1.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
2.Consensus Statements on Tinnitus Assessment and Treatment Outcome Evaluation: A Delphi Study by the Korean Tinnitus Study Group
Oak-Sung CHOO ; Jung Mee PARK ; Euyhyun PARK ; Jiwon CHANG ; Min Young LEE ; Ho Yun LEE ; In Seok MOON ; Jae-Jun SONG ; Kyu-Yup LEE ; Jae-Jin SONG ; Eui-Cheol NAM ; Shi Nae PARK ; Hyun Joon SHIM ; Yoon Chan RAH ; Jae-Hyun SEO
Journal of Korean Medical Science 2025;40(7):e93-
Background:
Tinnitus is a multifactorial condition with no universally accepted assessment guidelines. The Korean Tinnitus Study Group previously established consensus statements on the definition, classification, and diagnostic tests for tinnitus. As a continuation of this effort, this study aims to establish expert consensus on tinnitus assessment and treatment outcome evaluation, specifically tailored to the Korean clinical context.
Methods:
A modified Delphi method involving 26 otology experts from across Korea was used. A two-round Delphi survey was conducted to evaluate statements related to tinnitus assessment before and after treatment. Statements were rated on a scale of 1 to 9 for the level of agreement. Consensus was defined as ≥ 70% agreement (score of 7–9) and ≤ 15% disagreement (score of 1–3). Statistical measures such as content validity ratio and Kendall’s coefficient of concordance (W) were calculated to assess agreement levels.
Results:
Of the 46 assessment-related statements, 17 (37%) reached consensus, though overall pre-treatment assessments showed weak agreement (Kendall’s W = 0.319). Key areas of agreement included the use of the visual analogue scale, numeric rating scale, and validated questionnaires for pre-treatment evaluation. Five statements, such as the use of computed tomography, magnetic resonance imaging, and angiography for diagnosing pulsatile tinnitus, achieved over 90% agreement. For treatment outcome measurements, 8 of 12 statements (67%) reached a consensus, with moderate agreement (Kendall’s W = 0.513). Validated questionnaires and psychoacoustic tests were recommended for evaluating treatment effects within 12 weeks. While standardized imaging for pulsatile tinnitus and additional clinical tests were strongly recommended, full consensus was not achieved across all imaging modalities.
Conclusion
This study provides actionable recommendations for tinnitus assessment and treatment evaluation, emphasizing the use of standardized tools and individualized approaches based on patient needs. These findings offer a practical framework to enhance consistency and effectiveness in tinnitus management within Korean clinical settings.
3.Consensus Statements on Tinnitus Assessment and Treatment Outcome Evaluation: A Delphi Study by the Korean Tinnitus Study Group
Oak-Sung CHOO ; Jung Mee PARK ; Euyhyun PARK ; Jiwon CHANG ; Min Young LEE ; Ho Yun LEE ; In Seok MOON ; Jae-Jun SONG ; Kyu-Yup LEE ; Jae-Jin SONG ; Eui-Cheol NAM ; Shi Nae PARK ; Hyun Joon SHIM ; Yoon Chan RAH ; Jae-Hyun SEO
Journal of Korean Medical Science 2025;40(7):e93-
Background:
Tinnitus is a multifactorial condition with no universally accepted assessment guidelines. The Korean Tinnitus Study Group previously established consensus statements on the definition, classification, and diagnostic tests for tinnitus. As a continuation of this effort, this study aims to establish expert consensus on tinnitus assessment and treatment outcome evaluation, specifically tailored to the Korean clinical context.
Methods:
A modified Delphi method involving 26 otology experts from across Korea was used. A two-round Delphi survey was conducted to evaluate statements related to tinnitus assessment before and after treatment. Statements were rated on a scale of 1 to 9 for the level of agreement. Consensus was defined as ≥ 70% agreement (score of 7–9) and ≤ 15% disagreement (score of 1–3). Statistical measures such as content validity ratio and Kendall’s coefficient of concordance (W) were calculated to assess agreement levels.
Results:
Of the 46 assessment-related statements, 17 (37%) reached consensus, though overall pre-treatment assessments showed weak agreement (Kendall’s W = 0.319). Key areas of agreement included the use of the visual analogue scale, numeric rating scale, and validated questionnaires for pre-treatment evaluation. Five statements, such as the use of computed tomography, magnetic resonance imaging, and angiography for diagnosing pulsatile tinnitus, achieved over 90% agreement. For treatment outcome measurements, 8 of 12 statements (67%) reached a consensus, with moderate agreement (Kendall’s W = 0.513). Validated questionnaires and psychoacoustic tests were recommended for evaluating treatment effects within 12 weeks. While standardized imaging for pulsatile tinnitus and additional clinical tests were strongly recommended, full consensus was not achieved across all imaging modalities.
Conclusion
This study provides actionable recommendations for tinnitus assessment and treatment evaluation, emphasizing the use of standardized tools and individualized approaches based on patient needs. These findings offer a practical framework to enhance consistency and effectiveness in tinnitus management within Korean clinical settings.
4.Carnitine Metabolite as a Potential Circulating Biomarker for Sarcopenia in Men
Je Hyun SEO ; Jung-Min KOH ; Han Jin CHO ; Hanjun KIM ; Young‑Sun LEE ; Su Jung KIM ; Pil Whan YOON ; Won KIM ; Sung Jin BAE ; Hong-Kyu KIM ; Hyun Ju YOO ; Seung Hun LEE
Endocrinology and Metabolism 2025;40(1):93-102
Background:
Sarcopenia, a multifactorial disorder involving metabolic disturbance, suggests potential for metabolite biomarkers. Carnitine (CN), essential for skeletal muscle energy metabolism, may be a candidate biomarker. We investigated whether CN metabolites are biomarkers for sarcopenia.
Methods:
Associations between the CN metabolites identified from an animal model of sarcopenia and muscle cells and sarcopenia status were evaluated in men from an age-matched discovery (72 cases, 72 controls) and a validation (21 cases, 47 controls) cohort.
Results:
An association between CN metabolites and sarcopenia showed in mouse and cell studies. In the discovery cohort, plasma C5-CN levels were lower in sarcopenic men (P=0.005). C5-CN levels in men tended to be associated with handgrip strength (HGS) (P=0.098) and were significantly associated with skeletal muscle mass (P=0.003). Each standard deviation increase in C5-CN levels reduced the odds of low muscle mass (odd ratio, 0.61; 95% confidence interval [CI], 0.42 to 0.89). The area under the receiver operating characteristic curve (AUROC) of CN score using a regression equation of C5-CN levels, for sarcopenia was 0.635 (95% CI, 0.544 to 0.726). In the discovery cohort, addition of CN score to HGS significantly improved AUROC from 0.646 (95% CI, 0.575 to 0.717; HGS only) to 0.727 (95% CI, 0.643 to 0.810; P=0.006; HGS+CN score). The improvement was confirmed in the validation cohort (AUROC=0.563; 95% CI, 0.470 to 0.656 for HGS; and AUROC=0.712; 95% CI, 0.569 to 0.855 for HGS+CN score; P=0.027).
Conclusion
C5-CN, indicative of low muscle mass, is a potential circulating biomarker for sarcopenia in men. Further studies are required to confirm these results and explore sarcopenia-related metabolomic changes.
5.Carnitine Metabolite as a Potential Circulating Biomarker for Sarcopenia in Men
Je Hyun SEO ; Jung-Min KOH ; Han Jin CHO ; Hanjun KIM ; Young‑Sun LEE ; Su Jung KIM ; Pil Whan YOON ; Won KIM ; Sung Jin BAE ; Hong-Kyu KIM ; Hyun Ju YOO ; Seung Hun LEE
Endocrinology and Metabolism 2025;40(1):93-102
Background:
Sarcopenia, a multifactorial disorder involving metabolic disturbance, suggests potential for metabolite biomarkers. Carnitine (CN), essential for skeletal muscle energy metabolism, may be a candidate biomarker. We investigated whether CN metabolites are biomarkers for sarcopenia.
Methods:
Associations between the CN metabolites identified from an animal model of sarcopenia and muscle cells and sarcopenia status were evaluated in men from an age-matched discovery (72 cases, 72 controls) and a validation (21 cases, 47 controls) cohort.
Results:
An association between CN metabolites and sarcopenia showed in mouse and cell studies. In the discovery cohort, plasma C5-CN levels were lower in sarcopenic men (P=0.005). C5-CN levels in men tended to be associated with handgrip strength (HGS) (P=0.098) and were significantly associated with skeletal muscle mass (P=0.003). Each standard deviation increase in C5-CN levels reduced the odds of low muscle mass (odd ratio, 0.61; 95% confidence interval [CI], 0.42 to 0.89). The area under the receiver operating characteristic curve (AUROC) of CN score using a regression equation of C5-CN levels, for sarcopenia was 0.635 (95% CI, 0.544 to 0.726). In the discovery cohort, addition of CN score to HGS significantly improved AUROC from 0.646 (95% CI, 0.575 to 0.717; HGS only) to 0.727 (95% CI, 0.643 to 0.810; P=0.006; HGS+CN score). The improvement was confirmed in the validation cohort (AUROC=0.563; 95% CI, 0.470 to 0.656 for HGS; and AUROC=0.712; 95% CI, 0.569 to 0.855 for HGS+CN score; P=0.027).
Conclusion
C5-CN, indicative of low muscle mass, is a potential circulating biomarker for sarcopenia in men. Further studies are required to confirm these results and explore sarcopenia-related metabolomic changes.
6.Carnitine Metabolite as a Potential Circulating Biomarker for Sarcopenia in Men
Je Hyun SEO ; Jung-Min KOH ; Han Jin CHO ; Hanjun KIM ; Young‑Sun LEE ; Su Jung KIM ; Pil Whan YOON ; Won KIM ; Sung Jin BAE ; Hong-Kyu KIM ; Hyun Ju YOO ; Seung Hun LEE
Endocrinology and Metabolism 2025;40(1):93-102
Background:
Sarcopenia, a multifactorial disorder involving metabolic disturbance, suggests potential for metabolite biomarkers. Carnitine (CN), essential for skeletal muscle energy metabolism, may be a candidate biomarker. We investigated whether CN metabolites are biomarkers for sarcopenia.
Methods:
Associations between the CN metabolites identified from an animal model of sarcopenia and muscle cells and sarcopenia status were evaluated in men from an age-matched discovery (72 cases, 72 controls) and a validation (21 cases, 47 controls) cohort.
Results:
An association between CN metabolites and sarcopenia showed in mouse and cell studies. In the discovery cohort, plasma C5-CN levels were lower in sarcopenic men (P=0.005). C5-CN levels in men tended to be associated with handgrip strength (HGS) (P=0.098) and were significantly associated with skeletal muscle mass (P=0.003). Each standard deviation increase in C5-CN levels reduced the odds of low muscle mass (odd ratio, 0.61; 95% confidence interval [CI], 0.42 to 0.89). The area under the receiver operating characteristic curve (AUROC) of CN score using a regression equation of C5-CN levels, for sarcopenia was 0.635 (95% CI, 0.544 to 0.726). In the discovery cohort, addition of CN score to HGS significantly improved AUROC from 0.646 (95% CI, 0.575 to 0.717; HGS only) to 0.727 (95% CI, 0.643 to 0.810; P=0.006; HGS+CN score). The improvement was confirmed in the validation cohort (AUROC=0.563; 95% CI, 0.470 to 0.656 for HGS; and AUROC=0.712; 95% CI, 0.569 to 0.855 for HGS+CN score; P=0.027).
Conclusion
C5-CN, indicative of low muscle mass, is a potential circulating biomarker for sarcopenia in men. Further studies are required to confirm these results and explore sarcopenia-related metabolomic changes.
7.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
8.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
9.Consensus Statements on Tinnitus Assessment and Treatment Outcome Evaluation: A Delphi Study by the Korean Tinnitus Study Group
Oak-Sung CHOO ; Jung Mee PARK ; Euyhyun PARK ; Jiwon CHANG ; Min Young LEE ; Ho Yun LEE ; In Seok MOON ; Jae-Jun SONG ; Kyu-Yup LEE ; Jae-Jin SONG ; Eui-Cheol NAM ; Shi Nae PARK ; Hyun Joon SHIM ; Yoon Chan RAH ; Jae-Hyun SEO
Journal of Korean Medical Science 2025;40(7):e93-
Background:
Tinnitus is a multifactorial condition with no universally accepted assessment guidelines. The Korean Tinnitus Study Group previously established consensus statements on the definition, classification, and diagnostic tests for tinnitus. As a continuation of this effort, this study aims to establish expert consensus on tinnitus assessment and treatment outcome evaluation, specifically tailored to the Korean clinical context.
Methods:
A modified Delphi method involving 26 otology experts from across Korea was used. A two-round Delphi survey was conducted to evaluate statements related to tinnitus assessment before and after treatment. Statements were rated on a scale of 1 to 9 for the level of agreement. Consensus was defined as ≥ 70% agreement (score of 7–9) and ≤ 15% disagreement (score of 1–3). Statistical measures such as content validity ratio and Kendall’s coefficient of concordance (W) were calculated to assess agreement levels.
Results:
Of the 46 assessment-related statements, 17 (37%) reached consensus, though overall pre-treatment assessments showed weak agreement (Kendall’s W = 0.319). Key areas of agreement included the use of the visual analogue scale, numeric rating scale, and validated questionnaires for pre-treatment evaluation. Five statements, such as the use of computed tomography, magnetic resonance imaging, and angiography for diagnosing pulsatile tinnitus, achieved over 90% agreement. For treatment outcome measurements, 8 of 12 statements (67%) reached a consensus, with moderate agreement (Kendall’s W = 0.513). Validated questionnaires and psychoacoustic tests were recommended for evaluating treatment effects within 12 weeks. While standardized imaging for pulsatile tinnitus and additional clinical tests were strongly recommended, full consensus was not achieved across all imaging modalities.
Conclusion
This study provides actionable recommendations for tinnitus assessment and treatment evaluation, emphasizing the use of standardized tools and individualized approaches based on patient needs. These findings offer a practical framework to enhance consistency and effectiveness in tinnitus management within Korean clinical settings.
10.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.

Result Analysis
Print
Save
E-mail