1.Sclera Vessel Segmentation Based on Fusion Filtering and Reflection Suppression
Ming-Xuan FAN ; Zong-Qing MA ; Chu-Xiang GAO ; Yi-Xuan SHI ; Zi-Hang ZHANG ; Zhe-Xuan JIA ; Fan FAN ; Guo-Liang HUANG ; Jiang ZHU
Progress in Biochemistry and Biophysics 2026;53(5):1195-1206
ObjectiveIn traditional Chinese medicine (TCM), the foundational doctrine that the eyes reflect the essence of the internal viscera establishes ocular observation as a cornerstone of diagnostic practice. Specifically, the morphological characteristics and coloration variations of the scleral microvasculature serve as critical clinical indicators for assessing the dynamic balance of Qi and Blood, as well as the pathological status of internal organs. Historically, however, TCM eye diagnosis has relied predominantly on the subjective clinical experience and visual acuity of individual practitioners, leading to inherent challenges in standardization and reproducibility. While automated computer-aided diagnostic systems offer a promising solution, existing vessel segmentation algorithms encounter significant domain-specific bottlenecks when applied to scleral imagery. These challenges primarily stem from the highly reflective and moist nature of the ocular surface, which generates severe reflective interference. Furthermore, the inherent low contrast of fine capillary networks against complex background textures, compounded by non-uniform illumination, frequently results in high false-positive rates, misdetections, and severe vessel fragmentation. To address these critical limitations and advance the objective quantification of TCM diagnostics, this paper proposes a novel, highly robust sclera vessel segmentation framework that innovatively integrates Frangi-Sato dual-filter adaptive enhancement with pixel-level reflection detection. MethodsThe proposed methodology systematically addresses the segmentation pipeline through three synergistic stages. First, to overcome the structural limitations of single-filter approaches, a multi-scale weighted fusion strategy is meticulously designed to harness the complementary extraction capabilities of both Frangi and Sato filters. This adaptive enhancement optimally balances the preservation of main vessel trunk continuity with the heightened sensitivity required for delineating delicate, low-contrast peripheral capillaries. Second, to tackle the persistent issue of reflective highlights, a sophisticated multi-feature synergistic reflection detection module is introduced. By jointly analyzing local information entropy, gradient field variations, and intensity statistical distributions, this module achieves precise, pixel-level identification and elimination of reflective artifacts without compromising the underlying vascular structures. Finally, a dual-level adaptive thresholding strategy, featuring an innovative “core protection” mechanism, is implemented. This critical step effectively suppresses complex background noise while rigorously preserving the structural and topological integrity of the intricate vessel network, preventing the structural breaks often seen in conventional binarization methods. ResultsThe efficacy of the proposed framework was rigorously evaluated using both self-constructed clinical datasets specifically acquired for TCM research and standardized public datasets. Extensive experimental results demonstrate that the proposed method consistently outperforms state-of-the-art traditional approaches and contemporary deep learning models. Specifically, the proposed method achieves a Dice similarity coefficient of approximately 0.71 on the private clinical dataset, and secures the best performance across the majority of quantitative metrics on both datasets. Notably, the framework exhibits exceptional robustness and generalization capabilities in highly challenging scenarios characterized by intense reflective interference, low signal-to-noise ratios, and cross-domain image variations. ConclusionThis study successfully realizes the high-integrity, automated segmentation of scleral vessel networks under complex clinical imaging conditions. By overcoming the fundamental algorithmic challenges of reflection interference and micro-vessel loss, the proposed methodology provides potential support for the digitization, objective standardization, and intelligent advancement of modern TCM eye diagnosis systems.
2.Sclera Vessel Segmentation Based on Fusion Filtering and Reflection Suppression
Ming-Xuan FAN ; Zong-Qing MA ; Chu-Xiang GAO ; Yi-Xuan SHI ; Zi-Hang ZHANG ; Zhe-Xuan JIA ; Fan FAN ; Guo-Liang HUANG ; Jiang ZHU
Progress in Biochemistry and Biophysics 2026;53(5):1195-1206
ObjectiveIn traditional Chinese medicine (TCM), the foundational doctrine that the eyes reflect the essence of the internal viscera establishes ocular observation as a cornerstone of diagnostic practice. Specifically, the morphological characteristics and coloration variations of the scleral microvasculature serve as critical clinical indicators for assessing the dynamic balance of Qi and Blood, as well as the pathological status of internal organs. Historically, however, TCM eye diagnosis has relied predominantly on the subjective clinical experience and visual acuity of individual practitioners, leading to inherent challenges in standardization and reproducibility. While automated computer-aided diagnostic systems offer a promising solution, existing vessel segmentation algorithms encounter significant domain-specific bottlenecks when applied to scleral imagery. These challenges primarily stem from the highly reflective and moist nature of the ocular surface, which generates severe reflective interference. Furthermore, the inherent low contrast of fine capillary networks against complex background textures, compounded by non-uniform illumination, frequently results in high false-positive rates, misdetections, and severe vessel fragmentation. To address these critical limitations and advance the objective quantification of TCM diagnostics, this paper proposes a novel, highly robust sclera vessel segmentation framework that innovatively integrates Frangi-Sato dual-filter adaptive enhancement with pixel-level reflection detection. MethodsThe proposed methodology systematically addresses the segmentation pipeline through three synergistic stages. First, to overcome the structural limitations of single-filter approaches, a multi-scale weighted fusion strategy is meticulously designed to harness the complementary extraction capabilities of both Frangi and Sato filters. This adaptive enhancement optimally balances the preservation of main vessel trunk continuity with the heightened sensitivity required for delineating delicate, low-contrast peripheral capillaries. Second, to tackle the persistent issue of reflective highlights, a sophisticated multi-feature synergistic reflection detection module is introduced. By jointly analyzing local information entropy, gradient field variations, and intensity statistical distributions, this module achieves precise, pixel-level identification and elimination of reflective artifacts without compromising the underlying vascular structures. Finally, a dual-level adaptive thresholding strategy, featuring an innovative “core protection” mechanism, is implemented. This critical step effectively suppresses complex background noise while rigorously preserving the structural and topological integrity of the intricate vessel network, preventing the structural breaks often seen in conventional binarization methods. ResultsThe efficacy of the proposed framework was rigorously evaluated using both self-constructed clinical datasets specifically acquired for TCM research and standardized public datasets. Extensive experimental results demonstrate that the proposed method consistently outperforms state-of-the-art traditional approaches and contemporary deep learning models. Specifically, the proposed method achieves a Dice similarity coefficient of approximately 0.71 on the private clinical dataset, and secures the best performance across the majority of quantitative metrics on both datasets. Notably, the framework exhibits exceptional robustness and generalization capabilities in highly challenging scenarios characterized by intense reflective interference, low signal-to-noise ratios, and cross-domain image variations. ConclusionThis study successfully realizes the high-integrity, automated segmentation of scleral vessel networks under complex clinical imaging conditions. By overcoming the fundamental algorithmic challenges of reflection interference and micro-vessel loss, the proposed methodology provides potential support for the digitization, objective standardization, and intelligent advancement of modern TCM eye diagnosis systems.
3.Genetic differentiation of Anopheles sinensis (Diptera: Culicidae) based on COⅠ and ITS2 sequences
Gang WANG ; Chun-juan SHI ; Dan KONG ; Xuan ZHU ; Ji HE ; Ming-hui ZHAO ; Chong-cai WANG
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):90-95
Objective Exploring genetic differences among geographic strains of Anopheles sinensis in China. Methods Based on the mitochondrial cytochrome oxidase subunit I(COⅠ )and ribosomal the second internal transcribed spacer(ITS2), genetic distance analyses were conducted on An. sinensis samples collected nationwide. Results Genetic differentiation was observed within An. sinensis geographic strains, primarily reflected in the genetic distances of COⅠ sequences, with some distances between samples exceeding those between closely related species. However, ITS2 sequences showed relatively low levels of differentiation within geographic strains. No significant separation was observed, and gene exchange exhibited a random pattern among geographic strains. Conclusions Significant differences in genetic distance were observed among An. sinensis samples, along with evidence of interspecific continuity among sibling species. For the identification of closely related species using wild-collected Anopheles mosquitoes samples, reliance solely on commonly used barcodes such as COⅠ and ITS2 may be insufficient. Additional molecular markers, including COⅡ and D3 gene fragments, should also be considered. Caution should be exercised when using COⅠ genes to identify cryptic species, especially within Anopheles mosquitoes.
4.A Retrospective Study of Pregnancy and Fetal Outcomes in Mothers with Hepatitis C Viremia.
Wen DENG ; Zi Yu ZHANG ; Xin Xin LI ; Ya Qin ZHANG ; Wei Hua CAO ; Shi Yu WANG ; Xin WEI ; Zi Xuan GAO ; Shuo Jie WANG ; Lin Mei YAO ; Lu ZHANG ; Hong Xiao HAO ; Xiao Xue CHEN ; Yuan Jiao GAO ; Wei YI ; Yao XIE ; Ming Hui LI
Biomedical and Environmental Sciences 2025;38(7):829-839
OBJECTIVE:
To investigate chronic hepatitis C virus (HCV) infection's effect on gestational liver function, pregnancy and delivery complications, and neonatal development.
METHODS:
A total of 157 HCV antibody-positive (anti-HCV[+]) and HCV RNA(+) patients (Group C) and 121 anti-HCV(+) and HCV RNA(-) patients (Group B) were included as study participants, while 142 anti-HCV(-) and HCV RNA(-) patients (Group A) were the control group. Data on biochemical indices during pregnancy, pregnancy complications, delivery-related information, and neonatal complications were also collected.
RESULTS:
Elevated alanine aminotransferase (ALT) rates in Group C during early, middle, and late pregnancy were 59.87%, 43.95%, and 42.04%, respectively-significantly higher than Groups B (26.45%, 15.70%, 10.74%) and A (23.94%, 19.01%, 6.34%) ( P < 0.05). Median ALT levels in Group C were significantly higher than in Groups A and B at all pregnancy stages ( P < 0.05). No significant differences were found in neonatal malformation rates across groups ( P > 0.05). However, neonatal jaundice incidence was significantly greater in Group C (75.16%) compared to Groups A (42.25%) and B (57.02%) ( χ 2 = 33.552, P < 0.001). HCV RNA positivity during pregnancy was an independent risk factor for neonatal jaundice ( OR = 2.111, 95% CI 1.242-3.588, P = 0.006).
CONCLUSIONS
Chronic HCV infection can affect the liver function of pregnant women, but does not increase the pregnancy or delivery complication risks. HCV RNA(+) is an independent risk factor for neonatal jaundice.
Humans
;
Female
;
Pregnancy
;
Adult
;
Pregnancy Complications, Infectious/epidemiology*
;
Retrospective Studies
;
Pregnancy Outcome
;
Infant, Newborn
;
Viremia/virology*
;
Hepatitis C
;
Hepacivirus/physiology*
;
Hepatitis C, Chronic/virology*
;
Young Adult
;
Alanine Transaminase/blood*
5.Study on the role of plasma exosome miR-622 in cachexia of hepatocellular carcinoma
Chao QIN ; Jinyan HOU ; Mei ZHU ; Ming GUAN ; Xuan DENG
International Journal of Laboratory Medicine 2025;46(13):1641-1646
Objective To explore the role of plasma exosome microRNA-622(miR-622)in cachexia of hep-atocellular carcinoma(HCC).Methods Select preoperative blood samples from 40 patients with stage Ⅲ-ⅣHCC and 33 patients with non HCC liver benign diseases collected at Huashan Hospital,Fudan University from 2021 to 2024 as the research subjects.Exosomes were isolated from the plasma of patients,human HCC cell lines(HepG2,Hep3B,PLC,Huh7),and the culture supernatants of primary human hepatocytes(PHH)by differential centrifugation.The relative expression level of miR-622 was detected by real-time fluorescence quantitative polymerase chain reaction.The level of lipolysis was assessed by determining the concentration of glycerol and fatty acids in adipocyte culture medium.Results Plasma exosome miR-622 levels in HCC pa-tients were positively correlated with subcutaneous adipose index and visceral adipose index(r=0.516,0.539,P<0.05).HCC cell conditional medium was able to significantly increase the lipolysis level of adipo-cytes.The relative expression levels of miR-622 in exosomes from HCC cells(HepG2,Hep3B,PLC,Huh7)were significantly lower than those in exosomes from PHH,with values of 0.13±0.04,0.28±0.08,0.23±0.07,and 0.24±0.04,respectively,compared to 1.00±0.18 in PHH exosomes.Further studies revealed that plasma exosome of HCC patients treatment was able to lead to a decrease in the relative expression level of miR-622 in adipocytes,as well as an enhancement of lipolysis.Conclusion The expression of plasma exosomal miR-622 is downregulated in HCC patients.HCC cells can deliver miR-622 to adipocytes via exosomes to reg-ulate lipolysis.Plasma exosomal miR-622 may serve as a potential biomarker for predicting HCC cachexia and a therapeutic target.
6.Research progress in machine learning in processing and quality evaluation of traditional Chinese medicine decoction pieces.
Han-Wen ZHANG ; Yue-E LI ; Jia-Wei YU ; Qiang GUO ; Ming-Xuan LI ; Yu LI ; Xi MEI ; Lin LI ; Lian-Lin SU ; Chun-Qin MAO ; De JI ; Tu-Lin LU
China Journal of Chinese Materia Medica 2025;50(13):3605-3614
Traditional Chinese medicine(TCM) decoction pieces are a core carrier for the inheritance and innovation of TCM, and their quality and safety are critical to public health and the sustainable development of the industry. Conventional quality control models, while having established a well-developed system through long-term practice, still face challenges such as relatively long inspection cycles, insufficient objectivity in characterizing complex traits, and urgent needs for improving the efficiency of integrating multidimensional quality information when confronted with the dual demands of large-scale production and precision quality control. With the rapid development of artificial intelligence, machine learning can deeply analyze multidimensional data of the morphology, spectroscopy, and chemical fingerprints of decoction pieces by constructing high-dimensional feature space analysis models, significantly improving the standardization level and decision-making efficiency of quality evaluation. This article reviews the research progress in the application of machine learning in the processing, production, and rapid quality evaluation of TCM decoction pieces. It further analyzes current challenges in technological implementation and proposes potential solutions, offering theoretical and technical references to advance the digital and intelligent transformation of the industry.
Machine Learning
;
Drugs, Chinese Herbal/standards*
;
Quality Control
;
Medicine, Chinese Traditional/standards*
;
Humans
7.Quality evaluation of Hibisci Mutabilis Folium based on fingerprint and quantitative analysis of multi-components by single-marker method.
Ming CHEN ; Zhen-Hai YUAN ; Xuan TANG ; Dong WANG ; Zhi-Yong ZHENG ; Jing FENG ; Dai-Zhou ZHANG ; Fang WANG
China Journal of Chinese Materia Medica 2025;50(16):4619-4629
To improve the quality evaluation system of Hibisci Mutabilis Folium, this study established high performance liquid chromatography(HPLC) fingerprints of Hibisci Mutabilis Folium and evaluated the quality differences of medicinal materials from different places of production by chemometrics. Furthermore, a content measurement method of differential components was established based on quantitative analysis of multi-components by single-marker(QAMS). The fingerprints of 17 batches of Hibisci Mutabilis Folium from different places of production were constructed, with a total of 19 common peaks marked and seven components confirmed. The similarity between the sample fingerprints and the reference fingerprints ranged from 0.890 to 0.974. By utilizing principal component analysis(PCA), hierarchical cluster analysis(HCA), and orthogonal partial least squares-discriminant analysis(OPLS-DA), the chemical patterns of fingerprints were identified. Five components that could be used to evaluate the quality differences of Hibisci Mutabilis Folium were screened, namely peak 6(quercetin 3-O-β-robinobioside), peak 7(rutin), peak 9(kaempferol-3-O-β-robinobioside), peak 10(kaempferol-3-O-rutinoside), and peak 14(tiliroside). The relative correction factors of isoquercitrin, kaempferol-3-O-β-robinobioside, kaempferol-3-O-rutinoside, kaempferol-3-O-β-D-glucoside, and tiliroside were measured with rutin as the internal reference. The QAMS method was established for the content measurement of six flavonoids, and the results showed there was no significant difference compared to the results obtained by an external standard method. In summary, the HPLC fingerprints and QAMS method established in the study, demonstrating stability and accuracy, can provide a reference for the overall quality evaluation of Hibisci Mutabilis Folium.
Chromatography, High Pressure Liquid/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Principal Component Analysis
8.Investigation of effects of petroleum ether fraction from Derris eriocarpa on glucose and lipid metabolism in a mouse model of metabolic syndrome via ATF3/HNF4ɑ/CYP7A1 pathway
Jing YAN ; Jie WENG ; Xuan ZHANG ; Xue LI ; Chao-nan KONG ; Hong-cun LIU ; Li-fang YANG ; Ming-guo JIANG ; Qiu-yan LIANG ; Li-ting HE
Chinese Traditional Patent Medicine 2025;47(9):2902-2911
AIM To investigate effects of petroleum ether fraction from Derris eriocarpa How on glucose and lipid metabolism in a mouse model of metabolic syndrome(MS).METHODS KM mice were fed a high-fat diet and administered streptozotocin intraperitoneally to establish MS models.The MS mice were then randomly assigned to the model group,the metformin hydrochloride group,the lovastatin group,the ursolic acid group,and the high-,medium-and low-dose D.eriocarpa petroleum ether fraction groups,with 10 mice in each group.Ten additional mice maitained on a normal diet served as the normal control group.After 4 weeks of intragastric administration,glucose and lipid metabolism indicators were measured.Hepatic pathological changes were assessed using HE staining and oil red O staining.Liver tissue mRNA expressions of ATF3,PEPCK,FXR,CYP7A1,HNF4ɑ,CYP8B1 and SRB1 were quantified by RT-qPCR.Hepatic protein expressions of ATF3,HNF4ɑ,PEPCK,FXR and CYP7A1 was analyzed by Western blot in MS mice.RESULTS Compared to the model group,the high-dose D.eriocarpa petroleum ether fraction group exhibited significant glucose tolerance improvement(reduced OGTT-AUC,P<0.01);favorable serum lipid modulation in terms of increased HDL-C levels(P<0.01)and decreased TG,TC,LDL-C(P<0.01);reduced renal biomarkers(BUN,SCR)and hepatotoxic indicators of TBA,AST and ALT activities(P<0.01);alleviated hepatic lipid accumulation and histopathological damage;downregulated mRNA and protein expressions of ATF3,HNF4ɑ and PEPCK,as well as CYP8B1 mRNA expression(P<0.01);and upregulated mRNA and protein expressions of FXR and CYP7A1,along with SRB1 mRNA expression(P<0.01).CONCLUSION D.eriocarpa petroleum ether fraction ameliorates glucose and lipid metabolism dysregulation in MS mice by modulating the ATF3/HNF4ɑ/CYP7A1 signaling pathway,consequently eliciting hypoglycemic,hypolipidemic,hepatoprotective and nephroprotective effects.
9.Research progress on the association between blood pressure variability and cognitive decline
Li ZHAO ; Teng ZHANG ; Yilian ZHANG ; Xuan WU ; Ming YANG ; Xiaotian XU
Chinese Journal of Neurology 2025;58(7):799-807
Cognitive decline is an early sign of dementia, mainly manifested as the ability to learn new knowledge and memory decline in the near future, so early detection, early diagnosis, early treatment are an important research direction to alleviate dementia population. Previous studies have shown that blood pressure variability (BPV) is an important risk factor for cognitive decline. At present, there is a lack of systematic understanding of the specific effects of BPV on different subdomains of cognitive function and the treatment standard of BPV. This paper reviews the existing clinical studies, emphasizes that abnormal BPV causes adverse cognitive outcomes in all age groups, and proposes future research directions.
10.Comparative efficacy of robot-assisted balloon tibioplasty and traditional open reduction and internal fixation in the treatment of AO/OTA type 41B2 tibial plateau fracture
Jialang HU ; Jing JIAO ; Yucheng HUANG ; Wen XIONG ; Jinyi WU ; Hai DENG ; Zhihua GENG ; Xuan MA ; Ming CHEN
Chinese Journal of Trauma 2025;41(4):369-376
Objective:To compare the clinical efficacy of robot-assisted balloon tibioplasty and traditional open reduction and internal fixation in the treatment of AO/OTA type 41B2 tibial plateau fracture.Methods:A retrospective cohort study was conducted to analyze the clinical data of 70 patients with AO/OTA type 41B2 tibial plateau fracture who were admitted to Wuhan Fourth Hospital from September 2019 to October 2022, including 35 males and 35 females, aged 24-62 years [(44.9±9.5)years]. Among them, 41 patients underwent traditional open reduction and internal fixation (open reduction group), while 29 patients underwent robot-assisted balloon tibioplasty (balloon group). The following parameters were compared between the two groups: incision length, operative blood loss, number of intraoperative fluoroscopies, operation duration, and length of hospital stay; Rasmussen radiological scores at 3 days, 3 months postoperatively, and at the last follow-up and the fracture healing time; pain visual analogue scale (VAS) scores preoperatively, and at 2 days and 3 months postoperatively; knee joint range of motion at 5 days, 3 months postoperatively, and at the last follow-up; Hospital for Special Surgery (HSS) knee function scores at 3, 6 months postoperatively, and at the last follow-up; incidence rate of complications at 15 days postoperatively.Results:All the patients were followed for 12-24 months [18(17, 20)months]. The incision length, operative blood loss and length of hospital stay in the balloon group were 1.6(1.5, 3.0)cm, 5.0(5.0, 5.0)ml and 11.0(9.0, 14.0)days, less than those in the open reduction group [12.0(11.0, 12.0)cm, 100.0(50.0, 120.0)ml and 15.0(13.0, 20.0)days] ( P<0.01). The number of intraoperative fluoroscopies and operation duration in the open reduction group were 9.0(7.0, 10.0)times and 75.0(60.0, 90.0)minutes, less than those in the balloon group [336.0(335.0, 340.0)times and [90.0(70.0, 105.0)minutes] ( P<0.05). There were no significant differences in the Rasmussen radiological scores between the two groups at 3 days, 3 months postoperatively, or at the last follow-up ( P>0.05). The fracture healing time in the balloon group was 3.0(3.0, 3.0)months, shorter than 3.0(3.0, 3.5)months in the open reduction group ( P<0.05). No significant differences were observed between the two groups in VAS scores before operation or at 3 months postoperatively ( P>0.05). However, the VAS score was 2.0(2.0, 3.0)points at 2 days postoperatively in the balloon group, lower than 5.0(5.0, 6.0)points in the open reduction group ( P<0.01). The knee joint range of motion at 5 days, 3 months postoperatively and at the last follow-up were 90.0(85.0, 90.0)°, 135.0(130.0, 135.0)° and 140.0(135.0, 140.0)° in the balloon group, better than 65.0(60.0, 70.0)°, 125.0(120.0, 130.0)°, 130.0(130.0, 140.0)° in the open reduction group ( P<0.01). Similarly, the HSS knee function scores at 3, 6 months postoperatively and at the last follow-up were 80.0(80.0, 81.0)points, 91.0(90.0, 92.0)points, and 95.0(93.0, 96.0)points in the balloon group, better than 71.0(70.0, 72.0)points, 83.0(81.0, 84.0)points, and 86.0(84.0, 88.0)points in the open reduction group ( P<0.01). The incidence rate of complications in the balloon group was 0, comparable to 12% (5/41) in the open reduction group ( P>0.05). Conclusion:Compared with traditional open reduction and internal fixation surgery, robot-assisted balloon tibioplasty in the treatment of AO/OTA type 41B2 tibial plateau fracture significantly reduces surgical trauma, alleviates postoperative pain, promotes fracture healing, and accelerates functional recovery of the affected limbs.


Result Analysis
Print
Save
E-mail