1.The Effects of Nicotine on Re-endothelialization, Inflammation, and Neoatherosclerosis After Drug-Eluting Stent Implantation in a Porcine Model
Seok OH ; Ju Han KIM ; Saleem AHMAD ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Sung PARK ; Dae Young HYUN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Seung-won LEE ; Youngkeun AHN ; Myung Ho JEONG
Korean Circulation Journal 2025;55(1):50-64
Background and Objectives:
Cigarette smoking is a major risk factor for atherosclerosis.Nicotine, a crucial constituent of tobacco, contributes to atherosclerosis development and progression. However, evidence of the association between nicotine and neointima formation is limited. We aimed to evaluate whether nicotine enhances neointimal hyperplasia in the native epicardial coronary arteries of pigs after percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Methods:
After coronary angiography (CAG) and quantitative coronary angiography (QCA), we implanted 20 DES into 20 pigs allocated to 2 groups: no-nicotine (n=10) and nicotine (n=10) groups. Post-PCI CAG and QCA were performed immediately. Follow-up CAG, QCA, optical coherence tomography (OCT), and histopathological analyses were performed 2 months post-PCI.
Results:
Despite intergroup similarities in the baseline QCA findings, OCT analysis showed that the nicotine group had a smaller mean stent and lumen areas, a larger mean neointimal area, greater percent area stenosis, and higher peri-strut fibrin and inflammation scores than the no-nicotine group. In immunofluorescence analysis, the nicotine group displayed higher expression of CD68 and α-smooth muscle actin but lower CD31 expression than the no-nicotine group.
Conclusions
Nicotine inhibited re-endothelialization and promoted inflammation and NIH after PCI with DES in a porcine model.
2.The Effects of Nicotine on Re-endothelialization, Inflammation, and Neoatherosclerosis After Drug-Eluting Stent Implantation in a Porcine Model
Seok OH ; Ju Han KIM ; Saleem AHMAD ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Sung PARK ; Dae Young HYUN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Seung-won LEE ; Youngkeun AHN ; Myung Ho JEONG
Korean Circulation Journal 2025;55(1):50-64
Background and Objectives:
Cigarette smoking is a major risk factor for atherosclerosis.Nicotine, a crucial constituent of tobacco, contributes to atherosclerosis development and progression. However, evidence of the association between nicotine and neointima formation is limited. We aimed to evaluate whether nicotine enhances neointimal hyperplasia in the native epicardial coronary arteries of pigs after percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Methods:
After coronary angiography (CAG) and quantitative coronary angiography (QCA), we implanted 20 DES into 20 pigs allocated to 2 groups: no-nicotine (n=10) and nicotine (n=10) groups. Post-PCI CAG and QCA were performed immediately. Follow-up CAG, QCA, optical coherence tomography (OCT), and histopathological analyses were performed 2 months post-PCI.
Results:
Despite intergroup similarities in the baseline QCA findings, OCT analysis showed that the nicotine group had a smaller mean stent and lumen areas, a larger mean neointimal area, greater percent area stenosis, and higher peri-strut fibrin and inflammation scores than the no-nicotine group. In immunofluorescence analysis, the nicotine group displayed higher expression of CD68 and α-smooth muscle actin but lower CD31 expression than the no-nicotine group.
Conclusions
Nicotine inhibited re-endothelialization and promoted inflammation and NIH after PCI with DES in a porcine model.
3.The Effects of Nicotine on Re-endothelialization, Inflammation, and Neoatherosclerosis After Drug-Eluting Stent Implantation in a Porcine Model
Seok OH ; Ju Han KIM ; Saleem AHMAD ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Sung PARK ; Dae Young HYUN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Seung-won LEE ; Youngkeun AHN ; Myung Ho JEONG
Korean Circulation Journal 2025;55(1):50-64
Background and Objectives:
Cigarette smoking is a major risk factor for atherosclerosis.Nicotine, a crucial constituent of tobacco, contributes to atherosclerosis development and progression. However, evidence of the association between nicotine and neointima formation is limited. We aimed to evaluate whether nicotine enhances neointimal hyperplasia in the native epicardial coronary arteries of pigs after percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Methods:
After coronary angiography (CAG) and quantitative coronary angiography (QCA), we implanted 20 DES into 20 pigs allocated to 2 groups: no-nicotine (n=10) and nicotine (n=10) groups. Post-PCI CAG and QCA were performed immediately. Follow-up CAG, QCA, optical coherence tomography (OCT), and histopathological analyses were performed 2 months post-PCI.
Results:
Despite intergroup similarities in the baseline QCA findings, OCT analysis showed that the nicotine group had a smaller mean stent and lumen areas, a larger mean neointimal area, greater percent area stenosis, and higher peri-strut fibrin and inflammation scores than the no-nicotine group. In immunofluorescence analysis, the nicotine group displayed higher expression of CD68 and α-smooth muscle actin but lower CD31 expression than the no-nicotine group.
Conclusions
Nicotine inhibited re-endothelialization and promoted inflammation and NIH after PCI with DES in a porcine model.
4.The Effects of Nicotine on Re-endothelialization, Inflammation, and Neoatherosclerosis After Drug-Eluting Stent Implantation in a Porcine Model
Seok OH ; Ju Han KIM ; Saleem AHMAD ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Sung PARK ; Dae Young HYUN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Seung-won LEE ; Youngkeun AHN ; Myung Ho JEONG
Korean Circulation Journal 2025;55(1):50-64
Background and Objectives:
Cigarette smoking is a major risk factor for atherosclerosis.Nicotine, a crucial constituent of tobacco, contributes to atherosclerosis development and progression. However, evidence of the association between nicotine and neointima formation is limited. We aimed to evaluate whether nicotine enhances neointimal hyperplasia in the native epicardial coronary arteries of pigs after percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Methods:
After coronary angiography (CAG) and quantitative coronary angiography (QCA), we implanted 20 DES into 20 pigs allocated to 2 groups: no-nicotine (n=10) and nicotine (n=10) groups. Post-PCI CAG and QCA were performed immediately. Follow-up CAG, QCA, optical coherence tomography (OCT), and histopathological analyses were performed 2 months post-PCI.
Results:
Despite intergroup similarities in the baseline QCA findings, OCT analysis showed that the nicotine group had a smaller mean stent and lumen areas, a larger mean neointimal area, greater percent area stenosis, and higher peri-strut fibrin and inflammation scores than the no-nicotine group. In immunofluorescence analysis, the nicotine group displayed higher expression of CD68 and α-smooth muscle actin but lower CD31 expression than the no-nicotine group.
Conclusions
Nicotine inhibited re-endothelialization and promoted inflammation and NIH after PCI with DES in a porcine model.
5.Preliminary Investigation on Efficacy and Safety of Substance P-Coated Stent for Promoting Re-Endothelialization: A Porcine Coronary Artery Restenosis Model
Dae Sung PARK ; Seok OH ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Young HYUN ; Kyung Hoon CHO ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Manuel HERMIDA-PRIETO ; José Manuel VÁZQUEZ-RODRIGUEZ ; Juan Luis GUTIÉRREZ- CHICO ; Luis MARINÃS-PARDO ; Kyung Seob LIM ; Jun-Kyu PARK ; Dae-Heung BYEON ; Young-Nan CHO ; Seung-Jung KEE ; Doo Sun SIM ; Myung Ho JEONG
Tissue Engineering and Regenerative Medicine 2024;21(1):53-64
BACKGROUND:
Current polymer-based drug-eluting stents (DESs) have fundamental issues about inflammation and delayed re-endothelializaton of the vessel wall. Substance-P (SP), which plays an important role in inflammation and endothelial cells, has not yet been applied to coronary stents. Therefore, this study compares poly lactic-co-glycolic acid (PLGA)-based everolimus-eluting stents (PLGA-EESs) versus 2-methacryloyloxyethyl phosphorylcholine (MPC)-based SP-eluting stents (MPC-SPs) in in-vitro and in-vivo models.
METHODS:
The morphology of the stent surface and peptide/drug release kinetics from stents were evaluated. The invitro proliferative effect of SP released from MPC-SP is evaluated using human umbilical vein endothelial cell. Finally, the safety and efficacy of the stent are evaluated after inserting it into a pig’s coronary artery.
RESULTS:
Similar to PLGA-EES, MPC-SP had a uniform surface morphology with very thin coating layer thickness (2.074 lm). MPC-SP showed sustained drug release of SP for over 2 weeks. Endothelial cell proliferation was significantly increased in groups treated with SP (n = 3) compared with the control (n = 3) and those with everolimus (n = 3) (SP:118.9 ± 7.61% vs. everolimus: 64.3 ± 12.37% vs. the control: 100 ± 6.64%, p < 0.05). In the animal study, the percent stenosis was higher in MPC-SP group (n = 7) compared to PLGA-EES group (n = 7) (MPC-SP: 28.6 ± 10.7% vs. PLGAEES: 16.7 ± 6.3%, p < 0.05). MPC-SP group showed, however, lower inflammation (MPC-SP: 0.3 ± 0.26 vs. PLGAEES: 1.2 ± 0.48, p < 0.05) and fibrin deposition (MPC-SP: 1.0 ± 0.73 vs. PLGA-EES: 1.5 ± 0.59, p < 0.05) around the stent strut. MPC-SP showed more increased expression of cluster of differentiation 31, suggesting enhanced reendothelialization.
CONCLUSION
Compared to PLGA-EES, MPC-SP demonstrated more decreased inflammation of the vascular wall and enhanced re-endothelialization and stent coverage. Hence, MPC-SP has the potential therapeutic benefits for the treatment of coronary artery disease by solving limitations of currently available DESs.
6.Efficacy and Safety Evaluation of Tacrolimus-Eluting Stent in a Porcine Coronary Artery Model
Dae Sung PARK ; Mi Hyang NA ; Myung Ho JEONG ; Doo Sun SIM ; Yu Jeong JIN ; Hae Jin KEE ; Mun Ki KIM ; Jeong Ha KIM ; Young Joon HONG ; Kyung Hoon CHO ; Dae Young HYUN ; Seok OH ; Kyung Seob LIM ; Dae-Heung BYEON ; Jeong Hun KIM
Tissue Engineering and Regenerative Medicine 2024;21(5):723-735
BACKGROUND:
A drug-eluting stent (DES) is a highly beneficial medical device used to widen or unblock narrowed blood vessels. However, the drugs released by the implantation of DES may hinder the re-endothelialization process, increasing the risk of late thrombosis. We have developed a tacrolimus-eluting stent (TES) that as acts as a potent antiproliferative and immunosuppressive agent, enhancing endothelial regeneration. In addition, we assessed the safety and efficacy of TES through both in vitro and in vivo tests.
METHODS:
Tacrolimus and Poly(lactic-co-glycolic acid) (PLGA) were applied to the metal stent using electrospinning equipment. The surface morphology of the stent was examined before and after coating using a scanning electron microscope (SEM) and energy dispersive X-rays (EDX). The drug release test was conducted through high-performance liquid chromatography (HPLC). Cell proliferation and migration assays were performed using smooth muscle cells (SMC).The stent was then inserted into the porcine coronary artery and monitored for a duration of 4 weeks.
RESULTS:
SEM analysis confirmed that the coating surface was uniform. Furthermore, EDX analysis showed that the surface was coated with both polymer and drug components. The HPCL analysis of TCL at a wavelength of 215 nm revealed that the drug was continuously released over a period of 4 weeks. Smooth muscle cell migration was significantly decreased in the tacrolimus group (54.1% ± 11.90%) compared to the non-treated group (90.1% ± 4.86%). In animal experiments, the stenosis rate was significantly reduced in the TES group (29.6% ± 7.93%) compared to the bare metal stent group (41.3% ± 10.18%). Additionally, the fibrin score was found to be lower in the TES group compared to the group treated with a sirolimus-eluting stent (SES).
CONCLUSION
Similar to SES, TES reduces neointimal proliferation in a porcine coronary artery model, specifically decreasing the fibrins score. Therefore, tacrolimus could be considered a promising drug for reducing restenosis and thrombosis.
7.Establishment of Patient-Derived Organoids Using Ascitic or Pleural Fluid from Cancer Patients
Wonyoung CHOI ; Yun-Hee KIM ; Sang Myung WOO ; Yebeen YU ; Mi Rim LEE ; Woo Jin LEE ; Jung Won CHUN ; Sung Hoon SIM ; Heejung CHAE ; Hyoeun SHIM ; Keun Seok LEE ; Sun-Young KONG
Cancer Research and Treatment 2023;55(4):1077-1086
Purpose:
Patient-derived tumor cells can be a powerful resource for studying pathophysiological mechanisms and developing robust strategies for precision medicine. However, establishing organoids from patient-derived cells is challenging because of limited access to tissue specimens. Therefore, we aimed to establish organoids from malignant ascites and pleural effusions.
Materials and Methods:
Ascitic or pleural fluid from pancreatic, gastric, and breast cancer patients was collected and concentrated to culture tumor cells ex vivo. Organoids were considered to be successfully cultured when maintained for five or more passages. Immunohistochemical staining was performed to compare the molecular features, and drug sensitivity was assayed to analyze the clinical responses of original patients.
Results:
We collected 70 fluid samples from 58 patients (pancreatic cancer, n=39; gastric cancer, n=21; and breast cancer, n=10). The overall success rate was 40%; however, it differed with types of malignancy, with pancreatic, gastric, and breast cancers showing 48.7%, 33.3%, and 20%, respectively. Cytopathological results significantly differed between successful and failed cases (p=0.014). Immunohistochemical staining of breast cancer organoids showed molecular features identical to those of tumor tissues. In drug sensitivity assays, pancreatic cancer organoids recapitulated the clinical responses of the original patients.
Conclusion
Tumor organoids established from malignant ascites or pleural effusion of pancreatic, gastric, and breast cancers reflect the molecular characteristics and drug sensitivity profiles. Our organoid platform could be used as a testbed for patients with pleural and peritoneal metastases to guide precision oncology and drug discovery.
8.Development of a prototype simulator for dental education
Mi-El KIM ; Jaehoon SIM ; Aein MON ; Myung-Joo KIM ; Young-Seok PARK ; Ho-Beom KWON ; Jaeheung PARK
The Journal of Korean Academy of Prosthodontics 2023;61(4):257-267
Purpose:
. The purpose of the study was to fabricate a prototype robotic simulator for dental education, to test whether it could simulate mandibular movements, and to assess the possibility of the stimulator responding to stimuli during dental practice.
Materials and methods:
. A virtual simulator model was developed based on segmentation of the hard tissues using cone-beam computed tomography (CBCT) data. The simulator frame was 3D printed using polylactic acid (PLA) material, and dentiforms and silicone face skin were also inserted. Servo actuators were used to control the movements of the simulator, and the simulator’s response to dental stimuli was created by pressure and water level sensors.A water level test was performed to determine the specific threshold of the water level sensor. The mandibular movements and mandibular range of motion of the simulator were tested through computer simulation and the actual model.
Results:
. The prototype robotic simulator consisted of an operational unit, an upper body with an electric device, a head with a temporomandibular joint (TMJ) and dentiforms. The TMJ of the simulator was capable of driving two degrees of freedom, implementing rotational and translational movements. In the water level test, the specific threshold of the water level sensor was 10.35 ml. The mandibular range of motion of the simulator was 50 mm in both computer simulation and the actual model.
Conclusion
. Although further advancements are still required to improve its efficiency and stability, the upper-body prototype simulator has the potential to be useful in dental practice education.
9.Preclinical Evaluation of an Everolimus-Eluting Bioresorbable Vascular Scaffold Via a Long-Term Rabbit Iliac Artery Model
Dae Sung PARK ; Myung Ho JEONG ; Yu Jeong JIN ; Mi Hyang NA ; Doo Sun SIM ; Munki KIM ; Kyung Hoon CHO ; Dae Young HYUN ; Seok OH ; Jeong Ha KIM ; Kyung Seob LIM ; Jun-Kyu PARK ; Han Ki KIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Jeong Hun KIM
Tissue Engineering and Regenerative Medicine 2023;20(2):239-249
BACKGROUND:
Biodegradable poly (l-lactic acid) (PLLA), a bio safe polymer with a large elastic modulus, is widely used in biodegradable medical devices. However, because of its poor mechanical properties, a PLLA strut must be made twice as thick as a metal strut for adequate blood vessel support. Therefore, the mechanical properties of a drug-eluting metal-based stents (MBS) and a bioresorbable vascular scaffolds (BVS) were evaluated and their safety and efficacy were examined via a long-term rabbit iliac artery model.
METHODS:
The surface morphologies of the MBSs and BVSs were investigated via optical and scanning electron microscopy. An everolimus-eluting (EE) BVS or an EE-MBS was implanted into rabbit iliac arteries at a 1.1:1 stent-toartery ratio. Twelve months afterward, stented iliac arteries from each group were analyzed via X-ray angiography, optical coherence tomography (OCT), and histopathologic evaluation.
RESULTS:
Surface morphology analysis of the EE coating on the MBS confirmed that it was uniform and very thin (4.7 lm). Comparison of the mechanical properties of the EE-MBS and EE-BVS showed that the latter outperformed the former in all aspects (radial force (2.75 vs. 0.162 N/mm), foreshortening (0.24% vs. 1.9%), flexibility (0.52 vs. 0.19 N), and recoil (3.2% vs. 6.3%). At all time points, the percent area restenosis was increased in the EE-BVS group compared to the EE-MBS group. The OCT and histopathological analyses indicate no significant changes in strut thickness.
CONCLUSION
BVSs with thinner struts and shorter resorption times should be developed. A comparable long-term safety/efficacy evaluation after complete absorption of BVSs should be conducted.
10.Croup as a Manifestation of SARSCoV-2 Omicron Variant Infection in Young Children
Youn Young CHOI ; You Sun KIM ; Seong Yong LEE ; Jiwoo SIM ; Young June CHOE ; Mi Seon HAN
Journal of Korean Medical Science 2022;37(20):e140-
Croup is an acute upper respiratory disease primarily caused by the parainfluenza virus.Owing to inflammation and edema of the upper airways, children present with barky cough and stridor, and some may experience respiratory distress. We investigated children aged < 5 years with coronavirus disease 2019 (COVID-19) admitted to two hospitals in Seoul, South Korea, and observed a spike in croup cases during the omicron surge. Among the 569 children admitted from March 1, 2021 to February 25, 2022, 21 children (3.7%) had croup, and the proportion of croup cases was significantly higher during the omicron wave than that during the delta wave (12.4% vs. 1.2%, P < 0.001). With the immediate administration of corticosteroids and epinephrine via nebulizer, the symptoms improved rapidly. During the current omicron surge, careful monitoring of the symptoms of croup in young children is needed for the diagnosis of COVID-19 and its timely management.

Result Analysis
Print
Save
E-mail