1.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Efficacy of Gemigliptin Add-on to Dapagliflozin and Metformin in Type 2 Diabetes Patients: A Randomized, Double-Blind, Placebo-Controlled Study (SOLUTION)
Byung Wan LEE ; KyungWan MIN ; Eun-Gyoung HONG ; Bon Jeong KU ; Jun Goo KANG ; Suk CHON ; Won-Young LEE ; Mi Kyoung PARK ; Jae Hyeon KIM ; Sang Yong KIM ; Keeho SONG ; Soon Jib YOO
Endocrinology and Metabolism 2023;38(3):328-337
Background:
This study evaluated the efficacy and safety of add-on gemigliptin in patients with type 2 diabetes mellitus (T2DM) who had inadequate glycemic control with metformin and dapagliflozin.
Methods:
In this randomized, placebo-controlled, parallel-group, double-blind, phase III study, 315 patients were randomized to receive either gemigliptin 50 mg (n=159) or placebo (n=156) with metformin and dapagliflozin for 24 weeks. After the 24-week treatment, patients who received the placebo were switched to gemigliptin, and all patients were treated with gemigliptin for an additional 28 weeks.
Results:
The baseline characteristics were similar between the two groups, except for body mass index. At week 24, the least squares mean difference (standard error) in hemoglobin A1c (HbA1c) changes was –0.66% (0.07) with a 95% confidence interval of –0.80% to –0.52%, demonstrating superior HbA1c reduction in the gemigliptin group. After week 24, the HbA1c level significantly decreased in the placebo group as gemigliptin was administered, whereas the efficacy of HbA1c reduction was maintained up to week 52 in the gemigliptin group. The safety profiles were similar: the incidence rates of treatment-emergent adverse events up to week 24 were 27.67% and 29.22% in the gemigliptin and placebo groups, respectively. The safety profiles after week 24 were similar to those up to week 24 in both groups, and no new safety findings, including hypoglycemia, were noted.
Conclusion
Add-on gemigliptin was well tolerated, providing comparable safety profiles and superior efficacy in glycemic control over placebo for long-term use in patients with T2DM who had poor glycemic control with metformin and dapagliflozin.
6.National Survey Regarding the Management of Difficult Bile Duct Stones in South Korea
Yoon Suk LEE ; Tae Joo JEON ; Woo Hyun PAIK ; Dong-Won AHN ; Kwang Hyun CHUNG ; Byoung Kwan SON ; Tae Jun SONG ; Sung-Hoon MOON ; Eaum Seok LEE ; Jae Min LEE ; Seung Bae YOON ; Chang Nyol PAIK ; Yun Nah LEE ; Jin-Seok PARK ; Dong Wook LEE ; Sang Wook PARK ; Hyung Ku CHON ; Kwang Bum CHO ; Chang Hwan PARK ;
Gut and Liver 2023;17(3):475-481
Background/Aims:
This study aimed to investigate the patterns of preferred endoscopic procedure types and techniques for managing difficult common bile duct (CBD) stones in South Korea.
Methods:
The Committee of Policy and Quality Management of Korean Pancreatobiliary Association (KPBA) conducted a survey containing 19 questions. Both paper and online surveys were carried out; with the paper survey being conducted during the 2019 Annual Congress of KPBA and the online survey being conducted through Google Forms from April 2020 to February 2021.
Results:
The response rate was approximately 41.3% (86/208). Sixty-two (73.0%) worked at tertiary hospitals or academic medical centers, and 60 (69.7%) had more than 5 years of endoscopic retrograde cholangiopancreatography experience. The preferred size criteria for large CBD stones were 15 mm (40.6%), 20 mm (31.3%), and 30 mm (4.6%). For managing of large CBD stones, endoscopic papillary large balloon dilation after endoscopic sphincterotomy was the most preferred technique (74.4%). When performing procedures in those with bleeding diathesis, 64 (74.4%) respondents favored endoscopic papillary balloon dilation (EPBD) alone or EPBD with small endoscopic sphincterotomy. Fifty-five respondents (63.9%) preferred the doubleguidewire technique when faced with difficult bile duct cannulation in patients with periampullary diverticulum. In surgically altered anatomies, cap-fitted forward viewing endoscopy (76.7%) and percutaneous transhepatic cholangioscopy (48.8%) were the preferred techniques for Billroth-II anastomosis and total gastrectomy with Roux-en-Y anastomosis, respectively.
Conclusions
Most respondents showed unifying trends for the management of difficult CBD stones. The current practice patterns could be used as basic data for clinical quality improvements in the management of difficult CBD stones.
7.Current Practice Patterns of Endoscopic Ultrasound-Guided Tissue Sampling for Pancreatic Solid Mass in Korea: Outcomes of a National Survey
Dong-Won AHN ; Hyung Ku CHON ; Sung-Hoon MOON ; Sang Wook PARK ; Woo Hyun PAIK ; Chang Nyol PAIK ; Byoung Kwan SON ; Tae Jun SONG ; Eaum Seok LEE ; Yun Nah LEE ; Yoon Suk LEE ; Jae Min LEE ; Tae Joo JEON ; Chang Hwan PARK ; Kwang Bum CHO ; Dong Wook LEE ; Hong Ja KIM ; Seung Bae YOON ; Kwang Hyun CHUNG ; Jin-Seok PARK
Gut and Liver 2023;17(2):328-336
Background/Aims:
Although endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) and fine needle biopsy (FNB) are widely used for tissue acquisition of pancreatic solid mass, the optimal strategy of this procedure has not been established yet. The aim of this nationwide study was to investigate the current practice patterns of EUS-FNA/FNB for pancreatic solid mass in Korea.
Methods:
The Policy-Quality Management of the Korean Pancreatobiliary Association (KPBA) developed a questionnaire containing 22 questions. An electronic survey consisting of the questionnaire was distributed by e-mail to members registered to the KPBA.
Results:
A total of 101 respondents completed the survey. Eighty respondents (79.2%) performed preoperative EUS-FNA/FNB for operable pancreatic solid mass. Acquire needles (60.4%) were used the most, followed by ProCore needles (47.5%). In terms of need size, most respondents (>80%) preferred 22-gauge needles regardless of the location of the mass. Negative suction with a 10-mL syringe (71.3%) as sampling technique was followed by stylet slow-pull (41.6%). More than three needle passes for EUS-FNA/FNB was performed by most respondents (>80%). The frequency of requiring repeated procedure was significantly higher in respondents with a low individual volume (<5 per month, p=0.001). Prophylactic antibiotics were routinely used in 39 respondents (38.6%); rapid on-site pathologic evaluation was used in 6.1%.
Conclusions
According to this survey, practices of EUS-FNA/FNB for pancreatic solid mass varied substantially, some of which differed considerably from the recommendations present in existing guidelines. These results suggest that the development of evidence-based quality guidelines fitting Korean clinical practice is needed to establish the optimal strategy for this procedure.
8.The Clinical Outcomes of Marginal Donor Hearts: A Single Center Experience
Soo Yong LEE ; Seok Hyun KIM ; Min Ho JU ; Mi Hee LIM ; Chee-hoon LEE ; Hyung Gon JE ; Ji Hoon LIM ; Ga Yun KIM ; Ji Soo OH ; Jin Hee CHOI ; Min Ku CHON ; Sang Hyun LEE ; Ki Won HWANG ; Jeong Su KIM ; Yong Hyun PARK ; June Hong KIM ; Kook Jin CHUN
Korean Circulation Journal 2023;53(4):254-267
Background and Objectives:
Although the shortage of donor is a common problem worldwide, a significant portion of unutilized hearts are classified as marginal donor (MD) hearts. However, research on the correlation between the MD and the prognosis of heart transplantation (HTx) is lacking. This study was conducted to investigate the clinical impact of MD in HTx.
Methods:
Consecutive 73 HTxs during 2014 and 2021 in a tertiary hospital were analyzed.MD was defined as follows; a donor age >55 years, left ventricular ejection fraction <50%, cold ischemic time >240 minutes, or significant cardiac structural problems. Preoperative characteristics and postoperative hemodynamic data, primary graft dysfunction (PGD), and the survival rate were analyzed. Risk stratification by Index for Mortality Prediction after Cardiac Transplantation (IMPACT) score was performed to examine the outcomes according to the recipient state. Each group was sub-divided into 2 risk groups according to the IMPACT score (low <10 vs. high ≥10).
Results:
A total of 32 (43.8%) patients received an organ from MDs. Extracorporeal membrane oxygenation was more frequent in the non-MD group (34.4% vs. 70.7, p=0.007) There was no significant difference in PGD, 30-day mortality and long-term survival between groups. In the subgroup analysis, early outcomes did not differ between low- and high-risk groups. However, the long-term survival was better in the low-risk group (p=0.01).
Conclusions
The outcomes of MD group were not significantly different from non-MD group. Particularly, in low-risk recipient, the MD group showed excellent early and longterm outcomes. These results suggest the usability of selected MD hearts without increasing adverse events.
9.Current trends in the management of pancreatic cystic neoplasms in Korea: a national survey
Hyung Ku CHON ; Sung Hoon MOON ; Sang Wook PARK ; Woo Hyun PAIK ; Chang Nyol PAIK ; Byoung Kwan SON ; Tae Jun SONG ; Dong Won AHN ; Eaum Seok LEE ; Yun Nah LEE ; Yoon Suk LEE ; Jae Min LEE ; Tae Joo JEON ; Chang-Hwan PARK ; Kwang Bum CHO ; Dong Wook LEE
The Korean Journal of Internal Medicine 2022;37(1):63-72
Background/Aims:
The study aimed to investigate the current practice patterns in the management of pancreatic cystic neoplasms in Korea.
Methods:
An electronic survey was systematically distributed by email to members of the Korean Pancreatobiliary Association from December 2019 to February 2020.
Results:
In total, 115 (110 gastroenterologists, five surgeons) completed the survey, 72.2% of whom worked in a tertiary/academic medical center. Most (65.2%) followed the 2012/2017 International Association of Pancreatology guidelines for the management of pancreatic cystic neoplasms. A gadolinium-enhanced magnetic resonance imaging/magnetic resonance cholangiopancreatography was the most common first-line diagnostic modality (42.1%), but a contrast-enhanced computed tomography scan was preferred as a subsequent surveillance tool (58.3%). Seventy- four percent of respondents routinely performed endoscopic ultrasound-guided fine needle aspiration for pancreatic cystic neoplasms with suspicious mural nodules. Endoscopic ultrasound-guided fine needle aspiration cytology (94.8%) and cystic fluid carcinoembryonic antigen (95.7%) were used for cystic fluid analysis. Most (94%) typically recommended surgery in patients with high-risk stigmata, but 18.3% also considered proceeding with surgery in patients with worrisome features. Most (96.5%) would continue surveillance of pancreatic cystic neoplasms for more than 5 years.
Conclusions
According to this survey, there was variability in the management of pancreatic cystic neoplasms among the respondents. These results suggest that the development of evidence-based guidelines for pancreatic cystic neoplasms that fit the Korean practice is needed to create an optimal approach to the management of pancreatic cystic neoplasms.
10.2021 Korean Society of Gastrointestinal Endoscopy Clinical Practice Guidelines for Endoscopic Sedation
Hong Jun PARK ; Byung-Wook KIM ; Jun Kyu LEE ; Yehyun PARK ; Jin Myung PARK ; Jun Yong BAE ; Seung Young SEO ; Jae Min LEE ; Jee Hyun LEE ; Hyung Ku CHON ; Jun-Won CHUNG ; Hyun Ho CHOI ; Myung Ha KIM ; Dong Ah PARK ; Jae Hung JUNG ; Joo Young CHO ; Endoscopic Sedation Committee of Korean Society of Gastrointestinal Endoscopy
Gut and Liver 2022;16(3):341-356
Sedation can resolve anxiety and fear in patients undergoing endoscopy. The use of sedatives has increased in Korea. Appropriate sedation is a state in which the patient feels subjectively comfortable while maintaining the airway reflex for stable spontaneous breathing. The patient should maintain a state of consciousness to the extent that he or she can cooperate with the needs of the medical staff. Despite its benefits, endoscopic sedation has been associated with cardiopulmonary complications. Such cardiopulmonary complications are usually temporary, and most patients recover without sequelae. However, these events may progress to serious complications, such as cardiovascular collapse. Therefore, it is essential to screen high-risk patients before sedation and reduce complications by meticulous monitoring. Additionally, physicians should be familiar with the management of emergencies. The first Korean clinical practice guideline for endoscopic sedation was developed based on previous worldwide guidelines for endoscopic sedation using an adaptation process. The guideline consists of nine recommendations based on a critical review of currently available data and expert consensus when the guideline was drafted. These guidelines should provide clinicians, nurses, medical school students, and policy makers with information on how to perform endoscopic sedation with minimal risk.

Result Analysis
Print
Save
E-mail