1.Effect of Anti-reflux Mucosal Ablation on Esophageal Motility in Patients With Gastroesophageal Reflux Disease: A Study Based on High-resolution Impedance Manometry
Chien-Chuan CHEN ; Chu-Kuang CHOU ; Ming-Ching YUAN ; Kun-Feng TSAI ; Jia-Feng WU ; Wei-Chi LIAO ; Han-Mo CHIU ; Hsiu-Po WANG ; Ming-Shiang WU ; Ping-Huei TSENG
Journal of Neurogastroenterology and Motility 2025;31(1):75-85
Background/Aims:
Anti-reflux mucosal ablation (ARMA) is a promising endoscopic intervention for proton pump inhibitor (PPI)-dependent gastroesophageal reflux disease (GERD). However, the effect of ARMA on esophageal motility remains unclear.
Methods:
Twenty patients with PPI-dependent GERD receiving ARMA were prospectively enrolled. Comprehensive self-report symptom questionnaires, endoscopy, 24-hour impedance-pH monitoring, and high-resolution impedance manometry were performed and analyzed before and 3 months after ARMA.
Results:
All ARMA procedures were performed successfully. Symptom scores, including GerdQ (11.16 ± 2.67 to 9.11 ± 2.64, P = 0.026) and reflux symptom index (11.63 ± 5.62 to 6.11 ± 3.86, P = 0.001), improved significantly, while 13 patients (65%) reported discontinuation of PPI. Total acid exposure time (5.84 ± 4.63% to 2.83 ± 3.41%, P = 0.024) and number of reflux episodes (73.05 ± 19.34 to 37.55 ± 22.71, P < 0.001) decreased significantly after ARMA. Improved esophagogastric junction (EGJ) barrier function, including increased lower esophageal sphincter resting pressure (13.89 ± 10.78 mmHg to 21.68 ± 11.5 mmHg, P = 0.034), 4-second integrated relaxation pressure (5.75 ± 6.42 mmHg to 9.99 ± 5.89 mmHg, P = 0.020), and EGJ-contractile integral(16.42 ± 16.93 mmHg · cm to 31.95 ± 21.25 mmHg · cm, P = 0.016), were observed. Esophageal body contractility also increased significantly (distal contractile integral, 966.85 ± 845.84 mmHg · s · cm to 1198.8 ± 811.74 mmHg · s · cm, P = 0.023). Patients with symptom improvement had better pre-AMRA esophageal body contractility.
Conclusions
ARMA effectively improves symptoms and reflux burden, EGJ barrier function, and esophageal body contractility in patients with PPIdependent GERD during short-term evaluation. Longer follow-up to clarify the sustainability of ARMA is needed.
2.Design, synthesis and evaluation of oxadiazoles as novel XO inhibitors
Hong-zhan WANG ; Ya-jun YANG ; Ying YANG ; Fei YE ; Jin-ying TIAN ; Chuan-ming ZHANG ; Zhi-yan XIAO
Acta Pharmaceutica Sinica 2025;60(1):164-171
Xanthine oxidase (XO) is an important therapeutic target for the treatment of hyperuricemia and gout. Based on the previously identified potent XO inhibitor
3.Effect of Anti-reflux Mucosal Ablation on Esophageal Motility in Patients With Gastroesophageal Reflux Disease: A Study Based on High-resolution Impedance Manometry
Chien-Chuan CHEN ; Chu-Kuang CHOU ; Ming-Ching YUAN ; Kun-Feng TSAI ; Jia-Feng WU ; Wei-Chi LIAO ; Han-Mo CHIU ; Hsiu-Po WANG ; Ming-Shiang WU ; Ping-Huei TSENG
Journal of Neurogastroenterology and Motility 2025;31(1):75-85
Background/Aims:
Anti-reflux mucosal ablation (ARMA) is a promising endoscopic intervention for proton pump inhibitor (PPI)-dependent gastroesophageal reflux disease (GERD). However, the effect of ARMA on esophageal motility remains unclear.
Methods:
Twenty patients with PPI-dependent GERD receiving ARMA were prospectively enrolled. Comprehensive self-report symptom questionnaires, endoscopy, 24-hour impedance-pH monitoring, and high-resolution impedance manometry were performed and analyzed before and 3 months after ARMA.
Results:
All ARMA procedures were performed successfully. Symptom scores, including GerdQ (11.16 ± 2.67 to 9.11 ± 2.64, P = 0.026) and reflux symptom index (11.63 ± 5.62 to 6.11 ± 3.86, P = 0.001), improved significantly, while 13 patients (65%) reported discontinuation of PPI. Total acid exposure time (5.84 ± 4.63% to 2.83 ± 3.41%, P = 0.024) and number of reflux episodes (73.05 ± 19.34 to 37.55 ± 22.71, P < 0.001) decreased significantly after ARMA. Improved esophagogastric junction (EGJ) barrier function, including increased lower esophageal sphincter resting pressure (13.89 ± 10.78 mmHg to 21.68 ± 11.5 mmHg, P = 0.034), 4-second integrated relaxation pressure (5.75 ± 6.42 mmHg to 9.99 ± 5.89 mmHg, P = 0.020), and EGJ-contractile integral(16.42 ± 16.93 mmHg · cm to 31.95 ± 21.25 mmHg · cm, P = 0.016), were observed. Esophageal body contractility also increased significantly (distal contractile integral, 966.85 ± 845.84 mmHg · s · cm to 1198.8 ± 811.74 mmHg · s · cm, P = 0.023). Patients with symptom improvement had better pre-AMRA esophageal body contractility.
Conclusions
ARMA effectively improves symptoms and reflux burden, EGJ barrier function, and esophageal body contractility in patients with PPIdependent GERD during short-term evaluation. Longer follow-up to clarify the sustainability of ARMA is needed.
4.Effect of Anti-reflux Mucosal Ablation on Esophageal Motility in Patients With Gastroesophageal Reflux Disease: A Study Based on High-resolution Impedance Manometry
Chien-Chuan CHEN ; Chu-Kuang CHOU ; Ming-Ching YUAN ; Kun-Feng TSAI ; Jia-Feng WU ; Wei-Chi LIAO ; Han-Mo CHIU ; Hsiu-Po WANG ; Ming-Shiang WU ; Ping-Huei TSENG
Journal of Neurogastroenterology and Motility 2025;31(1):75-85
Background/Aims:
Anti-reflux mucosal ablation (ARMA) is a promising endoscopic intervention for proton pump inhibitor (PPI)-dependent gastroesophageal reflux disease (GERD). However, the effect of ARMA on esophageal motility remains unclear.
Methods:
Twenty patients with PPI-dependent GERD receiving ARMA were prospectively enrolled. Comprehensive self-report symptom questionnaires, endoscopy, 24-hour impedance-pH monitoring, and high-resolution impedance manometry were performed and analyzed before and 3 months after ARMA.
Results:
All ARMA procedures were performed successfully. Symptom scores, including GerdQ (11.16 ± 2.67 to 9.11 ± 2.64, P = 0.026) and reflux symptom index (11.63 ± 5.62 to 6.11 ± 3.86, P = 0.001), improved significantly, while 13 patients (65%) reported discontinuation of PPI. Total acid exposure time (5.84 ± 4.63% to 2.83 ± 3.41%, P = 0.024) and number of reflux episodes (73.05 ± 19.34 to 37.55 ± 22.71, P < 0.001) decreased significantly after ARMA. Improved esophagogastric junction (EGJ) barrier function, including increased lower esophageal sphincter resting pressure (13.89 ± 10.78 mmHg to 21.68 ± 11.5 mmHg, P = 0.034), 4-second integrated relaxation pressure (5.75 ± 6.42 mmHg to 9.99 ± 5.89 mmHg, P = 0.020), and EGJ-contractile integral(16.42 ± 16.93 mmHg · cm to 31.95 ± 21.25 mmHg · cm, P = 0.016), were observed. Esophageal body contractility also increased significantly (distal contractile integral, 966.85 ± 845.84 mmHg · s · cm to 1198.8 ± 811.74 mmHg · s · cm, P = 0.023). Patients with symptom improvement had better pre-AMRA esophageal body contractility.
Conclusions
ARMA effectively improves symptoms and reflux burden, EGJ barrier function, and esophageal body contractility in patients with PPIdependent GERD during short-term evaluation. Longer follow-up to clarify the sustainability of ARMA is needed.
5.Advances in clinical studies of ictal asystole in epileptic seizure
Ming WEN ; Chuan LIN ; Zhanhui FENG ; Weibo WANG
Chinese Journal of Neurology 2024;57(12):1377-1381
Ictal asystole in epileptic seizure (IA) is one of the severe complications of epilepsy, which is associated with falls and traumatic injuries related to seizures. Epileptic patients with IA may require adjustment to their treatment, including antiseizure medications adjustment, evaluation for epilepsy surgery and consideration of cardiac pacemaker implantation. However, there is no consensus on treatment options for these patients. This review focuses on the mechanisms, clinical features, auxiliary examinations and the outcomes of different treatments in the IA patients. Machine learning has some application values in analyzing the long-term video electroencephalogram (EEG) results of such patients and exploring the correlated characteristics between EEG and heart rate variability, which may provide a new perspective for the research.
6.Maintenance and improvement program for WYD2000 field surgical lamp
Ming-Ming ZHU ; Ji-Su CAO ; Ze-Rui ZHANG ; Jiang-Hui HAO ; Rui-Zhe WANG ; Feng ZHOU ; Lu-Chuan XUN
Chinese Medical Equipment Journal 2024;45(4):116-118
The steps for installation and withdrawal of WYD2000 field surgical lamp were introduced.The failures and causes of broken cross-arm connector of WYD2000 field surgical lamp were analyzed.The problems of WYD2000 field surgical lamp in vulnerability to breaking and difficulty in maintenance were solved by designing and manufacturing a special maintenance tool and optimizing the materials and fixing mode of cross-arm connection.References were provided for main-tenance and improvement of WYD2000 field surgical lamp.[Chinese Medical Equipment Journal,2024,45(4):116-118]
7.Development and Application of a Micro-device for Rapid Detection of Ammonia Nitrogen in Environmental Water
Peng WANG ; Yong TIAN ; Chuan-Yu LIU ; Wei-Liang WANG ; Xu-Wei CHEN ; Yan-Feng ZHANG ; Ming-Li CHEN ; Jian-Hua WANG
Chinese Journal of Analytical Chemistry 2024;52(2):178-186,中插1-中插3
The analysis of ammonia nitrogen in real water samples is challenging due to matrix interferences and difficulties for rapid on-site analysis.On the basis of the standard method,i.e.water quality-determination of ammonia nitrogen-salicylic acid spectrophotometry(HJ 536-2009),a simple device for online detecting ammonia nitrogen was developed using a sequential injection analysis(SIA)system in this work.The ammonia nitrogen transformation system,color reaction system,and detection system were built in compatible with the SIA system,respectively.In particular,the detection system was assembled by employing light-emitting diode as the light source,photodiode as the detector,and polyvinylchloride tube as the cuvette,thus significantly reducing the volume,energy consumption and fabricating cost of the detection system.As a result,the accurate analysis of ammonia nitrogen in complex water samples was achieved.A quantitative detection of ammonia nitrogen in water sample was obtained in 12 min,along with linear range extending to 1000 μmol/L,precisions(Relative standard deviation,RSD)of 4.3%(C=10 μmol/L,n=7)and 4.2%(C=500 μmol/L,n=7),and limit of detection(LOD)of 0.65 μmol/L(S/N=3,n=7).The results of interfering experiments showed that the detection of ammonia nitrogen by the developed device was not interfered by the common coexisting ions and components,therefore the environmental water could be directly analyzed,such as reservoir water,domestic sewage,sea water and leachate of waste landfill.The analytical results were consistent with those obtained by the environmental protection standard method(Water quality determination of ammonia nitrogen-salicylic acid spectrophotometry,HJ 536-2009).In addition,the spiking recoveries were in the range of 92.3%-98.1%,further confirming the accuracy and practicality of the developed device.
8.Compliance and correctness of hand hygiene of health care workers in intensive care units of a tertiary first-class hospital
Ming-Jun ZOU ; Li TAN ; Min XU ; Chuan XU ; Kun TAN ; Xiao WANG
Chinese Journal of Infection Control 2024;23(3):298-304
Objective To study the compliance and correctness of hand hygiene(HH)of staff in intensive care units(ICUs)of a tertiary first-class hospital,and provide theoretical basis for HH intervention.Methods In April 2023,staff in 17 ICUs of this hospital were performed on-site survey by infection control staff,and monitoring forms about HH compliance and correctness were filled out.Results A total of 874 HH opportunities were ob-served with the concealed observation method,501 HH opportunities were implemented,the compliance rate was 57.32%,273 HH opportunities were correctly implemented,with an correct rate of 54.49%.The compliance and correct rate of HH among staff in different ICUs varied significantly.Compliance and correct rates of HH among staff with different jobs were statistically different:HH compliance rate of cleaners(31.97%)was lower than that of nurses(63.83%),doctors(58.77%)and other personnel(58.14%);HH correct rate of cleaners(30.77%)was lower than that of nurses(58.17%).The causes for not implementing HH among staff with different jobs and at different HH opportunities were statistically different:the rate of not implementing any HH measures after con-tact with patients(84.75%)was higher than before contact with patients(41.27%),before clean and sterile ma-nipulation(30.00%),as well as after contact with blood and body fluid(45.45%).The rate of not implementing any HH measures after contact with the patient's surrounding environment(66.67%)was higher than before con-tact with patient as well as before clean and sterile manipulation.The rates of incomplete HH steps and insufficient HH time among staff with different jobs were statistically different:The rates of incomplete HH steps of other per-sonnel(82.35%)was higher than that of doctors(52.63%).The rates of insufficient HH time of doctors(82.46%)and nurses(78.18%)were higher than that of cleaners(51.85%).Conclusion The implementation of HH among different occupational groups and at different HH implementation opportunities in ICU is significantly different,which should be intervened based on their characteristics.
9.Synthesis and Characterization of Carbon Dots and Its Applications in Latent Fingerprint Development
Wen-Zhuo FAN ; Zhuo-Hong YU ; Meng WANG ; Jie LI ; Yi-Ze DU ; Ming LI ; Chuan-Jun YUAN
Chinese Journal of Analytical Chemistry 2024;52(4):492-503
Fluorescent carbon dots(CDs)were synthesized via a solvothermal method with citric acid and urea as raw materials,and ethylene glycol as reaction solvent.The micromorphology,crystal structure,elemental composition,surface functional group,and optical property of as-synthesized CDs were characterized.The excitation-dependent fluorescence property of CDs was investigated,and the effects of synthesis conditions including reaction temperature,reaction time and raw materials on excitation and emission wavelengths of the CDs were also discussed.Then,a series of CDs-based fluorescent composites were prepared by combining CDs with starch,nano-silica,montmorillonite,kaoline,kieselguhr and magnesium oxide,respectively.Finally,the CDs-starch composites were used for latent fingerprint development on smooth substrates,and the qualitative as well as quantitative evaluation of the contrast,sensitivity and selectivity in fingerprint development were also made.Enhanced development of latent fingerprints was thus achieved by the aid of the excitation-dependent fluorescence property of CDs-starch composite combined with the optical filtering technique,which could decrease the background noise interference to a great extent.Experimental results showed that,the contrast between fingerprint(developing signal)and substrate(background noise)was obvious,exhibiting a strong contrast;the minutiae of papillary ridges were clear,indicating a high sensitivity;the adsorption between CDs-starch composites and fingerprint residues was specific,showing a good selectivity.
10.Quantitative Evaluation of Latent Fingerprints Developed by Fluorescent Methods Based on Python
Zhuo-Hong YU ; Zhi-Ze XU ; Meng WANG ; Wen-Zhuo FAN ; Jie LI ; Ming LI ; Chuan-Jun YUAN
Chinese Journal of Analytical Chemistry 2024;52(7):964-974,中插1-中插12
A serious of rare earth luminescent micro/nano-materials with various properties were synthesized via chemical method for fluorescent development of latent fingerprints(LFPs).Three evaluation indexes namely contrast,sensitivity and selectivity were introduced to evaluate the effects of LFP development.Quantitative formulas for calculating the contrast,sensitivity and selectivity were further put forward,and a quality evaluation system based on Python was thus established.In addition,the objective evaluation value was finally confirmed to be consistent with the subjective visual judgment.The reproducibility of this evaluation method was finally confirmed.The effects of luminescence intensity and color of developing materials on the contrast,particle size of developing materials on the sensitivity,and micromorphology and surface property of developing materials on the selectivity were discussed in detail.Five effective ways were also proposed to promote the quality of LFP development,such as increasing the luminescence intensity,tuning the luminescence color,decreasing the particle size,adjusting the micromorphology,and modifying the surface property.This quality evaluation system based on Python could evaluate the effects of LFP development objectively,accurately and comprehensively,exhibiting easy operability,high efficiency,sensitive response,accurate and reliable results,and wide applicability,which would provide beneficial references for the reasonable selection of LFP development methods as well as objective evaluation of evidence value.

Result Analysis
Print
Save
E-mail