1.Burnout among COVID-19 hospital-based contact tracers in Singapore: results of a mixed-method, cross-sectional multicentre study.
Ian Matthias NG ; Tzu-Jung WONG ; Yong YANG ; Indumathi VENKATACHALAM ; Jean Xiang Ying SIM ; Liang En WEE ; Tau Ming LIEW ; Evelyn BOON ; Tong Yong NG ; Hwi Kwang HAN ; Diana Yuen Lan TAN
Singapore medical journal 2025;66(12):651-658
INTRODUCTION:
During the coronavirus disease 2019 (COVID-19) pandemic, contact tracers were under immense pressure to deliver effective and timely contact tracing, raising concerns of higher susceptibility to burnout. Our study aimed to determine burnout prevalence among hospital-based contact tracers and associated risk factors, so that interventions to reduce burnout risk could be formulated.
METHODS:
One hundred and ninety-six active contact tracers across three hospitals within a healthcare cluster were invited to complete an anonymous online survey. To identify burntout, data such as demographics, work-related variables and contact tracing-related variables were collected using the Copenhagen Burnout Inventory. Associated factors were identified using multivariate statistics. Open-ended questions were included to understand the challenges and potential improvements through qualitative analysis.
RESULTS:
A total of 126 participants completed the survey, giving a completion rate of 64%, and almost half of these participants (42.9%) reported burnout. Protective factors included being on work-from-home arrangements (adjusted odds ratio [OR] 0.22, 95% confidence interval [CI] 0.08-0.56), perception of being well supported by their institution (adjusted OR 0.25, 95% CI 0.08-0.80) and being married (adjusted OR 0.28, 95% CI 0.12-0.64). Risk factors included having an administrative role pre-COVID-19 (adjusted OR 3.62, 95% CI 1.33-9.83). Work-related burnout was related to being activated for more than 1 day in the preceding week (unadjusted OR 3.25, 95% CI 1.33-7.94) and multiple activations in a day (unadjusted OR 3.54, 95% CI 1.44-4.41). Biggest challenges identified by participants were language barrier (62.7%), followed by workflow-related issues (42.1%).
CONCLUSION
Our study demonstrated burnout and other challenges faced by a team of mostly hospital-based administrative staff redeployed on a part-time basis to ensure timely contact tracing. To mitigate burnout, we recommend choosing staff on work-from-home arrangements and ensuring adequate manpower and rostering arrangements.
Humans
;
COVID-19/epidemiology*
;
Burnout, Professional/epidemiology*
;
Singapore/epidemiology*
;
Female
;
Male
;
Cross-Sectional Studies
;
Adult
;
Middle Aged
;
Risk Factors
;
Surveys and Questionnaires
;
Contact Tracing/methods*
;
SARS-CoV-2
;
Prevalence
;
Pandemics
2.Experimental study on autologous osteochondral transplantation in the treatment of recurrent anterior dislocation of the shoulder joint with articular cartilage defect in rabbits.
Tao LIU ; Sen FANG ; Fang-Xiang LIU ; Ming-Tao ZHANG ; Zhi-Tao YANG ; Bo-Rong ZHANG ; Jun-Wen LIANG ; Xi-Hao WANG ; Jin JIANG ; Xiang-Dong YUN
China Journal of Orthopaedics and Traumatology 2025;38(6):619-625
OBJECTIVE:
To explore clinical effect of autologous osteochondral transplantation (AOT) in the treatment of recurrent anterior dislocation of the shoulder joint with glenoid cartilage defect in rabbits by establishing a model of recurrent anterior dislocation of the shoulder joint with < 20% glenoid cartilage defect in rabbits.
METHODS:
Twenty-four male New Zealand white rabbits, aged 6-month-old, weighed (2.69±0.17) kg were selected. The labrum of shoulder joint of rabbits was artificially destroyed to establish a model of recurrent anterior dislocation of shoulder joint with cartilage defect. They were divided into AOT surgery group and simple suture group, with 12 rabbits in each group. AOT group were underwent AOT surgery, while simple suture group was treated with simple Bankart suture for recurrent shoulder joint dislocation. At 6 and 12 weeks after operation, 6 rabbits between two groups were sacrificed for sampling. The dietary conditions, activity conditions, mental states of rabbits and healing conditions of grafts in the specimens were observed and compared between two groups. HE staining was used to observe cell creep, cell morphology, inflammatory cell infiltration, fibrochondrocytes and their arrangement. Masson staining was used to observe the formation and arrangement of collagen fibers; Safrane-green staining was used to observe the regeneration of articular cartilage, subchondral bone and bone tissue. Bone mineral density (BMD), bone volume (BV) and trabecular thickness (Tb.Th) between two groups were measured by Micro-CT to evaluate the remodeling of shoulder glenoid bone defects by autologous osteochondral cartilage.
RESULTS:
After different surgical interventions were carried out in both groups of rabbits, at 6 weeks after the operation, the abduction, extension, internal rotation and external rotation of the shoulder joint on the operated side showed limited range of motion compared with the contralateral side, while adduction and forward flexion showed no obvious abnormalities compared with the contralateral side. At 12 weeks after operation, the range motion of tshoulder joints in both groups of rabbits had returned to the state before modeling. The effects of HE staining, Masson staining and safrane-green staining at 12 weeks after operation in both groups were stronger than the staining results at 6 weeks after operation. Moreover, the results of HE staining, Masson staining and safranin fixation green staining in AOT group at 6 and 12 weeks after operation were all higher than those in simple suture group. Micro-CT scan results at 6 and 12 weeks after operation showed that BMD (0.427±0.014), (0.466±0.032) g·cm-3, BV(116.171±3.527), (159.327±3.500) mm3, and Tb.Th (0.230±0.006), (0.285±0.009) mm in AOT group, which were higher than those of simple suture group in BMD(0.358±0.011), (0.384±0.096) g·cm-3, BV(72.657±3.903), (118.713±3.860) mm3, and Tb.Th(0.204±0.009), (0.243±0.007) mm;and the differences were statistically significant (P<0.05).
CONCLUSION
AOT procedure could effectively promote osteogenesis and fibrocartilage regeneration in the cartilage defect area of the shoulder glenoid <20%, which is conducive to reshaping the structure of the shoulder glenoid.
Animals
;
Rabbits
;
Male
;
Transplantation, Autologous
;
Cartilage, Articular/injuries*
;
Shoulder Dislocation/physiopathology*
;
Bone Transplantation
;
Shoulder Joint/surgery*
3.Complications among patients undergoing orthopedic surgery after infection with the SARS-CoV-2 Omicron strain and a preliminary nomogram for predicting patient outcomes.
Liang ZHANG ; Wen-Long GOU ; Ke-Yu LUO ; Jun ZHU ; Yi-Bo GAN ; Xiang YIN ; Jun-Gang PU ; Huai-Jian JIN ; Xian-Qing ZHANG ; Wan-Fei WU ; Zi-Ming WANG ; Yao-Yao LIU ; Yang LI ; Peng LIU
Chinese Journal of Traumatology 2025;28(6):445-453
PURPOSE:
The rate of complications among patients undergoing surgery has increased due to infection with SARS-CoV-2 and other variants of concern. However, Omicron has shown decreased pathogenicity, raising questions about the risk of postoperative complications among patients who are infected with this variant. This study aimed to investigate complications and related factors among patients with recent Omicron infection prior to undergoing orthopedic surgery.
METHODS:
A historical control study was conducted. Data were collected from all patients who underwent surgery during 2 distinct periods: (1) between Dec 12, 2022 and Jan 31, 2023 (COVID-19 positive group), (2) between Dec 12, 2021 and Jan 31, 2022 (COVID-19 negative control group). The patients were at least 18 years old. Patients who received conservative treatment after admission or had high-risk diseases or special circumstances (use of anticoagulants before surgery) were excluded from the study. The study outcomes were the total complication rate and related factors. Binary logistic regression analysis was used to identify related factors, and odds ratio (OR) and 95% confidence interval (CI) were calculated to assess the impact of COVID-19 infection on complications.
RESULTS:
In the analysis, a total of 847 patients who underwent surgery were included, with 275 of these patients testing positive for COVID-19 and 572 testing negative. The COVID-19-positive group had a significantly higher rate of total complications (11.27%) than the control group (4.90%, p < 0.001). After adjusting for relevant factors, the OR was 3.08 (95% CI: 1.45-6.53). Patients who were diagnosed with COVID-19 at 3-4 weeks (OR = 0.20 (95% CI: 0.06-0.59), p = 0.005), 5-6 weeks (OR = 0.16 (95% CI: 0.04-0.59), p = 0.010), or ≥7 weeks (OR = 0.26 (95% CI: 0.06-1.02), p = 0.069) prior to surgery had a lower risk of complications than those who were diagnosed at 0-2 weeks prior to surgery. Seven factors (age, indications for surgery, time of operation, time of COVID-19 diagnosis prior to surgery, C-reactive protein levels, alanine transaminase levels, and aspartate aminotransferase levels) were found to be associated with complications; thus, these factors were used to create a nomogram.
CONCLUSION
Omicron continues to be a significant factor in the incidence of postoperative complications among patients undergoing orthopedic surgery. By identifying the factors associated with these complications, we can determine the optimal surgical timing, provide more accurate prognostic information, and offer appropriate consultation for orthopedic surgery patients who have been infected with Omicron.
Humans
;
COVID-19/complications*
;
Male
;
Female
;
Middle Aged
;
Postoperative Complications/epidemiology*
;
SARS-CoV-2
;
Orthopedic Procedures/adverse effects*
;
Aged
;
Nomograms
;
Adult
;
Retrospective Studies
;
Risk Factors
4.The application of surgical robots in head and neck tumors.
Xiaoming HUANG ; Qingqing HE ; Dan WANG ; Jiqi YAN ; Yu WANG ; Xuekui LIU ; Chuanming ZHENG ; Yan XU ; Yanxia BAI ; Chao LI ; Ronghao SUN ; Xudong WANG ; Mingliang XIANG ; Yan WANG ; Xiang LU ; Lei TAO ; Ming SONG ; Qinlong LIANG ; Xiaomeng ZHANG ; Yuan HU ; Renhui CHEN ; Zhaohui LIU ; Faya LIANG ; Ping HAN
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1001-1008
5.Electrophysiological Signatures of Visual Sensations Elicited by Direct Electrical Stimulation.
Yan-Yan LI ; Bo ZHANG ; Jing WANG ; Yuri B SAALMANN ; Mohsen AFRASIABI ; Peng-Cheng LV ; Hai-Xiang WANG ; Huan-Huan XIANG ; Meng-Yang WANG ; Guo-Ming LUAN ; Robert T KNIGHT ; Liang WANG
Neuroscience Bulletin 2025;41(9):1617-1629
Direct electrical stimulation of the human cortex can produce subjective visual sensations, yet these sensations are unstable. The underlying mechanisms may stem from differences in electrophysiological activity within the distributed network outside the stimulated site. To address this problem, we recruited 69 patients who experienced visual sensations during invasive electrical stimulation while intracranial electroencephalography (iEEG) data were recorded. We found significantly flattened power spectral slopes in distributed regions involving different brain networks and decreased integrated information during elicited visual sensations compared with the non-sensation condition. Further analysis based on minimum information partitions revealed that the reconfigured network interactions primarily involved the inferior frontal cortex, posterior superior temporal sulcus, and temporoparietal junction. The flattened power spectral slope in the inferior frontal gyrus was also correlated with integrated information. Taken together, this study indicates that the altered electrophysiological signatures provide insights into the neural mechanisms underlying subjective visual sensations.
Humans
;
Male
;
Female
;
Adult
;
Visual Perception/physiology*
;
Electric Stimulation
;
Middle Aged
;
Young Adult
;
Electrocorticography
;
Electroencephalography
;
Brain Mapping
6.Associations between Red Cell Indices and Cerebral Blood Flow Velocity in High Altitude.
Hao Lun SUN ; Tai Ming ZHANG ; Dong Yu FAN ; Hao Xiang WANG ; Lu Ran XU ; Qing DU ; Jun LIANG ; Li ZHU ; Xu WANG ; Li LEI ; Xiao Shu LI ; Wang Sheng JIN
Biomedical and Environmental Sciences 2025;38(10):1314-1319
7.Associations of Exposure to Typical Environmental Organic Pollutants with Cardiopulmonary Health and the Mediating Role of Oxidative Stress: A Randomized Crossover Study.
Ning GAO ; Bin WANG ; Ran ZHAO ; Han ZHANG ; Xiao Qian JIA ; Tian Xiang WU ; Meng Yuan REN ; Lu ZHAO ; Jia Zhang SHI ; Jing HUANG ; Shao Wei WU ; Guo Feng SHEN ; Bo PAN ; Ming Liang FANG
Biomedical and Environmental Sciences 2025;38(11):1388-1403
OBJECTIVE:
The study aim was to investigate the effects of exposure to multiple environmental organic pollutants on cardiopulmonary health with a focus on the potential mediating role of oxidative stress.
METHODS:
A repeated-measures randomized crossover study involving healthy college students in Beijing was conducted. Biological samples, including morning urine and venous blood, were collected to measure concentrations of 29 typical organic pollutants, including hydroxy polycyclic aromatic hydrocarbons (OH-PAHs), bisphenol A and its substitutes, phthalates and their metabolites, parabens, and five biomarkers of oxidative stress. Health assessments included blood pressure measurements and lung function indicators.
RESULTS:
Urinary concentrations of 2-hydroxyphenanthrene (2-OH-PHE) ( β = 4.35% [95% confidence interval ( CI): 0.85%, 7.97%]), 3-hydroxyphenanthrene ( β = 3.44% [95% CI: 0.19%, 6.79%]), and 4-hydroxyphenanthrene (4-OH-PHE) ( β = 5.78% [95% CI: 1.27%, 10.5%]) were significantly and positively associated with systolic blood pressure. Exposures to 1-hydroxypyrene (1-OH-PYR) ( β = 3.05% [95% CI: -4.66%, -1.41%]), 2-OH-PHE ( β = 2.68% [95% CI: -4%, -1.34%]), and 4-OH-PHE ( β = 3% [95% CI: -4.68%, -1.29%]) were negatively associated with the ratio of forced expiratory volume in the first second to forced vital capacity. These findings highlight the adverse effects of exposure to multiple pollutants on cardiopulmonary health. Biomarkers of oxidative stress, including 8-hydroxy-2'-deoxyguanosine and extracellular superoxide dismutase, mediated the effects of multiple OH-PAHs on blood pressure and lung function.
CONCLUSION
Exposure to multiple organic pollutants can adversely affect cardiopulmonary health. Oxidative stress is a key mediator of the effects of OH-PAHs on blood pressure and lung function.
Humans
;
Oxidative Stress/drug effects*
;
Male
;
Cross-Over Studies
;
Female
;
Young Adult
;
Environmental Pollutants/toxicity*
;
Environmental Exposure/adverse effects*
;
Biomarkers/blood*
;
Adult
;
Blood Pressure/drug effects*
;
Polycyclic Aromatic Hydrocarbons/urine*
;
Beijing
8.A retrospective study of occlusal reconstruction in patients with old jaw fractures and dentition defects
Ming-Chao DING ; Bo-Ya JING ; Jin SHI ; Liu YANG ; Xiang-Dong LIU ; Jing-Fu WANG ; Shuang QU ; Jia-Wu LIANG ; Zi-Hao TANG ; Jin-Long ZHAO ; Lei TIAN
Chinese Journal of Traumatology 2024;27(5):272-278
Purpose::This study evaluated the methods and clinical effects of multidisciplinary collaborative treatment for occlusal reconstruction in patients with old jaw fractures and dentition defects.Methods::Patients with old jaw fractures and dentition defects who underwent occlusal reconstruction at the Third Affiliated Hospital of Air Force Military Medical University from January 2018 to December 2022 were enrolled. Clinical treatment was classified into 3 phases. In phase I, techniques such as orthognathic surgery, microsurgery, and distraction osteogenesis were employed to reconstruct the correct 3-dimensional (3D) jaw position relationship. In phase II, bone augmentation and soft tissue management techniques were utilized to address insufficient alveolar bone mass and poor gingival soft tissue conditions. In phase III, implant-supported overdentures or fixed dentures were used for occlusal reconstruction. A summary of treatment methods, clinical efficacy evaluation, comparative analysis of imageological examinations, and satisfaction questionnaire survey were utilized to evaluate the therapeutic efficacy in patients with traumatic old jaw fractures and dentition defects. All data are summarized using the arithmetic mean ± standard deviation and compared using independent sample t-tests. Results::In 15 patients with old jaw fractures and dentition defects (an average age of 32 years, ranging from 18 to 53 years), there were 7 cases of malocclusion of single maxillary fracture, 6 of malocclusion of single mandible fracture, and 2 of malocclusion of both maxillary and mandible fractures. There were 5 patients with single maxillary dentition defects, 2 with single mandibular dentition defects, and 8 with both maxillary and mandibular dentition defects. To reconstruct the correct 3D jaw positional relationship, 5 patients underwent Le Fort I osteotomy of the maxilla, 3 underwent bilateral sagittal split ramus osteotomy of the mandible, 4 underwent open reduction and internal fixation for old jaw fractures, 3 underwent temporomandibular joint surgery, and 4 underwent distraction osteogenesis. All patients underwent jawbone augmentation, of whom 4 patients underwent a free composite vascularized bone flap (26.66%) and the remaining patients underwent local alveolar bone augmentation. Free gingival graft and connective tissue graft were the main methods for soft tissue augmentation (73.33%). The 15 patients received 81 implants, of whom 11 patients received implant-supported fixed dentures and 4 received implant-supported removable dentures. The survival rate of all implants was 93.82%. The final imageological examination of 15 patients confirmed that the malocclusion was corrected, and the clinical treatment ultimately achieved occlusal function reconstruction. The patient satisfaction questionnaire survey showed that they were satisfied with the efficacy, phonetics, aesthetics, and comfort after treatment.Conclusion::Occlusal reconstruction of old jaw fractures and dentition defects requires a phased sequential comprehensive treatment, consisting of 3D spatial jaw correction, alveolar bone augmentation and soft tissue augmentation, and implant-supported occlusal reconstruction, achieving satisfactory clinical therapeutic efficacy.
9.Laboratory proficiency testing for creepage distance and electrical clearance test of medical electrical equipment based on GB 9706.1-2020
Xiao-Ming GAO ; Song-Yan XU ; Xiao-Peng HAN ; Zhen-Shi LIANG ; Man ZHANG ; Ting-Ru GUAN ; Hui-Ru WANG ; Yuan-Yuan QU ; Xin-Hua XIANG
Chinese Medical Equipment Journal 2024;45(10):54-59
Objective To clarify the understanding of types of laboratories and manufacturers for GB 9706.1-2020 Medical electrical equipment-Part 1:General requirements for basic safety and essential performance by laboratory proficiency testing for creepage distance and electrical clearance test.Methods An operation guide was formed according to the testing program in GB 9706.1-2020,and the homogeneity and stability of the samples were evaluated according to CNAS-GL003:2018 Guidance on Evaluating the Homogenneity and Stability of Samples Used for Proficiency Testing.Robust statistic methods were used to assess the quantitative parameters of the test results of the participating laboratories according to the requirements in GB/T 28043-2019 Statistical methods for use in proficiency testing by interlaboratory comparison;the results reported by the expert laboratories were used as the specified values of the qualitative parameters.SPSS 25.0 statistical software was used for data analysis.Results All the results of the crreepage distance and electrical clearance tests met the requirements for homogeneity and stability.Of the 46 laboratories involved in,37 ones did have comprehensive satisfactory determinations while the remained 9 ones not.Conclusion Some laboratories don't behave well in understanding the standard,which have to be reformed accordingly to enhance their proficiencies.[Chinese Medical Equipment Journal,2024,45(10):54-59]
10.A reporter gene assays for bioactivity determination of human chorinonic gonadotropin
Ying HUANG ; Xiao-ming ZHANG ; He-yang LI ; Lü-yin WANG ; Hui ZHANG ; Ping LÜ ; Jing LI ; Xiang-dong GAO ; Cheng-gang LIANG
Acta Pharmaceutica Sinica 2024;59(2):432-438
This study constructed a LHCGR-CRE-luc-HEK293 transgenic cell line according to the activation of the cAMP signaling pathway after recombinant human chorionic gonadotropin binding to the receptor. The biological activity of recombinant human chorionic gonadotropin was assayed using a luciferase assay system. The relative potency of the samples was calculated using four-parameter model. And the method conditions were optimized to validate the specificity, relative accuracy, precision and linearity of the method. The results showed that there was a quantitative potency relationship of human chorinonic gonadotropin (hCG) in the method and it was in accordance with the four-parameter curve. After optimization, the conditions were determined as hCG dilution concentration of 2.5 μg·mL-1, dilution ratio of 1∶4, cell number of 10 000-15 000 cells/well, and induction time of 6 h. The method had good specificity, relative accuracy with relative bias ranging from -8.9% to 3.4%, linear regression equation correlation coefficient of 0.996, intermediate precision geometric coefficient of variation ranging from 3.3% to 15.0%, and linearity range of 50% to 200%. This study successfully established and validated a reporter gene method to detect hCG biological activity, which can be used for hCG biological activity assay and quality control.

Result Analysis
Print
Save
E-mail