1.Cage design-centric glider approach to full-endoscopic lumbar fusion: optimizing nerve root protection in facet-sparing and facet-resecting techniques
Yu-Chia HSU ; Hao-Chun CHUANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Asian Spine Journal 2026;20(2):343-353
Endoscopic transforaminal lumbar interbody fusion (TLIF) offers substantial advantages in the management of degenerative spinal diseases, including accelerated postoperative recovery. However, its technical complexity and steep learning curve pose risks for nerve root injury. Optimizing nerve root protection in full-endoscopic facet-sparing TLIF (FE fs-TLIF) and full-endoscopic facet-resecting TLIF (FE fr-TLIF) is essential for enhancing surgical safety. This study aimed to improve the nerve root protection in FE fs-TLIF and FE fr-TLIF by optimizing cage glider selection and insertion techniques based on the specific cage shape—banana-shaped or bullet-shaped. The goal was to ensure safe cage positioning and mitigate nerve root injury during discectomy, endplate preparation, and cage insertion. These strategies were validated through cadaveric simulations and clinical implementation. In FE fr-TLIF utilizing bullet-shaped (straight) cages, one-tip and two-tip cage gliders effectively protected the traversing nerve root by facilitating medial cage entry, thereby minimizing irritation of the exiting nerve root. Conversely, in FE fr-TLIF with banana-shaped cages, the lateral tilt of the cage holder during implantation required the use of a two-tip cage glider to protect the traversing and exiting nerve roots, thereby mitigating the potential risk of nerve irritation. In FE fs-TLIF, a one-tip cage glider is preferred for safeguarding the exiting nerve root, while the traversing root is inherently protected by the medial wall of the facet joint. The use of a two-tip cage glider in FE fs-TLIF can cause injury to the nerve root during glider insertion. In addition to the selection of cage gliders, improper cage insertion steps can also contribute to postoperative neurapraxia. The appropriate selection of cage gliders with corresponding insertion techniques is critical for nerve root protection in endoscopic TLIF. Tailoring these choices to the specific approach (FE fs-TLIF or FE fr-TLIF) and cage type (banana or bullet) enhances surgical safety and clinical outcomes.
2.Determination of formaldehyde in the workplace air using the length detector tube method
Qiuyan XU ; Zuokan LIN ; Weifeng RONG ; Ruibo MENG ; Jing YUAN ; Jiawen HU
China Occupational Medicine 2026;53(2):233-237
Objective To establish a rapid on-site detection method for detecting formaldehyde in workplace air using the length detector tube method. Methods The length detector tube was applied to detect the level of formaldehyde in workplace air. Performance indicators, including accuracy, precision, stability, and interference susceptibility, of the method were validated. Results The formaldehyde length detector tube can determine formaldehyde mass concentrations ranging from 0.05 to 4.00 mg/m³ at 25 ℃, covering 0.5 to 2.0 times the occupational exposure limit for formaldehyde (0.50 mg/m³). Under conditions of 10 to 35 ℃ and relative humidity <80.00%, the average recovery was 93.33%-101.67%, and all the within-run method ranges from -21.67% to 20.00%, and all the relative standard deviations were <10.00%. The average decrease rate of formaldehyde in gas bags within 24 hours ranged from -8.33% to 8.33%. Common coexisting substances in workplaces, such as methanol, benzene, toluene, hydrogen chloride, and nitrogen dioxide, did not interfere with the measurements. However, aldehydes and ketones might cause overestimation. Conclusion The formaldehyde length detector tube method demonstrates high accuracy and specificity for detecting formaldehyde in air, making it suitable for rapid monitoring of formaldehyde in workplace air.
3.Comparison of the Prognostic Value Between CHA2DS2-VASc and R2CHA2DS2-VASc Scores in Patients With Atrial Fibrillation and Heart Failure
Yile LIN ; Shuyan ZHANG ; Zeyue CHEN ; Zhiyu HE ; Dunzheng HAN ; Haobin ZHOU ; Hongliang XUE ; MOK TOI-MENG ; Chen LIU ; Woliang YUAN ; Yugang DONG ; Ailan CHEN
Chinese Circulation Journal 2025;40(7):674-680
Objectives:To investigate the prognostic value of the CHA2DS2-VASc and R2CHA2DS2-VASc scores in patients with atrial fibrillation(AF)and heart failure(HF).Methods:Patients with AF and HF from hospitals diagnosed by the Heart Failure Center in Guangdong Province between January 2017 and December 2021 were selected.Major adverse cardiovascular events(MACE)were used as the follow-up endpoint.Statistical methods such as the area under the receiver operating characteristic(ROC)curve(AUC),net reclassification index(NRI),and integrated discrimination improvement(IDI)were applied to evaluate the predictive value of the CHA2DS2-VASc and R2CHA2DS2-VASc scores in patients with AF and HF.Results:A total of 1 839 patients were enrolled in this study,comprising 703 patients in the MACE group and 1 136 patients in the non-MACE group.Compared with the non-MACE group,the MACE group exhibited significantly advanced age,higher prevalence of New York Heart Association class Ⅳ and coronary artery disease,lower diastolic blood pressure and estimated glomerular filtration rate levels,and elevated serum N-terminal pro-B-type natriuretic peptide concentrations(all P<0.05).Additionally,significantly lower proportions of patients in the MACE group received angiotensin-converting enzyme inhibitors/angiotensin receptor blockers/angiotensin receptor-neprilysin inhibitors,beta-blockers,mineralocorticoid receptor antagonists,or anticoagulant therapy(all P<0.05).Multivariable logistic regression analysis revealed that each 1-point increment in both CHA2DS2-VASc and R2CHA2DS2-VASc scores was associated with approximately 10%increased risk of MACE.ROC curve analysis demonstrated that the AUC values for predicting MACE in AF patients with HF were 0.555(95%CI:0.528-0.582,P<0.001)for CHA2DS2-VASc and 0.576(95%CI:0.549-0.608,P<0.001)for R2CHA2DS2-VASc,indicating marginally superior discriminatory capacity of the R2CHA2DS2-VASc score.Delong's test confirmed statistically significant differences between the two scoring systems(P=0.001).The R2CHA2DS2-VASc score demonstrated a NRI of 0.259(95%CI:0.166-0.352,P<0.001)and an IDI of 0.007(95%CI:0.005-0.010,P<0.001)compared with the conventional CHA2DS2-VASc score.Although the R2CHA2DS2-VASc score exhibited slightly better predictive accuracy and outcome discrimination capacity than the original scoring system,both scores demonstrated suboptimal clinical predictive performance.Conclusions:Both the R2CHA2DS2-VASc and CHA2DS2-VASc scores show suboptimal performance for predicting the risk of MACE in patients with AF and HF,and the predicting performance of R2CHA2DS2-VASc score is marginally superior to CHA2DS2-VASc score in this patient cohort.
4.Advances in the pathology of digestive system diseases in China over the past ten years: retrospect and prospect
Yuan LIN ; Jinghuan LYU ; Hongxue MENG ; Wei SANG ; Xueqin TAO ; Weixun ZHOU
Chinese Journal of Pathology 2025;54(2):103-108
The incidence of digestive system diseases is high. So digestive system pathology is widely concerned. In the past 10 years, Chinese pathologists insist on hard work and have made significant progress. This article reviews the research and practice progress in digestive system tumors and non-tumors in the past 10 years, including the establishment of diagnostic criteria for gastrointestinal tract, hepatobiliary and pancreatic diseases, the establishment and classification of new diseases with special morphology, the classification and standard update of gastrointestinal and pancreatic neuroendocrine tumors, the progress of molecular pathology, and non-tumor lesions of the digestive system. The future development trend of digestive system pathology is also prospected.
5.Investigation on patient experience and willingness to use internet diagnosis and treatment and analysis of influencing factors
Wensi ZHANG ; Meng YUAN ; Sitong LIN ; Chengcheng LI
Modern Hospital 2025;25(3):422-426
Objective In order to investigate the patients'medical experiences,willingness to use online diagnosis and treatment in the context of"Internet+medical health",and the factors influencing these choice of medical channels.Methods We conducted an online and offline sampling survey through a questionnaire.1 215 questionnaires were distributed,and 1 010 were valid.After looking at the basic details of the survey participants,we used a logistic regression model to find out what affects patients'willingness to see a doctor online.Results Whether patients have solved their own problem,and the degree of help on the Internet play a significant role in the willingness to recommend Internet diagnosis and treatment.In addition,with the de-crease of age,the improvement of education level,the increase of economic development level of the city where the respondents live,and the decrease of medical expenditure in the past year,residents'willingness to use Internet diagnosis and treatment will show a gradually increasing trend.Conclusion Internet diagnosis and treatment in the future still need to further meet the needs of multi-group medical services,improve and perfect service quality and medical insurance management,to achieve"full node"coverage,"full chain"supervision.
6.Study on protective effect of electroacupuncture combined with Yupingfengsan Jiawei on acute lung injury in rats
Jialei MENG ; Xu HUA ; Yuhui MA ; Huan GENG ; Lin YUAN ; Ming LEI
Chinese Journal of Immunology 2025;41(6):1447-1454
Objective:To explore protective effect and possible mechanism of electroacupuncture at Zusanli combined with Yupingfengsan Jiawei on rats with acute lung injury.Methods:A total of 50 Wistar rats were randomly divided into control group,model group,Yupingfengsan Jiawei group(YPFSJW),electroacupuncture group(EA),acupuncture-medicine combination group(EA+YPFSJW),and acute lung injury model rats were constructed by intraperitoneal injection of lipopolysaccharide except control group.Lung tissue injury,oxidative damage and inflammatory factors were detected by wet/dry weight ratio,HE staining,TUNEL staining,myeloperoxidase(MPO),malondialdehyde(MDA),superoxide dismutase(SOD)and ELISA.qRT-PCR,immunohistochemical staining and Western blot were used to detect mRNA and related protein expressions.Results:Compared with control group,structure of lung tissue in model group was significantly damaged,alveolar wall was thickened,accompanied by pathological damage such as congestion and inflammatory cell infiltration,wet/dry ratio of lung tissue,apoptosis rate,inflammatory factors,oxidative damage level and mRNA expressions were significantly increased,and protein expressions of TLR4,MyD88,p-p65 and p-IκBα were significantly increased(P<0.05);compared with model group,Yupingfengsan Jiawei group,electroacupuncture group and acupuncture-medicine combination group had less inflammatory cell infiltration and congestion in lung tissue,wet/dry weight ratio of lung tissue,cell apopto-sis rate,inflammatory factors,oxidative damage levels and mRNA expressions were decreased,and TLR4,MyD88,p-p65,p-IκBαprotein expressions were decreased(P<0.05);compared with Yupingfengsan Jiawei group and electroacupuncture group,lung tissue alveolar structure of combined acupuncture and medicine group was relatively complete and clear,wet/dry weight ratio of lung tissue,cell apoptosis rate,inflammatory factors,oxidative damage levels and mRNA expressions were decreased,TLR4,MyD88,p-p65,p-IκBα protein expressions were decreased(P<0.05).Conclusion:Electroacupuncture combined with Yupingfengsan Jiawei can reduce acute lung injury in rats,whose mechanism may be related to regulation of protein levels related to NF-κB signaling pathway.
7.Dosimetry effect of fluence smoothing in Monaco Treatment Planning System for short-course volumetric modulated arc therapy of preoperative rectal cancer
Yao XIAO ; De-li ZHOU ; Kun-pu SU ; Lin-shan LI ; Meng-yuan SI ; Yan-hai LIU ; Chuan CHEN
Chinese Medical Equipment Journal 2025;46(5):48-53
Objective To investigate the dosimetric differences in preoperative short-course volumetric modulated arc therapy(VMAT)for rectal cancer using different fluence smoothing(FS)levels in the Monaco Treatment Planning System(Monaco TPS).Methods Twenty rectal cancer patients who received preoperative neoadjuvant short-course VMAT at some hospital from September 2021 to December 2022 were retrospectively selected.Four groups of radiotherapy plans were formulated using the Monaco TPS for each case,which were classified into an off group,a low group,a medium group and a high group based on the FS levels.Then the four groups were compared in terms of the dosimetric parameters,monitor unit and number of the segments in the planning target volume(PTV)and organ at risk(OAR).Statistical analysis was performed using SPSS 27.0 software.Results All the four groups had the doses to the target volume meeting clinical requirements,which had no significant differences in the doses to 5%(D5%)and 95%(D95%)to the target volume and the maximum dose(Dmax),minimum dose(Dmin),mean dose(Dmean)and conformity index(all P>0.05).Statistical differences were found between the homogeneity indexes of the four groups(P<0.05),with the medium group behaving the best.The number of the segments rose while the mornitor units decreased siginificantly with the increase of FS levels,with the differences being statistically significant(P<0.05).There were no significant differences between the V25,V20,V15 and V10 of the small intestine,the V25 and V20 of the bladder and the V15 and V10 of the left and right femur(all P>0.05).Conclusion In preoperative short-course VMAT for rectal cancer,clinical requirements can be met with different FS levels in the Monaco TPS,and medium-level FS results in optimal overall dose distribution in terms of treatment planning.[Chinese Medical Equipment Journal,2025,46(5):48-53]
8.Application of sterilization of vas deferens by irrigation in clinic
Hong-hua WANG ; Hong-ying YU ; Ying-juan CAO ; Jun ZHU ; Yan WANG ; Meng-yuan LIN
National Journal of Andrology 2025;31(8):713-716
Objective:To explore the clinical effects of sterilization of vas deferens by irrigation in clinic.Methods:Eighty-six male patients with voluntary sterilization were divided into control group(usual vasectomy,n=50)and observation group(sterilization of vas deferens by irrigation,n=36).The age,testicular volume,preoperative average concentration of spern,serum testosterone level,recovery duration evaluated by Artificial Obstruction Azoospermia(AOA)and degree of satisfaction were compared between the two groups of patients.Results:There were significant differences in recovery duration,degree of satisfaction between the two groups(P<0.05).And there was no significant difference in age([32.0±5.5]years vs[31.0±6.3]years),testicular volume([16.0±4.8]mL vs[17.0±4.4]mL),preopera-tive average concentration of sperm([39.6±20.2]× 106/mL vs[40.2±22.6]× 106/mL)and levels of blood testosterone([4.3±0.8]ng/mL vs[4.4±0.8]ng/mL).There was significant difference in patency rate between the two sides of testicular ducts(91.7%vs 83.3%,P<0.05).Conclusion:The method of sterilization of vas deferens by irrigation is worth popularizing in clinic.
9.Advances in the pathology of digestive system diseases in China over the past ten years: retrospect and prospect
Yuan LIN ; Jinghuan LYU ; Hongxue MENG ; Wei SANG ; Xueqin TAO ; Weixun ZHOU
Chinese Journal of Pathology 2025;54(2):103-108
The incidence of digestive system diseases is high. So digestive system pathology is widely concerned. In the past 10 years, Chinese pathologists insist on hard work and have made significant progress. This article reviews the research and practice progress in digestive system tumors and non-tumors in the past 10 years, including the establishment of diagnostic criteria for gastrointestinal tract, hepatobiliary and pancreatic diseases, the establishment and classification of new diseases with special morphology, the classification and standard update of gastrointestinal and pancreatic neuroendocrine tumors, the progress of molecular pathology, and non-tumor lesions of the digestive system. The future development trend of digestive system pathology is also prospected.
10.A Sensitive Ion Chromatography-Inductively Coupled Plasma Mass Spectrometry Method for Analysis of Iodine Speciation in Environmental Water Samples
Huan JIANG ; Ning CHEN ; Yan-Yun WANG ; Yu-Kun FAN ; Meng-Ting ZHANG ; Lu-Yuan ZHANG ; Xiao-Lin HOU
Chinese Journal of Analytical Chemistry 2025;53(2):278-288
Iodine speciations in aquatic environments are affected by dissolved oxygen,redox potential,microbial activity,organic matter decomposition,light reaction,etc.Accurate quantification of iodine speciation can not only help to understand the geochemical cycle of iodine,but also help to trace and study environmental processes.Based on the combination of ion chromatography(IC)and inductively coupled plasma mass spectrometry(ICP-MS),a rapid and sensitive method was established for determining the speciations of iodine in environmental water samples including seawater,river water,lake water,rainwater,groundwater,etc.The results presented here showed that IO3?and I?in seawater were quickly separated and measured within 120 s when using guard column AG22 and 8 mmol/L(NH4)2CO3 as the mobile phase.While for lake water,river water and precipitation samples with high soluble organically bond iodine(SOI),an AS22 separation column(250 mm×4 mm)connected with a guard column and using 50 mmol/L(NH4)2CO3 as mobile phase could effectively separate unknown SOI from IO3? to achieve accurate quantification of IO3?.For accurate correction of iodine measurement signal fluctuations,133Cs was directly added to the(NH4)2CO3 mobile phase as an internal standard.The SOI content was calculated by the total iodine concentrations minus the sum of IO3?and I?.The precision of the established iodine speciation analytical method was better than 3.5%,and the standard addition experiment showed that the analytical method was accurate.When the injection volume was 25 μL,the detection limits were 0.011?0.025 μg/L for IO3? and 0.023?0.031 μg/L for I?,respectively.The method was successfully used to analyze IO3?,SOI and I? in environmental water samples,such as seawater,river water,rainwater and groundwater.

Result Analysis
Print
Save
E-mail