1.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
2.Development of a Standardized Suicide Prevention Program for Gatekeeper Intervention in Korea (Suicide CARE Version 2.0) to Prevent Adolescent Suicide: Version for Teachers
Hyeon-Ah LEE ; Yeon Jung LEE ; Kyong Ah KIM ; Myungjae BAIK ; Jong-Woo PAIK ; Jinmi SEOL ; Sang Min LEE ; Eun-Jin LEE ; Haewoo LEE ; Meerae LIM ; Jin Yong JUN ; Seon Wan KI ; Hong Jin JEON ; Sun Jung KWON ; Hwa-Young LEE
Psychiatry Investigation 2025;22(1):117-117
3.Development of a Standardized Suicide Prevention Program for Gatekeeper Intervention in Korea (Suicide CARE Version 2.0) to Prevent Adolescent Suicide: Version for Teachers
Hyeon-Ah LEE ; Yeon Jung LEE ; Kyong Ah KIM ; Myungjae BAIK ; Jong-Woo PAIK ; Jinmi SEOL ; Sang Min LEE ; Eun-Jin LEE ; Haewoo LEE ; Meerae LIM ; Jin Yong JUN ; Seon Wan KI ; Hong Jin JEON ; Sun Jung KWON ; Hwa-Young LEE
Psychiatry Investigation 2025;22(1):117-117
4.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
5.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
6.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
7.Development of a Standardized Suicide Prevention Program for Gatekeeper Intervention in Korea (Suicide CARE Version 2.0) to Prevent Adolescent Suicide: Version for Teachers
Hyeon-Ah LEE ; Yeon Jung LEE ; Kyong Ah KIM ; Myungjae BAIK ; Jong-Woo PAIK ; Jinmi SEOL ; Sang Min LEE ; Eun-Jin LEE ; Haewoo LEE ; Meerae LIM ; Jin Yong JUN ; Seon Wan KI ; Hong Jin JEON ; Sun Jung KWON ; Hwa-Young LEE
Psychiatry Investigation 2025;22(1):117-117
8.Development of a Standardized Suicide Prevention Program for Gatekeeper Intervention in Korea (Suicide CARE Version 2.0) to Prevent Adolescent Suicide: Version for Teachers
Hyeon-Ah LEE ; Yeon Jung LEE ; Kyong Ah KIM ; Myungjae BAIK ; Jong-Woo PAIK ; Jinmi SEOL ; Sang Min LEE ; Eun-Jin LEE ; Haewoo LEE ; Meerae LIM ; Jin Yong JUN ; Seon Wan KI ; Hong Jin JEON ; Sun Jung KWON ; Hwa-Young LEE
Psychiatry Investigation 2025;22(1):117-117
9.Development of a Standardized Suicide Prevention Program for Gatekeeper Intervention in Korea (Suicide CARE Version 2.0) to Prevent Adolescent Suicide: Version for Teachers
Hyeon-Ah LEE ; Yeon Jung LEE ; Kyong Ah KIM ; Myungjae BAIK ; Jong-Woo PAIK ; Jinmi SEOL ; Sang Min LEE ; Eun-Jin LEE ; Haewoo LEE ; Meerae LIM ; Jin Yong JUN ; Seon Wan KI ; Hong Jin JEON ; Sun Jung KWON ; Hwa-Young LEE
Psychiatry Investigation 2025;22(1):117-117
10.Relationship between Polygenic Risk Score and the Hypnotics in Bipolar I Disorder
Hyeon Woo LEE ; Bun-Hee LEE ; Tatyana SHEKHTMAN ; Young-Min PARK ; John R. KELSOE
Clinical Psychopharmacology and Neuroscience 2024;22(4):585-593
Objective:
Bipolar disorder (BD) is marked by significant change in mood and energy levels with sleep disturbance a common feature, resulting in diminished quality of life and impaired daily functioning. This study assessed the association between BD-polygenic risk scores (PRS) and hypnotics in bipolar I disorder (BD-I) patients.
Methods:
Large-sample data were collected from the genome-wide association study of a multicenter Bipolar Genomic Study, and 1,394 BD-I patients with available medication information were divided into two groups depending on whether they used hypnotics or not. The Diagnostic Interview for Genetic Studies (DIGS) score was used to assess the clinical manifestations and function of the participants and the association between the use of hypnotics and genetic risk was analyzed.
Results:
Of the 1,394 total participants, 556 (40%) patients received hypnotics, mostly benzodiazepines, administered singly or in combination with other sleeping agents such as, Z-drugs, melatonin-related drugs, and trazodone. The DIGS score was significantly higher for negative categories in the group prescribed hypnotics as was the BD-PRS score, according to the four p value thresholds (p = 0.3, 0.2, 0.1, and 0.05). Logistic regression analysis confirmed a statistically significant association between the BD-PRS and hypnotic use.
Conclusion
Our results suggest an association between hypnotic use and genetic susceptibility to BD. Sleep disturbances in participants were based on the prescription status of hypnotics supporting the hypothesis that sleep disturbances may be associated with genetic aspects of BD-I. Further genetic studies on genetic overlaps between BD and specific phenotypes or medication responses are required.

Result Analysis
Print
Save
E-mail