processing were revealed. Additionally, the study revealed and confirmed the transformation of nomilin into obacunone during processing, with the in vitro anti-inflammatory activity of obacunone significantly greater than that of nomilin. These findings provided a scientific basis for CRS processing optimization, tablet quality control, and its clinical application.
Mice
;
Animals
;
Drugs, Chinese Herbal/pharmacology*
;
RAW 264.7 Cells
;
Limonins/chemistry*
;
Chromatography, High Pressure Liquid
;
Citrus/chemistry*
;
Color
;
Benzoxepins/chemistry*
;
Anti-Inflammatory Agents/chemistry*
3.Expert consensus on evaluation index system construction for new traditional Chinese medicine(TCM) from TCM clinical practice in medical institutions.
Li LIU ; Lei ZHANG ; Wei-An YUAN ; Zhong-Qi YANG ; Jun-Hua ZHANG ; Bao-He WANG ; Si-Yuan HU ; Zu-Guang YE ; Ling HAN ; Yue-Hua ZHOU ; Zi-Feng YANG ; Rui GAO ; Ming YANG ; Ting WANG ; Jie-Lai XIA ; Shi-Shan YU ; Xiao-Hui FAN ; Hua HUA ; Jia HE ; Yin LU ; Zhong WANG ; Jin-Hui DOU ; Geng LI ; Yu DONG ; Hao YU ; Li-Ping QU ; Jian-Yuan TANG
China Journal of Chinese Materia Medica 2025;50(12):3474-3482
Medical institutions, with their clinical practice foundation and abundant human use experience data, have become important carriers for the inheritance and innovation of traditional Chinese medicine(TCM) and the "cradles" of the preparation of new TCM. To effectively promote the transformation of new TCM originating from the TCM clinical practice in medical institutions and establish an effective evaluation index system for the transformation of new TCM conforming to the characteristics of TCM, consensus experts adopted the literature research, questionnaire survey, Delphi method, etc. By focusing on the policy and technical evaluation of new TCM originating from the TCM clinical practice in medical institutions, a comprehensive evaluation from the dimensions of drug safety, efficacy, feasibility, and characteristic advantages was conducted, thus forming a comprehensive evaluation system with four primary indicators and 37 secondary indicators. The expert consensus reached aims to encourage medical institutions at all levels to continuously improve the high-quality research and development and transformation of new TCM originating from the TCM clinical practice in medical institutions and targeted at clinical needs, so as to provide a decision-making basis for the preparation, selection, cultivation, and transformation of new TCM for medical institutions, improve the development efficiency of new TCM, and precisely respond to the public medication needs.
Medicine, Chinese Traditional/standards*
;
Humans
;
Consensus
;
Drugs, Chinese Herbal/therapeutic use*
;
Surveys and Questionnaires
4.Quality evaluation of Hibisci Mutabilis Folium based on fingerprint and quantitative analysis of multi-components by single-marker method.
Ming CHEN ; Zhen-Hai YUAN ; Xuan TANG ; Dong WANG ; Zhi-Yong ZHENG ; Jing FENG ; Dai-Zhou ZHANG ; Fang WANG
China Journal of Chinese Materia Medica 2025;50(16):4619-4629
To improve the quality evaluation system of Hibisci Mutabilis Folium, this study established high performance liquid chromatography(HPLC) fingerprints of Hibisci Mutabilis Folium and evaluated the quality differences of medicinal materials from different places of production by chemometrics. Furthermore, a content measurement method of differential components was established based on quantitative analysis of multi-components by single-marker(QAMS). The fingerprints of 17 batches of Hibisci Mutabilis Folium from different places of production were constructed, with a total of 19 common peaks marked and seven components confirmed. The similarity between the sample fingerprints and the reference fingerprints ranged from 0.890 to 0.974. By utilizing principal component analysis(PCA), hierarchical cluster analysis(HCA), and orthogonal partial least squares-discriminant analysis(OPLS-DA), the chemical patterns of fingerprints were identified. Five components that could be used to evaluate the quality differences of Hibisci Mutabilis Folium were screened, namely peak 6(quercetin 3-O-β-robinobioside), peak 7(rutin), peak 9(kaempferol-3-O-β-robinobioside), peak 10(kaempferol-3-O-rutinoside), and peak 14(tiliroside). The relative correction factors of isoquercitrin, kaempferol-3-O-β-robinobioside, kaempferol-3-O-rutinoside, kaempferol-3-O-β-D-glucoside, and tiliroside were measured with rutin as the internal reference. The QAMS method was established for the content measurement of six flavonoids, and the results showed there was no significant difference compared to the results obtained by an external standard method. In summary, the HPLC fingerprints and QAMS method established in the study, demonstrating stability and accuracy, can provide a reference for the overall quality evaluation of Hibisci Mutabilis Folium.
Chromatography, High Pressure Liquid/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Principal Component Analysis
5.Cross-session motor imagery-electroencephalography decoding with Riemannian spatial filtering and domain adaptation.
Lincong PAN ; Xinwei SUN ; Kun WANG ; Yupei CAO ; Minpeng XU ; Dong MING
Journal of Biomedical Engineering 2025;42(2):272-279
Motor imagery (MI) is a mental process that can be recognized by electroencephalography (EEG) without actual movement. It has significant research value and application potential in the field of brain-computer interface (BCI) technology. To address the challenges posed by the non-stationary nature and low signal-to-noise ratio of MI-EEG signals, this study proposed a Riemannian spatial filtering and domain adaptation (RSFDA) method for improving the accuracy and efficiency of cross-session MI-BCI classification tasks. The approach addressed the issue of inconsistent data distribution between source and target domains through a multi-module collaborative framework, which enhanced the generalization capability of cross-session MI-EEG classification models. Comparative experiments were conducted on three public datasets to evaluate RSFDA against eight existing methods in terms of classification accuracy and computational efficiency. The experimental results demonstrated that RSFDA achieved an average classification accuracy of 79.37%, outperforming the state-of-the-art deep learning method Tensor-CSPNet (76.46%) by 2.91% ( P < 0.01). Furthermore, the proposed method showed significantly lower computational costs, requiring only approximately 3 minutes of average training time compared to Tensor-CSPNet's 25 minutes, representing a reduction of 22 minutes. These findings indicate that the RSFDA method demonstrates superior performance in cross-session MI-EEG classification tasks by effectively balancing accuracy and efficiency. However, its applicability in complex transfer learning scenarios remains to be further investigated.
Electroencephalography/methods*
;
Brain-Computer Interfaces
;
Humans
;
Imagination/physiology*
;
Signal Processing, Computer-Assisted
;
Movement/physiology*
;
Signal-To-Noise Ratio
;
Deep Learning
;
Algorithms
6.Early clinical outcomes of 3D-printed individualised customised prostheses in hip revision combined severe bone defect.
Hong-Ping WANG ; Ming-You WANG ; Xiao-Qin YANG ; Zhuo-Dong TANG ; Xun-Zhou SONG ; Yu-Ping LAN
China Journal of Orthopaedics and Traumatology 2025;38(2):163-169
OBJECTIVE:
To explore the early clinical outcomes of 3D printed individualised customised prostheses for in hip revision in patients with combined severe bone defects.
METHODS:
Twenty-two patients from January 2021 to May 2023 underwent hip revision using 3D printed personalised customised prostheses were retrospective analyzed, including 10 males and 12 females, age 28 to 78 with a mean of (58.9±12.8) years old. All of patients were combined with severe bone defects (Parprosky type Ⅲ). Among of them, 9 patients had periprosthetic infections and 13 patients had aseptic prosthesis loosening. All patients were treated with a 3D printed personalised prosthesis protocol, patients with the periprosthetic infection received a second stage revision after infection control. The operation time, preoperative waiting time, intraoperative and postoperative complications were recorded, and the clinical efficacy were evaluated at the final follow-up using the visual analogue scale (VAS) for pain, the Harris hip score.
RESULTS:
One patient was lost to follow-up and the remaining 21 patients were followed up for 10 to 15 with a mean of (12.91±1.44) months after surgery. All patients completed surgery as planned, with an operative time of 135 to 390 with a mean of (165.4±39.3) minutes and a preoperative waiting time of 7 to 16 with a mean of (10.5±3.3) days. Regarding patient complications:one patient had a severe intraoperative periprosthetic femoral fracture due to the combination of severe osteoporosis; one patient had an intraoperative greater trochanteric femur fracture. At the latest follow-up, all patients had good position of the custom-made prosthesis and no loosening of the prosthesis;all patients had good wound healing and no local redness or swelling. The total Harris score at the final follow-up (85.86±7.04) was significantly improved compared to the preoperative (44.86±2.36), P<0.001. The VAS at the last follow-up (2.19±0.87) was significantly improved compared with preoperative (7.41±0.96), P<0.001.
CONCLUSION
The clinical efficacy of 3D-printed personalised customised prosthesis in combined severe bone defect hip revision is satisfactory, but due to the increased preoperative waiting time of the patients and certain risks, certain indications should be mastered when applying in the clinic.
Humans
;
Male
;
Female
;
Printing, Three-Dimensional
;
Middle Aged
;
Aged
;
Adult
;
Retrospective Studies
;
Hip Prosthesis
;
Arthroplasty, Replacement, Hip
;
Reoperation
;
Prosthesis Design
;
Treatment Outcome
7.Experimental study on autologous osteochondral transplantation in the treatment of recurrent anterior dislocation of the shoulder joint with articular cartilage defect in rabbits.
Tao LIU ; Sen FANG ; Fang-Xiang LIU ; Ming-Tao ZHANG ; Zhi-Tao YANG ; Bo-Rong ZHANG ; Jun-Wen LIANG ; Xi-Hao WANG ; Jin JIANG ; Xiang-Dong YUN
China Journal of Orthopaedics and Traumatology 2025;38(6):619-625
OBJECTIVE:
To explore clinical effect of autologous osteochondral transplantation (AOT) in the treatment of recurrent anterior dislocation of the shoulder joint with glenoid cartilage defect in rabbits by establishing a model of recurrent anterior dislocation of the shoulder joint with < 20% glenoid cartilage defect in rabbits.
METHODS:
Twenty-four male New Zealand white rabbits, aged 6-month-old, weighed (2.69±0.17) kg were selected. The labrum of shoulder joint of rabbits was artificially destroyed to establish a model of recurrent anterior dislocation of shoulder joint with cartilage defect. They were divided into AOT surgery group and simple suture group, with 12 rabbits in each group. AOT group were underwent AOT surgery, while simple suture group was treated with simple Bankart suture for recurrent shoulder joint dislocation. At 6 and 12 weeks after operation, 6 rabbits between two groups were sacrificed for sampling. The dietary conditions, activity conditions, mental states of rabbits and healing conditions of grafts in the specimens were observed and compared between two groups. HE staining was used to observe cell creep, cell morphology, inflammatory cell infiltration, fibrochondrocytes and their arrangement. Masson staining was used to observe the formation and arrangement of collagen fibers; Safrane-green staining was used to observe the regeneration of articular cartilage, subchondral bone and bone tissue. Bone mineral density (BMD), bone volume (BV) and trabecular thickness (Tb.Th) between two groups were measured by Micro-CT to evaluate the remodeling of shoulder glenoid bone defects by autologous osteochondral cartilage.
RESULTS:
After different surgical interventions were carried out in both groups of rabbits, at 6 weeks after the operation, the abduction, extension, internal rotation and external rotation of the shoulder joint on the operated side showed limited range of motion compared with the contralateral side, while adduction and forward flexion showed no obvious abnormalities compared with the contralateral side. At 12 weeks after operation, the range motion of tshoulder joints in both groups of rabbits had returned to the state before modeling. The effects of HE staining, Masson staining and safrane-green staining at 12 weeks after operation in both groups were stronger than the staining results at 6 weeks after operation. Moreover, the results of HE staining, Masson staining and safranin fixation green staining in AOT group at 6 and 12 weeks after operation were all higher than those in simple suture group. Micro-CT scan results at 6 and 12 weeks after operation showed that BMD (0.427±0.014), (0.466±0.032) g·cm-3, BV(116.171±3.527), (159.327±3.500) mm3, and Tb.Th (0.230±0.006), (0.285±0.009) mm in AOT group, which were higher than those of simple suture group in BMD(0.358±0.011), (0.384±0.096) g·cm-3, BV(72.657±3.903), (118.713±3.860) mm3, and Tb.Th(0.204±0.009), (0.243±0.007) mm;and the differences were statistically significant (P<0.05).
CONCLUSION
AOT procedure could effectively promote osteogenesis and fibrocartilage regeneration in the cartilage defect area of the shoulder glenoid <20%, which is conducive to reshaping the structure of the shoulder glenoid.
Animals
;
Rabbits
;
Male
;
Transplantation, Autologous
;
Cartilage, Articular/injuries*
;
Shoulder Dislocation/physiopathology*
;
Bone Transplantation
;
Shoulder Joint/surgery*
8.Biomechanical study and clinical application of two osteotomy guide methods in media open wedge high tibial osteotomy operation.
Chao QI ; Xiao-Ming LI ; Dong-Hui GUO ; Qiu-Ling SHI ; Yun-Chao ZHAO ; Jun DONG ; Zheng-Xin MENG ; Xing-Yue WANG
China Journal of Orthopaedics and Traumatology 2025;38(7):698-704
OBJECTIVE:
To explore the effectiveness and feasibility of two osteotomy guides in medial open wedge high tibial osteotomy (MOWHTO).
METHODS:
Clinical data of 103 patients who underwent routine MOWHTO surgery between January 2020 and December 2022 were collected for retrospective analysis. The patients were divided into two groups based on the method of osteotomy guide plate. The control group of 51 patients received traditional osteotomy guide plate technique, including 17 males and 34 females, aged from 48 to 68 years old with an average of(57.93±4.82) years old, with a disease duration ranged from 1 to 8 years with an average of (4.89±1.49) years. The observation group of 52 patients received personalized osteotomy guide plate technique, including 23 males and 29 females, aged from 48 to 69 with an average of (58.22±5.10) years, with a disease duration ranged from 1 to 9 years with an average of(5.10±1.55) years. The perioperative indicators, complications, and knee joint recovery rate were statistically analyzed for both groups, as well as the preoperative and postoperative coagulation function, fibrinogen (FIB), D-dimer (D-D), gait parameters (step frequency, step length, step speed), biomechanical indicators, weight bearing line (WBL), medial proximal tibial angle (MPTA), joint line conergence angle (JLCA), and anterior cruciate ligament (ACL) function (body width, tibial anterior displacement).
RESULTS:
All patients were followed up for 6 months. The intraoperative blood loss, operation time, and number of fluoroscopic views in the observation group were (358.58±93.76) ml, (84.42±8.17) min, and (2.00±0.44) times, respectively, which were all less than those in the control group (465.55±105.38) ml, (96.53±10.51) min, and (6.31±0.58) times (P<0.05). Three days after surgery, the FIB and D-D levels in the observation group were (4.21±0.48) g·L-1 and (204.47±35.59) μg·L-1, respectively, which were both lower than those in the control group (5.56±0.57) g·L-1 and (311.12±42.23) μg·L-1 (P<0.05). Three months after surgery, the step frequency, step length, and step speed in the observation group were (1.89±0.23) steps·s-1, (0.57±0.15) m, and (0.99±0.11) m·s-1, respectively, which were all higher than those in the control group (1.80±0.18) steps·s-1, (0.50±0.14) m, and (0.95±0.09) m·s-1 (P<0.05). Three months after surgery, the WBL and MPTA in the observation group were (45.53±4.41)% and (87.03±8.15)°, respectively, which were both higher than those in the control group (38.38±4.36)% and (83.68±8.50)°, and the JLCA was (2.36±0.24)°, which was lower than that in the control group (2.61±0.33)° (P<0.05). The ACL body width during internal fixation removal was (5.60±0.51) mm, which was greater than that in the control group (5.08±0.56) mm, and the tibial migration was (5.70±0.42) mm, which was less than that in the control group (6.33±0.48) mm (P<0.05). There was no significant difference in the incidence of complications between the two groups (P>0.05). Six months after surgery, there was no significant difference in the recovery rate of knee joint between the two groups (P>0.05).
CONCLUSION
The application of personalized osteotomy guide technique in MOWHTO can help improve knee biomechanics and ACL function, and has less effect on coagulation function and no increase in complications.
Humans
;
Male
;
Female
;
Osteotomy/methods*
;
Middle Aged
;
Tibia/physiopathology*
;
Aged
;
Biomechanical Phenomena
;
Retrospective Studies
;
Osteoarthritis, Knee/physiopathology*
9.Comparison of application and efficacy of domestic HURWA and imported Smith & Nephew Cori robots in total knee arthroplasty.
Ming-You WANG ; Zhuo-Dong TANG ; Yu-Ping LAN ; Heng XIAO ; Ming-Li WANG ; Xun-Zhou SONG ; Hong-Ping WANG
China Journal of Orthopaedics and Traumatology 2025;38(10):1027-1036
OBJECTIVE:
Investigation on the clinical application of HURWA robot and Smith & Nephew Cori robot in total knee arthroplasty(TKA).
METHODS:
A retrospective analysis was performed on 84 patients with knee osteoarthritis who underwent robotic-assisted TKA (RATKA) between June 2023 and March 2025. According to the different robotic systems used, the patients were divided into the domestic HUARUN robotic-assisted total knee arthroplasty group (HRATKA group) and the Smith & Nephew Cori robotic-assisted total knee arthroplasty group (CRATKA group). There were 42 patients in the HRATKA group, including 16 males and 26 females; the age ranged from 56 to 73 years old, with an average of (64.70±8.30) years old;the body mass index (BMI) was (25.10±2.30) kg·m-2;21 cases were on the right side and 21 cases on the left side;in terms of Kellgren-Lawrence(K-L) classification, there were 15 cases of Grade Ⅲ and 27 cases of Grade Ⅳ;the disease duration ranged from 3 to 25 years, with an average of (15.5±7.5) years. The CRATKA group also included 42 patients, with 14 males and 28 females;the age ranged from 58 to 74 years old, with an average of (65.60±7.50) years old;the BMI was (24.50±2.70) kg·m-2; 20 cases were on the right side and 22 cases on the left side;regarding K-L classification, there were 11 cases of Grade Ⅲ and 31 cases of Grade Ⅳ;the disease duration ranged from 2 to 26 years, with an average of (16.5±8.8) years. Collect general data of all patients, including age, gender, height, weight, surgical site, K-L classification, incision length, and operation time. To evaluate prosthesis position, compare the frontal tibia component (FTC) angle, lateral femoral component (LFC) angle, lateral tibia component (LTC) angle, and frontal femoral component angle between the two groups of patients after surgery. Measure the deviation of the hip-knee-ankle (HKA) angle to assess lower limb alignment. Additionally, compare the following indicators between the two groups:Knee Society Score (KSS), Visual Analogue Scale (VAS) for pain, knee range of motion (ROM), hemoglobin (HB) level, hematocrit (HCT) level, complication rate, and in-hospital satisfaction.
RESULTS:
All patients successfully completed the surgery as scheduled, and all were followed up after the operation. The follow-up period ranged from 5 to 17 months with an average of (11.2±6.1) months. There were 4 cases of venous thrombosis in the HRATKA group and 3 cases in the CRATKA group;each group had 2 cases of wound exudation. No mechanical-related complications, pulmonary embolism, or other severe complications occurred. Comparison of the incision length and hospital stay between the HRATKA group and the CRATKA group showed no statistically significant difference (P>0.05). The operation time in the HRATKA group was (96.80±7.10) minutes, which was longer than that in the CRATKA group (90.10±8.80) minutes, and the difference was statistically significant (P<0.05). In the HRATKA group, the HKA angle was (178.93±1.11) degree, the FFC angle was (89.00±0.91)°, and the LFC angle was (7.31±2.17) degree;the corresponding values in the CRATKA group were (178.05±1.34)°, (87.88±1.74)°, and (10.60±2.84) degree respectively. The differences in these three indicators between the two groups were all statistically significant (P<0.05). However, there were no statistically significant differences in the FTC angle or LTC angle between the two groups (P>0.05). There was also no statistically significant difference in the total perioperative blood loss between the two groups (P>0.05). At 3 days after surgery, the VAS score for movement in the HRATKA group (5.95±1.45) points was higher than that in the CRATKA group (4.50±0.97) points, with a statistically significant difference (P<0.05);at 90 days after surgery, there was no statistically significant difference in the movement VAS score between the two groups (P>0.05). Additionally, no statistically significant differences were observed between the two groups in the KSS, ROM at 3 and 90 days after surgery, or satisfaction degree during hospitalization (all P>0.05).
CONCLUSION
The domestic HURWA robot demonstrates excellent performance in osteotomy efficiency and lower limb alignment recovery. The Smith & Nephew Cori robot has a significant advantage in soft tissue assessment and joint stability optimization. Both robotic systems offer high-quality surgical treatments that significantly improve short-term knee function.
Humans
;
Male
;
Female
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Aged
;
Middle Aged
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Osteoarthritis, Knee/surgery*
10.Preliminary efficacy observation of 3D printed functional spinal external fixation brace combined with McKenzie therapy in the treatment of lumbar disc herniation.
Ning-Xia WANG ; Ping CHEN ; Hai-Dong WANG ; Jing JI ; Fang-Hong NIAN ; Xin LIU ; Chong-Fei JIN ; Duo-Ming ZHAO ; Hao-Lin LI ; Wei-Gang CHENG ; Gui-Lin LAI ; Guo-Biao WU
China Journal of Orthopaedics and Traumatology 2025;38(10):1047-1054
OBJECTIVE:
To observe the clinical efficacy of 3D printing spinal external fixator combined with McKenzie therapy for patients with lumbar dics herniation (LDH).
METHODS:
Sixty patients with LDH between January 2022 and January 2023 were enrolled. Among them, 30 patients were given McKinsey training. According to different treatment methods, all patients were divided into McKenzie group and McKenzie + 3D printing group, 30 patients in each group. The McKenzie group provided McKenzie therapy. The McKenzie + 3D printing group were treated with 3D printing spinal external fixation brace on the basis of McKenzie therapy. Patients in both groups were between 25 and 60 years of age and had their first illness. In the McKenzie group, there were 19 males and 11 females, with an average age of (48.57±5.86) years old, and the disease duration was (7.03 ±2.39) months. The McKenzie + 3D printing group, there were 21 males and 9 females, with an average age of (48.80±5.92) years old, and the disease duration was(7.30±2.56) months. Pain was evaluated using the visual analogue scale (VAS), and lumbar spine function was assessed using the Oswestry disability index (ODI) and the Japanese Orthopaedic Association (JOA) score. VAS, ODI and JOA scores were compared between two groups before treatment and at 1, 3, 6, 9 and 12 months after treatment.
RESULTS:
All patients were followed up for 12 months. The VAS for the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(6.533±0.860), (5.133±1.008), (3.933±0.868), (2.900±0.759), (2.067±0.640), (1.433±0.504), respectively. In the McKenzie group, the corresponding scores were (6.467±0.860), (5.067±1.048), (4.600±0.968), (3.533±1.008), (2.567±0.728), (1.967±0.809), respectively. The ODI of the McKenzie group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were (41.033±6.810)%, (37.933±6.209)%, (35.467±6.962)%, (27.567±10.081)%, (20.800±7.531)%, (13.533±5.158)%, respectively. For the McKenzie combined with 3D printing group, the corresponding ODI were(38.033±5.605)%, (33.000±6.192)%, (28.767±7.045)%, (22.200±5.517)%, (17.700±4.836)%, (11.900±2.771)%, respectively. The JOA scores of the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(8.900±2.074), (13.133±2.330), (15.700±3.583), (20.400±3.480), (22.267±3.084), (24.833±2.640), respectively. In the McKenzie group, the corresponding scores were(9.200±2.091), (12.267±2.406), (15.333±3.198), (18.467±2.240), (20.133±2.751), (22.467±2.849), respectively. Before the initiation of treatment, no statistically significant differences were observed in the VAS, ODI, and JOA scores between two groups (P>0.05). At 3, 6, 9, and 12 months post-treatment, the VAS in the McKenzie combined with 3D printing group was significantly lower than that in the McKenzie group, and the difference was statistically significant (P<0.05). The comparison of ODI between two groups at 1, 3, 6, 9, and 12 months post-treatment revealed statistically significant differences (P<0.05). At 6, 9, and 12 months post-treatment, the JOA score in the McKenzie combined with 3D printing group was significantly higher than that in the McKenzie-only group, and the difference was statistically significant (P<0.05).
CONCLUSION
The combination of 3D printed functional spinal external fixation brace with McKenzie therapy can significantly improve and maintain lumbar function in patients with LDH.
Humans
;
Male
;
Female
;
Middle Aged
;
Printing, Three-Dimensional
;
Intervertebral Disc Displacement/surgery*
;
External Fixators
;
Lumbar Vertebrae/surgery*
;
Adult
;
Braces
;
Treatment Outcome

Result Analysis
Print
Save
E-mail