1.Preparation and application of conductive fiber coated with liquid metal.
Chengfeng LIU ; Jiabo TANG ; Ming LI ; Shihao ZHANG ; Yang ZOU ; Yonggang LYU
Journal of Biomedical Engineering 2025;42(4):724-732
Flexible conductive fibers have been widely applied in wearable flexible sensing. However, exposed wearable flexible sensors based on liquid metal (LM) are prone to abrasion and significant conductivity degradation. This study presented a high-sensitivity LM conductive fiber with integration of strain sensing, electrical heating, and thermochromic capabilities, which was fabricated by coating eutectic gallium-indium (EGaIn) onto spandex fibers modified with waterborne polyurethane (WPU), followed by thermal curing to form a protective polyurethane sheath. This fiber, designated as Spandex/WPU/EGaIn/Polyurethane (SWEP), exhibits a four-layer coaxial structure: spandex core, WPU modification layer, LM conductive layer, and polyurethane protective sheath. The SWEP fiber had a diameter of (458.3 ± 10.4) μm, linear density of (2.37 ± 0.15) g/m, and uniform EGaIn coating. The fiber had excellent conductivity with an average value of (3 716.9 ± 594.2) S/m. The strain sensing performance was particularly noteworthy. A 5 cm × 5 cm woven fabric was fabricated using polyester warp yarns and SWEP weft yarns. The fabric exhibited satisfactory moisture permeability [(536.06 ± 33.15) g/(m 2·h)] and maintained stable thermochromic performance after repeated heating cycles. This advanced conductive fiber development is expected to significantly promote LM applications in wearable electronics and smart textile systems.
Wearable Electronic Devices
;
Polyurethanes/chemistry*
;
Electric Conductivity
;
Gallium/chemistry*
;
Metals/chemistry*
2.Expert consensus on management of instrument separation in root canal therapy.
Yi FAN ; Yuan GAO ; Xiangzhu WANG ; Bing FAN ; Zhi CHEN ; Qing YU ; Ming XUE ; Xiaoyan WANG ; Zhengwei HUANG ; Deqin YANG ; Zhengmei LIN ; Yihuai PAN ; Jin ZHAO ; Jinhua YU ; Zhuo CHEN ; Sijing XIE ; He YUAN ; Kehua QUE ; Shuang PAN ; Xiaojing HUANG ; Jun LUO ; Xiuping MENG ; Jin ZHANG ; Yi DU ; Lei ZHANG ; Hong LI ; Wenxia CHEN ; Jiayuan WU ; Xin XU ; Jing ZOU ; Jiyao LI ; Dingming HUANG ; Lei CHENG ; Tiemei WANG ; Benxiang HOU ; Xuedong ZHOU
International Journal of Oral Science 2025;17(1):46-46
Instrument separation is a critical complication during root canal therapy, impacting treatment success and long-term tooth preservation. The etiology of instrument separation is multifactorial, involving the intricate anatomy of the root canal system, instrument-related factors, and instrumentation techniques. Instrument separation can hinder thorough cleaning, shaping, and obturation of the root canal, posing challenges to successful treatment outcomes. Although retrieval of separated instrument is often feasible, it carries risks including perforation, excessive removal of tooth structure and root fractures. Effective management of separated instruments requires a comprehensive understanding of the contributing factors, meticulous preoperative assessment, and precise evaluation of the retrieval difficulty. The application of appropriate retrieval techniques is essential to minimize complications and optimize clinical outcomes. The current manuscript provides a framework for understanding the causes, risk factors, and clinical management principles of instrument separation. By integrating effective strategies, endodontists can enhance decision-making, improve endodontic treatment success and ensure the preservation of natural dentition.
Humans
;
Root Canal Therapy/adverse effects*
;
Consensus
;
Root Canal Preparation/adverse effects*
3.Effect of securinine on proliferation and apoptosis of human colon cancer SW620 cells and its mechanism
Jing DENG ; Xuan WANG ; Changyu SHI ; Siqi YANG ; Qinling ZOU ; Ming JIN
Journal of Jilin University(Medicine Edition) 2025;51(2):307-316
Objective:To investigate the effect of securinine(SEC)on apoptosis of the human colon cancer cell line SW620,and to elucidate its possible mechanism.Methods:The nude mice with subcutaneously transplanted tumor were divided into control group(n=6),oxaliplatin(OXA)group(n=7),and SEC group(n=7).The volume and mass of subcutaneous tumors in the nude mice were measured in various groups,and the tumor inhibitory rates in various groups were calculated.The SW620 cells were treated with different doses(5-120 μmol·L-1)of SEC for 12,24,48,and 72 h,respectively.Cell counting kit-8(CCK-8)assay was used to assess the survival rates of cells in various groups,and the optimal doses of SEC were confirmed.The SW620 cells were divided into control group,20 μmol·L-1 SEC group,40 μmol·L-1SEC group,and 40 μmol·L-1OXA group.TUNEL staining method and flow cytometry were used to detect the apoptotic rates of cells in various groups.JC-1 staining was used to detect the mitochondrial membrane potentials of cells in various groups,and 2',7'-dichlorodi-hydrofluorescin diacetate(DCFH-DA)fluorescence staining and flow cytometry were used to measure the reactive oxygen species(ROS)levels in the cells in various groups.Western blotting method was used to detect the expression levels of cytochrome C,B-cell lymphoma-2(Bcl-2),Bcl-2-associated X protein(Bax),c-Jun N-terminal kinase(JNK),phosphorylated JNK(p-JNK),mitogen-activated protein kinase p38,phosphorylated p38(p-p38),extracellular signal-regulated kinase(ERK)and phosphorylated ERK(p-ERK)proteins in the cells in various groups.Results:Compared with control group,the volume and mass of subcutaneously transplanted tumors in the nude mice in SEC group were significantly decreased(P<0.05 or P<0.01 or P<0.001);the inhibitory rates of tumor in SEC group and OXA group were 20.42%and 6.50%.The CCK-8 assay results showed that compared with 0 μmol·L-1 SEC,when the SEC dose exceeded 20 μmol·L-1,the survival rates of SW620 cells were significantly decreased(P<0.001).The optimal condition for subsequent experiments was set as doses of 20 μmol·L-1SEC and 40 μmol·L-1SEC,and duration of 24 h.The TUNEL results showed that compared with control group,the apoptotic rates of cells in 20 and 40 μmol·L-1 SEC groups were significantly increased(P<0.05 or P<0.001).The results of flow cytometry showed that compared with control group,the apoptotic rate in 40 μmol·L-1SEC group was significantly increased(P<0.001).The JC-1 staining results showed that compared with control group,the mitochondrial membrane potentials of cells in 20 and 40 μmol·L-1 SEC groups were significantly decreased(P<0.001).Compared with control group,the levels of ROS detected by DCFH-DA fluorescence staining in the cells of 20 and 40 μmol·L-1 SEC groups and 40 μmol·L-1 OXA group were significantly increased(P<0.001),while the level of ROS detected by flow cytometry in 40 μmol·L-1SEC group was significantly increased(P<0.05).Compared with control group,the expression levels of Bcl-2 protein in the cells in 20 and 40 μmol·L-1 SEC groups and 40 μmol·L-1 OXA group were decreased(P<0.01),while the expression levels of cytochrome C and Bax proteins were increased(P<0.001).Compared with control group,the ratios of p-JNK/JNK,p-p38/p38 and p-ERK/ERK in 20 and 40 μmol·L-1 SEC groups were significantly increased(P<0.05 or P<0.01 or P<0.001).Conclusion:SEC can inhibit the proliferation of SW620 cells,increase the cellular ROS levels,reduce the mitochondrial membrane potential,and induce the mitochondrial apoptosis;its mechanism may be related to the regulation of the mitogen-activated protein kinase(MAPK)signaling pathway.
4.Shexiang Tongxin Dropping Pill Improves Stable Angina Patients with Phlegm-Heat and Blood-Stasis Syndrome: A Multicenter, Randomized, Double-Blind, Placebo-Controlled Trial.
Ying-Qiang ZHAO ; Yong-Fa XING ; Ke-Yong ZOU ; Wei-Dong JIANG ; Ting-Hai DU ; Bo CHEN ; Bao-Ping YANG ; Bai-Ming QU ; Li-Yue WANG ; Gui-Hong GONG ; Yan-Ling SUN ; Li-Qi WANG ; Gao-Feng ZHOU ; Yu-Gang DONG ; Min CHEN ; Xue-Juan ZHANG ; Tian-Lun YANG ; Min-Zhou ZHANG ; Ming-Jun ZHAO ; Yue DENG ; Chang-Jiang XIAO ; Lin WANG ; Bao-He WANG
Chinese journal of integrative medicine 2025;31(8):685-693
OBJECTIVE:
To evaluate the efficacy and safety of Shexiang Tongxin Dropping Pill (STDP) in treating stable angina patients with phlegm-heat and blood-stasis syndrome by exercise duration and metabolic equivalents.
METHODS:
This multicenter, randomized, double-blind, placebo-controlled clinical trial enrolled stable angina patients with phlegm-heat and blood-stasis syndrome from 22 hospitals. They were randomized 1:1 to STDP (35 mg/pill, 6 pills per day) or placebo for 56 days. The primary outcome was the exercise duration and metabolic equivalents (METs) assessed by the standard Bruce exercise treadmill test after 56 days of treatment. The secondary outcomes included the total angina symptom score, Chinese medicine (CM) symptom scores, Seattle Angina Questionnaire (SAQ) scores, changes in ST-T on electrocardiogram and adverse events (AEs).
RESULTS:
This trial enrolled 309 patients, including 155 and 154 in the STDP and placebo groups, respectively. STDP significantly prolonged exercise duration with an increase of 51.0 s, compared to a decrease of 12.0 s with placebo (change rate: -11.1% vs. 3.2%, P<0.01). The increase in METs was significantly greater in the STDP group than in the placebo group (change: -0.4 vs. 0.0, change rate: -5.0% vs. 0.0%, P<0.01). The improvement of total angina symptom scores (25.0% vs. 0.0%), CM symptom scores (38.7% vs. 11.8%), reduction of nitroglycerin consumption (100.0% vs. 11.3%), and all domains of SAQ, were significantly greater with STDP than placebo (all P<0.01). The changes in Q-T intervals at 28 and 56 days from baseline were similar between the two groups (both P>0.05). Twenty-five participants (16.3%) with STDP and 16 (10.5%) with placebo experienced AEs (P=0.131), with no serious AEs observed.
CONCLUSION
STDP could improve exercise tolerance in patients with stable angina and phlegm-heat and blood stasis syndrome, with a favorable safety profile. (Registration No. ChiCTR-IPR-15006020).
Humans
;
Double-Blind Method
;
Drugs, Chinese Herbal/adverse effects*
;
Male
;
Female
;
Middle Aged
;
Angina, Stable/physiopathology*
;
Aged
;
Syndrome
;
Treatment Outcome
;
Placebos
;
Tablets
5.Effective therapeutic targeting of tumor lineage plasticity in neuroendocrine prostate cancer by BRD4 inhibitors.
Xiong ZHANG ; Yatian YANG ; Hongye ZOU ; Yang YANG ; Xingling ZHENG ; Eva COREY ; Amina ZOUBEIDI ; Nicolas MITSIADES ; Ai-Ming YU ; Yuanpei LI ; Hong-Wu CHEN
Acta Pharmaceutica Sinica B 2025;15(3):1415-1429
Tumor lineage plasticity (LP) is an emerging hallmark of cancer progression. Through pharmacologically probing the function of epigenetic regulators in prostate cancer cells and organoids, we identified bromodomain protein BRD4 as a crucial player. Integrated ChIP-seq and RNA-seq analysis of tumors revealed, for the first time, that BRD4 directly activates hundreds of genes in the LP programs which include neurogenesis, axonogenesis, EMT and stem cells and key drivers such as POU3F2 (BRN2), ASCL1/2, NeuroD1, SOX2/9, RUNX1/2 and DLL3. Interestingly, BRD4 genome occupancy is reprogrammed by anti-AR drugs from facilitating AR function in CRPC cells to activating the LP programs and is facilitated by pioneer factor FOXA1. Significantly, we demonstrated that BRD4 inhibitor AZD5153, currently at clinical development, possesses potent activities in complete blockade of tumor growth of both de novo neuroendocrine prostate cancer (NEPC) and treatment-induced NEPC PDXs and that suppression of tumor expression of LP programs through reduction of local chromatin accessibility is the primary mechanism of action (MOA) by AZD5153. Together, our study revealed that BRD4 plays a fundamental role in direct activation of tumor LP programs and that its inhibitor AZD5153 is highly promising in effective treatment of the lethal forms of the diseases.
6.Development of transparent manikin and its application to surgical training on medical train
Ya-jun SONG ; Wen-gang HU ; Ming-hui YANG ; Sheng-qing LYU ; Chi-bing HUANG ; Ji-feng ZOU ; Yang LI ; Yun WANG ; Ji ZHENG
Chinese Medical Equipment Journal 2025;46(6):111-115
Objective To develop a novel type of transparent simulation manikin as a surgical training model to meet the surgical treatment demand on the medical train.Methods A transparent manikin was developed with the steps of basic data collection,motherboard design and manufacture and module production and assembly.Firstly,basic data collection was carried out with reference to standardized human anatomy and parameters.Secondly,some software such as UG NX7.5 was used to construct the motherboard of the manikin.Finally,module production and assembly were performed with the materials of acrylic,transparent rubber,silicone and hydrogel and the technology of silicone infusion.Results The transparent manikin developed had its anatomy structure close to that of the real body and high visuality for its internal and external components,which simulated a variety of war wounds and thus could be integrated with the surgical training scenarios on the medical train effectively.Conclusion The transparent manikin developed is characterized by high visuality,modularity and blood flow,and meets the demands for surgical training on the medical train.[Chinese Medical Equipment Journal,2025,46(6):111-115]
7.Comparison of arthroscopic Y-shaped suture suspension fixation versus open reduction and internal fixation for tibial insertion avulsion fractures of the posterior cruciate ligament
Zijiang YANG ; Tao HE ; Huai SHAO ; Ming ZOU ; Yun GU ; Min YU
Chinese Journal of Orthopaedic Trauma 2025;27(8):674-680
Objective:To compare the clinical outcomes of arthroscopic Y-shaped suture suspension fixation and those of open reduction and internal fixation in the treatment of tibial insertion avulsion fractures of the posterior cruciate ligament (PCL).Methods:A retrospective study was conducted to analyze the clinical data from the 23 patients with PCL tibial avulsion fracture who had been admitted to Department of Sports Medicine, The Affiliated Changsha Central Hospital, University of South China, from May 2018 to May 2024. There were 15 males and 8 females with an age of (39.0±15.6) years. By the Meyers-McKeever classification, there were 20 cases of type Ⅱ and 3 cases of type Ⅲ. All patients were divided into 2 groups based on their different surgical schemes: an arthroscopic group of 11 cases treated with Y-shaped suture suspension fixation under arthroscopy and an open group of 12 cases treated with open reduction and internal fixation. The surgical time, intraoperative blood loss, and visual analog scale (VAS) pain scores, Lysholm knee function scores, and International Knee Documentation Committee (IKDC) subjective scores at 1 month after surgery and the last follow-up were recorded and compared between the 2 groups.Results:There was no statistically significant difference in the preoperative general information between the 2 groups, indicating comparability ( P>0.05). The 23 patients were followed up for (13.7±3.8) months after surgery. None of the patients experienced complications like incision infection, neurovascular damage, nonunion or delayed union of fracture. In the arthroscopic group, the surgical time was (97.1±11.1) min, significantly shorter than that in the open group [(64.7±9.0) min], and the intraoperative blood loss (14.9±6.6) mL, significantly less than that in the open group [(29.4±13.2) mL] ( P<0.05). At 1 month after surgery, the VAS pain score, Lysholm knee function score, and IKDC subjective score in the arthroscopic group were, respectively, 3.0 (2.0, 3.0) points, (72.0±4.8) points, and (67.3±2.9) points, all significantly better than those in the open group [5.0 (4.0, 5.0) points, (66.9±4.0) points, and (63.1±2.4) points] ( P<0.05). There was no statistically significant difference in the VAS pain score, Lysholm knee function score, or IKDC subjective score at the last follow-up between the 2 groups ( P>0.05). Conclusions:Both arthroscopic Y-shaped suture suspension fixation and open reduction and internal fixation can achieve satisfactory treatment outcomes for PCL tibial avulsion fractures. The latter shows an advantage in shorter surgical time, but the former advantages in less bleeding volume and better early efficacy.
8.SCREENING AND EXPRESSION ANALYSIS OF GENES ASSOCIATED WITH INNATE IMMUNITY IN RESPONSE TO DENV2 INFECTION IN AEDES ALBOPICTUS
Yang ZHOU ; Man-Jin LI ; Jin CHENG ; Ya-Ming ZOU ; Ding ZHU ; Ce-Jie LAN ; Yuan SHEN
Acta Parasitologica et Medica Entomologica Sinica 2025;32(3):153-159,178
Objective Aedes albopictus is the primary vector of the dengue virus.Screening and the analysis of immune-related genes in DENV2-infected Ae.albopictus provides a scientific basis for further research on blocking the extrinsic incubation period of the dengue virus.Methods Through the approach of literature mining,thirty-three potential immune-related genes were screened from species such as Aedes aegypti and Anopheles gambiae,which have a close genetic relationship with Ae.albopictus.The protein—protein interaction(PPI)analysis is employed to explore the interaction relationship of the proteins encoded by genes.The alterations in mRNA expression levels of the relevant genes in DENV2-infected Ae.albopictus midgut were detected using the qRT-PCR method.Results The PPI results indicates that TLR and Spz of Ae.albopictus;Rel1,Rel2,DefC,Spz,PIWI,Ago2,DOME and HOP of Ae.aegypti;and Rel1,Rel2,CACT,STAT and DOME of An.gambiae exhibit PPI relationships.After Ae.albopictus was infected with DENV2,10 genes showed significant difference in expression.Ago3(7.39,P<0.05),DOMEa(1.63,P<0.01),DOMEb(21.29,P<0.001),and TLRb(1.61,P<0.05)were significantly up-regulated.Rel1(0.62,P<0.001),CACTl(0.65,P<0.001),Rel2a(0.65,P<0.01),Rel2b(0.24,P<0.001),GATAa(0.64,P<0.01)and DefC(0.28,P<0.05)were significantly down-regulated.Conclusions The concordance of Ae.albopictus with Ae.aegypti was higher than that with An.gambiae.DOMEb,Ago3,Rel2b and DefC,can serve as the preferred target genes for subsequent studies on DENV2 immune blockade.
9.Quality Evaluation of Fengshiding Capsules Based on National Drug Sampling and Testing
Lumei GUO ; Tao CHENG ; Donglan LIU ; Xingpeng LIU ; Ming YANG ; Fangfang SI ; Min ZOU ; Jialiang ZHU
Herald of Medicine 2025;44(9):1423-1430
Objective To systematically evaluate the quality of Fengshiding capsules,to analyze existing problems based on national drug sampling and testing,and to offer references and suggestions for improving quality control and regulatory supervision of this product.Methods A total of 136 batches of Fengshiding capsules were subjected to standard quality tests and exploratory analyses.HPLC was used to establish the content determination of Angelica dahurica,Cynanchum paniculatum,and Glycyrrhizae Radix,as well as the limit test for anabasine in the preparation.Additionally,an UPLC method was also employed to establish the characteristic chromatogram of Fengshiding capsules.A screening method for artificial pigments was developed,and UPLC-MS/MS was used to detect the illegal addition of chemical drugs in Fengshiding capsules.Results All 136 batches of samples passed inspection according to the current quality standards.However,based on exploratory study evaluations,the content determination results of Cynanchum paniculatum,Angelica dahurica,and Glycyrrhiza Radix were below the proposed limits.The limit test for anabasine did not exceed the proposed threshold.Furthermore,the characteristic chromatograms revealed missing peaks in several samples,and some batches contained artificial pigments and residues of acetaminophen.Conclusions The overall quality of Fengshiding capsules is rated as"average"based on national drug sampling and testing.To enhance product quality,it is recommended to improve quality standards,ensure the use of high-quality raw herbal materials,promote stronger internal oversight by manufacturers,and intensify regulatory supervision.
10.Development of transparent manikin and its application to surgical training on medical train
Ya-jun SONG ; Wen-gang HU ; Ming-hui YANG ; Sheng-qing LYU ; Chi-bing HUANG ; Ji-feng ZOU ; Yang LI ; Yun WANG ; Ji ZHENG
Chinese Medical Equipment Journal 2025;46(6):111-115
Objective To develop a novel type of transparent simulation manikin as a surgical training model to meet the surgical treatment demand on the medical train.Methods A transparent manikin was developed with the steps of basic data collection,motherboard design and manufacture and module production and assembly.Firstly,basic data collection was carried out with reference to standardized human anatomy and parameters.Secondly,some software such as UG NX7.5 was used to construct the motherboard of the manikin.Finally,module production and assembly were performed with the materials of acrylic,transparent rubber,silicone and hydrogel and the technology of silicone infusion.Results The transparent manikin developed had its anatomy structure close to that of the real body and high visuality for its internal and external components,which simulated a variety of war wounds and thus could be integrated with the surgical training scenarios on the medical train effectively.Conclusion The transparent manikin developed is characterized by high visuality,modularity and blood flow,and meets the demands for surgical training on the medical train.[Chinese Medical Equipment Journal,2025,46(6):111-115]

Result Analysis
Print
Save
E-mail