1.Prospective randomised controlled observation of tympanic chamber injection of gangliosides in the treatment of refractory sudden deafness.
Mengyuan WANG ; Qi DONG ; Yuqin XU ; Yaxiu LI ; Jing LIU ; Jie LI ; Wenyan ZHU ; Wandong SHE
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(3):218-222
Objective:This study aimed to evaluate the therapeutic effect of intratympanic injection of ganglioside in patients with refractory sudden deafness. Methods:A total of 120 patients with sudden deafness, aged 18-65 years, whose onset was within 11-42 days, failed to respond to conventional treatment, and had an average hearing threshold(500-4 000 Hz)>60 dB were selected. They were prospectively and randomly divided into a control group of 61 cases and an experimental group of 59 cases. The control group was treated according to the recommended protocol of the Chinese Medical Association(postauricular injection of methylprednisolone), while the experimental group was treated with intratympanic injection of monosialotetrahexosylganglioside sodium+postauricular injection of methylprednisolone. Both groups were simultaneously administered oral ginkgo biloba extract and citicoline tablets. Hearing was re-examined two weeks after the completion of treatment, and the therapeutic effects of the two different treatment methods were compared and analyzed. Results:The effective rate was 29.51% in the control group and 54.24% in the experimental group(P<0.01). The average hearing threshold improved by 11.57 dB HL in the control group and 22.50 dB HL in the experimental group(P<0.05). Conclusion:The combination of postauricular injection of methylprednisolone and intratympanic injection of ganglioside is more effective than postauricular injection of methylprednisolone alone in the treatment of refractory sudden deafness. The earlier the treatment, the better the therapeutic effect.
Humans
;
Middle Aged
;
Hearing Loss, Sudden/drug therapy*
;
Adult
;
Prospective Studies
;
Young Adult
;
Aged
;
Adolescent
;
Male
;
Female
;
Injection, Intratympanic
;
Gangliosides/administration & dosage*
;
Methylprednisolone/therapeutic use*
;
Treatment Outcome
2.Photon-counting detector CT with virtual monoenergetic imaging in enabling a quadruple low-dose aortic CT angiography protocol: a feasibility study
Ke QI ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Mengyuan ZHANG ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(10):1133-1141
Objective:To assess the viability of reducing radiation dose, contrast media volume, injection flow rate and contrast medium concentration (quadruple low-dose protocol) by utilizing virtual monoenergetic images (VMI) in photon-counting detector CT (PCD-CT) for aortic CT angiography (CTA), while maintaining image quality in comparison to images obtained from energy-integrating detector CT (EID-CT).Methods:From April 2024 to June 2024, a total of 40 participants who underwent aortic CTA on PCD-CT were prospectively enrolled in the experimental group (PCD-CT group), while 40 patients with similar baseline characteristics who had previously undergone aortic CTA using EID-CT were retrospectively selected for the conventional group (EID-CT group). The EID-CT group used a tube voltage of 90 kVp, a contrast media volume of 60 ml of contrast, an injection flow rate of 3 ml/s, and a contrast concentration of 350 mgI/ml; the PCD-CT group used the QuantumPlus mode, with a tube voltage of 140 kVp, a total amount of iodine in the contrast media of 140 mgI/kg, and an injection flow rate=contrast media volume/(delay time+scan time), and a contrast media concentration of 320 mgI/ml. VMIs in PCD-CT group were reconstructed in 5-keV intervals ranging from 45 to 65 keV. The effective radiation dose and contrast injection protocols were recorded and compared between two groups. Objective image quality assessment was performed for each group. CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at five anatomical locations (ascending aorta, aortic arch, descending aorta, abdominal aorta, and right common iliac artery), and image noise was recorded. Subjective image quality was independently evaluated by two readers using a 5-point Likert scale in a blinded manner. Based on data normality, the one-way ANOVA or Kruskal-Wallis test was used for image quality assessment, with Bonferroni-corrected post-hoc analysis for multiple comparisons.Results:There were no significant differences in the baseline characteristics between two groups (all P0.05). The PCD-CT group demonstrated significantly lower effective radiation dose [(3.88±0.65) mSv vs. (5.97±1.15)mSv], contrast media volume [(29.25±4.56) ml vs. 60 ml], and injection rate [(2.65±0.42) ml/s vs. 3 ml/s] than the EID-CT group, with reductions of 35%, 51%, and 12%, respectively (all P0.001). For objective image quality, except for the ascending aortic CT attenuation, the CT attenuation, SNR, and CNR of other vessels in the 55 keV PCD-CT group were comparable to those in the EID-CT group. Additionally, the difference in image noise between these two groups was not statistically significant ( P0.05). Concerning subjective image quality, at 55 keV, the PCD-CT group had similar image noise scores and vessel attenuation scores (both P0.05) and better visualization of renal artery branching ( P=0.001) compared to the EID-CT group. Conclusion:In comparison to EID-CT, the use of a 55 keV image in PCD-CT for aortic CTA has demonstrated reductions in radiation dose, contrast media volume, injection flow rate and contrast medium concentration, while maintaining image quality.
3.Feasibility study of photon counting CT combined with “quadruple lows” technology in head and neck vascular imaging
Mengyuan ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(8):942-948
Objective:To evaluate the feasibility of head and neck vascular imaging using photon-counting detector computed tomography (PCD-CT) combined with a “quadruple lows” protocol—characterized by low contrast media volume, low iodine concentration, low injection rate, and low radiation dose—and to compare the image quality with that obtained by energy-integrating detector CT (EID-CT).Methods:A total of 105 patients with suspected cerebrovascular disease were prospectively enrolled at the First Affiliated Hospital of Zhengzhou University between April and June 2024. Patients were randomly assigned to three groups ( n=35). Group A underwent conventional head and neck CTA using EID-CT. Group B underwent PCD-CT with a protocol involving ultra-low contrast media volume, low iodine concentration, and low injection rate. Group C underwent PCD-CT with the full “quadruple low” protocol. Objective image quality parameters—including CT attenuation, image noise (standard deviation, SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)—were measured at the ascending aorta, common carotid artery, internal carotid artery, vertebral artery, basilar artery, posterior cerebral artery, and middle cerebral artery. Two radiologists independently rated subjective image quality using a 5-point Likert scale. Differences among groups were analyzed using one-way ANOVA and the Kruskal-Wallis test. Results:Compared to Group A [contrast volume: (42.78±6.64)ml], contrast agent volume was significantly reduced in Groups B and C[ (26.26±4.45) ml and (26.54±3.83)ml, respectively], demonstrating reductions of 39% and 38% (both P<0.01). The iodine concentration was 320 mg/ml in Groups B and C, lower than 350 mg/ml in Group A (8.5%). The injection rate was also reduced in Groups B and C [(3.39±0.61) and (3.55±0.51)ml/s, respectively] compared to Group A [(4.28±0.66) ml/s], with reductions of 21% and 17% (both P<0.01). The effective dose (ED) was similar between Groups A and B [(1.40±0.15) vs. (1.40±0.19)mSv, P>0.05], while Group C demonstrated a significantly lower ED [(0.99±0.09) mSv], with a reduction of 30% compared to Group A and 29% compared to Group B (both P<0.01).In terms of objective image quality, significant differences in image noise (SD) were observed among the three groups at the vertebral artery, internal carotid artery, posterior cerebral artery, and middle cerebral artery (all P<0.05). Groups B and C showed significantly lower SD compared to Group A ( P<0.05), with no significant difference between B and C ( P>0.05). SNR was significantly higher in Groups B and C than in Group A at multiple vascular segments (all P<0.05). CNR differed only at the internal carotid artery, where Groups B and C demonstrated superior performance compared to Group A ( P<0.05).Subjective image quality scores showed no significant difference between Groups A and C ( P>0.05), while Group B had significantly higher scores than both A and C ( P<0.05). All images were deemed diagnostically acceptable. Conclusion:Compared with conventional EID-CT, PCD-CT combined with a “quadruple lows” protocol enables substantial reductions in contrast media and radiation dose while further improving image quality in head and neck CTA.
4.Photon-counting detector-CT combined with"four-lows"protocol for coronary CT angiography
Weiting ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Mengyuan ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Yonggao ZHANG ; Jie LIU
Chinese Journal of Medical Imaging Technology 2025;41(6):976-980
Objective To observe the feasibility of photon-counting detector(PCD)-CT combined with"four-lows"protocol(low contrast agent concentration,low contrast dose,low contrast agent flow rate,low radiation dose)for coronary CT angiography(CCTA).Methods Totally 106 patients with suspected coronary artery disease were prospectively enrolled and randomized into energy-integrating detector(EID)-CCTA(group A,using conventional scanning protocol,n=52)or PCD-CCTA(group B,using"four-lows"scanning protocol,n=54)groups and underwent relative examinations.The radiation dose,subjective and objective evaluation results of imaging quality were compared between groups.Results The contrast agent dose and flow rate,volume CT dose index,dose length product and effective dose in group B were all lower than those in group A(all P<0.001).The subjective scores in group B were higher than in group A(5[4,5]vs.4[4,5],Z=-2.310,P=0.021).Compared with group A,CT value,signal-to-noise ratio and contrast-to-noise ratio of aortic root and most of the main branches of coronary arteries increased in group B,while standard deviation of CT value decreased(all P<0.05).Conclusion PCD-CT combined with"four-lows"protocol could be used for CCTA,which could improve imaging quality and reduce contrast agent usage and radiation dose.
5.Long-term efficacy analysis of narrow-margin hepatectomy intraoperative radiotherapy for hepatocellular carcinoma
Mengyuan LI ; Yanling WU ; Liming WANG ; Fan WU ; Shulian WANG ; Yueping LIU ; Yongwen SONG ; Ning LI ; Yuan TANG ; Hao JING ; Hui FANG ; Ningning LU ; Shunan QI ; Zhuanbo YANG ; Siye CHEN ; Yexiong LI ; Jianxiong WU ; Qinfu FENG ; Yirui ZHAI ; Bo CHEN
Cancer Research and Clinic 2025;37(5):343-350
Objective:To investigate the long-term efficacy, safety and prognostic factors of intraoperative radiotherapy (IORT) for narrow-margin (resection margin < 1 cm) hepatectomy in patients with hepatocellular carcinoma (HCC) during radical surgery.Methods:A retrospective cohort study was conducted. The data of primary HCC patients undergoing radical surgery and narrow-margin hepatectomy IORT in the Cancer Hospital of the Chinese Academy of Medical Sciences from November 2009 to February 2019 were collected. IORT applied 6 MeV or 9 MeV electron beams and a single irradiation was given to the margin. Kaplan-Meier method was used for the overall survival (OS) and disease-free survival (DFS) analysis; log-rank test was used for survival comparison among subgroups. The recurrence patterns and adverse reactions were recorded. Univariate and multivariate Cox proportional hazards models were used to analyze the factors influencing the OS and DFS.Results:A total of 64 patients were enrolled, with the median age [ M ( Q1, Q3)] of 57 years (49, 63) years. All patients included 55 males (85.9%) and 9 females (14.1%). The median dose of IORT was 15 Gy (range: 12-17 Gy). The median follow-up time was 83.3 (64.4, 91.9) months. The 1-year, 3-year, 5-year, 7-year, 10-year OS rates were 90.4%, 80.6%, 75.5%, 71.4% and 47.6%, respectively; the 1-year, 3-year, 5-year, 7-year,10-year DFS rates were 77.8%, 68.1%, 59.6%, 57.6% and 38.4%, respectively. Univariate Cox regression analysis indicated that preoperative serum alpha-fetoprotein (AFP) > 400 ng/ml was an independent risk factor for poor OS (> 400 ng/ml vs. ≤ 400 ng/ml: HR = 6.57, 95% CI: 2.16-19.96, P < 0.001), while not the independent influencing factor of poor DFS ( HR = 1.71, 95% CI: 0.65-4.52, P = 0.277). The age ≤ 60 years or not, gender, viral hepatitis or not, American Joint Committee on Cancer stage, tumor diameter (> 5 cm or not), tumor number, degree of tumor differentiation, microvascular invasion or not, microsatellite nodules or not, anatomical liver resection or not, and the dose of IORT ≤15 Gy or not were not the independent influencing factors of poor OS and DFS (all P > 0.05). Kaplan-Meier method analysis showed that patients with preoperative serum AFP ≤ 400 ng/ml (48 cases) had better OS compared with those with preoperative serum AFP>400 ng/ml (16 cases) (5-year OS rate: 84.8% vs. 44.9%; 7-year OS rate: 79.9% vs.37.4%), and the difference was statistically significant ( P = 0.002). There was no statistically significant difference in the DFS between the 2 groups ( P = 0.134). During the follow-up, 28 patients (43.8%) relapsed, including 17 cases (26.6%) of early recurrence and 11 cases (17.2%) of late recurrence. No marginal recurrence was observed. There were 22 cases (34.4%) of intrahepatic recurrence alone, 2 cases (3.1%) of extrahepatic recurrence and 4 cases (6.3%) of stimutaneous recurrence inside and outside the liver. The 1-, 3-, 5- and 7-year cumulative recurrence rates inside the liver were 19.0%, 27.2%, 37.4% and 39.3% respectively, and the cumulative recurrence rates outside the liver were 6.4%, 8.0%, 9.6% and 9.6% respectively. There were no adverse reactions above grade 3 in the entire group. There were no surgery-related deaths within 30 d after the operation, and no radiation-induced liver disease occurred. Conclusions:Narrow-margin IORT helps HCC patients receiving hepatectomy to achieve favorable long-term survival and adverse reactions are tolerable. It can be used as a safe and effective adjuvant therapy alternative.
6.ARID1A IDR targets EWS-FLI1 condensates and finetunes chromatin remodeling.
Jingdong XUE ; Siang LV ; Ming YU ; Yixuan PAN ; Ningzhe LI ; Xiang XU ; Qi ZHANG ; Mengyuan PENG ; Fang LIU ; Xuxu SUN ; Yimin LAO ; Yanhua YAO ; Juan SONG ; Jun WU ; Bing LI
Protein & Cell 2025;16(1):64-71
7.Deep learning image reconstruction algorithm in brain CT perfusion imaging with low tube voltage and reduced contrast agent dosage
Mengyuan ZHANG ; Luotong WANG ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Jiong ZHANG ; Songwei YUE ; Jianbo GAO ; Jie LIU
Chinese Journal of Medical Imaging Technology 2025;41(5):799-805
Objective To observe the value of deep learning image reconstruction(DLIR)algorithm in brain CT perfusion(CTP)using a protocol of 70 kVp and 40 ml contrast agent dose.Methods Totally 105 patients with suspected acute ischemic stroke(AIS)were prospectively enrolled and randomly divided into 3 groups,who underwent standard dose CTP scanning with 80 kVp and 150 mA combined with reconstruction as adaptive statistic iterative reconstruction V(ASIR-V)at 50%level(CN group,n=35),low dose(LD)scanning with 70 kVp and 100 mA combined with DLIR reconstruction at the highest level(DLIR-H)(LD group,n=35),or ultra-low dose(ULD)scanning with 70 kVp and 70 mA combined with DLIR-H reconstruction(ULD group,n=35).Radiation doses were compared among 3 groups.CT values and standard deviations(SDCT)of ROI of gray matter and white matter in the frontal,parietal and temporal lobes were measured.Signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)between gray and white matter were calculated and compared among groups.Then pseudo-color images of cerebral blood volume(CBV),cerebral blood flow(CBF),mean transit time(MTT)and time to maximum of the tissue residual function(Tmax)were generated.The imaging quality of CTP pseudo-color images was evaluated,and the compatibility of the subjective scores within every kind of CTP pseudo-color images were assessed using Kappa test.Quantitative perfusion parameters were measured and compared among groups.Results Compared with CN group,both LD and ULD groups demonstrated significantly reduced volume CT dose index(CTDIvol),dose-length product(DLP)and effective dose(ED)(all adjusted P<0.05).In ULD group,SDCT of white matter in frontal,parietal and temporal lobes were higher than those in CN group,and SDCT of white matter in parietal lobe was also higher than that in LD group(all adjusted P<0.05).No significant difference of SDCT of gray matter was observed among groups(all P>0.05).SNR of white matter in parietal and temporal lobes in both LD and ULD groups were lower than those in CN group(all P<0.05),while no significant difference of SNR of white matter in frontal lobe,nor of gray matter in frontal,parietal and temporal lobes was found among groups(all P>0.05).CNR of gray and white matter in the frontal,parietal and temporal lobes were not significantly different among groups(all P>0.05).High consistency of inter-observer subjective scores of CBV maps,CBF maps and Tmax maps(Kappa of 0.623,0.644 and 0.638,respectively)were noticed,which of MTT maps had moderate consistency(Kappa=0.560).No significant difference of intra-obsever subjective scores of CTP pseudo-color images was found among groups(all P>0.05).CBV,CBF,MTT and Tmax values of gray and white matter in frontal,parietal and temporal lobes were not significantly different among groups(all P>0.05).Conclusion DLIR algorithm applicated in low radiation dose and reduced contrast agent dosage might ensure imaging quality.
8.Deep learning image reconstruction algorithm in brain CT perfusion imaging with low tube voltage and reduced contrast agent dosage
Mengyuan ZHANG ; Luotong WANG ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Jiong ZHANG ; Songwei YUE ; Jianbo GAO ; Jie LIU
Chinese Journal of Medical Imaging Technology 2025;41(5):799-805
Objective To observe the value of deep learning image reconstruction(DLIR)algorithm in brain CT perfusion(CTP)using a protocol of 70 kVp and 40 ml contrast agent dose.Methods Totally 105 patients with suspected acute ischemic stroke(AIS)were prospectively enrolled and randomly divided into 3 groups,who underwent standard dose CTP scanning with 80 kVp and 150 mA combined with reconstruction as adaptive statistic iterative reconstruction V(ASIR-V)at 50%level(CN group,n=35),low dose(LD)scanning with 70 kVp and 100 mA combined with DLIR reconstruction at the highest level(DLIR-H)(LD group,n=35),or ultra-low dose(ULD)scanning with 70 kVp and 70 mA combined with DLIR-H reconstruction(ULD group,n=35).Radiation doses were compared among 3 groups.CT values and standard deviations(SDCT)of ROI of gray matter and white matter in the frontal,parietal and temporal lobes were measured.Signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)between gray and white matter were calculated and compared among groups.Then pseudo-color images of cerebral blood volume(CBV),cerebral blood flow(CBF),mean transit time(MTT)and time to maximum of the tissue residual function(Tmax)were generated.The imaging quality of CTP pseudo-color images was evaluated,and the compatibility of the subjective scores within every kind of CTP pseudo-color images were assessed using Kappa test.Quantitative perfusion parameters were measured and compared among groups.Results Compared with CN group,both LD and ULD groups demonstrated significantly reduced volume CT dose index(CTDIvol),dose-length product(DLP)and effective dose(ED)(all adjusted P<0.05).In ULD group,SDCT of white matter in frontal,parietal and temporal lobes were higher than those in CN group,and SDCT of white matter in parietal lobe was also higher than that in LD group(all adjusted P<0.05).No significant difference of SDCT of gray matter was observed among groups(all P>0.05).SNR of white matter in parietal and temporal lobes in both LD and ULD groups were lower than those in CN group(all P<0.05),while no significant difference of SNR of white matter in frontal lobe,nor of gray matter in frontal,parietal and temporal lobes was found among groups(all P>0.05).CNR of gray and white matter in the frontal,parietal and temporal lobes were not significantly different among groups(all P>0.05).High consistency of inter-observer subjective scores of CBV maps,CBF maps and Tmax maps(Kappa of 0.623,0.644 and 0.638,respectively)were noticed,which of MTT maps had moderate consistency(Kappa=0.560).No significant difference of intra-obsever subjective scores of CTP pseudo-color images was found among groups(all P>0.05).CBV,CBF,MTT and Tmax values of gray and white matter in frontal,parietal and temporal lobes were not significantly different among groups(all P>0.05).Conclusion DLIR algorithm applicated in low radiation dose and reduced contrast agent dosage might ensure imaging quality.
9.Photon-counting detector CT with virtual monoenergetic imaging in enabling a quadruple low-dose aortic CT angiography protocol: a feasibility study
Ke QI ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Mengyuan ZHANG ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(10):1133-1141
Objective:To assess the viability of reducing radiation dose, contrast media volume, injection flow rate and contrast medium concentration (quadruple low-dose protocol) by utilizing virtual monoenergetic images (VMI) in photon-counting detector CT (PCD-CT) for aortic CT angiography (CTA), while maintaining image quality in comparison to images obtained from energy-integrating detector CT (EID-CT).Methods:From April 2024 to June 2024, a total of 40 participants who underwent aortic CTA on PCD-CT were prospectively enrolled in the experimental group (PCD-CT group), while 40 patients with similar baseline characteristics who had previously undergone aortic CTA using EID-CT were retrospectively selected for the conventional group (EID-CT group). The EID-CT group used a tube voltage of 90 kVp, a contrast media volume of 60 ml of contrast, an injection flow rate of 3 ml/s, and a contrast concentration of 350 mgI/ml; the PCD-CT group used the QuantumPlus mode, with a tube voltage of 140 kVp, a total amount of iodine in the contrast media of 140 mgI/kg, and an injection flow rate=contrast media volume/(delay time+scan time), and a contrast media concentration of 320 mgI/ml. VMIs in PCD-CT group were reconstructed in 5-keV intervals ranging from 45 to 65 keV. The effective radiation dose and contrast injection protocols were recorded and compared between two groups. Objective image quality assessment was performed for each group. CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at five anatomical locations (ascending aorta, aortic arch, descending aorta, abdominal aorta, and right common iliac artery), and image noise was recorded. Subjective image quality was independently evaluated by two readers using a 5-point Likert scale in a blinded manner. Based on data normality, the one-way ANOVA or Kruskal-Wallis test was used for image quality assessment, with Bonferroni-corrected post-hoc analysis for multiple comparisons.Results:There were no significant differences in the baseline characteristics between two groups (all P0.05). The PCD-CT group demonstrated significantly lower effective radiation dose [(3.88±0.65) mSv vs. (5.97±1.15)mSv], contrast media volume [(29.25±4.56) ml vs. 60 ml], and injection rate [(2.65±0.42) ml/s vs. 3 ml/s] than the EID-CT group, with reductions of 35%, 51%, and 12%, respectively (all P0.001). For objective image quality, except for the ascending aortic CT attenuation, the CT attenuation, SNR, and CNR of other vessels in the 55 keV PCD-CT group were comparable to those in the EID-CT group. Additionally, the difference in image noise between these two groups was not statistically significant ( P0.05). Concerning subjective image quality, at 55 keV, the PCD-CT group had similar image noise scores and vessel attenuation scores (both P0.05) and better visualization of renal artery branching ( P=0.001) compared to the EID-CT group. Conclusion:In comparison to EID-CT, the use of a 55 keV image in PCD-CT for aortic CTA has demonstrated reductions in radiation dose, contrast media volume, injection flow rate and contrast medium concentration, while maintaining image quality.
10.Feasibility study of photon counting CT combined with “quadruple lows” technology in head and neck vascular imaging
Mengyuan ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(8):942-948
Objective:To evaluate the feasibility of head and neck vascular imaging using photon-counting detector computed tomography (PCD-CT) combined with a “quadruple lows” protocol—characterized by low contrast media volume, low iodine concentration, low injection rate, and low radiation dose—and to compare the image quality with that obtained by energy-integrating detector CT (EID-CT).Methods:A total of 105 patients with suspected cerebrovascular disease were prospectively enrolled at the First Affiliated Hospital of Zhengzhou University between April and June 2024. Patients were randomly assigned to three groups ( n=35). Group A underwent conventional head and neck CTA using EID-CT. Group B underwent PCD-CT with a protocol involving ultra-low contrast media volume, low iodine concentration, and low injection rate. Group C underwent PCD-CT with the full “quadruple low” protocol. Objective image quality parameters—including CT attenuation, image noise (standard deviation, SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)—were measured at the ascending aorta, common carotid artery, internal carotid artery, vertebral artery, basilar artery, posterior cerebral artery, and middle cerebral artery. Two radiologists independently rated subjective image quality using a 5-point Likert scale. Differences among groups were analyzed using one-way ANOVA and the Kruskal-Wallis test. Results:Compared to Group A [contrast volume: (42.78±6.64)ml], contrast agent volume was significantly reduced in Groups B and C[ (26.26±4.45) ml and (26.54±3.83)ml, respectively], demonstrating reductions of 39% and 38% (both P<0.01). The iodine concentration was 320 mg/ml in Groups B and C, lower than 350 mg/ml in Group A (8.5%). The injection rate was also reduced in Groups B and C [(3.39±0.61) and (3.55±0.51)ml/s, respectively] compared to Group A [(4.28±0.66) ml/s], with reductions of 21% and 17% (both P<0.01). The effective dose (ED) was similar between Groups A and B [(1.40±0.15) vs. (1.40±0.19)mSv, P>0.05], while Group C demonstrated a significantly lower ED [(0.99±0.09) mSv], with a reduction of 30% compared to Group A and 29% compared to Group B (both P<0.01).In terms of objective image quality, significant differences in image noise (SD) were observed among the three groups at the vertebral artery, internal carotid artery, posterior cerebral artery, and middle cerebral artery (all P<0.05). Groups B and C showed significantly lower SD compared to Group A ( P<0.05), with no significant difference between B and C ( P>0.05). SNR was significantly higher in Groups B and C than in Group A at multiple vascular segments (all P<0.05). CNR differed only at the internal carotid artery, where Groups B and C demonstrated superior performance compared to Group A ( P<0.05).Subjective image quality scores showed no significant difference between Groups A and C ( P>0.05), while Group B had significantly higher scores than both A and C ( P<0.05). All images were deemed diagnostically acceptable. Conclusion:Compared with conventional EID-CT, PCD-CT combined with a “quadruple lows” protocol enables substantial reductions in contrast media and radiation dose while further improving image quality in head and neck CTA.

Result Analysis
Print
Save
E-mail