1.Efficacy of Automatic Suction-Type Sonic Toothbrush and Manual Toothbrush in Preschool Children: A Randomized, Controlled Crossover Pilot Study
Su Bin LEE ; Yong Kwon CHAE ; Mi Sun KIM ; Ok Hyung NAM ; Hyo-Seol LEE ; Sung Chul CHOI ; Ko Eun LEE
Journal of Korean Academy of Pediatric Dentistry 2025;52(2):181-192
This study investigated the plaque removal efficacy of a suction-type sonic toothbrush compared to a conventional manual toothbrush in preschool children aged 30 to 59 months. Using a randomized, double-blind, crossover design with a 2-week washout period, 20 pediatric participants were allocated to two study phases, each using either the suction-type sonic toothbrush or the manual toothbrush with caregiver assistance. The plaque removal effectiveness was assessed through the Silness and Löe plaque index and quantitative light-induced fluorescence values, including ΔR30 and ΔR120 indicators of plaque index. The result showed no statistically significant differences in plaque removal efficacy between the two toothbrushes, although both showed similar improvements. Caregiver feedback revealed high acceptability of the suction-type sonic toothbrush due to its convenience and engaging features, such as a light and suction function, which enhanced the tooth brushing experience. Although limited by the short follow-up period and small sample size, the findings suggest that suction-type sonic toothbrushes may offer practical benefits for young children requiring caregiver assistance.
5.Efficacy of Automatic Suction-Type Sonic Toothbrush and Manual Toothbrush in Preschool Children: A Randomized, Controlled Crossover Pilot Study
Su Bin LEE ; Yong Kwon CHAE ; Mi Sun KIM ; Ok Hyung NAM ; Hyo-Seol LEE ; Sung Chul CHOI ; Ko Eun LEE
Journal of Korean Academy of Pediatric Dentistry 2025;52(2):181-192
This study investigated the plaque removal efficacy of a suction-type sonic toothbrush compared to a conventional manual toothbrush in preschool children aged 30 to 59 months. Using a randomized, double-blind, crossover design with a 2-week washout period, 20 pediatric participants were allocated to two study phases, each using either the suction-type sonic toothbrush or the manual toothbrush with caregiver assistance. The plaque removal effectiveness was assessed through the Silness and Löe plaque index and quantitative light-induced fluorescence values, including ΔR30 and ΔR120 indicators of plaque index. The result showed no statistically significant differences in plaque removal efficacy between the two toothbrushes, although both showed similar improvements. Caregiver feedback revealed high acceptability of the suction-type sonic toothbrush due to its convenience and engaging features, such as a light and suction function, which enhanced the tooth brushing experience. Although limited by the short follow-up period and small sample size, the findings suggest that suction-type sonic toothbrushes may offer practical benefits for young children requiring caregiver assistance.
8.Efficacy of Automatic Suction-Type Sonic Toothbrush and Manual Toothbrush in Preschool Children: A Randomized, Controlled Crossover Pilot Study
Su Bin LEE ; Yong Kwon CHAE ; Mi Sun KIM ; Ok Hyung NAM ; Hyo-Seol LEE ; Sung Chul CHOI ; Ko Eun LEE
Journal of Korean Academy of Pediatric Dentistry 2025;52(2):181-192
This study investigated the plaque removal efficacy of a suction-type sonic toothbrush compared to a conventional manual toothbrush in preschool children aged 30 to 59 months. Using a randomized, double-blind, crossover design with a 2-week washout period, 20 pediatric participants were allocated to two study phases, each using either the suction-type sonic toothbrush or the manual toothbrush with caregiver assistance. The plaque removal effectiveness was assessed through the Silness and Löe plaque index and quantitative light-induced fluorescence values, including ΔR30 and ΔR120 indicators of plaque index. The result showed no statistically significant differences in plaque removal efficacy between the two toothbrushes, although both showed similar improvements. Caregiver feedback revealed high acceptability of the suction-type sonic toothbrush due to its convenience and engaging features, such as a light and suction function, which enhanced the tooth brushing experience. Although limited by the short follow-up period and small sample size, the findings suggest that suction-type sonic toothbrushes may offer practical benefits for young children requiring caregiver assistance.
9.Evaluating Measurements: A Comparative Study of Digital and Plaster Models for Orthodontic Applications in Mixed Dentition
Seo Young SHIN ; Yong Kwon CHAE ; Ko Eun LEE ; Mi Sun KIM ; Ok Hyung NAM ; Hyo-seol LEE ; Sung Chul CHOI
Journal of Korean Academy of Pediatric Dentistry 2024;51(1):55-65
This study aimed to assess the accuracy of tooth widths, intermolar widths, and arch lengths acquired through two intraoral scanners, including iTero Element Plus Series (Align Technology, Santa Clara, CA, USA) and Trios 4 (3Shape, Copenhagen, Denmark), specifically on mixed dentition. A total of 30 subjects were divided into 2 groups, each undergoing both alginate impressions and intraoral scanning using either the iTero or Trios scanner. The plaster models were measured with a caliper, while the digital models were measured virtually. In the iTero group, all tooth width measurements exhibited differences compared to the plaster values, except for maxillary left lateral incisors (p = 0.179), mandibular right (p = 0.285), and left (p = 0.073) central incisors. The Trios group did not display significant differences in any of the tooth width measurements. Intermolar width comparisons for both groups indicated differences, except for mandibular primary canine to primary canine values (p = 0.426) in the iTero group. Regarding arch length, the mandibular anterior, maxillary right, and left arch lengths in the iTero group demonstrated larger caliper values than those of iTero. Conversely, in the Trios group, all parameters showed smaller caliper values, especially in upper anterior, maxillary right, mandibular right, and mandibular left arch lengths with significance (p = 0.027, 0.007, 0.003, and 0.047, respectively). Despite the differences between the two groups, digital models might be clinically suitable alternatives for plaster models. Pediatric dentists should carefully assess these differences, as a comprehensive evaluation would result in precise orthodontic treatment planning and favorable outcomes for young patients with mixed dentition.

Result Analysis
Print
Save
E-mail