1.Eyeball Donation and Management System
Jaeyoung KIM ; Chul Young CHOI ; Jae Yong KIM ; Roo Min JUN ; Eun Chul KIM ; Yong-Soo BYUN ; Jong Hwa JUN ; Dong Hyun KIM ; Yunjin LEE ; Hyung Keun LEE ; Mee Kum KIM
Journal of the Korean Ophthalmological Society 2026;67(2):33-46
Purpose:
To propose improvements for promoting eyeball donation and managing donated corneas, this study analyzed the current system in Korea and reviewed relevant Korean laws, international standards, and foreign practices.
Methods:
To understand the current situation in Korea, annual reports published by the Korean Network for Organ Sharing and existing Korean laws were examined. For the international context, references were made to the National Organ Transplant Act, 21 CFR Part 1271 (Code of Federal Regulations Title 21 Part 1271), Current Good Tissue Practice guidelines of the Food and Drug Administration, and the Medical Standards of the Eye Bank Association of America in the United States. Opinions on promoting eyeball donation, improving the monitoring system for donated corneas and revising laws related to cornea management were gathered. The perspectives of 31 experts affiliated with the Korea Cornea Society were collected through a survey.
Results:
Currently, there are no laws or regulations that can be appropriately applied to the cornea which has properties of both organs and tissue. Additionally, there is no law regulating imported corneas. Therefore, there is a need to legislate or revise the current law; all experts who conducted the survey agreed on this. Furthermore, the current system faces limitations in the efficient procurement, stable supply, and management of donor corneas, as well as in donation promotion. To address these issues, the establishment of independent legislation for managing donated corneas and a National Central Eye Bank was proposed. This central body would oversee continuous personnel training, education, and monitoring, along with ensuring stable procurement, processing, and supply of corneas within a structured management system. Sixty-eight percent of the surveyed experts agreed with this proposal.
Conclusions
To establish a safe and efficient Korean corneal supply and demand system, it is imperative to enact cornea-specific laws, including the establishment of a National Central Eye Bank.
2.Long-term Effects and Prognostic Factors of Accelerated Cross-Linking with Retention Ring-assisted Riboflavin Application on Keratoconus Progression
Seonghwan KIM ; Won Jong CHOI ; Chang Ho YOON ; Mee Kum KIM
Korean Journal of Ophthalmology 2025;39(2):145-156
Purpose:
To evaluate the long-term efficacy, safety, and prognostic factors of pulsed-light accelerated corneal collagen cross-linking (A-CXL) with continuous riboflavin application to halt keratoconus progression
Methods:
A-CXL with retention ring-assisted continuous riboflavin application for either 10 or 5 minutes was performed in 37 eyes of 33 patients with progressive keratoconus between 2016 and 2020. Successful halting rates and prognostic factors of time-dependent changes in keratometric values, visual acuity, refractive errors, topographic indices, central corneal thickness, thinnest corneal thickness, irregularity at 3- and 5-mm zone, and endothelial cell density were evaluated.
Results:
Survival analysis showed successful halting rates of 71% and 89% in A-CXL with 5- and 10-minute–applied riboflavin, respectively. Best-corrected visual acuity significantly improved after A-CXL in both groups. Maximum keratometry decreased significantly from 52.52 to 50.39 diopters (p < 0.001) in the 10-minute group, while there was no significant decrease in the 5-minute group (52.77–51.80 diopters, p = 0.146). irregularity in 3- and 5-mm zone decreased significantly in the 10-minute group, while there was no difference in 5-minute group. Central corneal thickness and thinnest corneal thickness did not differ, and endothelial cell density changes were within acceptable ranges in both groups before and after the surgery. Among keratometric values, keratometric astigmatism was significantly related to posttreatment corneal flattening effect in multivariate regression analysis.
Conclusions
A-CXL with continuous riboflavin application for 10 minutes is an effective and safe treatment for preventing keratoconus progression. In addition, higher corneal astigmatism showed greater posttreatment corneal flattening effect in successfully treated patients.
3.Long-term Outcome and Related Risk Factors in Implantable Collamer Lens Implantation of High Myopia
Yong Hee KIM ; Chang Ho YOON ; Mee Kum KIM
Korean Journal of Ophthalmology 2025;39(2):134-144
Purpose:
To investigate the long-term efficacy and safety of posterior chamber implantable collamer lens (ICL) implantation in high myopia, and the risk factors associated with endothelial cell loss (ECL) or cataract development.
Methods:
Medical records of 66 eyes of 37 patients who underwent ICL implantation for high myopia were retrospectively analyzed with a mean follow-up of 12 years. Changes in best-corrected visual acuity (logarithm of the minimum angle of resolution), intraocular pressure (IOP), refractive power, and endothelial cell density over time were analyzed with the incidence of cataract and IOP elevation. Risk factors were analyzed for their association with ECL or cataract development.
Results:
At 10 years after surgery, the mean uncorrected visual acuity was 0.06 and the spherical equivalent was –0.90 diopters. By year 10, cataract was present in 13 of 66 eyes (19.7%), whereas glaucoma was found in 1 of 66 eyes (1.5%). Although IOP continuously elevated over time (p < 0.05), it remained within normal limits. The cataract group had a lower vault of ICL and a higher mean age at surgery (p < 0.05). Endothelial cell density remained above 2,000/mm2 in 98.5% of cases, with an average annualized rate of decline of 1.13%. The high annualized rate group (>1.13% loss per year) had a lower mean age than in the low annualized rate group (<1.13% loss per year, p < 0.05).
Conclusions
This indicates that ICL implantation is effective for high myopia, and its main complication is cataract and ECL. It also suggests that ECL and cataract should be regularly monitored although ECL looks stable in long-term follow-up. Age may affect both ECL and cataract, while low-vault ICL may affect cataract.
4.Long-term Effects and Prognostic Factors of Accelerated Cross-Linking with Retention Ring-assisted Riboflavin Application on Keratoconus Progression
Seonghwan KIM ; Won Jong CHOI ; Chang Ho YOON ; Mee Kum KIM
Korean Journal of Ophthalmology 2025;39(2):145-156
Purpose:
To evaluate the long-term efficacy, safety, and prognostic factors of pulsed-light accelerated corneal collagen cross-linking (A-CXL) with continuous riboflavin application to halt keratoconus progression
Methods:
A-CXL with retention ring-assisted continuous riboflavin application for either 10 or 5 minutes was performed in 37 eyes of 33 patients with progressive keratoconus between 2016 and 2020. Successful halting rates and prognostic factors of time-dependent changes in keratometric values, visual acuity, refractive errors, topographic indices, central corneal thickness, thinnest corneal thickness, irregularity at 3- and 5-mm zone, and endothelial cell density were evaluated.
Results:
Survival analysis showed successful halting rates of 71% and 89% in A-CXL with 5- and 10-minute–applied riboflavin, respectively. Best-corrected visual acuity significantly improved after A-CXL in both groups. Maximum keratometry decreased significantly from 52.52 to 50.39 diopters (p < 0.001) in the 10-minute group, while there was no significant decrease in the 5-minute group (52.77–51.80 diopters, p = 0.146). irregularity in 3- and 5-mm zone decreased significantly in the 10-minute group, while there was no difference in 5-minute group. Central corneal thickness and thinnest corneal thickness did not differ, and endothelial cell density changes were within acceptable ranges in both groups before and after the surgery. Among keratometric values, keratometric astigmatism was significantly related to posttreatment corneal flattening effect in multivariate regression analysis.
Conclusions
A-CXL with continuous riboflavin application for 10 minutes is an effective and safe treatment for preventing keratoconus progression. In addition, higher corneal astigmatism showed greater posttreatment corneal flattening effect in successfully treated patients.
5.Long-term Outcome and Related Risk Factors in Implantable Collamer Lens Implantation of High Myopia
Yong Hee KIM ; Chang Ho YOON ; Mee Kum KIM
Korean Journal of Ophthalmology 2025;39(2):134-144
Purpose:
To investigate the long-term efficacy and safety of posterior chamber implantable collamer lens (ICL) implantation in high myopia, and the risk factors associated with endothelial cell loss (ECL) or cataract development.
Methods:
Medical records of 66 eyes of 37 patients who underwent ICL implantation for high myopia were retrospectively analyzed with a mean follow-up of 12 years. Changes in best-corrected visual acuity (logarithm of the minimum angle of resolution), intraocular pressure (IOP), refractive power, and endothelial cell density over time were analyzed with the incidence of cataract and IOP elevation. Risk factors were analyzed for their association with ECL or cataract development.
Results:
At 10 years after surgery, the mean uncorrected visual acuity was 0.06 and the spherical equivalent was –0.90 diopters. By year 10, cataract was present in 13 of 66 eyes (19.7%), whereas glaucoma was found in 1 of 66 eyes (1.5%). Although IOP continuously elevated over time (p < 0.05), it remained within normal limits. The cataract group had a lower vault of ICL and a higher mean age at surgery (p < 0.05). Endothelial cell density remained above 2,000/mm2 in 98.5% of cases, with an average annualized rate of decline of 1.13%. The high annualized rate group (>1.13% loss per year) had a lower mean age than in the low annualized rate group (<1.13% loss per year, p < 0.05).
Conclusions
This indicates that ICL implantation is effective for high myopia, and its main complication is cataract and ECL. It also suggests that ECL and cataract should be regularly monitored although ECL looks stable in long-term follow-up. Age may affect both ECL and cataract, while low-vault ICL may affect cataract.
6.Long-term Effects and Prognostic Factors of Accelerated Cross-Linking with Retention Ring-assisted Riboflavin Application on Keratoconus Progression
Seonghwan KIM ; Won Jong CHOI ; Chang Ho YOON ; Mee Kum KIM
Korean Journal of Ophthalmology 2025;39(2):145-156
Purpose:
To evaluate the long-term efficacy, safety, and prognostic factors of pulsed-light accelerated corneal collagen cross-linking (A-CXL) with continuous riboflavin application to halt keratoconus progression
Methods:
A-CXL with retention ring-assisted continuous riboflavin application for either 10 or 5 minutes was performed in 37 eyes of 33 patients with progressive keratoconus between 2016 and 2020. Successful halting rates and prognostic factors of time-dependent changes in keratometric values, visual acuity, refractive errors, topographic indices, central corneal thickness, thinnest corneal thickness, irregularity at 3- and 5-mm zone, and endothelial cell density were evaluated.
Results:
Survival analysis showed successful halting rates of 71% and 89% in A-CXL with 5- and 10-minute–applied riboflavin, respectively. Best-corrected visual acuity significantly improved after A-CXL in both groups. Maximum keratometry decreased significantly from 52.52 to 50.39 diopters (p < 0.001) in the 10-minute group, while there was no significant decrease in the 5-minute group (52.77–51.80 diopters, p = 0.146). irregularity in 3- and 5-mm zone decreased significantly in the 10-minute group, while there was no difference in 5-minute group. Central corneal thickness and thinnest corneal thickness did not differ, and endothelial cell density changes were within acceptable ranges in both groups before and after the surgery. Among keratometric values, keratometric astigmatism was significantly related to posttreatment corneal flattening effect in multivariate regression analysis.
Conclusions
A-CXL with continuous riboflavin application for 10 minutes is an effective and safe treatment for preventing keratoconus progression. In addition, higher corneal astigmatism showed greater posttreatment corneal flattening effect in successfully treated patients.
7.Long-term Outcome and Related Risk Factors in Implantable Collamer Lens Implantation of High Myopia
Yong Hee KIM ; Chang Ho YOON ; Mee Kum KIM
Korean Journal of Ophthalmology 2025;39(2):134-144
Purpose:
To investigate the long-term efficacy and safety of posterior chamber implantable collamer lens (ICL) implantation in high myopia, and the risk factors associated with endothelial cell loss (ECL) or cataract development.
Methods:
Medical records of 66 eyes of 37 patients who underwent ICL implantation for high myopia were retrospectively analyzed with a mean follow-up of 12 years. Changes in best-corrected visual acuity (logarithm of the minimum angle of resolution), intraocular pressure (IOP), refractive power, and endothelial cell density over time were analyzed with the incidence of cataract and IOP elevation. Risk factors were analyzed for their association with ECL or cataract development.
Results:
At 10 years after surgery, the mean uncorrected visual acuity was 0.06 and the spherical equivalent was –0.90 diopters. By year 10, cataract was present in 13 of 66 eyes (19.7%), whereas glaucoma was found in 1 of 66 eyes (1.5%). Although IOP continuously elevated over time (p < 0.05), it remained within normal limits. The cataract group had a lower vault of ICL and a higher mean age at surgery (p < 0.05). Endothelial cell density remained above 2,000/mm2 in 98.5% of cases, with an average annualized rate of decline of 1.13%. The high annualized rate group (>1.13% loss per year) had a lower mean age than in the low annualized rate group (<1.13% loss per year, p < 0.05).
Conclusions
This indicates that ICL implantation is effective for high myopia, and its main complication is cataract and ECL. It also suggests that ECL and cataract should be regularly monitored although ECL looks stable in long-term follow-up. Age may affect both ECL and cataract, while low-vault ICL may affect cataract.
8.Long-term Effects and Prognostic Factors of Accelerated Cross-Linking with Retention Ring-assisted Riboflavin Application on Keratoconus Progression
Seonghwan KIM ; Won Jong CHOI ; Chang Ho YOON ; Mee Kum KIM
Korean Journal of Ophthalmology 2025;39(2):145-156
Purpose:
To evaluate the long-term efficacy, safety, and prognostic factors of pulsed-light accelerated corneal collagen cross-linking (A-CXL) with continuous riboflavin application to halt keratoconus progression
Methods:
A-CXL with retention ring-assisted continuous riboflavin application for either 10 or 5 minutes was performed in 37 eyes of 33 patients with progressive keratoconus between 2016 and 2020. Successful halting rates and prognostic factors of time-dependent changes in keratometric values, visual acuity, refractive errors, topographic indices, central corneal thickness, thinnest corneal thickness, irregularity at 3- and 5-mm zone, and endothelial cell density were evaluated.
Results:
Survival analysis showed successful halting rates of 71% and 89% in A-CXL with 5- and 10-minute–applied riboflavin, respectively. Best-corrected visual acuity significantly improved after A-CXL in both groups. Maximum keratometry decreased significantly from 52.52 to 50.39 diopters (p < 0.001) in the 10-minute group, while there was no significant decrease in the 5-minute group (52.77–51.80 diopters, p = 0.146). irregularity in 3- and 5-mm zone decreased significantly in the 10-minute group, while there was no difference in 5-minute group. Central corneal thickness and thinnest corneal thickness did not differ, and endothelial cell density changes were within acceptable ranges in both groups before and after the surgery. Among keratometric values, keratometric astigmatism was significantly related to posttreatment corneal flattening effect in multivariate regression analysis.
Conclusions
A-CXL with continuous riboflavin application for 10 minutes is an effective and safe treatment for preventing keratoconus progression. In addition, higher corneal astigmatism showed greater posttreatment corneal flattening effect in successfully treated patients.
9.Long-term Outcome and Related Risk Factors in Implantable Collamer Lens Implantation of High Myopia
Yong Hee KIM ; Chang Ho YOON ; Mee Kum KIM
Korean Journal of Ophthalmology 2025;39(2):134-144
Purpose:
To investigate the long-term efficacy and safety of posterior chamber implantable collamer lens (ICL) implantation in high myopia, and the risk factors associated with endothelial cell loss (ECL) or cataract development.
Methods:
Medical records of 66 eyes of 37 patients who underwent ICL implantation for high myopia were retrospectively analyzed with a mean follow-up of 12 years. Changes in best-corrected visual acuity (logarithm of the minimum angle of resolution), intraocular pressure (IOP), refractive power, and endothelial cell density over time were analyzed with the incidence of cataract and IOP elevation. Risk factors were analyzed for their association with ECL or cataract development.
Results:
At 10 years after surgery, the mean uncorrected visual acuity was 0.06 and the spherical equivalent was –0.90 diopters. By year 10, cataract was present in 13 of 66 eyes (19.7%), whereas glaucoma was found in 1 of 66 eyes (1.5%). Although IOP continuously elevated over time (p < 0.05), it remained within normal limits. The cataract group had a lower vault of ICL and a higher mean age at surgery (p < 0.05). Endothelial cell density remained above 2,000/mm2 in 98.5% of cases, with an average annualized rate of decline of 1.13%. The high annualized rate group (>1.13% loss per year) had a lower mean age than in the low annualized rate group (<1.13% loss per year, p < 0.05).
Conclusions
This indicates that ICL implantation is effective for high myopia, and its main complication is cataract and ECL. It also suggests that ECL and cataract should be regularly monitored although ECL looks stable in long-term follow-up. Age may affect both ECL and cataract, while low-vault ICL may affect cataract.
10.Long-term Effects and Prognostic Factors of Accelerated Cross-Linking with Retention Ring-assisted Riboflavin Application on Keratoconus Progression
Seonghwan KIM ; Won Jong CHOI ; Chang Ho YOON ; Mee Kum KIM
Korean Journal of Ophthalmology 2025;39(2):145-156
Purpose:
To evaluate the long-term efficacy, safety, and prognostic factors of pulsed-light accelerated corneal collagen cross-linking (A-CXL) with continuous riboflavin application to halt keratoconus progression
Methods:
A-CXL with retention ring-assisted continuous riboflavin application for either 10 or 5 minutes was performed in 37 eyes of 33 patients with progressive keratoconus between 2016 and 2020. Successful halting rates and prognostic factors of time-dependent changes in keratometric values, visual acuity, refractive errors, topographic indices, central corneal thickness, thinnest corneal thickness, irregularity at 3- and 5-mm zone, and endothelial cell density were evaluated.
Results:
Survival analysis showed successful halting rates of 71% and 89% in A-CXL with 5- and 10-minute–applied riboflavin, respectively. Best-corrected visual acuity significantly improved after A-CXL in both groups. Maximum keratometry decreased significantly from 52.52 to 50.39 diopters (p < 0.001) in the 10-minute group, while there was no significant decrease in the 5-minute group (52.77–51.80 diopters, p = 0.146). irregularity in 3- and 5-mm zone decreased significantly in the 10-minute group, while there was no difference in 5-minute group. Central corneal thickness and thinnest corneal thickness did not differ, and endothelial cell density changes were within acceptable ranges in both groups before and after the surgery. Among keratometric values, keratometric astigmatism was significantly related to posttreatment corneal flattening effect in multivariate regression analysis.
Conclusions
A-CXL with continuous riboflavin application for 10 minutes is an effective and safe treatment for preventing keratoconus progression. In addition, higher corneal astigmatism showed greater posttreatment corneal flattening effect in successfully treated patients.

Result Analysis
Print
Save
E-mail