1.Reinjection in Patients with Intraocular Inflammation Development after Intravitreal Brolucizumab Injection
Myung Ae KIM ; Soon Il CHOI ; Jong Min KIM ; Hyun Sub OH ; Yong Sung YOU ; Won Ki LEE ; Soon Hyun KIM ; Oh Woong KWON ; Ju Young KIM
Korean Journal of Ophthalmology 2025;39(3):213-221
Purpose:
To investigate the outcomes of brolucizumab reinjection after intraocular inflammation (IOI) development.
Methods:
This retrospective study analyzed patients with brolucizumab injections from April 2021 to January 2024. Patients who developed IOI after brolucizumab were included and categorized into subgroups depending on reinjection, discontinuation, and further IOI development.
Results:
A total of 472 eyes of 432 patients received brolucizumab injections. Thirty-eight cases developed IOI at least once, and 25 continued brolucizumab. Sixteen cases had no more IOI events, and nine experienced a second or more IOI events. Among the nine cases, three maintained brolucizumab injections despite IOI recurrence. The incidence of IOI was 8.1% based on the number of eyes (38 of 472 eyes) and 2.0% based on the number of brolucizumab injections (50 of 2,468 injections). The incidence of occlusive retinal vasculitis was 0.2% (1 of 472 eyes). The recurrence rate was 23.7% (9 of 38 eyes). The average number of injections between the first brolucizumab injection and the injection date on which IOI first developed was 2.15 times in the no-reinjection group, 3.44 times in the no-IOI-recurrence group, and 2.0 times in the second-IOI-episode group. Time to IOI occurrence in cases with first IOI episode was 18.60 ± 16.73 days, with 15 cases developing IOI within 1 week.
Conclusions
This study elucidates the real-world incidence of brolucizumab associated IOIs, with a description of information related to reinjections after the IOI episodes. A comprehensive understanding of brolucizumab reinjection is essential for its optimal utilization.
2.Two Cases of Pancreatobiliary Disease Complications Treated Using Over-the-Scope Clip
Byung Soo KWAN ; Bo Ram SUNG ; Kwang Min KIM
Korean Journal of Pancreas and Biliary Tract 2025;30(1):26-30
The over-the-scope clip (OTSC) system is a powerful full-thickness suturing device used for closing refractory bleeding, perforations, and fistulas in gastrointestinal diseases, offering greater force than conventional clips. Here, we report two cases of pancreatobiliary disease treated using OTSC. The first case involved the successful OTSC ligation of a colonic fistula caused by necrotizing pancreatitis, and the second was a duodenal perforation due to stent migration, which was also successfully treated with OTSC. These cases indicate that OTSC can be beneficial for pancreatobiliary diseases, potentially eliminating the need for surgery when endoscopic treatment is successful.
3.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
4.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
5.Differences in Treatment Outcomes Depending on the Adjuvant Treatment Modality in Craniopharyngioma
Byung Min LEE ; Jaeho CHO ; Dong-Seok KIM ; Jong Hee CHANG ; Seok-Gu KANG ; Eui-Hyun KIM ; Ju Hyung MOON ; Sung Soo AHN ; Yae Won PARK ; Chang-Ok SUH ; Hong In YOON
Yonsei Medical Journal 2025;66(3):141-150
Purpose:
Adjuvant treatment for craniopharyngioma after surgery is controversial. Adjuvant external beam radiation therapy (EBRT) can increase the risk of long-term sequelae. Stereotactic radiosurgery (SRS) is used to reduce treatment-related toxicity.In this study, we compared the treatment outcomes and toxicities of adjuvant therapies for craniopharyngioma.
Materials and Methods:
We analyzed patients who underwent craniopharyngioma tumor removal between 2000 and 2017. Of the 153 patients, 27 and 20 received adjuvant fractionated EBRT and SRS, respectively. We compared the local control (LC), progression-free survival (PFS), and overall survival between groups that received adjuvant fractionated EBRT, SRS, and surveillance.
Results:
The median follow-up period was 77.7 months. For SRS and surveillance, the 10-year LC was 57.2% and 57.4%, respectively. No local progression was observed after adjuvant fractionated EBRT. One patient in the adjuvant fractionated EBRT group died owing to glioma 94 months after receiving radiotherapy (10-year PFS: 80%). The 10-year PFS was 43.6% and 50.7% in the SRS and surveillance groups, respectively. The treatment outcomes significantly differed according to adjuvant treatment in nongross total resection (GTR) patients. Additional treatment-related toxicity was comparable in the adjuvant fractionated EBRT and other groups.
Conclusion
Adjuvant fractionated EBRT could be effective in controlling local failure, especially in patients with non-GTR, while maintaining acceptable treatment-related toxicity.
6.Risk Factors for Failure to Eradicate Infection after Single Arthroscopic Debridement in Septic Arthritis of a Native Knee Joint
Junwoo BYUN ; Min JUNG ; Kwangho CHUNG ; Se-Han JUNG ; Hyeokjoo JANG ; Chong-Hyuk CHOI ; Sung-Hwan KIM
Yonsei Medical Journal 2025;66(5):295-301
Purpose:
To identify the risk factors and effect of empirical glycopeptide on the failure of single arthroscopic debridement for septic knee arthritis in a native knee joint.
Materials and Methods:
Patients who underwent arthroscopic debridement for septic knee arthritis from March 2005 to December 2022 at one institution were included in this study. Demographic data, comorbidities, preoperative factors including history of previous surgery, history of injection, laboratory data including preoperative C-reactive protein (CRP) and white blood cell (WBC) count, isolated pathogens from synovial fluid culture, and Gachter stage were analyzed. Statistical analyses using univariate and logistic regression were performed.
Results:
Out of 132 patients, 17 patients (12.9%) had more than one additional arthroscopic debridement. History of diabetes mellitus (DM) (p<0.001), previous injection (p=0.041), isolated Staphylococcus aureus in synovial fluid (p=0.010), and high Gachter stage (p=0.002) were identified as risk factors, whereas age, history of previous knee surgery at the affected knee, CRP level, preoperative WBC, and preoperative neutrophil count of synovial fluid had no significant relation. Logistic regression analysis showed significant increase of risk in patients with DM [odds ratio (OR) 12.002, 95% confidence interval (CI) 3.243–44.418, p<0.001], previous injection history (OR 4.812, 95% CI 1.367–16.939, p=0.017), and isolation of Staphylococcus aureus in synovial fluid (OR 4.804, 95% CI 1.282–18.001, p=0.031) as independent risk factors for failure of infection eradication after single arthroscopic debridement.
Conclusion
Comorbidity of DM, history of previous injection, isolated Staphylococcus aureus in synovial fluid, and high Gachter stage were associated with a higher risk of failure to eradicate infection with a single arthroscopic procedure. Empirical glycopeptide administration also showed no significant benefit in reducing the risk of additional surgical procedures for infection control, suggesting against the routine administration of glycopeptide.
7.Reinjection in Patients with Intraocular Inflammation Development after Intravitreal Brolucizumab Injection
Myung Ae KIM ; Soon Il CHOI ; Jong Min KIM ; Hyun Sub OH ; Yong Sung YOU ; Won Ki LEE ; Soon Hyun KIM ; Oh Woong KWON ; Ju Young KIM
Korean Journal of Ophthalmology 2025;39(3):213-221
Purpose:
To investigate the outcomes of brolucizumab reinjection after intraocular inflammation (IOI) development.
Methods:
This retrospective study analyzed patients with brolucizumab injections from April 2021 to January 2024. Patients who developed IOI after brolucizumab were included and categorized into subgroups depending on reinjection, discontinuation, and further IOI development.
Results:
A total of 472 eyes of 432 patients received brolucizumab injections. Thirty-eight cases developed IOI at least once, and 25 continued brolucizumab. Sixteen cases had no more IOI events, and nine experienced a second or more IOI events. Among the nine cases, three maintained brolucizumab injections despite IOI recurrence. The incidence of IOI was 8.1% based on the number of eyes (38 of 472 eyes) and 2.0% based on the number of brolucizumab injections (50 of 2,468 injections). The incidence of occlusive retinal vasculitis was 0.2% (1 of 472 eyes). The recurrence rate was 23.7% (9 of 38 eyes). The average number of injections between the first brolucizumab injection and the injection date on which IOI first developed was 2.15 times in the no-reinjection group, 3.44 times in the no-IOI-recurrence group, and 2.0 times in the second-IOI-episode group. Time to IOI occurrence in cases with first IOI episode was 18.60 ± 16.73 days, with 15 cases developing IOI within 1 week.
Conclusions
This study elucidates the real-world incidence of brolucizumab associated IOIs, with a description of information related to reinjections after the IOI episodes. A comprehensive understanding of brolucizumab reinjection is essential for its optimal utilization.
8.Two Cases of Pancreatobiliary Disease Complications Treated Using Over-the-Scope Clip
Byung Soo KWAN ; Bo Ram SUNG ; Kwang Min KIM
Korean Journal of Pancreas and Biliary Tract 2025;30(1):26-30
The over-the-scope clip (OTSC) system is a powerful full-thickness suturing device used for closing refractory bleeding, perforations, and fistulas in gastrointestinal diseases, offering greater force than conventional clips. Here, we report two cases of pancreatobiliary disease treated using OTSC. The first case involved the successful OTSC ligation of a colonic fistula caused by necrotizing pancreatitis, and the second was a duodenal perforation due to stent migration, which was also successfully treated with OTSC. These cases indicate that OTSC can be beneficial for pancreatobiliary diseases, potentially eliminating the need for surgery when endoscopic treatment is successful.
9.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
10.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.

Result Analysis
Print
Save
E-mail