1.Artificial intelligence-based quality control of hand hygiene for hospital-acquired infection
Xuchen YANG ; Jingwen LI ; Wan ZHANG ; Shasha FENG ; Min ZENG ; Jianan SHI ; Youqiong CHEN ; Tao ZHENG ; Xun YAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(02):241-247
Objective To explore an artificial intelligence (AI)-based method for automated hand hygiene monitoring and to compare the effectiveness of three algorithms (UniFormerV2, TDN, C3D) in recognizing hand hygiene steps in surgical settings, thereby aiding hospital infection control. Methods From April to October 2024, we non-invasively collected 641 video recordings of healthcare staff performing hand hygiene at four-bay scrub sinks in two tertiary hospitals using overhead HD cameras. The dataset was annotated by five trained experts for model training and validation. Results Following training on 385 samples, internal validation (n=119) showed the C3D model achieved 81% accuracy, 87% recall, and an 83% F1-score. The TDN model achieved 93%, 91%, and 92% for the same metrics. The UniFormerV2 model outperformed both, with an accuracy, recall, and F1-score of 93%—an improvement of over 10 percentage points compared to traditional CNNs (TDN, C3D). It also achieved an 84% accuracy in external validation, demonstrating strong generalization. Conclusion The UniFormerV2 model is more accurate than CNN-based models for hand hygiene step recognition and shows robust performance in external validation. It presents a viable tool for healthcare facilities to enhance hand hygiene management, ultimately improving medical quality and patient safety.
2.Comparative analyses of the detection performance of five multiplex polymerase chain reaction nucleic acid detection kits for respiratory pathogens
Fang YUAN ; Lei BI ; Jiajing LIU ; Huanru WANG ; Jun FENG ; Yuan ZHUANG ; Min CHEN ; Zheng TENG
Shanghai Journal of Preventive Medicine 2026;38(2):165-169
ObjectiveTo evaluate the detection specificity for clinical samples and the detection capability for standard substances of five commercially available multiplex polymerase chain reaction (PCR) nucleic acid detection kits (hereinafter referred to as the kits) for respiratory pathogens, and to provide a reference for selecting appropriate detection kits for multi-pathogen nucleic acid testing of respiratory infections. MethodsA total of 60 respiratory pathogen-positive clinical samples with known redults were selected and tested using the five kits (labeled as A, B, C, D, and E). The detection rates and Kappa coefficients were calculated to evaluate the consistency between the results from these kits and those from single-pathogen PCR kits. According to the limit of detection (LOD) provided by the kits, standard substances of respiratory pathogens (including 12 types such as influenza virus, Mycoplasma pneumoniae, and Bordetella pertussis) were diluted to four concentrations (250, 500, 1 000, and 2 000 copies·mL⁻¹). All five kits were used for detection to evaluate their respective detection capabilities. ResultsCompared with the results from single-pathogen PCR kits, the five tested kits demonstrated good consistency (all Kappa >0.80). Among them, Kit A had the highest detection rate (100.00%), followed by Kits C and E (98.33%), and then Kits B and D (95.00%). All five kits showed a relatively low false negative rate (FNR) for samples with a cycle threshold (Ct) value ≤35 (≤2.38%). However, for samples with Ct values>35, the FNR increased accordingly(average FNR=6.67%, P=0.029). Kit C exhibited the highest detection sensitivity for the tested standard substances (average LOD: 458.33 copies·mL⁻¹), followed by Kit D, then Kits A/E, and finally Kit B. ConclusionThe five multiplex PCR kits showed good consistency with single-pathogen detection results, but each had its own performance emphasis. Kit A, with the highest detection rate and high throughput, is suitable for targeted viral screening. Kit B, covering the broadest pathogen spectrum (including fungi/bacteria), is suitable for comprehensive respiratory pathogen screening. Kits C, D and E, are applicable for rapid detection. It is important to note that the detection efficacy of all kits decreases for low viral load samples with Ct values >35. In practical application, selection should be based on specific screening objectives, throughput requirements, and sample types.
3.Controlled hypotension under rapid ventricular pacing technique in patients with cerebral arteriovenous malformation -a case report-
Zijian ZHAO ; Hang WANG ; Xinxu MIN ; Zheng LI ; Feng FENG
Korean Journal of Anesthesiology 2025;78(1):79-84
Background:
The transvenous approach to the treatment of cerebral arteriovenous malformation (AVM) is difficult and requires strict blood pressure and blood flow control; however, the cure rate is very high. Appropriate blood pressure control techniques can greatly benefit these patients.Case: A 55-year-old male patient was found to have an aneurysm complicated with a cerebral AVM (length: 2.0 cm, width: 1.6 cm, height: 1.2 cm). Aneurysm embolization was considered for the first-stage surgery and transvenous AVM embolization for the second-stage surgery. Rapid ventricular pacing (RVP) provided a stable blood flow environment for the surgery, which was completed successfully.
Conclusion
RVP can thus provide an ideal condition for the embolization of cerebral AVM through the transvenous approach and can be a viable surgical option.
4.Interpretation of the CONSORT 2025 statement: Updated guideline for reporting randomized trials
Geliang YANG ; Xiaoqin ZHOU ; Fang LEI ; Min DONG ; Tianxing FENG ; Li ZHENG ; Lunxu LIU ; Yunpeng ZHU ; Xuemei LIU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(06):752-759
The Consolidated Standards of Reporting Trials (CONSORT) statement aims to enhance the quality of reporting for randomized controlled trial (RCT) by providing a minimum item checklist. It was first published in 1996, and updated in 2001 and 2010, respectively. The latest version was released in April 2025, continuously reflecting new evidence, methodological advancements, and user feedback. CONSORT 2025 includes 30 essential checklist items and a template for a participant flow diagram. The main changes to the checklist include the addition of 7 items, revision of 3 items, and deletion of 1 item, as well as the integration of multiple key extensions. This article provides a comprehensive interpretation of the statement, aiming to help clinical trial staff, journal editors, and reviewers fully understand the essence of CONSORT 2025, correctly apply it in writing RCT reports and evaluating RCT quality, and provide guidance for conducting high-level RCT research in China.
5.NUMB endocytic adaptor protein (NUMB) mediates the anti-hepatic fibrosis effect of artesunate (ART) by inducing senescence in hepatic stellate cells (HSCs).
Yangling QIU ; Yujia LI ; Mengran LI ; Yingqian WANG ; Min SHEN ; Jiangjuan SHAO ; Feng ZHANG ; Xuefen XU ; Feixia WANG ; Zili ZHANG ; Shizhong ZHENG
Chinese Journal of Natural Medicines (English Ed.) 2025;23(3):322-333
Developing and identifying effective medications and targets for treating hepatic fibrosis is an urgent priority. Our previous research demonstrated the efficacy of artesunate (ART) in alleviating liver fibrosis by eliminating activated hepatic stellate cells (HSCs). However, the underlying mechanism remains unclear despite these findings. Notably, endocytic adaptor protein (NUMB) has significant implications for treating hepatic diseases, but current research primarily focuses on liver regeneration and hepatocellular carcinoma. The precise function of NUMB in liver fibrosis, particularly its ability to regulate HSCs, requires further investigation. This study aims to elucidate the role of NUMB in the anti-hepatic fibrosis action of ART in HSCs. We observed that the expression level of NUMB significantly decreased in activated HSCs compared to quiescent HSCs, exhibiting a negative correlation with the progression of liver fibrosis. Additionally, ART induced senescence in activated HSCs through the NUMB/P53 tumor suppressor (P53) axis. We identified NUMB as a crucial regulator of senescence in activated HSCs and as a mediator of ART in determining cell fate. This research examines the specific target of ART in eliminating activated HSCs, providing both theoretical and experimental evidence for the treatment of liver fibrosis.
Hepatic Stellate Cells/cytology*
;
Liver Cirrhosis/genetics*
;
Artesunate/pharmacology*
;
Cellular Senescence/drug effects*
;
Membrane Proteins/genetics*
;
Animals
;
Humans
;
Nerve Tissue Proteins/genetics*
;
Tumor Suppressor Protein p53/genetics*
;
Male
;
Mice
6.Controlled hypotension under rapid ventricular pacing technique in patients with cerebral arteriovenous malformation -a case report-
Zijian ZHAO ; Hang WANG ; Xinxu MIN ; Zheng LI ; Feng FENG
Korean Journal of Anesthesiology 2025;78(1):79-84
Background:
The transvenous approach to the treatment of cerebral arteriovenous malformation (AVM) is difficult and requires strict blood pressure and blood flow control; however, the cure rate is very high. Appropriate blood pressure control techniques can greatly benefit these patients.Case: A 55-year-old male patient was found to have an aneurysm complicated with a cerebral AVM (length: 2.0 cm, width: 1.6 cm, height: 1.2 cm). Aneurysm embolization was considered for the first-stage surgery and transvenous AVM embolization for the second-stage surgery. Rapid ventricular pacing (RVP) provided a stable blood flow environment for the surgery, which was completed successfully.
Conclusion
RVP can thus provide an ideal condition for the embolization of cerebral AVM through the transvenous approach and can be a viable surgical option.
7.Controlled hypotension under rapid ventricular pacing technique in patients with cerebral arteriovenous malformation -a case report-
Zijian ZHAO ; Hang WANG ; Xinxu MIN ; Zheng LI ; Feng FENG
Korean Journal of Anesthesiology 2025;78(1):79-84
Background:
The transvenous approach to the treatment of cerebral arteriovenous malformation (AVM) is difficult and requires strict blood pressure and blood flow control; however, the cure rate is very high. Appropriate blood pressure control techniques can greatly benefit these patients.Case: A 55-year-old male patient was found to have an aneurysm complicated with a cerebral AVM (length: 2.0 cm, width: 1.6 cm, height: 1.2 cm). Aneurysm embolization was considered for the first-stage surgery and transvenous AVM embolization for the second-stage surgery. Rapid ventricular pacing (RVP) provided a stable blood flow environment for the surgery, which was completed successfully.
Conclusion
RVP can thus provide an ideal condition for the embolization of cerebral AVM through the transvenous approach and can be a viable surgical option.
8.Assessment for the best evidence of preventing fire accident in electrical surgery of operation room
Li LI ; Yuan HU ; Wenjuan MA ; Likun LUO ; Min FENG ; Shuangfeng ZHENG
China Medical Equipment 2025;22(10):120-127
Objective:To search,evaluate and integrate the best evidence of preventing fire accident in electrical surgery of domestic and international operating room,so as to provide reference for clinical practice of equipment in electrical surgery of operating room.Methods:This study conducted a literature review for domestically and internationally support systems of clinical decision,guideline websites,websites of nursing professional association,and Chinese-English databases.A series of relative literatures of fire accident in electrical surgery of operating room were included,which focused on clinical decisions,guidelines,evidence summaries,systematic evaluations,and expert consensus.The search period covered from the establishment date of database to November 12,2024,and the included literatures only limited to be English and Chinese publications.Two researchers who received evidence-based training independently evaluated the quality of these literatures,and they extracted and integrated information meeting quality standards according to professional judgment.Results:A total of 4,807 literatures were obtained after preliminary search.Then,a total of 12 research literatures were included,including 1 clinical decision,4 guidelines,1 evidence summary,3 systematic reviews and 3 expert consensus.The 20 best evidences of preventing fire accident in electrical surgery of operating room were summarized from three aspects:risk factors,risk assessment and preventive measures.Conclusion:The best evidence of preventing fire accident in electrical surgery of operating room can provide evidence-based evidences for the standardized management for electrical surgery of operation room,and provide basis for formulating management plan of preventing fire accident in electrical surgery of operation room,and for standardizing practice behavior of medical staffs.The evidence transformation should combined with actual clinical situation,and should reasonably select and prudently apply evidences.
9.Controlled hypotension under rapid ventricular pacing technique in patients with cerebral arteriovenous malformation -a case report-
Zijian ZHAO ; Hang WANG ; Xinxu MIN ; Zheng LI ; Feng FENG
Korean Journal of Anesthesiology 2025;78(1):79-84
Background:
The transvenous approach to the treatment of cerebral arteriovenous malformation (AVM) is difficult and requires strict blood pressure and blood flow control; however, the cure rate is very high. Appropriate blood pressure control techniques can greatly benefit these patients.Case: A 55-year-old male patient was found to have an aneurysm complicated with a cerebral AVM (length: 2.0 cm, width: 1.6 cm, height: 1.2 cm). Aneurysm embolization was considered for the first-stage surgery and transvenous AVM embolization for the second-stage surgery. Rapid ventricular pacing (RVP) provided a stable blood flow environment for the surgery, which was completed successfully.
Conclusion
RVP can thus provide an ideal condition for the embolization of cerebral AVM through the transvenous approach and can be a viable surgical option.
10.Diagnostic value of electromyographic tremor indicators for Parkinson's disease based on Logistic regression model
Zeng ZHOU ; Jing XU ; Zhaohai FENG ; Yingwei ZHENG ; Min CUI ; Zongyu WANG ; Fang FANG ; Meiying LI
Journal of Clinical Medicine in Practice 2025;29(1):33-38
Objective To investigate the diagnostic value of electromyographic(EMG)tremor indicators for Parkinson's disease(PD)using the Logistic regression model.Methods A total of 65 patients with PD(PD group)and 39 patients with essential tremor(ET)(ET group)were enrolled and underwent EMG tremor analysis.General information,disease-related data,and EMG tremor characteristics were compared between the two groups.Multivariate Logistic regression analysis was performed to screen for independent influencing factors of PD,and receiver operating characteristic(ROC)curves were plotted.The area under the curve(AUC)was used to evaluate the diagnostic value of EMG tremor indicators for PD.Results Compared with the ET group,the PD group had a higher proportion of patients with unilateral onset and those with tremor spectrum frequency≥2 times,and a lower proportion of patients with a family history of tremor(P<0.05).The tremor peak frequencies in the resting,postural,and weight-bearing(1 000 g)states were lower in the PD group than in the ET group(P<0.05).There were statistically significant differences in the tremor rhythm patterns between the two groups in the resting and weight-bearing states(P<0.05),with the PD group dominated by alternating contraction patterns and the ET group by synchronous contraction pat-terns.Multivariate Logistic regression analysis revealed that the tremor peak frequency in the weight-bearing state,the tremor rhythm pattern in the resting state,and the frequency of tremor spectrum were independent influencing factors of PD(P<0.05).The ROC curves showed that the AUCs of the tremor peak frequency in the weight-bearing state,the tremor rhythm pattern in the resting state,and the frequency of tremor spectrum for diagnosing PD were 0.886,0.750,and 0.779,respec-tively.The combination of these three indicators yielded the highest AUC(0.936)for diagnosing PD,with a sensitivity of 81.54%and a specificity of 94.87%.Conclusion The tremor peak fre-quency in the weight-bearing state,the tremor rhythm pattern in the resting state,and the frequency of tremor spectrum provided by EMG tremor analysis can serve as clinical indicators for early diagno-sis of PD,and their combined use offers higher diagnostic value,which can be used to differentiate PD from ET.

Result Analysis
Print
Save
E-mail