1.Empirical study of input, output, outcome and impact of community-based rehabilitation stations
Xiayao CHEN ; Ying DONG ; Xue DONG ; Zhongxiang MI ; Jun CHENG ; Aimin ZHANG ; Didi LU ; Jun WANG ; Jude LIU ; Qianmo AN ; Hui GUO ; Xiaochen LIU ; Zefeng YU
Chinese Journal of Rehabilitation Theory and Practice 2026;32(1):83-89
ObjectiveTo investigate the present situation of input, output, outcome and impact of all registered community-based rehabilitation stations in Inner Mongolia in China, and analyze how the input predict the output, outcome and impact. MethodsFrom March 1st to April 30th, 2025, a questionnaire survey was conducted on all registered community-based rehabilitation stations in Inner Mongolia, covering four dimensions: input, output, outcome and impact. A total of 1 365 questionnaires were distributed. The input included four items: laws and policies, human resources, equipment and facilities, and rehabilitation information management. The output included two items: technical paths and benefits/effectiveness. The outcome included three items: coverage rates, rehabilitation interventions and functional results. The impact included two items: health and sustainability. Each item contained several questions, all of which were described in a positive way. Each question was scored from one to five. A lower score indicated that the situation of the community-based rehabilitation station was more in line with the content described in the question. Regression analysis was performed using the total score of each item of input dimension as independent variables, and the total scores of the output, outcome and impact dimensions as dependent variables. ResultsA total of 1 262 valid questionnaires were collected. The mean values of input, output, outcome and impact of community-based rehabilitation stations were 1.827 to 1.904, with coefficient of variation of 45.892% to 49.239%. The regression analysis showed that, rehabilitation information management, human resources, and laws and policies significantly predicted the output dimension (R² = 0.910, P < 0.001). Meanwhile, all four items in the input dimension predicted both the outcome (R² = 0.850, P < 0.001) and impact dimensions (R² = 0.833, P < 0.001). ConclusionInput, output, outcome and impact of the community-based rehabilitation stations in Inner Mongolia were generally in line with the content of the questions, although some imbalances were observed. Additionally, the input of community-based rehabilitation stations could significantly predict their output, outcome and impact.
2.Two cases of acute radiation-induced skin injury caused by external exposure to 192Ir
Li LI ; Wei SHANG ; Yan LING ; Mi WANG ; Huisheng ZHANG ; Chiqiao LU ; Xiaohu ZHONG ; Shenglong XU ; Juan GUO ; Chang LIU ; Yulong LIU
Chinese Journal of Radiological Health 2026;35(1):56-61
Objective To introduce the causes of accidents and the diagnosis and treatment of two patients with radiation-induced skin injury admitted to our hospital in 2023, and to provide a reference for the clinical treatment of subsequent radiation-induced skin injury. Methods The clinical treatment process of two patients with acute skin injury caused by external radiation exposure were summarized and analyzed. Results The exposure history of the two patients was reconstructed, the flaw detection scenario was simulated, the biological dose and hand skin exposure dose were estimated, and the infrared thermal imaging device was used for dynamic monitoring. A comprehensive analysis was conducted based on clinical manifestations and other data. The diagnosis of “Xie” was excessive exposure combined with acute radiation-induced skin injury on both hands (Grade IV for the right hand palm, index finger, and middle finger and Grade II for the left hand little finger). The diagnosis of “Hao” was acute radiation-induced skin injury on both hands (Grade I). The two patients received different clinical treatment measures: “Xie” was treated with both local and systemic therapies, while “Hao” was mainly treated with systemic therapy. Conclusion After systematic and effective treatment, the radiation-induced skin injuries healed in both patients.
3.Study on the accuracy of resting full-cycle ratio,quantitative flow ratio,and contrast-induced fractional flow reserve in evaluating coronary artery borderline lesions
Rui-tao ZHANG ; Zhen-yu TIAN ; Li-yun HE ; Lin MI ; Li-jun GUO ; Xin-ye XU
Chinese Journal of Interventional Cardiology 2025;33(3):163-169
Objective To compare the accuracy and clinical application value of contrast-induced fractional flow reserve(cFFR),resting full-cycle ratio(RFR),and quantitative flow ratio(QFR)in evaluating coronary artery borderline lesions,using fractional flow reserve(FFR)as the gold standard.Methods A retrospective study was conducted including 143 patients with 143 lesions who underwent coronary angiography(CAG)and were tested for cFFR,RFR,QFR,and FFR at Peking University Third Hospital from September 2020 to January 2022.Clinical data,CAG lesion anatomical data,and target vessel cFFR,RFR,QFR,and FFR measurements were collected.The correlation and diagnostic concordance of cFFR,RFR,QFR,and FFR were analyzed.Results The mean age of the 143 patients was 66(58,71)years,with 90(62.9%)being male.Among them,60(42.0%)patients were diagnosed with unstable angina,and 115(80.4%)target lesions were located in the left anterior descending artery.Correlation analysis showed that RFR,QFR,and cFFR were all significantly correlated with FFR(r=0.956,r=0.861,r=0.751,P<0.001).Bland-Altman analysis demonstrated high agreement between cFFR,RFR,QFR,and FFR.Receiver operating characteristics(ROC)curve analysis showed that the area under the curve(AUC)for RFR corresponding to FFR ≤0.80 was 0.92(95%CI 0.87-0.96),for QFR was 0.89(95%CI 0.83-0.95),and for cFFR was 0.96(95%CI 0.94-0.99).Conclusions cFFR,RFR,and QFR show high concordance with FFR,with similar diagnostic consistency between the three methods and FFR.
4.Model establishment for quantitative analysis of saponins of Paris polyphylla by near-infrared spectroscopy
Ping XU ; Qi MI ; Wen-xiu LUO ; You LU ; Meng-wen YU ; Xuan ZHANG ; Guo-wei ZHENG ; Chang-gui QIU ; Jia CHEN
Chinese Traditional Patent Medicine 2025;47(4):1069-1076
AIM To establish a rapid quantitative analysis model for saponins in Paris polyphylla var.yunnanensis(PPY)by near infrared spectroscopy.METHODS The contents of polyphyllins Ⅰ,Ⅱ,Ⅶ and there total content in PPY were determined by HPLC,while spectral data within the range of 10 000 to 4 000 cm-1 were collected.A quantitative analysis model was established by combining these data with partial least squares regression(PLSR).Multivariate scatter correction(MSC)and vector normalization(SNV)were applied prior to further preprocessing the spectra with original,first-order derivative(1stD),or second-order derivative(2ndD)treatments.Lastly,the model was optimized through non-smoothing(NS),Norris Derivative filtering(Nd),and Savitzky-Golay filtering(S-G)method.Model stability was evaluated based on correlation coefficients and variance.The predicted contents of each saponin component in the validation set samples were calculated.RESULTS The contents of polyphyllins Ⅰ,Ⅱ,Ⅶ were 0.42-17.98,0.46-10.44,0.23-3.86 mg/g,respectively.The total content ranged from 2.91 to 22.1 mg/g.The optimal parameters of three saponins were achieved when selecting the MSC+2ndD+S-G pretreatment method.The corresponding ratio of line segment length to segment gap was 13∶5,15∶5,11∶5,with correlation coefficients of 0.982,0.930,0.958,respectively.The root mean square errors of calibration(RMSEC)were 0.702,0.797,0.238,and the root mean square errors of prediction(RMSEP)were 1.120,0.835,0.304,respectively.The optimal parameters for the total content were obtained when selecting the MSC+2ndD+NS pretreatment method,with a correlation coefficient of 0.970,a RMSEC of 1.090,and a RMSEP of 1.740.CONCLUSION This accurate and rapid method can be used for detection of saponin contents in P.Polyphylla.
5.Development and application of novel portable heat illness/stroke first-aid kit
Yong-hui ZHANG ; Lin-cheng MI ; Cong-tao GUO ; Qing-ping ZHU ; Qing SONG ; Jing-chun SONG
Chinese Medical Equipment Journal 2025;46(9):108-113
Objective To develop a portable heat illness/stroke first-aid kit for on-site first aid of heat illness patients and verify its application effect.Methods The portable heat illness/stroke first-aid kit was composed of a main box,an adjustable telescopic rod,adjustable shoulder straps,universal rollers and a thermal insulation container.The main box made of aluminum alloy material had the inner surface lined with Oxford cloth,which was equipped with an infrared cochlear thermometer,a nebulizer,first aid medicines,heat stroke medicines,a sun umbrella,a cooling blanket,etc;the adjustable telescopic rod was made of aluminum-magnesium alloy;the adjustable shoulder straps was made of high-density nylon webbing;the universal rollers were rubberized and had wheel brakes;the thermal insulation container was located in the lower storage compartment inside the main box,which used polyurethane(PU)material for thermal insulation.The data on on-site first aid of the patients with moderate heat illness or stroke at some institution from 2019 to 2022 were analyzed retrospectively,with the patients treated with the traditional methods enrolled into a control group and the ones with the first-aid kit into an experimental group.The temperature changes at 0,10,20,30,40,50 and 60 min after the start of treatment were investigated to compare the cooling effects of the two groups.Results The heat illness/stroke first-aid kit lowered the patient temperature effectively during the on-site first aid of the patients with moderate heat illness or stroke,with higher cooling speed and effect than the traditional methods,especially at the early stage of treatment.Conclusion The heat illness/stroke first-aid kit with complete functions and easy operation decreases temperature of heat illness patients efficiently,and can be applicable to the scenarios such as field training and outdoors high-temperature operation.[Chinese Medical Equipment Journal,2025,46(9):108-113]
6.Performance validation and clinical application evaluation of fluorescent magnetic particle chemiluminescence method for the determination of sIgE
Wenqi SHAO ; Mi ZHOU ; Jing ZHU ; Baishen PAN ; Beili WANG ; Wei GUO
Chinese Journal of Preventive Medicine 2025;59(9):1427-1433
To evaluate the analytical performance of a specific IgE (sIgE) quantitative detection system and explore the clinical application effect of dust mite extract and component detection. The fluorescent magnetic particle chemiluminescence method was used to verify the analytical performance of sIgE for house dust mite (D1), dust mite (D2) extracts, and their components (Der p 1, Der p 2, Der p 10, and Der p 23), including precision, limit of blank (LoB), limit of detection (LoD), linear range, and interfering factors. This is a retrospective cohort study. A total of 50 patients with allergic rhinitis and 50 patients with allergic asthma diagnosed at Zhongshan Hospital Affiliated to Fudan University from January 2022 to August 2023 were selected, along with 70 apparently healthy individuals who underwent physical examinations in the hospital as the healthy control group. The positive rates of each sIgE component in the three groups were compared, and the receiver operating characteristic (ROC) curve for diagnosing dust mite allergy was plotted. The results showed that the fluorescent magnetic particle chemiluminescence method for detecting sIgE demonstrated good repeatability and intermediate precision within the range of 0.1-100 kU/L. The LoB, LoD, and linear range all met the specified requirements. Except for Der p 10, which was interfered by the presence of conjugated bilirubin and free bilirubin (exceeding 40 mg/dl), the detection of other allergens was not significantly affected by common endogenous substances. In healthy individuals, 10% had positive sIgE for dustmite extract; in asthmatic and allergic rhinitis patients, the positive rates were 70% and 82%, respectively. The double positive rate of D1 and D2 in the healthy group was 8.6%, while in asthmatic and allergic rhinitis patients, it was 66% and 70%, respectively. When 0.35 kU/L was used as the threshold, the sensitivity of sIgE for dust mite extract to predict component positivity was 100%, specificity was 61.5%, positive predictive value (PPV) was 80.2%, and negative predictive value (NPV) was 100%. When the threshold was optimized to 0.78 kU/L, the sensitivity was 96.8%, specificity was 92.1%, PPV was 95.2%, and NPV was 94.6%. In conclusion, the repeatability, intermediate precision, LoB, LoD, linear range, and anti-interference ability of the fluorescent magnetic particle chemiluminescence method for detecting sIgE meet the requirements of laboratory quality management. This ensures detection quality, meets clinical needs, and can be used for the auxiliary diagnosis of allergic diseases.
7.Mechanism of Lizhong decoction in treating cold-damp diarrhea through network pharmacology,molecular docking and animal experiments
Hao ZHANG ; Wen-wen MI ; Rong-xia GUO ; Chun NIU ; Bao-xia CHEN ; Peng JI ; Yan-ming WEI ; Fang YANG ; Zhen-he LI ; Yong-li HUA
Chinese Pharmacological Bulletin 2025;41(8):1552-1561
Aim To explore the key components and mechanisms of Lizhong decoction in treating rats with cold-damp diarrhea based on network pharmacology,molecular docking technology and animal experiments.Methods By literature review and database collec-tion,the components of Lizhong decoction,therapeutic targets,and the mapping with diarrhea disease targets were conducted to construct an intersection target pro-tein-protein interaction network for screening core tar-gets,and GO and KEGG pathway enrichment analysis was performed to build an"active component-target-pathway"network,followed by molecular docking vali-dation.Forty-eight rats were randomly divided into the normal control group(K),model group(DG),Lizhong decoction group(LZDG),and Pulsatilla decoction group(BTDG).Subsequently,a rat cold-damp diar-rhea model was established using Senna combined with low-temperature high-humidity environment,and the rats were intervened with Lizhong decoction and Pul-satilla decoction.HE staining was used to detect path-ological changes in intestinal tissue,ELISA was em-ployed to measure the levels of peripheral blood IL-6,IL-10,IL-1 β,and TNF-α,and western blot was used to determine the expression of colon tight junction pro-teins.Results Network pharmacology initially identi-fied 125 compounds in Lizhong decoction,5 186 drug target components,438 disease targets,and 60"drug-disease"shared targets.GO and KEGG enrichment a-nalysis showed that signaling pathways such as IL-17 and TNF were highly enriched.Molecular docking in-dicated that the core components of the drug had good binding activity with corresponding key targets.Liz-hong decoction could effectively improve the clinical symptoms of rats with cold-damp diarrhea,and com-pared with the DG group,the diarrhea rate,diarrhea in-dex,and other related indicators also gradually de-creased to normal levels.Compared with the DG group,the LZDG group showed reduced inflammation levels and a recovery in energy metabolism levels.Conclusion It can regulate targets such as MMP9 and IL-17 signaling pathways through multi-components like Calycosin and formononetin to exert its therapeutic effect on cold-damp diarrhea.
8.Latent profile analysis of work withdrawal behaviors of junior nurses and comparison of differences in workplace social capital
Lingjuan YANG ; Yan WANG ; Donglian ZHENG ; Shuping GUO ; Shilin MA ; Doudou HUANG ; Guangli MI
Chinese Journal of Modern Nursing 2025;31(14):1890-1896
Objective:To explore the latent profiles of work withdrawal behaviors of junior nurses and their relationship with workplace social capital.Methods:Using the convenience sampling method, from July to August 2023, 348 junior nurses from five Class Ⅲ and seven ClassⅡ public hospitals in Ningxia Hui Autonomous Region were selected as the research objects. They were investigated with a General Information Questionnaire, the Work Withdrawal Behavior Scale, and the Workplace Social Capital Scale. Latent profile analysis was used to explore the categories of work withdrawal behaviors of junior nurses, and the differences in workplace social capital levels among junior nurses of different categories were compared.Results:A total of 348 questionnaires were recovered online in this survey, and 342 questionnaires were valid, with a valid rate of 98.3%. The work withdrawal behaviors of 342 junior nurses could be divided into three latent profiles, including 246 junior nurses (71.9%) in the low psychological-low behavioral withdrawal group, 81 junior nurses (23.7%) in the high psychological-low behavioral withdrawal group, and 15 junior nurses (4.4%) in the high psychological-high behavioral withdrawal group. The results of the unordered multinomial Logistic regression analysis showed that gender, whether they love nursing work or not, the average number of night shifts per month, the workplace social capital, and working years were the influencing factors of the work withdrawal behaviors of junior nurses ( P<0.05) . There were statistically significant differences in the workplace social capital among the three categories of junior nurses ( H=83.82, P<0.01) . Conclusions:There are three categories of work withdrawal behaviors among junior nurses, and there are differences in workplace social capital among junior nurses of different categories. Nursing managers should intervene and support junior nurses according to the characteristics of different categories to improve their workplace social capital levels.
9.Development and application of novel portable heat illness/stroke first-aid kit
Yong-hui ZHANG ; Lin-cheng MI ; Cong-tao GUO ; Qing-ping ZHU ; Qing SONG ; Jing-chun SONG
Chinese Medical Equipment Journal 2025;46(9):108-113
Objective To develop a portable heat illness/stroke first-aid kit for on-site first aid of heat illness patients and verify its application effect.Methods The portable heat illness/stroke first-aid kit was composed of a main box,an adjustable telescopic rod,adjustable shoulder straps,universal rollers and a thermal insulation container.The main box made of aluminum alloy material had the inner surface lined with Oxford cloth,which was equipped with an infrared cochlear thermometer,a nebulizer,first aid medicines,heat stroke medicines,a sun umbrella,a cooling blanket,etc;the adjustable telescopic rod was made of aluminum-magnesium alloy;the adjustable shoulder straps was made of high-density nylon webbing;the universal rollers were rubberized and had wheel brakes;the thermal insulation container was located in the lower storage compartment inside the main box,which used polyurethane(PU)material for thermal insulation.The data on on-site first aid of the patients with moderate heat illness or stroke at some institution from 2019 to 2022 were analyzed retrospectively,with the patients treated with the traditional methods enrolled into a control group and the ones with the first-aid kit into an experimental group.The temperature changes at 0,10,20,30,40,50 and 60 min after the start of treatment were investigated to compare the cooling effects of the two groups.Results The heat illness/stroke first-aid kit lowered the patient temperature effectively during the on-site first aid of the patients with moderate heat illness or stroke,with higher cooling speed and effect than the traditional methods,especially at the early stage of treatment.Conclusion The heat illness/stroke first-aid kit with complete functions and easy operation decreases temperature of heat illness patients efficiently,and can be applicable to the scenarios such as field training and outdoors high-temperature operation.[Chinese Medical Equipment Journal,2025,46(9):108-113]
10.Therapeutic effect and mechanism by which Trichosanthis Fructus-Allii Macrostemonis Bulbus regulates gut microbiota in a rat model of coronary heart disease
Guanghan SUN ; Zhencong XIE ; Mi SUN ; Yang XU ; Dong GUO
Chinese Journal of Tissue Engineering Research 2025;29(5):917-927
BACKGROUND:A network-based pharmacological approach has identified multifunctional effects of the main bioactive compounds in the Trichosanthis Fructus-Allii Macrostemonis Bulbus on coronary heart disease;however,the mechanism of its therapeutic effect on coronary heart disease has not been fully elucidated. OBJECTIVE:To investigate the role and mechanism of Trichosanthis Fructus-Allii Macrostemonis Bulbus in improving coronary heart disease by regulating the composition of gut microbiota. METHODS:Forty Sprague-Dawley rats were randomly divided into four groups:blank control group(n=10),model group(n=10),positive drug group(n=10),and medicine pair group(n=10).A rat model of coronary heart disease was established by continuous gastric perfusion of fat emulsion and injection of pituitrin.After modeling,rats in the model group were gavaged with distilled water(10 mL/kg)for control,rats in the positive drug group were gavaged with simvastatin 4 mg/kg per day,and rats in the medicine pair group were gavaged with Trichosanthis Fructus-Allii Macrostemonis Bulbus pairs 7.56 g/kg per day.All interventions lasted for 14 days.Electrocardiograms and myocardial pathology were observed,and blood lipid levels were measured.The structure of gut microbiota was analyzed using 16S rDNA sequencing technology. RESULTS AND CONCLUSION:Electrocardiogram results showed ST segment elevation in the model group.There were no significant abnormalities in the electrocardiograms of the positive drug group and medicine pair group.Compared with the blank control group,the levels of total cholesterol,triacylglycerol,and low-density lipoprotein cholesterol were significantly higher in the model group(P<0.05).Compared with the model group,the levels of total cholesterol,triacylglycerol,and low-density lipoprotein cholesterol were significantly lower in the positive drug group and medicine pair group(P<0.05).Compared with the blank control group,focal myocardial cell necrosis was observed in the model group,while partial myocardial cell disarray was observed in the positive drug group and medicine pair group.Compared with the blank control group,the Ace,Shannon,and Chao indices were increased(P<0.05)and the Simpson index was decreased(P<0.05)in the model group,positive drug group and medicine pair group.Compared with the model group,the Ace and Chao indices were decreased(P<0.05),while the Shannon index showed no significant difference(P>0.05)and the Simpson index was also decreased(P<0.05)in the positive drug group and medicine pair group.Compared with the blank control group,the relative abundances of Desulfovibrionia,Muribaculaceae_norank,etc.were increased in the model group,while those of Clostridia,[Eubacterium]_coprostanoligenes_group_norank,etc.were decreased.Compared with the model group,the relative abundances of WPS-2_norank,Muribaculaceae_norank,etc.were increased in the medicine pair group,while those of Clostridia,[Eubacterium]_coprostanoligenes_group_norank,etc.were decreased;the relative abundances of Desulfobacterota,[Eubacterium]_coprostanoligenes_group_norank,etc.were increased in the positive drug group,while those of Firmicutes,Muribaculaceae_norank,etc.were decreased.Compared with the positive drug group,the relative abundances of Desulfobacterota,Bacteroides,etc.were increased in the medicine pair group,while those of Firmicutes,[Eubacterium]_coprostanoligenes_group_norank,etc.were decreased.The LEfSe results showed that the medicine pair group had the highest microbial enrichment,followed by the blank control group and positive drug group,with the model group having the lowest microbial enrichment.To conclude,Trichosanthis Fructus-Allii Macrostemonis Bulbus pairs can improve the development of coronary heart disease by regulating gut microbiota composition,providing new insights for further research and development of Trichosanthis Fructus-Allii Macrostemonis Bulbus pairs.

Result Analysis
Print
Save
E-mail