1.Multidimensional analysis of concurrent proximal bronchiolar adenoma and lung carcinoma
Lu-Yao LI ; Gong-Ming DONG ; Yun-Peng ZHANG ; Ting-Ting WANG ; Fu-Quan JIA ; Guan-Jun ZHANG
Journal of Pathology and Translational Medicine 2026;60(3):356-363
Bronchiolar adenoma (BA) is a rare type of lung tumor characterized by bilayered epithelial cells having a continuous basal layer and a luminal layer. It resembles mucinous adenocarcinoma (MA) on frozen section, with difficulty in distinguishing the basal layer. Immunohistochemistry is the best choice for verifying the diagnosis. This study aimed to comprehensively characterize three cases of BA-combined carcinoma using clinical, histopathological, and genetic features. BA and carcinoma sections were subjected to next-generation sequencing, respectively. It was hypothesized that while different mutation forms matched different regions, BA and lung adenocarcinoma shared the same gene mutation when they co-occurred in the same location. BA with extensive carcinoma is extremely rare and presents diagnostic challenges due to its overlap with conditions such as MA. Because of its distinctive morphological characteristics, BA may be regarded as a low-grade malignancy, particularly during a confusing evaluation. A multifaceted examination of clinical, radiological, immunohistochemical, and genetic data is necessary for an accurate diagnosis.
2.Treatment Modalities and Long-Term Outcomes in Unruptured Vertebrobasilar Fusiform Aneurysms: A Nationwide Observational Cohort Study
Linggen DONG ; Dachao WEI ; Xiheng CHEN ; Mingtao LI ; Yang ZHAO ; Yong SUN ; Qingbin NIE ; Jun FENG ; Guomin XIAO ; Jinghua ZHOU ; Shengli HU ; Lifei FENG ; Lifeng QI ; Hongen LIU ; Geng GUO ; Yufang LI ; Renfu TIAN ; Jianghua YU ; Dianshi JIN ; Liang HAO ; Tian TIAN ; Shizhong ZHANG ; Yang WANG ; Liping LIU ; Ming LV
Journal of Stroke 2026;28(2):250-262
Background:
and Purpose Vertebrobasilar fusiform aneurysms (VBFAs) carry substantial morbidity and mortality, but optimal management for unruptured VBFAs remains unclear. We compared the safety and efficacy of conservative management (CM), stent-assisted coiling (SAC), and flow diverters (FDs) in patients with unruptured VBFAs, focusing on long-term prognosis.
Methods:
This study included data from a nationwide Chinese cohort of patients with vertebrobasilar dissecting aneurysms. Inverse probability of treatment weighting (IPTW) balanced confounders across groups. The primary outcome was poor prognosis (modified Rankin Scale score >2). Secondary outcomes included aneurysm rupture, ischemic stroke, compression symptoms, and VBFA-related deaths. Logistic regression estimated odds ratios (ORs) and 95% confidence intervals (CIs). Subgroup and sensitivity analyses were performed.
Results:
Among 1,115 patients with unruptured VBFAs, 838 (median age, 54 years; 655 men) were included. After IPTW, baseline characteristics were balanced. Median follow-up was 54 months. FD was associated with a lower risk of poor prognosis than CM (OR, 0.48 [95% CI, 0.30 to 0.77]; p=0.002), with no difference between CM and SAC. FD also reduced aneurysm rupture (OR, 0.20 [95% CI, 0.07 to 0.60]; p=0.004) and compression symptoms (OR, 0.30 [95% CI, 0.13 to 0.68]; p=0.004) versus CM. Time-to-event analyses further revealed significant differences in vertebral artery lesions and Type I–II VBFAs, whereas no significant differences were observed in basilar or vertebrobasilar junction lesions or in Type III–IV VBFAs.
Conclusions
Compared with CM, FD was associated with improved long-term outcomes in unruptured VBFAs, particularly in vertebral artery lesions and Type I–II VBFAs, although residual confounding cannot be excluded.
3.Differences in deltamethrin resistance and kdr gene mutation in Culex tritaeniorhynchus population in and outside the Yellow Sea wetland
Xiao-er ZHANG ; Zhi-ming WU ; Ye TIAN ; Qian CUI ; Yu-qian JI ; Huan WANG ; Shu-juan YANG ; Yi-chao ZHAO ; Yu WANG ; Hua-yu YIN ; Yu DING ; Guo-jin YAN ; Min-sen ZHAO ; Shou-gang ZHANG ; Bing-dong SONG ; Hong-na CHEN ; Jian GAO ; Wei-fang YANG ; Yu-fu ZHANG ; Hui LIU ; Hong-liang CHU
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):101-107
Objective To gain insights into the biological characteristics of different populations of Culex tritaeniorhynchus within and around the Yellow Sea wetland from the perspective of the occurrence of resistance, we investigated the levels of resistance to deltamethrin and kdr gene mutation in the wetland and its peripheral areas. Methods Specimens were collected from Cx. tritaeniorhynchus populations at two monitoring sites in the Rare Bird National Nature Reserve and Tiaozi Ni Wetland Scenic Area, and also from two populations in Yancheng City and the Liuhe District of Nanjing, and the resistance of these mosquitoes to deltamethrin was determined using the CDC biotest bottle method. For each concentration of deltamethrin assessed, a random subset of exposed specimens was selected for amplification of the kdr gene fragment, followed by Sanger sequencing to identify and analyze resistance-associated mutations. Results The LC50 levels of deltamethrin among mosquitoes from the four populations in Luhe, Yancheng, the Rare Bird National Nature Reserve and the Tiaozi Ni Wetland Scenic Area were 2.048 5, 7.798 2, 3.473 3, and 17.695 5 mg/mL, respectively, with corresponding concentrations of deltamethrin ranging from 0.005 to 5.000,0.050 to 50.000,0.050 to 25.000 and 0.050 to 50.000 mg/mL, respectively. Furthermore, the ranges of the KT50 values were 11.76-107.43, 67.05-216.30,29.77-107.43 and 28.40-329.51 min; the 1-h knockdown rates were 34.58%-99.15%, 9.52%-43.80%, 55.09%-73.01%, and 10.09%-68.07%; and the 24-h mortality rates were 12.15%-67.52%,9.52%-79.56%,13.17%-82.21%, and 11.01%-78.99%, respectively. With respect to kdr gene mutation, we assayed a total of 63,70,59, and 57 mosquitoes for the four populations, for which we detected L1014F mutation frequencies of 14.29%, 35.00%, 20.34%, and 31.58%, respectively, with a majority of these mutations being heterozygous for resistance. In addition, five adult mosquitoes were identified has having synonymous mutations at site 1011[i. e. , AAT(asparagine)mutation to AAC(asparagine)]. Conclusions Our findings revealed the clear resistance of Cx. tritaeniorhynchus to deltamethrin in the Yancheng region of the Yellow Sea wetland, and the resistance phenotype and kdr frequency of Cx. tritaeniorhynchus in the wetland environment were comparable to those of Cx. tritaeniorhynchus in the wetland environment, thereby indicating that the resistance of different populations of Cx. tritaeniorhynchus was homogeneous under the pressure of different insecticide selection within and around the wetland. However, the underlying mechanisms need to be further studied.
4.Morphological identification of Lispe pumila (Diptera: Muscidae)
Shun-fang HUANG ; Ying SU ; Zi-dong CHENG ; Guo-sheng LIAN ; Ming-jian KE
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):141-143
In March 2024, three male and two female specimens of the genus Lispe were intercepted on cargo ships inbound for Wan Zai Port under Gongbei Customs. Based on morphological characteristics and molecular analysis, the specimens were identified as Lispe pumila. In this study, we describe the morphological features, diagnostic characteristics, and geographical distribution of L. pumila, with the aim of providing a reference for the identification of this species when intercepted at ports.
5.A Personalized Brain-computer Interface Paradigm and Decoding Method for The Objective Evaluation of Auditory Frequency Difference Limen
Sheng-Ye LI ; Xiao-Lin XIAO ; Shi-Hang YU ; Bei-Bei ZHANG ; Xing-Wei AN ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2026;53(7):1927-1941
ObjectiveThe frequency difference limen (FDL) serves as a fundamental metric utilized for effectively quantifying the precise perceptual capabilities of the central auditory system. However, traditional measurement methods rely heavily on the active behavioral responses of subjects and are consequently highly susceptible to the negative influence of confounding subjective factors. Furthermore, existing research paradigms frequently employ uniform stimulus configurations that overlook critical individual perceptual differences. Based on brain-computer interface (BCI) technology, this comprehensive study aims to establish an objective and quantitative evaluation method for auditory frequency discrimination by systematically analyzing and decoding the specific neural responses elicited at the exact threshold state. MethodsWe designed a personalized rapid serial auditory presentation (RSAP) paradigm customized based on each individual’s precise FDL. A cohort of eleven healthy participants was recruited to evaluate the paradigm using pure-tone sequences at a baseline frequency of 4 000 Hz. This experimental paradigm simulates a realistic auditory perception environment through the continuous presentation of acoustic stimuli, thereby allowing for an in-depth investigation into the specific neural representations evoked by weak frequency deviations at the threshold state. Given that auditory stimulus-evoked response features exhibit complex and differentiated spatiotemporal distribution patterns across multiple frequency domains, this study further deeply integrates the cross-scale feature interaction module with the dynamic spatiotemporal attention allocation strategy, innovatively proposing the Multi-Scale Spatial-Temporal Dual Attention Network (MS-STAMNet). Specifically, the network constructs parallel processing branches with multiple receptive fields and introduces a dynamic adaptive weighting strategy to precisely localize core neural activity signals, further deeply integrating multi-scale information through cross-branch feature information interaction to achieve robust single-trial decoding of weak auditory evoked responses. ResultsThe comprehensive electrophysiological data analysis demonstrated that subtle auditory frequency deviation stimuli presented at the threshold level successfully elicited pronounced N2 and P3 event-related potential features, reflecting pre-attentive mismatch detection and subsequent cognitive evaluation, which were prominently distributed over the frontal, central, and temporal regions of the scalp. In the complex time-frequency domain, the extracted neural response characteristics exhibited distinct, statistically significant event-related synchronization within both the low-frequency δ and θ frequency bands, which was simultaneously accompanied by a widespread, prominent event-related desynchronization within the higher α band. A comparative analysis of model performance demonstrated that MS-STAMNet achieved an average unweighted average recall (UAR) of (69.67±6.12)% and area under the curve (AUC) of 0.761 8±0.07, significantly outperforming the established baseline models such as EEGNet and PLNet. Furthermore, a distinct dissociation phenomenon was verified between neural decoding and behavioral performance through regression analysis (R2=0.016, P=0.709), indicating that this model can effectively capture the implicit features of subtle frequency deviations, even when they fail to trigger explicit conscious responses. Additionally, attention weight visualization analysis further reveals the highly accurate focus of the network on key features concentrated over the bilateral temporal and fronto-parietal regions. ConclusionThis study systematically and comprehensively uncovers the multi-dimensional spatiotemporal evolutionary patterns of complex neural responses processing subtle acoustic variations under long-sequence threshold auditory stimulation. Concurrently, it verifies the efficacy and robustness of the proposed MS-STAMNet architecture in accurately deciphering weak, single-trial electroencephalogram signals amidst complex background noise. Ultimately, these neurophysiological and algorithmic findings lay a solid theoretical and methodological foundation for the objective and quantitative evaluation of individual auditory cognitive capabilities in clinical applications, transcending the fundamental limitations of traditional behavioral paradigms and providing robust technical support for future auditory research and related clinical assessments.
6.Technique and Application of Deep Learning-based EEG Denoising
Bao-Lian SHAN ; Hai-Qing YU ; Yong-Zhi HUANG ; Jia-Yuan MENG ; Min-Peng XU ; Tzyy-Ping JUNG ; Dong MING
Progress in Biochemistry and Biophysics 2026;53(8):2147-2160
Electroencephalography (EEG) is a non-invasive neurophysiological monitoring technique. It records the electrical activity of the cerebral cortex using electrodes placed on the scalp surface. Owing to its high safety, portability, and millisecond-level temporal resolution, EEG has been widely utilized in a variety of fields, including clinical diagnosis, brain-computer interfaces (BCIs), and cognitive neuroscience research. However, due to its microvolt-level amplitude, EEG is highly susceptible to various artifacts, including electrooculographic (EOG), electrocardiographic (ECG), electromyographic (EMG), and power line interference (PLI). These artifacts can obscure genuine neural activity and introduce spurious electrophysiological features. Consequently, they may compromise EEG signal quality, thereby reducing the reliability of downstream analyses. To address this issue, numerous EEG artifact removal methods have been developed, including both traditional denoising techniques and deep learning-based approaches. Traditional EEG denoising methods have long served as the primary solutions for artifact removal. Representative approaches include filtering, regression, and blind source separation. Although these methods have demonstrated effectiveness in specific scenarios, they suffer from several inherent limitations. Filtering assumes that artifacts and EEG signals can be separated in the frequency domain, but many artifacts, such as EOG and EMG, overlap with EEG spectra, which may lead to the loss of valuable neural information. Regression methods require high-quality artifact references to estimate and subtract contaminations, limiting their effectiveness in reference-free scenarios. Blind source separation can remove artifacts without external references, but it typically requires the number of EEG channels to exceed the number of sources, restricting its application in single- or low-channel EEG recordings. Deep learning-based EEG denoising methods address these limitations effectively. First, they learn the nonlinear mapping between contaminated and clean EEG directly from data in an end-to-end manner. This approach does not rely on assumptions about spectral separability, thereby preserving neural activity more completely. Second, the reference information is incorporated during the training phase, allowing the trained model to perform artifact removal independently without external references. Third, deep learning models can be flexibly designed to accommodate various recording setups, achieving robust denoising for both high-density and single-channel EEG. Collectively, these advantages enable deep learning-based methods to overcome the main challenges of traditional approaches, providing more accurate and reliable EEG signal recovery. The superior denoising performance of deep learning-based EEG denoising methods has attracted increasing attention in EEG artifact removal research. As a result, many deep learning-based denoising methods have been developed and successfully applied in neural engineering areas. However, a systematic review of the techniques and applications in this field is still lacking. To address this gap, this paper reviews recent advances in deep learning-based EEG denoising from four perspectives: technical principle, benchmark dataset, denoising model, and evaluation method. Representative applications in neural signal analysis and BCI decoding are also summarized. Furthermore, the advantage, existing challenge, and future research direction of deep learning-based EEG denoising are discussed. This review aims to provide valuable theoretical insights and technical guidance for researchers. It is also expected to promote further advances and broader applications of deep learning-based EEG denoising techniques.
7.Research and Application of Scalp Surface Laplacian Technique
Rui-Xin LUO ; Si-Ying GUO ; Xin-Yi LI ; Yu-He ZHAO ; Chun-Hou ZHENG ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(2):425-438
Electroencephalogram (EEG) is a non-invasive, high temporal-resolution technique for monitoring brain activity. However, affected by the volume conduction effect, EEG has a low spatial resolution and is difficult to locate brain neuronal activity precisely. The surface Laplacian (SL) technique obtains the Laplacian EEG (LEEG) by estimating the second-order spatial derivative of the scalp potential. LEEG can reflect the radial current activity under the scalp, with positive values indicating current flow from the brain to the scalp (“source”) and negative values indicating current flow from the scalp to the brain (“sink”). It attenuates signals from volume conduction, effectively improving the spatial resolution of EEG, and is expected to contribute to breakthroughs in neural engineering. This paper provides a systematic overview of the principles and development of SL technology. Currently, there are two implementation paths for SL technology: current source density algorithms (CSD) and concentric ring electrodes (CRE). CSD performs the Laplace transform of the EEG signals acquired by conventional disc electrodes to indirectly estimate the LEEG. It can be mainly classified into local methods, global methods, and realistic Laplacian methods. The global method is the most commonly used approach in CSD, which can achieve more accurate estimation compared with the local method, and it does not require additional imaging equipment compared with the realistic Laplacian method. CRE employs new concentric ring electrodes instead of the traditional disc electrodes, and measures the LEEG directly by differential acquisition of the multi-ring signals. Depending on the structure, it can be divided into bipolar CRE, quasi-bipolar CRE, tripolar CRE, and multi-pole CRE. The tripolar CRE is widely used due to its optimal detection performance. While ensuring the quality of signal acquisition, the complexity of its preamplifier is relatively acceptable. Here, this paper introduces the study of the SL technique in resting rhythms, visual-related potentials, movement-related potentials, and sensorimotor rhythms. These studies demonstrate that SL technology can improve signal quality and enhance signal characteristics, confirming its potential applications in neuroscientific research, disease diagnosis, visual pathway detection, and brain-computer interfaces. CSD is frequently utilized in applications such as neuroscientific research and disease detection, where high-precision estimation of LEEG is required. And CRE tends to be used in brain-computer interfaces, that have stringent requirements for real-time data processing. Finally, this paper summarizes the strengths and weaknesses of SL technology and envisages its future development. SL technology boasts advantages such as reference independence, high spatial resolution, high temporal resolution, enhanced source connectivity analysis, and noise suppression. However, it also has shortcomings that can be further improved. Theoretically, simulation experiments should be conducted to investigate the theoretical characteristics of SL technology. For CSD methods, the algorithm needs to be optimized to improve the precision of LEEG estimation, reduce dependence on the number of channels, and decrease computational complexity and time consumption. For CRE methods, the electrodes need to be designed with appropriate structures and sizes, and the low-noise, high common-mode rejection ratio preamplifier should be developed. We hope that this paper can promote the in-depth research and wide application of SL technology.
8.Predicting Clinically Significant Prostate Cancer Using Urine Metabolomics via Liquid Chromatography Mass Spectrometry
Chung-Hsin CHEN ; Hsiang-Po HUANG ; Kai-Hsiung CHANG ; Ming-Shyue LEE ; Cheng-Fan LEE ; Chih-Yu LIN ; Yuan Chi LIN ; William J. HUANG ; Chun-Hou LIAO ; Chih-Chin YU ; Shiu-Dong CHUNG ; Yao-Chou TSAI ; Chia-Chang WU ; Chen-Hsun HO ; Pei-Wen HSIAO ; Yeong-Shiau PU ;
The World Journal of Men's Health 2025;43(2):376-386
Purpose:
Biomarkers predicting clinically significant prostate cancer (sPC) before biopsy are currently lacking. This study aimed to develop a non-invasive urine test to predict sPC in at-risk men using urinary metabolomic profiles.
Materials and Methods:
Urine samples from 934 at-risk subjects and 268 treatment-naïve PC patients were subjected to liquid chromatography/mass spectrophotometry (LC-MS)-based metabolomics profiling using both C18 and hydrophilic interaction liquid chromatography (HILIC) column analyses. Four models were constructed (training cohort [n=647]) and validated (validation cohort [n=344]) for different purposes. Model I differentiates PC from benign cases. Models II, III, and a Gleason score model (model GS) predict sPC that is defined as National Comprehensive Cancer Network (NCCN)-categorized favorable-intermediate risk group or higher (Model II), unfavorable-intermediate risk group or higher (Model III), and GS ≥7 PC (model GS), respectively. The metabolomic panels and predicting models were constructed using logistic regression and Akaike information criterion.
Results:
The best metabolomic panels from the HILIC column include 25, 27, 28 and 26 metabolites in Models I, II, III, and GS, respectively, with area under the curve (AUC) values ranging between 0.82 and 0.91 in the training cohort and between 0.77 and 0.86 in the validation cohort. The combination of the metabolomic panels and five baseline clinical factors that include serum prostate-specific antigen, age, family history of PC, previously negative biopsy, and abnormal digital rectal examination results significantly increased AUCs (range 0.88–0.91). At 90% sensitivity (validation cohort), 33%, 34%, 41%, and 36% of unnecessary biopsies were avoided in Models I, II, III, and GS, respectively. The above results were successfully validated using LC-MS with the C18 column.
Conclusions
Urinary metabolomic profiles with baseline clinical factors may accurately predict sPC in men with elevated risk before biopsy.
9.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
10.Research progress on the application of visual electrophysiological examination in early diagnosis of glaucoma
Chang SUN ; Rong ZHANG ; Xiaolin XIAO ; Minpeng XU ; Dong MING ; Xia HUA
International Eye Science 2025;25(7):1073-1078
Glaucoma is a group of optic nerve disorders characterized by progressive optic nerve atrophy and visual field defects, which can lead to irreversible blindness. Early diagnosis of glaucoma is essential for preventing visual loss. However, due to the absence of obvious early symptoms, the diagnosis of glaucoma remains challenging. Visual electrophysiological examinations, an objective approach for evaluating visual function, have the potential to be used in the early diagnosis of glaucoma. This review integrates the latest publications to introduce visual electrophysiological examination techniques, including electroretinography(ERG)and visual evoked potential(VEP). It also explores the mechanisms underlying these techniques and their application value in the early diagnosis of glaucoma. In addition, this review summarizes the advantages, limitations, and applicable scenarios of different visual electrophysiological techniques. Finally, the review provides an outlook on the development prospects of visual electrophysiological techniques in the early diagnosis of glaucoma. The findings of this review can assist clinicians in selecting appropriate diagnostic methods, promote the innovation and development of early visual electrophysiological diagnostic techniques for glaucoma, and contribute to reducing the risk of blindness caused by glaucoma.


Result Analysis
Print
Save
E-mail