1.Expert Consensus on Clinical Application of Qidong Yixin Oral Liquid
Changkuan FU ; Xiaochang MA ; Mingjun ZHU ; Yue DENG ; Hongxu LIU ; Mingxue ZHANG ; Ying CHEN ; Yan ZHOU ; Ling ZHANG ; Jianhua FU ; Wei YANG ; Yu'er HU ; Ming CHEN ; Yanming XIE ; Yuanyuan LI
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(4):147-158
The prescription of Qidong Yixin oral liquid is derived from the experience of national medical master Ren Jixue in treating viral myocarditis (VMC). It has the functions of tonifying Qi, nourishing the heart,calming the mind, and relieving palpitations. It is used to treat VMC and angina pectoris of coronary heart disease caused by deficiency of both Qi and Yin. However,the understanding of its efficacy evidence, advantageous aspects, dosage and administration, and medication safety remains insufficient in clinical practice. Therefore,the development of the Expert Consensus on the Clinical Application of Qidong Yixin Oral Liquid (hereinafter referred to as consensus) was initiated. Consensus strictly followed the process and methods of the expert consensus on the clinical application of Chinese patent medicines of the China Association of Chinese Medicine,successively completing multiple tasks such as the consensus project initiation,determination of clinical problems,evidence search and evaluation,formation of recommendation opinions and consensus suggestions,solicitation of opinions,peer review, submission for review and release, and so on. Consensus formed a total of 10 recommendation opinions and 12 consensus suggestions,clarifying the clinical positioning,efficacy advantages,syndrome differentiation,dosage and administration,combination therapy,timing of medication,adverse reactions,contraindications, and precautions of Qidong Yixin oral liquid,indicating that it has good clinical advantages and safety in the treatment of VMC and angina pectoris of coronary heart disease,providing norms and references for physicians to safely and rationally apply Qidong Yixin oral liquid. Consensus was reviewed and approved for release by the Standardization Office of the China Association of Chinese Medicine on December 23, 2024. Standard number:GSCACM-376-2024.
2.Application review of wearable devices in auxiliary detection and diagnosis of acute mountain sickness
Hui-quan WANG ; Shuai MA ; Guo-sheng CHEN ; Yu GUO ; Jin-han YU ; Zheng-xu YAN ; Ming-hu LIU ; Xin-min DONG
Chinese Medical Equipment Journal 2025;46(9):100-107
The pathological mechanisms and related physiological indicators of acute mountain sickness(AMS)were introduced,and the present situation of wearable devices applied in AMS auxiliary detection and diagnosis were reviewed.The challenges and future development directions of wearable devices applied in auxiliary detection and diagnosis were pointed out.[Chinese Medical Equipment Journal,2025,46(9):100-107]
3.Application review of wearable devices in auxiliary detection and diagnosis of acute mountain sickness
Hui-quan WANG ; Shuai MA ; Guo-sheng CHEN ; Yu GUO ; Jin-han YU ; Zheng-xu YAN ; Ming-hu LIU ; Xin-min DONG
Chinese Medical Equipment Journal 2025;46(9):100-107
The pathological mechanisms and related physiological indicators of acute mountain sickness(AMS)were introduced,and the present situation of wearable devices applied in AMS auxiliary detection and diagnosis were reviewed.The challenges and future development directions of wearable devices applied in auxiliary detection and diagnosis were pointed out.[Chinese Medical Equipment Journal,2025,46(9):100-107]
4.Influence of different disinfectants on ultrasound-guided internal jugular vein puncture and adhesive application
Jin-zhu MA ; Hai-yan GAO ; Hao WANG ; Ming-lan YANG ; Chun-hui HU ; Dong-liang WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(2):147-150
Objective To investigate the influence of different disinfectants on the ultrasound-guided internal jugular vein puncture and adhesive application.Methods A total of 102 emergency patients with traumatic hemorrhage who underwent ultrasound-guided internal jugular vein puncture and catheterization were selected as the study subjects and randomly divided into the iodine group(51 cases)and the chlorhexidine-alcohol group(51 cases).Iodophor(0.5%effective iodine)and 2.0%chlorhexidine gluconate+70.0%ethanol were used for disinfection before puncture,respectively.The disinfection effect of the puncture site,puncture condition,ultrasound imaging,and adhesive force of the application of patients were statistically compared between the two groups.Results There was no significant difference in the bacterial count before disinfection,the bacterial count after disinfection or the qualified rate of disinfection at the puncture site of patients between the two groups(P>0.05).There were significant differences in the success rate of one-time puncture,the number of puncture and the time of puncture and catheterization between the two groups(P<0.05).There were significant differences in the rate of clear ultrasound images,adhesive force and rate of warping or shedding of the application between the two groups(P<0.05).Conclusion For emergency patients with traumatic hemorrhage,using iodophor(0.5%effective iodine)and 2.0%chlorhexidine gluconate+70.0%ethanol disinfection before ultrasound-guided internal jugular vein puncture can achieve good disinfection effects.Iodine disinfection can obtain clearer ultrasound images and a higher success rate of one-time puncture,but the adhesive force of the application is poor,making it prone to warping or shedding.
5.Development and application of pilot hypoxia endurance testing system
Lin-xia LI ; Guo-yun MAO ; Ming-rui HU ; Jia-ling XU ; Yao-xuan JI ; Na ZHI ; Yan-qing BAI ; Yun-ying WANG
Chinese Medical Equipment Journal 2025;46(10):23-28
Objective To develop a hypoxia endurance testing system for aviation physiological training of pilots.Methods The hypoxia endurance testing system comprised a low-oxygen mixed gas generator,a pressurization system for low-oxygen mixed gas and a personal breathing apparatus.The low-oxygen mixed gas generator consisted of a main unit composed of an air compressor,a filter,a buffer tank,polymer membrane,a control module,sensors and regulators,wire cables,supporting hoses,etc.;the pressurization system for low-oxygen mixed gas was made up of a protective box,a cooling fan,a motor and a driver,a control module,a solenoid valve,a convergence block,a pressure gauge,etc.;the personal breating apparatus was composed of a gas cylinder,a pressure reducer,an oxygen supply regulator,etc.Forty-eight subjects were selected for hypoxia exposure tests to verify the effectiveness of the system.Results The system developed had the functions of low-oxygen gas preparation,pressurized filling and hypoxia experiment,and the experimental results indicated the acute hypoxia exposure by the system significantly caused signs and symptoms of hypoxia and weakened physiological functions.Conclusion The system developed gains advantages in high accuracy of gas volume fraction control,safety and remarkable effect of simulated hypoxia,and can be an effective tool for acute high-altitude hypoxia testing and training of pilots.[Chinese Medical Equipment Journal,2025,46(10):23-28]
6.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
7.Development and application of pilot hypoxia endurance testing system
Lin-xia LI ; Guo-yun MAO ; Ming-rui HU ; Jia-ling XU ; Yao-xuan JI ; Na ZHI ; Yan-qing BAI ; Yun-ying WANG
Chinese Medical Equipment Journal 2025;46(10):23-28
Objective To develop a hypoxia endurance testing system for aviation physiological training of pilots.Methods The hypoxia endurance testing system comprised a low-oxygen mixed gas generator,a pressurization system for low-oxygen mixed gas and a personal breathing apparatus.The low-oxygen mixed gas generator consisted of a main unit composed of an air compressor,a filter,a buffer tank,polymer membrane,a control module,sensors and regulators,wire cables,supporting hoses,etc.;the pressurization system for low-oxygen mixed gas was made up of a protective box,a cooling fan,a motor and a driver,a control module,a solenoid valve,a convergence block,a pressure gauge,etc.;the personal breating apparatus was composed of a gas cylinder,a pressure reducer,an oxygen supply regulator,etc.Forty-eight subjects were selected for hypoxia exposure tests to verify the effectiveness of the system.Results The system developed had the functions of low-oxygen gas preparation,pressurized filling and hypoxia experiment,and the experimental results indicated the acute hypoxia exposure by the system significantly caused signs and symptoms of hypoxia and weakened physiological functions.Conclusion The system developed gains advantages in high accuracy of gas volume fraction control,safety and remarkable effect of simulated hypoxia,and can be an effective tool for acute high-altitude hypoxia testing and training of pilots.[Chinese Medical Equipment Journal,2025,46(10):23-28]
8.Preliminary application of sacral neuromodulation in patients with benign prostatic hyperplasia complicated with underactive bladder after transurethral resection of the prostate
Ning LIU ; Yan ZHANG ; Tao LI ; Qiang HU ; Kai LU ; Lei ZHANG ; Jianping WU ; Shuqiu CHEN ; Bin XU ; Ming CHEN
Journal of Modern Urology 2025;30(1):39-42
[Objective] To evaluate the efficacy and safety of sacral neuromodulation (SNM) in the treatment of patients with benign prostatic hyperplasia (BPH) complicated with underactive bladder (UAB) who respond poorly to transurethral resection of the prostate (TURP). [Methods] A retrospective analysis was performed on 10 patients with BPH and UAB treated with TURP by the same surgeon in Zhongda Hospital Southeast University during Jan.2018 and Jan.2023.The residual urine volume was not significantly relieved after operation, and the maximum urine flow rate and urine volume per discharge were not significantly improved.All patients underwent phase I SNM, and urinary diaries were recorded before and after surgery to observe the average daily frequency of urination, volume per urination, maximum urine flow rate, and residual urine volume. [Results] The operation time was (97.6±11.2) min.During the postoperative test of 2-4 weeks, if the residual urine volume reduction by more than 50% was deemed as effective, SNM was effective in 6 patients (60.0%). Compared with preoperative results, the daily frequency of urination [(20.2±3.8) times vs. (13.2±3.2) times], volume per urination [(119.2±56.7) mL vs. (246.5±59.2) mL], maximum urine flow rate [(8.7±1.5) mL/s vs. (16.5±2.6) mL/s], and residual urine volume [(222.5±55.0) mL vs. (80.8±16.0) mL] were significantly improved, with statistical significance (P<0.05). There were no complications such as bleeding, infection, fever or pain.The 6 patients who had effective outcomes successfully completed phase II surgery, and the fistula was removed.During the follow-up of 1 year, the curative effect was stable, and there were no complications such as electrode displacement, incision infection, or pain in the irritation sites.The residual urine volume of the other 4 unsuccessful patients did not improve significantly, and the electrodes were removed and the vesicostomy tube was retained. [Conclusion] SNM is safe and effective in the treatment of BPH with UAB patients with poor curative effects after TURP.
9.Morphology of enteric nervous system in C57BL/6 mice based on fMOST high-resolution 3D reconstruction system
Li-Ge LENG ; Guan-Xiong YANG ; Ze-En WANG ; Yi CHEN ; Zhi-Liang QIAO ; Qing-Zhong HU ; Ming-Yan WANG ; Feng TIAN
Acta Anatomica Sinica 2025;56(1):114-119
Objective To initially explore the possibility of applying the fluorescence micro-optical sectioning tomography(fMOST)high-resolution 3D reconstruction system to the morphological study of the intestinal nervous system and to preliminarily establish a method for studying the morphology of the intestinal nervous system using this system.Methods fMOST high-resolution 3D reconstruction system was used to study the intestinal nervous system of C57BL/6 mice in detail.Based on this method,a new morphological method of the visceral nervous system of small animal models was explored at the single-cell level.Results Compared with the large intestine,the small intestine lacked the typical myenteric plexus(Auerbach),deep mucosal plexus(Henley),and submucosal superficial plexus(Meissner).Conclusion The result of this paper provide a clearer and systematic display of the anatomical structure of the enteric nervous system in C57BL/6 mice,and further clarify the similarities and differences between the enteric nervous system of mice and human,and provide a theoretical basis for its rational application in the study of digestive system diseases.The morphological study of fMOST high-resolution 3D reconstruction system is not limited to the central nervous system,but can be extended to the morphological study of multiple visceral nervous systems.
10.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.

Result Analysis
Print
Save
E-mail