1.Acceptance and commissioning testing of multiparametric imaging using the big bore dual-source CT simulator for radiotherapy
Meijiao WANG ; Yi DU ; Kaining YAO ; Zhongsu FENG ; Jixiang CHEN ; Hao WU ; Kaixuan LI ; Haizhen YUE
Chinese Journal of Radiological Health 2025;34(5):764-769
Objective To evaluate the accuracy of multiparametric imaging on the dual-source CT through acceptance and commissioning testing, and to provide a reference for standardized clinical application. Methods Both the adult and pediatric dual-source CT scanning modes were used to scan the electron density phantom, and identical multiparametric image reconstruction tasks were performed, including the conventional CT images, the mixed CT images, the virtual monoenergetic images, the iodine images, the electron density images, and the effective atomic number images. Results In the adult scanning mode, the virtual monoenergetic CT numbers showed the greatest difference for the cortical bone (
2.Observation of the clinical efficacy of external application of piyan formula in treating EGFR-TKIs-related rash
Lei FU ; Hui ZHANG ; Tiandong LIN ; Jingwen JIANG ; Meijiao LI ; Peng WANG ; Lang CHEN ; Jianqiu HUANG ; Shaofei LIN
China Modern Doctor 2024;62(23):81-86
Objective To observe the clinical efficacy and safety of external application of Piyan Formula in treating epidermal growth factor receptor tyrosine kinase inhibitor(EGFR-TKIs)-related rashes.Methods Sixty cases of EGFR-TKIs-related rash patients were randomly allocated into either a treatment group or a control group.The treatment group received external application of Piyan Formula to the rash area twice daily for 14 days.The control group received external application of fucidic acid cream to the rash area twice daily for 14 days.Changes in rash grading,itching grading,quality of life scores and adverse event were observed and recorded in both groups.At the same time,levels of hypersensitive C-reactive protein,interleukin(IL)-6,and IL-1β were measured before treatment and 24 hours after treatment.Results After treatment,the rash severity,itching severity,and quality of life scores were notably lower in the treatment group compared to the control group(P<0.05).The levels of hypersensitive C-reactive protein,IL-6,and IL-1β exhibited a significant decrease compared to their pre-treatment values.(P<0.05).Compared with the control group,the levels of hypersensitive C-reactive protein,IL-6,and IL-1β decreased in the treatment group,with statistically significant differences(P<0.05).No adverse events related to Piyan Formula or fucidic acid cream occurred during the treatment process.Conclusion External application of Piyan Formula in treating EGFR-TKIs-related rashes shows significant clinical efficacy,can effectively reduce the levels of inflammatory factors,and has high safety,thus warranting clinical promotion.
3.Influence of airway mucus plugs on patients with bronchial asthma and its management
Kexin LIU ; Yingying GE ; Ying SHANG ; Meijiao LI ; Lina SUN ; Zhu SONG ; Chun CHANG
Chinese Journal of Health Management 2023;17(1):29-35
Objective:To explore the influence of airway mucus plugs on patients with bronchial asthma and its management.Methods:In this cross-sectional study, from January 2020 to June 2022, 100 patients who were diagnosed with asthma and underwent chest CT examination in the Outpatient Department of Peking University Third Hospital were included. The chest CT results and medical history, pulmonary function, fractional exhaled nitric oxide (FeNO), blood routine, total allergen IgE, Aspergillus fumigatus M3 allergen-specific IgE antibody test results were collected. According to the results of chest CT, the asthma patients were divided into group with mucus plugs and those without mucus plugs. Distribution of airway mucus plugs and the mucus plug scores based on lung segments were calculated. The relationships of mucus plugs with medical history, pulmonary function [These included before and after the bronchodilation test, forced vital capacity percent of predicted value (FVC%pred), forced expiratory volume in one second percent of predicted value (FEV 1%pred), FEV 1/FVC, peak expiratory flow percent of predicted value (PEF%pred), maximal mid-expiratory flow percent of predicted value (MMEF%pred), maximal expiratory flow at 25%, 50%, 75% of vital capacity remaining percent of predicted value (MEF 25%pred, MEF 50%pred, MEF 75%pred)], FeNO, and peripheral blood eosinophil (Eos) counts were analyzed. The logistic regression model was used to analyze whether airway mucus plug was a risk factor for asthma exacerbation, and the corresponding intervention strategies were explored. Results:Among the 100 patients with asthma, 24 cases were in the mucus plug group and 76 cases were in the non-mucus plug group. The distribution of mucus plug was more common in the lower lungs (30.53% and 9.16% in the lower and upper lobe of left lung, respectively; 29.01%, 14.50% and 16.80% in the lower, middle and upper lobe of right lung, respectively). The average score of mucus plug was (4.42±3.12) points. The body mass index (BMI), the number of visits to a doctor due to asthma exacerbations, FeNO, peripheral blood Eos counts in the mucus plug group were higher than those in the non-mucus plug group [(24.95±4.34) vs (23.22±2.91) kg/m 2, 0(0, 1) vs 0(0, 0), 97(37, 169) vs 31(18, 59) ppb (1 ppb=1×10 -9), 0.41(0.15, 0.70) vs 0.18(0.09, 0.37)×10 9/L](all P<0.05), and FVC%pred, FEV 1%pred, FEV 1/FVC, PEF%pred, MEF 50%pred, MEF 25%pred, MMEF%pred, MEF 75%pred were lower than those in the non-mucus plug group [(87.49±19.32)% vs (97.34±14.24)%, (76.49±19.58)% vs (91.07±18.33)%, (72.44±10.91)% vs (79.48±8.13)%, (82.36±24.46)% vs (93.83±18.27)%, (53.03±24.81)% vs (75.75±27.15)%, (46.47±22.92)% vs (64.09±25.90)%, (50.28±23.73)% vs (74.53±26.80)%, (71.30±27.55)% vs (89.92±26.82)%] (all P<0.05). In the group with mucus plug, the airway mucus plug score was positively correlated with the patient′s body weight and the number of peripheral blood Eos counts at enrollment ( r=0.413, 0.478; all P<0.05), and negatively correlated with FVC%pred and FEV 1%pred ( r=-0.576, -0.465; all P<0.05). Logistic regression analysis showed that airway mucus plug score was a risk factor for acute asthma attack ( OR=1.269, 95% CI: 1.031-1.562; P=0.024). Conclusions:Asthma patients have a high incidence of airway mucus plug, which is related to the level of Eos inflammation and body size. Airway mucus plugs can promote airflow obstruction and acute exacerbation of asthma. In clinical practice, appropriate asthma management policies can be formulated for airway mucus plugs to delay the progression of asthma and reduce the number of acute attacks.
4.Clinical features and genetic analysis of two fetuses with ring chromosome 21 mosaicism.
Yizhen JI ; Yasong XU ; Li SUN ; Yunsheng GE ; Meijiao CAI ; Qichang WU
Chinese Journal of Medical Genetics 2023;40(8):1032-1035
OBJECTIVE:
To investigate the perinatal clinical phenotype and genetic characteristics of two fetuses with ring chromosome 21 mosaicisms.
METHODS:
Two fetuses who were diagnosed at the Xiamen Maternal and Child Health Care Hospital in November 2021 were selected as the study subjects. Clinical data of the two fetuses were collected. Conventional G-banded karyotyping and chromosomal microarray analysis (CMA) were carried out for the fetuses and their parents.
RESULTS:
Prenatal ultrasonography of fetus 1 has revealed absence of nasal bone, ventricular septal defect, persistent left superior vena cava, and mild tricuspid regurgitation. Chromosomal karyotyping was 46,X?,dic r(21;21)(p12q22;q22p12)[41]/45,X?,-21[9]. CMA has revealed a 30.00 Mb quadruplication at 21q11.2q22.3 and a 3.00 Mb deletion at 21q22.3. For fetus 2, ultrasonography has revealed pointed echo of the nasal bone. The fetus was found to have a karyotype of 46,X?,r(21)(p12q22)[83]/45,X?,-21[14]/46,X?,dic r(21;21)(p12q22;q22p12)[3]. CMA has revealed a 5.10 Mb quadruplication at 21q22.12q22.3 and a 2.30 Mb deletion at 21q22.3.
CONCLUSION
The perinatal phenotype of the two fetuses with ring chromosome 21 mosaicisms is related to the duplication of chromosomal segments near the breakpoints of the chromosomal deletions. The combined chromosomal karyotyping and CMA has enabled prenatal diagnosis and genetic counseling for these families.
Pregnancy
;
Female
;
Humans
;
Mosaicism
;
Ring Chromosomes
;
Vena Cava, Superior
;
Chromosome Aberrations
;
Prenatal Diagnosis
;
Microarray Analysis
;
Fetus/diagnostic imaging*
5.A pair of transporters controls mitochondrial Zn2+ levels to maintain mitochondrial homeostasis.
Tengfei MA ; Liyuan ZHAO ; Jie ZHANG ; Ruofeng TANG ; Xin WANG ; Nan LIU ; Qian ZHANG ; Fengyang WANG ; Meijiao LI ; Qian SHAN ; Yang YANG ; Qiuyuan YIN ; Limei YANG ; Qiwen GAN ; Chonglin YANG
Protein & Cell 2022;13(3):180-202
Zn2+ is required for the activity of many mitochondrial proteins, which regulate mitochondrial dynamics, apoptosis and mitophagy. However, it is not understood how the proper mitochondrial Zn2+ level is achieved to maintain mitochondrial homeostasis. Using Caenorhabditis elegans, we reveal here that a pair of mitochondrion-localized transporters controls the mitochondrial level of Zn2+. We demonstrate that SLC-30A9/ZnT9 is a mitochondrial Zn2+ exporter. Loss of SLC-30A9 leads to mitochondrial Zn2+ accumulation, which damages mitochondria, impairs animal development and shortens the life span. We further identify SLC-25A25/SCaMC-2 as an important regulator of mitochondrial Zn2+ import. Loss of SLC-25A25 suppresses the abnormal mitochondrial Zn2+ accumulation and defective mitochondrial structure and functions caused by loss of SLC-30A9. Moreover, we reveal that the endoplasmic reticulum contains the Zn2+ pool from which mitochondrial Zn2+ is imported. These findings establish the molecular basis for controlling the correct mitochondrial Zn2+ levels for normal mitochondrial structure and functions.
Animals
;
Caenorhabditis elegans/metabolism*
;
Cation Transport Proteins/genetics*
;
Homeostasis
;
Mitochondria/metabolism*
;
Zinc/metabolism*
6.Workflow and error analyses of patient setup based on open-face mask immobilization combined with AlignRT for head tumor radiotherapy
Junyu LI ; Hao WU ; Jingxian YANG ; Shun ZHOU ; Zihong LU ; Songmao YU ; Jixiang CHEN ; Meijiao WANG ; Kaining YAO ; Yi DU
Chinese Journal of Radiological Medicine and Protection 2022;42(8):590-597
Objective:To propose a markless patient setup workflow based on the optical surface monitoring system (AlignRT) and open-face mask immobilization for whole-course head tumor radiotherapy, assess the setup time and repositioning frequency of the proposed workflow, and conduct a comparative analysis of the differences, correlation, and consistency of the setup errors of the AlignRT and cone beam CT (CBCT) systems.Methods:A retrospective analysis was conducted for the data on the errors of 132 fractionated setup based on open-face mask immobilization of 33 head tumor patients. AlignRT-guided markless patient setup workflow was applied throughout the radiotherapy. Meanwhile, the body structures automatically generated by the treatment planning system were used as body references. The 6-degree-of-freedom (6DoF) setup errors (lateral, vertical, longitudinal, rotation, pitch, roll, and yaw directions), setup time, and repositioning frequency of the AlignRT and CBCT systems were recorded and analyzed. The Wilcoxon and Spearman analyses were used to statistically assess the differences and correlation of the setup errors of the two systems. Moreover, the Bland-Altman analysis was employed to evaluate the consistency of the two systems.Results:The 6DoF setup errors of CBCT were within the clinical tolerance (linear motions: -0.30 to 0.30 cm; rotational motions: -2.0° to 2.0°). The setup time and repositioning frequency of CBCT were (98 ± 31) s and 1.51% (2/132), respectively. There was no significant difference in setup errors between the two systems except those in x-axis ( Z = -3.11, P= 0.002), y-axis ( Z = -7.40, P<0.001), and Pitch ( Z= -4.48, P<0.001). There was a significant positive correlation between the setup errors along lateral ( rs = 0.47, P<0.001) and vertical ( rs = 0.29, P = 0.001) directions, rotation (Rtn; rs = 0.47, P<0.001), pitch (Pitch; rs = 0.28, P = 0.001) and roll (Roll; rs = 0.45, P<0.001) of the two systems. The 95% limits of agreement (95% LoA) of 6DoF setup errors were -0.12 to 0.09 cm, -0.07 to 0.17 cm, -0.19 to 0.20 cm, -1.0° to 0.9 °, -1.0° to 1.5°, and -0.9° to 1.0°, respectively. The 95% confidence interval (95% CI) of 95% LoA was -0.14 to 0.11 cm, -0.09 to 0.19 cm, -0.23 to 0.23 cm, -1.2° to 1.1°, -1.2° to 1.7°, and-1.0° to 1.1°, respectively, all of which were within the permissible error ranges. The 6DoF setup error difference of 3.41% (27/792< 5%) was beyond the 95% LoA. The maximum absolute differences of 6DoF setup errors within the 95% LoA were 0.12, 0.16, 0.19 cm, 0.9°, 1.5°, and 1.0°, respectively. Conclusions:The proposed markless setup workflow based on AlignRT combined with open-face mask immobilization for whole-course head tumor radiotherapy exhibits reasonable agreement and consistency with the patient setup using CBCT, with acceptable clinical efficiency. It can be applied to the first radiotherapy and the real-time monitoring of therapy to improve the safety and thus is of value in clinical applications.
7.Application of CRISPR/Cas-based biosensors for detecting nucleic acid of pathogens.
Tao LIU ; Yachen TIAN ; Cheng LIU ; Shuiqin FANG ; Youxue WU ; Meijiao WU ; Bin LI ; Hao YANG ; Qing LIU
Chinese Journal of Biotechnology 2021;37(11):3890-3904
Clustered regularly interspaced short palindromic repeats/clustered regularly interspaced short palindromic repeats -associated protein (CRISPR/Cas) has been developed as a precise, efficient, affordable and sensitive nucleic acid detection tool due to its efficient targeted binding ability and programmability. At present, biosensors based on CRISPR-Cas system have shown excellent performance in the detection of nucleic acid of pathogens, which has attracted widespread attention, and is expected to replace the conventional detection methods. This review summarizes the latest research progress of biosensors based on CRISPR/Cas system for detecting nucleic acid of pathogens.
Biosensing Techniques
;
CRISPR-Cas Systems/genetics*
;
Nucleic Acids/genetics*
8.A case report of kerosene-induced chemical pneumonia with pleural effusion and abnormal pulmonary function
Bangtao LI ; Hongai LI ; Yuanping HAI ; Qi WANG ; Meijiao HUANG ; Wei XIANG
Chinese Journal of Applied Clinical Pediatrics 2021;36(8):628-630
The clinical data of a child with chemical pneumonia caused by kerosene in Hainan Maternal and Children′s Medical Center in June 2019 were retrospectively analyzed.The patient was a 2 years and 1 month old boy with a history of kerosene inhalation and fever.The clinical features included low breath sounds in the left lung and dry and wet rales in both lungs.The white blood cells (WBC) level, C-reactive protein (CRP) level, and erythrocyte se-dimentation rate (ESR) were significantly increased.Chest CT showed inhalation pneumonia.Chest ultrasound suggested medium pleural effusion on the left side.The patient was given antibiotics, nebulization and other treatment.On the 12 th day of the course of the disease, his temperature returned to normal, and breath sounds on the left side were stronger than before.The WBC level, CRP level and ESR were improved according to the re-check results, but pulmonary ventilation was still obstructed mildly to moderately.Fourteen days after hospital discharge, the patient coughed less.Reexamination of chest CT prompted the lesions were further absorbed, but the mild to moderate obstructive lesions were still observed.With the reduction of kerosene use in daily life, kerosene-induced chemical pneumonia is rare, but due to its diverse and complex clinical manifestations and slow absorption of pulmonary inflammation, attention should be paid to its progression into chronic cough.
9.Exploring the investigation level for individual monitoring for medical radiation workers in Guangdong province
Weizhen GUO ; Xiaolian LIU ; Meijiao QIU ; Mingfang LI ; Sufen ZHANG ; Weiji MAI ; Yuxin JIA
Chinese Journal of Radiological Medicine and Protection 2021;41(2):128-133
Objective:To explore the investigation level of individual monitoring for medical radiation workers.Methods:Monitoring and analysis of individual doses to the medical radiation workers in Guangdong province were performed, from 2016 to 2019, by the Individual Dose Monitoring Department of Guangdong Provincial Hospital for Occupational Disease Prevention and Control.Results:The numbers of monitored workers were diagnostic radiology 53 674, dental radiology 2 563, nuclear medicine 5 001, radiotherapy 16 687, interventional radiology 22 272 and others 2 087 from 2016 to 2019, of which the number of individuals with doses in excess of investigation level 1.25 mSv, were 76, 6, 18, 28, 133 and 2 respectively. The non-real doses made up 67.1 %, 100 %, 55.6 %, 82.1 %, 76.7 % and 100 % of their respective totals. Their 99th percentile doses P99 were 0.37, 0.39, 0.67, 0.35, 0.54 and 0.30 mSv, and the average periodic dose equivalent were 0.07, 0.06, 0.11, 0.06, 0.07 and 0.05 mSv respectively, indicating a statistically significant difference existing in the average annual effective dose between groups ( Z=-26.139--2.681, P<0.001). Conclusions:Due to non-reality of doses in excess of investigation levels and high labor cost, it is suggested to currently use 0.40 mSv per 3 months as investigation level for diagnostic radiology, dental radiology, radiotherapy and others, and 0.70 mSv per 3 months as for nuclear medicine and interventional radiology.
10.The performance of plastic scintillator detector in photon and electron beam
Meijiao WANG ; Kaining YAO ; Sha LI ; Haizhen YUE ; Zhuolun LIU ; Fan JIANG ; Hao WU ; Ruoxi WANG
Chinese Journal of Radiological Medicine and Protection 2021;41(3):205-211
Objective:To investigate the performance of W2 plastic scintillator in megavolt photon and electron beams.Methods:The photon and electron beam energy provided by linear accelerator was used to collect data of the W2 scintillator. The parameters include the electrometer reading stability, W2 dose and dose rate linearity, and angular response. And the dose uncertainty of the W2 correction factors was also investigated.Results:The standard deviation of the electrometer reading stability was between 0.03 and 0.47. The linear regression factors of W2 dose were all 1.0; the maximum deviation of the dose rates was 0.61%. The Cerenkov light radiation correction factor(CLR) for 6 and 10 MV were 0.741 and 0.746, respectively, and the CLR for 6, 9, 12 and 15 MeV were 0.750, 0.753, 0.757 and 0.757, respectively. The maximum deviation of dose uncertainty for 15 MeV was 3.15%.Conclusions:The signal obtained by the blue and green channel was no angular dependence, the same as the high-energy electron beam, which verified that the Cerenkov radiation correction factor has good linearity. W2 plastic scintillator can be applied to non-coplanar radiotherapy dosimetry.

Result Analysis
Print
Save