1.Toxicokinetics of Chlorfenapyr and Its Metabolites in Rats
Wen-Yan LI ; Jin-Feng ZHAO ; Wei-Chen LIU ; Shi-Jing LÜ ; Jia-Xin ZHANG ; Xu-Dong ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Chao ZHANG
Journal of Forensic Medicine 2025;41(4):380-386
Objective To establish a chromatography-tandem mass spectrometry method for detecting chlorfenapyr and its metabolite tralopyril in blood,and to investigate the toxicokinetics in rats.Methods Chlorfenapyr(8 mg/kg)was administered orally to rats,and blood samples were collected from rats'canthus vein at 5 min,15 min,30 min,1 h,3 h,6 h,12 h,24 h and 48 h after administration.The blood samples were extracted using 100 μL of 5%formic acid solution and 400 μL of acetonitrile.Chlorfena-pyr was qualitatively and quantitatively detected by triple quadrupole gas chromatography-tandem mass spectrometry(GC-MS/MS)and tralopyril was detected by triple quadrupole liquid chromatography-tandem mass spectrometry(LC-MS/MS).The DAS 3.0 software was used to fit the toxicokinetic equa-tions and calculate the toxicokinetic parameters.Results Chlorfenapyr was detectable from 5 min to 24 h with a peak time of 1 h.Tralopyril was detectable from 15 min to 48 h with a peak time of 3 h.The toxicokinetic process of chlorfenapyr in rat blood conformed to a first-order absorption one-compartment open model,with the toxicokinetic equation described as C=e-0.265t-e-0.175t.Tralopyril con-formed to the first-order absorption three-compartment model,and the toxicokinetic equation was C=47 361.069e-2.209t-35 404.962e-1.486t+11 956.363e-0.512t.In the equations,C stands for the concentration of the target substance in the blood,e is the natural constant(≈2.718 28),and t stands for time.Conclu-sion This study optimized the detection method for chlorfenapyr and its metabolite tralopyril in blood.The toxicokinetic equations and parameters of chlorfenapyr and tralopyril can provide a reference for the estimation of oral intake time of chlorfenapyr.
2.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
3.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
4.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
5.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
6.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
7.Biomechanical study and clinical application of two osteotomy guide methods in media open wedge high tibial osteotomy operation.
Chao QI ; Xiao-Ming LI ; Dong-Hui GUO ; Qiu-Ling SHI ; Yun-Chao ZHAO ; Jun DONG ; Zheng-Xin MENG ; Xing-Yue WANG
China Journal of Orthopaedics and Traumatology 2025;38(7):698-704
OBJECTIVE:
To explore the effectiveness and feasibility of two osteotomy guides in medial open wedge high tibial osteotomy (MOWHTO).
METHODS:
Clinical data of 103 patients who underwent routine MOWHTO surgery between January 2020 and December 2022 were collected for retrospective analysis. The patients were divided into two groups based on the method of osteotomy guide plate. The control group of 51 patients received traditional osteotomy guide plate technique, including 17 males and 34 females, aged from 48 to 68 years old with an average of(57.93±4.82) years old, with a disease duration ranged from 1 to 8 years with an average of (4.89±1.49) years. The observation group of 52 patients received personalized osteotomy guide plate technique, including 23 males and 29 females, aged from 48 to 69 with an average of (58.22±5.10) years, with a disease duration ranged from 1 to 9 years with an average of(5.10±1.55) years. The perioperative indicators, complications, and knee joint recovery rate were statistically analyzed for both groups, as well as the preoperative and postoperative coagulation function, fibrinogen (FIB), D-dimer (D-D), gait parameters (step frequency, step length, step speed), biomechanical indicators, weight bearing line (WBL), medial proximal tibial angle (MPTA), joint line conergence angle (JLCA), and anterior cruciate ligament (ACL) function (body width, tibial anterior displacement).
RESULTS:
All patients were followed up for 6 months. The intraoperative blood loss, operation time, and number of fluoroscopic views in the observation group were (358.58±93.76) ml, (84.42±8.17) min, and (2.00±0.44) times, respectively, which were all less than those in the control group (465.55±105.38) ml, (96.53±10.51) min, and (6.31±0.58) times (P<0.05). Three days after surgery, the FIB and D-D levels in the observation group were (4.21±0.48) g·L-1 and (204.47±35.59) μg·L-1, respectively, which were both lower than those in the control group (5.56±0.57) g·L-1 and (311.12±42.23) μg·L-1 (P<0.05). Three months after surgery, the step frequency, step length, and step speed in the observation group were (1.89±0.23) steps·s-1, (0.57±0.15) m, and (0.99±0.11) m·s-1, respectively, which were all higher than those in the control group (1.80±0.18) steps·s-1, (0.50±0.14) m, and (0.95±0.09) m·s-1 (P<0.05). Three months after surgery, the WBL and MPTA in the observation group were (45.53±4.41)% and (87.03±8.15)°, respectively, which were both higher than those in the control group (38.38±4.36)% and (83.68±8.50)°, and the JLCA was (2.36±0.24)°, which was lower than that in the control group (2.61±0.33)° (P<0.05). The ACL body width during internal fixation removal was (5.60±0.51) mm, which was greater than that in the control group (5.08±0.56) mm, and the tibial migration was (5.70±0.42) mm, which was less than that in the control group (6.33±0.48) mm (P<0.05). There was no significant difference in the incidence of complications between the two groups (P>0.05). Six months after surgery, there was no significant difference in the recovery rate of knee joint between the two groups (P>0.05).
CONCLUSION
The application of personalized osteotomy guide technique in MOWHTO can help improve knee biomechanics and ACL function, and has less effect on coagulation function and no increase in complications.
Humans
;
Male
;
Female
;
Osteotomy/methods*
;
Middle Aged
;
Tibia/physiopathology*
;
Aged
;
Biomechanical Phenomena
;
Retrospective Studies
;
Osteoarthritis, Knee/physiopathology*
8.Safety and efficacy of human umbilical cord-derived mesenchymal stem cells in COVID-19 patients: A real-world observation.
Siyu WANG ; Tao YANG ; Tiantian LI ; Lei SHI ; Ruonan XU ; Chao ZHANG ; Zerui WANG ; Ziying ZHANG ; Ming SHI ; Zhe XU ; Fu-Sheng WANG
Chinese Medical Journal 2025;138(22):2984-2992
BACKGROUND:
The effects of human umbilical cord-derived mesenchymal stem cell (UC-MSC) treatment on coronavirus disease 2019 (COVID-19) patients have been preliminarily characterized. However, real-world data on the safety and efficacy of intravenous transfusions of MSCs in hospitalized COVID-19 patients at the convalescent stage remain to be reported.
METHODS:
This was a single-arm, multicenter, real-word study in which a contemporaneous external control was included as the control group. Besides, severe and critical COVID-19 patients were considered together as the severe group, given the small number of critical patients. For a total of 110 patients, 21 moderate patients and 31 severe patients were enrolled in the MSC treatment group, while 26 moderate patients and 32 severe patients were enrolled in the control group. All patients received standard treatment. The MSC treatment patients additionally received intravenous infusions of MSCs at a dose of 4 × 10 7 cells on days 0, 3, and 6, respectively. The clinical outcomes, including adverse events (AEs), lung lesion proportion on chest computed tomography, pulmonary function, 6-min walking distance (6-MWD), clinical symptoms, and laboratory parameters, were measured on days 28, 90, 180, 270, and 360 during the follow-up visits.
RESULTS:
In patients with moderate COVID-19, MSC treatment improved pulmonary function parameters, including forced expiratory volume in the first second (FEV1) and maximum forced vital capacity (VCmax) on days 28 (FEV1, 2.75 [2.35, 3.23] vs . 2.11 [1.96, 2.35], P = 0.008; VCmax, 2.92 [2.55, 3.60] vs . 2.47 [2.18, 2.68], P = 0.041), 90 (FEV1, 2.93 [2.63, 3.27] vs . 2.38 [2.24, 2.63], P = 0.017; VCmax, 3.52 [3.02, 3.80] vs . 2.59 [2.45, 3.15], P = 0.017), and 360 (FEV1, 2.91 [2.75, 3.18] vs . 2.30 [2.16, 2.70], P = 0.019; VCmax,3.61 [3.35, 3.97] vs . 2.69 [2.56, 3.23], P = 0.036) compared with the controls. In addition, in severe patients, MSC treatment notably reduced the proportion of ground-glass lesions in the whole lung volume on day 90 ( P = 0.045) compared with the controls. No difference in the incidence of AEs was observed between the two groups. Similarly, no significant differences were found in the 6-MWD, D-dimer levels, or interleukin-6 concentrations between the MSC and control groups.
CONCLUSIONS:
Our results demonstrate the safety and potential of MSC treatment for improved lung lesions and pulmonary function in convalescent COVID-19 patients. However, comprehensive and long-term studies are required to confirm the efficacy of MSC treatment.
TRIAL REGISTRATION
Chinese Clinical Trial Registry, ChiCTR2000031430.
Humans
;
COVID-19/therapy*
;
Female
;
Male
;
Mesenchymal Stem Cell Transplantation/adverse effects*
;
Middle Aged
;
Adult
;
Umbilical Cord/cytology*
;
Mesenchymal Stem Cells/cytology*
;
SARS-CoV-2
;
Aged
;
Treatment Outcome
9.Novel Structural Features of Isoflavone Synthase from Medicago truncatula Shed Light on Its Unique Enzymatic Mechanism
Chao SHI ; Zhao-Yang YE ; Fei XU ; Xiang-Ning DU ; Zhang-Xin CHEN ; Ming-Yue GU ; Jie DENG ; Wei WANG ; Liang-Yu LIU ; Mei-Ying WANG ; Xiao-Dong SU ; He-Li LIU ; Ming-Ying SHANG ; Li-Xin HUANG ; Zhen-Zhan CHANG
Chinese Journal of Biochemistry and Molecular Biology 2025;41(8):1204-1213,中插1-中插6
Isoflavones which mainly distributed in leguminous plants have plenty of health benefits.Isoflavone synthase(IFS)is a membrane-associated cytochrome P450 enzyme(CYP450)which carries out the unique aryl-ring migration and hydroxylation.So far,few crystal structures of plant P450s have been obtained.We determined the crystal structure of IFS from Medicago truncatula at 1.9 ? by MAD method using a selenomethionine substituted crystal and conducted molecular docking and mutagenesis study.The structure of IFS complexed with imidazole exhibits the helix Ⅰa-loop-helix Ⅰβ motif which cor-responds to helix Ⅰ of other P450s.Compared with structures of common P450s,IFS/imidazole structure contains an extra domain,i.e.,the γ-domain.The structure reveals a homodimer in which the γ-domain of one molecule interacts with the β-domain of another.The plane of heme group makes an angle of ap-proximately 40° with the helix Ⅰa-loop-helix Ⅰβ motif.Molecular docking combined with mutagenesis study suggested that Trp-128 and Asp-300 might play important roles in substrate binding and recogni-tion.Phe-301,Ser-303 and Gly-305 from the helix Ⅰa-loop-helix Ⅰβ motif may play important roles in the aryl-ring migration.These novel structural features reveal insights into the unique reaction mechanism of IFS and provide a basis for engineering IFS in leguminous crops for health purpose.
10.Administrative burden among primary healthcare professionals and its impact mechanism on job burnout:An exploratory sequential mixed-methods study
Shi-chao ZHAO ; Ming-ze XIN ; Zi-qian TANG ; Ya-fang DONG ; He-xi LI ; Hui-fen MA ; Tao WANG
Chinese Journal of Health Policy 2025;18(9):31-38
Objective:To examine the manifestations and causes of administrative burden among primary healthcare professionals,and to explore its impact on job burnout through the mediating role of role conflict,providing theoretical and empirical support for governance-level burden-reduction strategies.Methods:An exploratory sequential mixed-methods design was employed,focusing on primary healthcare professionals in Shandong Province.In the first phase,in-depth interviews were conducted with 175 participants;in the second phase,a questionnaire survey of 1,096 participants and follow-up interviews with 107 participants were carried out.Results:The proportions of respondents who reported"heavy"or"very heavy"burdens were 62.7%for inspection,54.8%for documentation,51.8%for reporting,and 24.4%for meetings.Structural equation modeling showed that administrative burden had a direct effect on job burnout(0.150)and an indirect effect through role conflict(0.093).Qualitative findings further indicated that administrative burden largely stemmed from public health traceability requirements and medical insurance policies,and operated through both resource-based and value-based conflicts.Conclusions:Primary healthcare professionals face considerable administrative burdens,which may heighten job burnout through role conflict.Governance reforms should optimize inspection and assessment,streamline data reporting,refine record-keeping,and promote collaborative governance to break the chain of institutional pressure leading to burnout.

Result Analysis
Print
Save
E-mail