1.Changes of miR-223,miR-155 and miR-125 levels in neonates with sepsis and distribution of pathogens
Qirui FAN ; Meijing YIN ; Baofang ZHANG ; Lei DING ; Hongbo WU
Chinese Journal of Nosocomiology 2025;35(17):2646-2650
OBJECTIVE To explore the changes of microribonucleic acid(miR)-223,miR-155 and miR-125 in the neonates with sepsis and analyze the distribution of pathogens so as to provide bases for clinical diagnosis and treatment of neonates with sepsis.METHODS A total of 39 neonates with sepsis who were treated in Jinan Second Maternal and Child Health Hospital from May 2021 to May 2023 were enrolled in the study and were assigned as the study group,meanwhile,42 healthy neonates who were born in the hospital were chosen as the control group.The distribution and drug resistance of the pathogens isolated from the neonates of the study group were statistically analyzed.The relative expression levels of peripheral blood miR-223,miR-155 and miR-125 were com-pared between the two groups,and the values of the three indexes in diagnosis of neonatal sepsis were analyzed.RESULTS Totally 46 strains of pathogens were isolated from the 39 neonates with sepsis,20 of which were Escherichia coli,and 10 were Staphylococcus aureus.The E.coli strains were resistant to ampicillin,tetra-cycline,ciprofloxacin and cefazolin;the S.aureus strains were resistant to penicillin,erythromycin,cefazolin and clindamycin,with the drug resistance rates higher than 50%.The expression level of miR-223 of the study group was 2.13±0.70,higher than that of the control group,the expression level of miR-125 of the study group was 0.92±0.30,higher than that of the control group;while the expression level of miR-155 of the study group was 2.08±0.68,lower than that of the control group(P<0.05).The area under the curve(AUC)of the joint detec-tion of miR-223,miR-155 and miR-125 was 0.945 in diagnosis of neonatal sepsis,with the sensitivity 92.31%,the specificity 88.10%.CONCLUSIONS E.coli and S.aureus are dominant among the pathogens isolated from the neonates with sepsis.The neonates with sepsis show abnormal expressions of peripheral blood miR-223,miR-155 and miR-125,and the joint detection of the three indexes has high value in diagnosis of neonatal sepsis.
2.Changes of miR-223,miR-155 and miR-125 levels in neonates with sepsis and distribution of pathogens
Qirui FAN ; Meijing YIN ; Baofang ZHANG ; Lei DING ; Hongbo WU
Chinese Journal of Nosocomiology 2025;35(17):2646-2650
OBJECTIVE To explore the changes of microribonucleic acid(miR)-223,miR-155 and miR-125 in the neonates with sepsis and analyze the distribution of pathogens so as to provide bases for clinical diagnosis and treatment of neonates with sepsis.METHODS A total of 39 neonates with sepsis who were treated in Jinan Second Maternal and Child Health Hospital from May 2021 to May 2023 were enrolled in the study and were assigned as the study group,meanwhile,42 healthy neonates who were born in the hospital were chosen as the control group.The distribution and drug resistance of the pathogens isolated from the neonates of the study group were statistically analyzed.The relative expression levels of peripheral blood miR-223,miR-155 and miR-125 were com-pared between the two groups,and the values of the three indexes in diagnosis of neonatal sepsis were analyzed.RESULTS Totally 46 strains of pathogens were isolated from the 39 neonates with sepsis,20 of which were Escherichia coli,and 10 were Staphylococcus aureus.The E.coli strains were resistant to ampicillin,tetra-cycline,ciprofloxacin and cefazolin;the S.aureus strains were resistant to penicillin,erythromycin,cefazolin and clindamycin,with the drug resistance rates higher than 50%.The expression level of miR-223 of the study group was 2.13±0.70,higher than that of the control group,the expression level of miR-125 of the study group was 0.92±0.30,higher than that of the control group;while the expression level of miR-155 of the study group was 2.08±0.68,lower than that of the control group(P<0.05).The area under the curve(AUC)of the joint detec-tion of miR-223,miR-155 and miR-125 was 0.945 in diagnosis of neonatal sepsis,with the sensitivity 92.31%,the specificity 88.10%.CONCLUSIONS E.coli and S.aureus are dominant among the pathogens isolated from the neonates with sepsis.The neonates with sepsis show abnormal expressions of peripheral blood miR-223,miR-155 and miR-125,and the joint detection of the three indexes has high value in diagnosis of neonatal sepsis.
3.Endoscopic ultrasonography and CT in the preoperative diagnosis of pancreatic and periampullary neoplasms
Yin LI ; Yihua HUAHG ; Meijing HUANG
Chinese Journal of General Surgery 2000;0(12):-
0. 05 ). For detection of pancreatic duct dilation and lymph node metastasis, EUS was better than CT ( P=0.039,P=0.004). The accuracy of EUS in determing peripancreatic fat infiltration and organic invasion was correlated with tumor size (P=0.015,P=0.022) , pancreatic duct dilation was correlated with the location of tumors ( P

Result Analysis
Print
Save
E-mail