1.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
2.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
3.Prevention and management of diagnostic blood loss in critically ill patients:a summary of best evidence
Wei WU ; Haiyan HUANG ; Yuanyuan MI ; Jinkai LUO ; Yanhong JIN ; Ting YOU
Modern Clinical Nursing 2025;24(9):75-83
Objective To systematically retrieve,evaluate and summarise the best available evidence on prevention and management of diagnostic blood loss in critically ill adult patients and to provide guidance for standardising diagnostic blood sampling in clinical practice.Methods A structured evidence question was created using the PIPOST framework(Population,Intervention,Professional,Outcome,Setting and Type of evidence).Guided by the"5S"levels-of-evidence pyramid,a top-down systematic search was conducted on databases of BMJ Best Practice,UpToDate,the Joanna Briggs Institute(JBI)EBP Database,GIN,SIGN,RNAO,NICE,Medlive Guideline,WHO,National Blood Authority(Australia),National Health Commission of China,Cochrane Library,PubMed,EMbase,CINAHL,Web of Science,Wanfang Data,CNKI,VIP,and SinoMed.Searched literature included clinical decision aids,guidelines,evidence summaries,systematic reviews Meta analysis,RCTs,quasi-experimental,cross-sectional,cohort studies and expert consensus/opinions.Search period covered between 1st January 2015 and 10th February 2025.Quality appraisal,evidence extraction,synthesis and grading were performed according to JBI and GRADE approaches.Results Nineteen articles were retrieved including five guidelines,five systematic reviews,one RCT,two quasi-experimental studies,two cross-sectional studies,one professional standard and three expert consensuses.A total of 26 recommendations were extracted and they were organised into five domains:education and training,blood-sampling assessment,frequency of sampling,strategies to minimise blood volume drawn,and quality control.Conclusion This evidence summary provides the best current guidance for preventing and managing iatrogenic blood loss caused by diagnostic testing in critically ill adults,providing evidence-based basis for standardizing blood tests by medical staff.
4.Prevention and management of diagnostic blood loss in critically ill patients:a summary of best evidence
Wei WU ; Haiyan HUANG ; Yuanyuan MI ; Jinkai LUO ; Yanhong JIN ; Ting YOU
Modern Clinical Nursing 2025;24(9):75-83
Objective To systematically retrieve,evaluate and summarise the best available evidence on prevention and management of diagnostic blood loss in critically ill adult patients and to provide guidance for standardising diagnostic blood sampling in clinical practice.Methods A structured evidence question was created using the PIPOST framework(Population,Intervention,Professional,Outcome,Setting and Type of evidence).Guided by the"5S"levels-of-evidence pyramid,a top-down systematic search was conducted on databases of BMJ Best Practice,UpToDate,the Joanna Briggs Institute(JBI)EBP Database,GIN,SIGN,RNAO,NICE,Medlive Guideline,WHO,National Blood Authority(Australia),National Health Commission of China,Cochrane Library,PubMed,EMbase,CINAHL,Web of Science,Wanfang Data,CNKI,VIP,and SinoMed.Searched literature included clinical decision aids,guidelines,evidence summaries,systematic reviews Meta analysis,RCTs,quasi-experimental,cross-sectional,cohort studies and expert consensus/opinions.Search period covered between 1st January 2015 and 10th February 2025.Quality appraisal,evidence extraction,synthesis and grading were performed according to JBI and GRADE approaches.Results Nineteen articles were retrieved including five guidelines,five systematic reviews,one RCT,two quasi-experimental studies,two cross-sectional studies,one professional standard and three expert consensuses.A total of 26 recommendations were extracted and they were organised into five domains:education and training,blood-sampling assessment,frequency of sampling,strategies to minimise blood volume drawn,and quality control.Conclusion This evidence summary provides the best current guidance for preventing and managing iatrogenic blood loss caused by diagnostic testing in critically ill adults,providing evidence-based basis for standardizing blood tests by medical staff.
5.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
6.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
7.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
8.Primary Cutaneous CD30+ Lymphoproliferative Disorders in South Korea: A Nationwide, Multi-Center, Retrospective, Clinical, and Prognostic Study
Woo Jin LEE ; Sook Jung YUN ; Joon Min JUNG ; Joo Yeon KO ; Kwang Ho KIM ; Dong Hyun KIM ; Myung Hwa KIM ; You Chan KIM ; Jung Eun KIM ; Chan-Ho NA ; Je-Ho MUN ; Jong Bin PARK ; Ji-Hye PARK ; Hai-Jin PARK ; Dong Hoon SHIN ; Jeonghyun SHIN ; Sang Ho OH ; Seok-Kweon YUN ; Dongyoun LEE ; Seok-Jong LEE ; Seung Ho LEE ; Young Bok LEE ; Soyun CHO ; Sooyeon CHOI ; Jae Eun CHOI ; Mi Woo LEE ; On behalf of The Korean Society of Dermatopathology
Annals of Dermatology 2025;37(2):75-85
Background:
Primary cutaneous CD30+ lymphoproliferative disorders (pcCD30-LPDs) are a diseases with various clinical and prognostic characteristics.
Objective:
Increasing our knowledge of the clinical characteristics of pcCD30-LPDs and identifying potential prognostic variables in an Asian population.
Methods:
Clinicopathological features and survival data of pcCD30-LPD cases obtained from 22 hospitals in South Korea were examined.
Results:
A total of 413 cases of pcCD30-LPDs (lymphomatoid papulosis [LYP], n=237; primary cutaneous anaplastic large cell lymphoma [C-ALCL], n=176) were included. Ninety percent of LYP patients and roughly 50% of C-ALCL patients presented with multiple skin lesions. Both LYP and C-ALCL affected the lower limbs most frequently. Multiplicity and advanced T stage of LYP lesions were associated with a chronic course longer than 6 months. Clinical morphology with patch lesions and elevated serum lactate dehydrogenase were significantly associated with LPDs during follow-up in LYP patients. Extracutaneous involvement of C-ALCL occurred in 13.2% of patients. Lesions larger than 5 cm and increased serum lactate dehydrogenase were associated with a poor prognosis in C-ALCL. The survival of patients with C-ALCL was unaffected by the anatomical locations of skin lesions or other pathological factors.
Conclusion
The multiplicity or size of skin lesions was associated with a chronic course of LYP and survival among patients with C-ALCL.
9.Relationship of MicroRNA according to Immune Components of Breast Milk in Korean Lactating Mothers
You Jin CHOI ; Da Hye LEE ; Jeonglyn SONG ; Ki-Uk KIM ; Hyeyoung MIN ; Sung-Hoon CHUNG ; Tae Hyeong KIM ; Chae-Young KIM ; Insoo KANG ; Na Mi LEE ; Dae Yong YI
Pediatric Gastroenterology, Hepatology & Nutrition 2024;27(5):322-331
Purpose:
Human breast milk (HBM) contains immune components that produced and delivered from the mother along with nutrients necessary for the baby. MicroRNA (miRNA) is a small noncoding RNA molecule, that is used as an ideal biomarker for diagnosis and prognosis of various diseases and are more abundant in HBM. We analyzed and compared the immune components and miRNAs of HBM.
Methods:
HBM were collected from 20 healthy breastfeeding mothers. We measured the amount of lactoferrin, lysozyme, and immunoglobulin A (IgA) and extracted the miRNAs from each breast milk samples. Next, the top 5 and bottom 5 expressed miRNAs were compared and analyzed based on the amounts of the 3 immune components.
Results:
The mean levels and ranges of lactoferrin, lysozyme, and IgA were 6.33 (2.24–14.77)×106 ng/mL, 9.90 (1.42–17.59)×107 pg/mL, and 6.64 (0.48–20.01)×105 ng/mL, respectively. The miRNAs concentration per 1 mL of skim milk was 40.54 (14.95–110.01) ng/μL. Comparing the bottom 5 and top 5 groups of each immune component, 19 miRNAs were significantly upregulated (6, 9, and 4 targeting lactoferrin, lysozyme, and IgA, respectively) and 21 were significantly downregulated (4, 9, and 8 targeting lactoferrin, lysozyme, and IgA, respectively). There were no miRNAs that were expressed significantly higher or lower in common to all 3 components.However, 2 and 3 miRNAs were commonly overexpressed and underexpressed, in the top 5 groups of lysozyme and IgA concentrations.
Conclusion
We identified the immune components and miRNAs in breast milk and found that each individual has different ingredients.
10.Efficacy and safety of denosumab treatment for Korean patients with Stage 3b–4 chronic kidney disease and osteoporosis
Jin Taek KIM ; You Mi KIM ; Kyong Yeun JUNG ; Hoonsung CHOI ; So Young LEE ; Hyo-Jeong KIM
The Korean Journal of Internal Medicine 2024;39(1):148-159
Background/Aims:
We evaluated the efficacy and safety of denosumab treatment in severe chronic kidney disease (CKD) patients with osteoporosis. We also investigated whether the treatment affects the coronary artery calcifications.
Methods:
Twenty-seven postmenopausal women with Stage 3b–4 CKD and osteoporosis were enrolled. Twenty patients received denosumab plus calcium carbonate and vitamin D, and seven controls received calcium carbonate and vitamin D for 1 year. Dual-energy X-ray absorptiometry and coronary artery calcium (CAC) scoring computed tomography were performed before and after treatment. Hypocalcemic symptoms and serum calcium levels were evaluated.
Results:
After 1 year of treatment, the percent changes of femur neck (3.6 ± 3.2% vs. -0.7 ± 4.4%, p = 0.033) and total hip (3.4 ± 3.8% vs. -1.9 ± 2.1%, p = 0.001) bone mineral density (BMD) were significantly increased in the denosumab treated group compared to the control group. However, the percent change of lumbar spine BMD did not differ between two groups (5.6 ± 5.9% vs. 2.7 ± 3.9%, p = 0.273). The percent change of bone alkaline phosphatase was significantly different in the denosumab-treated group and control group (-31.1 ± 30.0% vs. 0.5 ± 32.0%, p = 0.027). CAC scores did not differ between groups. No hypocalcemic events occurred in both groups.
Conclusions
If carefully monitored and supplemented with calcium and vitamin D, denosumab treatment for 1 year provides significant benefits in patients with Stage 3b–4 CKD and osteoporosis. However, denosumab treatment did not affect coronary artery calcifications in these patients.

Result Analysis
Print
Save
E-mail