1.Impact of bundle intervention measures on incidence of catheter-related infections in ICU patients of neurosurgery department
Ya YANG ; Mei HAUNG ; Jiayan DING ; Xiaofang FU ; Yu ZHENG ; Haiqun BAN
Chinese Journal of Nosocomiology 2025;35(6):945-949
OBJECTIVE To evaluate the impact of bundle intervention measures on incidence of catheter-related in-fections in patients of neurosurgery intensive care unit(NICU).METHODS The related data regarding to incidence rates of hospital-associated infections and utilization rates of catheters were collected from the NICU patients of Renji Hospital,Shanghai Jiaotong University from 2007 to 2022.The effect of the bundle intervention measures on reducing the incidence of catheter-related infections was analyzed by means of interrupted tune series(ITS)method.RESULTS There was significant difference in the decline trend of incidence of the infections during the study(the trend x2=91.978,P<0.001).ITS analysis showed that the utilization rate of catheters only presented the decline trend after the intervention(β2=-0.667,P=0.042),the utilization rate of ventilator tubes only de-clined after the intervention(β3=-26.375,P<0.001).Th utilization rate of central venous catheters showed a downward trend before the intervention(β1=-2.525,P<0.001)but did not change significantly after the inter-vention.The incidence of central line-associated bloodstream infection(CLABSI)was decreased(RR=0.268,95%CI:0.124 to 0.581),however,there was significant difference in the change of slope(RR=0.912,95%CI:0.730 to 1.140).The incidence of catheter-associated urinary tract infection(CAUTI)showed a downward trend(RR=0.796,95%CI:0.647 to 0.975),however,there was no significant difference in the change of the level(RR=1.543,95%CI:0.816 to 3.005).The incidence of ventilator-associated pneumonia(VAP)showed a downward trend(RR=0.829,95%CI:0.767 to 0.895),however,there was no significant difference in the change of the level(RR=0.817,95%CI:0.595 to 1.114).CONCLUSIONS The bundle intervention measures may effectively reduce the incidence of catheter-related infections.The incidence rates of the catheter-related infections vary in the chan-ging trends after the interventions are taken,indicating that it is necessary to comprehensively take the character-istics of catheter-related infections into account when carrying out the bundle intervention measures and continu-ously optimize the control strategies.
2.Impact of bundle intervention measures on incidence of catheter-related infections in ICU patients of neurosurgery department
Ya YANG ; Mei HAUNG ; Jiayan DING ; Xiaofang FU ; Yu ZHENG ; Haiqun BAN
Chinese Journal of Nosocomiology 2025;35(6):945-949
OBJECTIVE To evaluate the impact of bundle intervention measures on incidence of catheter-related in-fections in patients of neurosurgery intensive care unit(NICU).METHODS The related data regarding to incidence rates of hospital-associated infections and utilization rates of catheters were collected from the NICU patients of Renji Hospital,Shanghai Jiaotong University from 2007 to 2022.The effect of the bundle intervention measures on reducing the incidence of catheter-related infections was analyzed by means of interrupted tune series(ITS)method.RESULTS There was significant difference in the decline trend of incidence of the infections during the study(the trend x2=91.978,P<0.001).ITS analysis showed that the utilization rate of catheters only presented the decline trend after the intervention(β2=-0.667,P=0.042),the utilization rate of ventilator tubes only de-clined after the intervention(β3=-26.375,P<0.001).Th utilization rate of central venous catheters showed a downward trend before the intervention(β1=-2.525,P<0.001)but did not change significantly after the inter-vention.The incidence of central line-associated bloodstream infection(CLABSI)was decreased(RR=0.268,95%CI:0.124 to 0.581),however,there was significant difference in the change of slope(RR=0.912,95%CI:0.730 to 1.140).The incidence of catheter-associated urinary tract infection(CAUTI)showed a downward trend(RR=0.796,95%CI:0.647 to 0.975),however,there was no significant difference in the change of the level(RR=1.543,95%CI:0.816 to 3.005).The incidence of ventilator-associated pneumonia(VAP)showed a downward trend(RR=0.829,95%CI:0.767 to 0.895),however,there was no significant difference in the change of the level(RR=0.817,95%CI:0.595 to 1.114).CONCLUSIONS The bundle intervention measures may effectively reduce the incidence of catheter-related infections.The incidence rates of the catheter-related infections vary in the chan-ging trends after the interventions are taken,indicating that it is necessary to comprehensively take the character-istics of catheter-related infections into account when carrying out the bundle intervention measures and continu-ously optimize the control strategies.
3.Observation on the change of electrode impedance and THR/MCL values in 20 cases with Med-EL Combi 40+ cochlear implant.
Wenjin WU ; Huan JIA ; Yun LI ; Zhijian TANG ; Qi HUANG ; Jun YANG ; Ling MEI ; Zhiwu HAUNG ; Hao WU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2013;27(22):1238-1242
OBJECTIVE:
To investigate the changes of electrode impedance, THR/MCL values, and dynamic range (DR) in Combi 40+ cochlear implant after implantation.
METHOD:
A respective study was carried out collecting 20 consecutively implanted children's electrode impedances, THR/MCL values, and DR at seven time point during the first three years after implantation. Their variation and correlations were analyzed.
RESULT:
Overall, electrode impedances were lowest during the operation, and significantly rise to the highest at the first stimulation, then followed by a gradual decrease. After three months, electrode impedance of apical and medial cochlear segment were basically stable, while that of the basal segment was gradually increased. Dynamic range (DR) of apical and medial group electrode increased early after the operation and showed a stabilization from the second year, whereas that of basal group have a downward trend since the first year. However, the electric charge of each group increased significantly after three months, and then become stable after first year. Otherwise, a stronger negative rectilinear correlation was found between impedance changes with DR than with THR/MCL level.
CONCLUSION
The electrode impedances vary clue to different electrode position. Measuring the electrode impedance can effectively evaluate the working status of Combi C40+ cochlear implant. The dynamic range of the electrode was negatively correlated with the impedances, which made it possible to predict the width of the dynamic range by measuring the impedance 3 or 6 months after operation.
Auditory Threshold
;
Child
;
Child, Preschool
;
Cochlear Implantation
;
Cochlear Implants
;
Electric Impedance
;
Electrodes
;
Female
;
Hearing Loss
;
physiopathology
;
rehabilitation
;
Humans
;
Male

Result Analysis
Print
Save
E-mail