1.Successful pancreatic pseudocyst drainage using lumen-apposing metal stent for preventing re-rupture of splenic artery pseudoaneurysm
Takashi ITO ; Tsukasa IKEURA ; Koh NAKAMARU ; Masataka MASUDA ; Shinji NAKAYAMA ; Makoto NAGANUMA
International Journal of Gastrointestinal Intervention 2025;14(1):32-34
Splenic pseudoaneurysm rupture is a serious condition that sometimes leads to death. Pseudoaneurysm rupture is often treated with transcatheter arterial embolization (TAE), after which the re-rupture rate is 18%–37%. A 59-year-old man presented with back pain, and contrast-enhanced computed tomography (CECT) revealed pancreatic tail cancer with multiple liver metastases. After three courses of chemotherapy, CECT revealed good response with shrinkage of the tumors. However, the patient had back pain and CECT revealed pancreatic pseudocyst with pseudoaneurysm rupture. He underwent angiography, wherein the splenic artery pseudoaneurysm was embolized using TAE. Subsequently, pseudocyst drainage was performed using lumen-apposing metal stent (LAMS) to prevent pseudoaneurysm re-rupture. Thereafter, the pseudocyst shrieked with decreased serum levels of C-reactive protein, allowing the patient to re-institute chemotherapy. Pseudocyst drainage using LAMS was safe and effective when the pancreatic pseudoaneurysm had a high-risk rebleeding due to exposure to pancreatic juice.
2.Successful pancreatic pseudocyst drainage using lumen-apposing metal stent for preventing re-rupture of splenic artery pseudoaneurysm
Takashi ITO ; Tsukasa IKEURA ; Koh NAKAMARU ; Masataka MASUDA ; Shinji NAKAYAMA ; Makoto NAGANUMA
International Journal of Gastrointestinal Intervention 2025;14(1):32-34
Splenic pseudoaneurysm rupture is a serious condition that sometimes leads to death. Pseudoaneurysm rupture is often treated with transcatheter arterial embolization (TAE), after which the re-rupture rate is 18%–37%. A 59-year-old man presented with back pain, and contrast-enhanced computed tomography (CECT) revealed pancreatic tail cancer with multiple liver metastases. After three courses of chemotherapy, CECT revealed good response with shrinkage of the tumors. However, the patient had back pain and CECT revealed pancreatic pseudocyst with pseudoaneurysm rupture. He underwent angiography, wherein the splenic artery pseudoaneurysm was embolized using TAE. Subsequently, pseudocyst drainage was performed using lumen-apposing metal stent (LAMS) to prevent pseudoaneurysm re-rupture. Thereafter, the pseudocyst shrieked with decreased serum levels of C-reactive protein, allowing the patient to re-institute chemotherapy. Pseudocyst drainage using LAMS was safe and effective when the pancreatic pseudoaneurysm had a high-risk rebleeding due to exposure to pancreatic juice.
3.Successful pancreatic pseudocyst drainage using lumen-apposing metal stent for preventing re-rupture of splenic artery pseudoaneurysm
Takashi ITO ; Tsukasa IKEURA ; Koh NAKAMARU ; Masataka MASUDA ; Shinji NAKAYAMA ; Makoto NAGANUMA
International Journal of Gastrointestinal Intervention 2025;14(1):32-34
Splenic pseudoaneurysm rupture is a serious condition that sometimes leads to death. Pseudoaneurysm rupture is often treated with transcatheter arterial embolization (TAE), after which the re-rupture rate is 18%–37%. A 59-year-old man presented with back pain, and contrast-enhanced computed tomography (CECT) revealed pancreatic tail cancer with multiple liver metastases. After three courses of chemotherapy, CECT revealed good response with shrinkage of the tumors. However, the patient had back pain and CECT revealed pancreatic pseudocyst with pseudoaneurysm rupture. He underwent angiography, wherein the splenic artery pseudoaneurysm was embolized using TAE. Subsequently, pseudocyst drainage was performed using lumen-apposing metal stent (LAMS) to prevent pseudoaneurysm re-rupture. Thereafter, the pseudocyst shrieked with decreased serum levels of C-reactive protein, allowing the patient to re-institute chemotherapy. Pseudocyst drainage using LAMS was safe and effective when the pancreatic pseudoaneurysm had a high-risk rebleeding due to exposure to pancreatic juice.
4.Single exposure to near-threshold 5G millimeter wave modifies restraint stress responses in rats.
Akiko MATSUMOTO ; Ikumi ENDO ; Etsuko IJIMA ; Akimasa HIRATA ; Sachiko KODERA ; Masayoshi ICHIBA ; Mikiko TOKIYA ; Takashi HIKAGE ; Hiroshi MASUDA
Environmental Health and Preventive Medicine 2025;30():33-33
BACKGROUND:
In response to growing concerns about the health effects of quasi-millimeter waves (qMMW) used in 5th-generation wireless systems, conservative whole-body exposure thresholds based on indirect evidence have been proposed. The guidelines define a whole-body average specific absorption rate (WBA-SAR) of 4 W/kg which causes a 1 °C increase in core temperature, as the operational threshold for adverse health effects. To address the lack of direct evidence, we recently reported that a 30-minute exposure to qMMW at 4.6 W/kg resulted in a 1 °C increase in rat core temperature. Here, we further analyzed the near-threshold stress response for the first time, using biological samples from the aforementioned and additional experiments.
METHODS:
A total of 59 young Sprague-Dawley rats (240-322 g) were exposed to 28 GHz for 40 minutes at WBA-SARs of 0, 3.7, and 7.2 W/kg, under normal (22.5 °C, 45-55% humidity), and heat (32 °C, 70% humidity) conditions. Rats were restrained in acrylic holders for dose control. We repeatedly measured serum and urinary biomarkers of stress response, aggregated the data, and analyzed them using a single statistical mixed model to subtract the effects of sham exposure and between-subject variation.
RESULTS:
Sham exposure induced stress responses, suggesting an effect of restraint. After the subtraction of the sham exposure effect, 28 GHz appeared to induce stress responses as evidenced by elevated serum-free corticosterone 1 or 3 days after the exposure, which was more evident in animals with a change in rectal temperature exceeding 1 °C. Urinary-free catecholamines demonstrated an inhibitory property of 28 GHz frequency exposure on the stress response as evidenced by noradrenaline on the day of exposure. Heat exposure enhanced this effect, suggesting a possible role of noradrenaline in heat dissipation by promoting cutaneous blood flow, a notion supported by the correlation between noradrenaline levels and tail surface temperature, a critical organ for heat dissipation.
CONCLUSIONS
This study is the first to demonstrate that qMMW whole-body exposure can alter the stress response as indicated by corticosterone and noradrenaline at near-threshold levels. Our findings may provide insight into the biological basis of the whole-body exposure thresholds in the international guidelines.
Animals
;
Rats
;
Rats, Sprague-Dawley
;
Male
;
Restraint, Physical
;
Stress, Physiological/radiation effects*
;
Corticosterone/blood*
;
Biomarkers/blood*
;
Microwaves/adverse effects*
5.Drainage for fluid collections post pancreatic surgery and acute pancreatitis: similar but different?
Yousuke NAKAI ; Saburo MATSUBARA ; Tsuyoshi MUKAI ; Tsuyoshi HAMADA ; Takashi SASAKI ; Hirotoshi ISHIWATARI ; Susumu HIJIOKA ; Hideyuki SHIOMI ; Mamoru TAKENAKA ; Takuji IWASHITA ; Atsuhiro MASUDA ; Tomotaka SAITO ; Hiroyuki ISAYAMA ; Ichiro YASUDA ;
Clinical Endoscopy 2024;57(6):735-746
Postoperative pancreatic fistulas (POPFs) are common adverse events that occur after pancreatic surgery. Endoscopic ultrasonography (EUS)-guided drainage (EUS-D) is a first-line treatment, similar to that for pancreatic fluid collection (PFCs) after acute pancreatitis. However, some POPFs do not develop fluid collections depending on the presence or location of the surgical drain, whereas others develop fluid collections, such as postoperative fluid collections (POPFCs). Although POPFCs are similar to PFCs, the strategy and modality for POPF management need to be modified according to the presence of fluid collections, surgical drains, and surgical type. As discussed for PFCs, the indications, timing, and selection of interventions or stents for EUS-D have not been fully elucidated for POPFs. In this review, we discuss the management of POPFs and POPFCs in comparison with PFCs due to acute pancreatitis and summarize the topics that should be addressed in future studies.
6.Drainage for fluid collections post pancreatic surgery and acute pancreatitis: similar but different?
Yousuke NAKAI ; Saburo MATSUBARA ; Tsuyoshi MUKAI ; Tsuyoshi HAMADA ; Takashi SASAKI ; Hirotoshi ISHIWATARI ; Susumu HIJIOKA ; Hideyuki SHIOMI ; Mamoru TAKENAKA ; Takuji IWASHITA ; Atsuhiro MASUDA ; Tomotaka SAITO ; Hiroyuki ISAYAMA ; Ichiro YASUDA ;
Clinical Endoscopy 2024;57(6):735-746
Postoperative pancreatic fistulas (POPFs) are common adverse events that occur after pancreatic surgery. Endoscopic ultrasonography (EUS)-guided drainage (EUS-D) is a first-line treatment, similar to that for pancreatic fluid collection (PFCs) after acute pancreatitis. However, some POPFs do not develop fluid collections depending on the presence or location of the surgical drain, whereas others develop fluid collections, such as postoperative fluid collections (POPFCs). Although POPFCs are similar to PFCs, the strategy and modality for POPF management need to be modified according to the presence of fluid collections, surgical drains, and surgical type. As discussed for PFCs, the indications, timing, and selection of interventions or stents for EUS-D have not been fully elucidated for POPFs. In this review, we discuss the management of POPFs and POPFCs in comparison with PFCs due to acute pancreatitis and summarize the topics that should be addressed in future studies.
7.Drainage for fluid collections post pancreatic surgery and acute pancreatitis: similar but different?
Yousuke NAKAI ; Saburo MATSUBARA ; Tsuyoshi MUKAI ; Tsuyoshi HAMADA ; Takashi SASAKI ; Hirotoshi ISHIWATARI ; Susumu HIJIOKA ; Hideyuki SHIOMI ; Mamoru TAKENAKA ; Takuji IWASHITA ; Atsuhiro MASUDA ; Tomotaka SAITO ; Hiroyuki ISAYAMA ; Ichiro YASUDA ;
Clinical Endoscopy 2024;57(6):735-746
Postoperative pancreatic fistulas (POPFs) are common adverse events that occur after pancreatic surgery. Endoscopic ultrasonography (EUS)-guided drainage (EUS-D) is a first-line treatment, similar to that for pancreatic fluid collection (PFCs) after acute pancreatitis. However, some POPFs do not develop fluid collections depending on the presence or location of the surgical drain, whereas others develop fluid collections, such as postoperative fluid collections (POPFCs). Although POPFCs are similar to PFCs, the strategy and modality for POPF management need to be modified according to the presence of fluid collections, surgical drains, and surgical type. As discussed for PFCs, the indications, timing, and selection of interventions or stents for EUS-D have not been fully elucidated for POPFs. In this review, we discuss the management of POPFs and POPFCs in comparison with PFCs due to acute pancreatitis and summarize the topics that should be addressed in future studies.
8.A novel fully covered metal stent for unresectable malignant distal biliary obstruction: results of a multicenter prospective study
Arata SAKAI ; Atsuhiro MASUDA ; Takaaki EGUCHI ; Keisuke FURUMATSU ; Takao IEMOTO ; Shiei YOSHIDA ; Yoshihiro OKABE ; Kodai YAMANAKA ; Ikuya MIKI ; Saori KAKUYAMA ; Yosuke YAGI ; Daisuke SHIRASAKA ; Shinya KOHASHI ; Takashi KOBAYASHI ; Hideyuki SHIOMI ; Yuzo KODAMA
Clinical Endoscopy 2024;57(3):375-383
Background/Aims:
Endoscopic self-expandable metal stent (SEMS) placement is currently the standard technique for treating unresectable malignant distal biliary obstructions (MDBO). Therefore, covered SEMS with longer stent patency and fewer migrations are required. This study aimed to assess the clinical performance of a novel, fully covered SEMS for unresectable MDBO.
Methods:
This was a multicenter single-arm prospective study. The primary outcome was a non-obstruction rate at 6 months. The secondary outcomes were overall survival (OS), recurrent biliary obstruction (RBO), time to RBO (TRBO), technical and clinical success, and adverse events.
Results:
A total of 73 patients were enrolled in this study. The non-obstruction rate at 6 months was 61%. The median OS and TRBO were 233 and 216 days, respectively. The technical and clinical success rates were 100% and 97%, respectively. Furthermore, the rate of occurrence of RBO and adverse events was 49% and 21%, respectively. The length of bile duct stenosis (<2.2 cm) was the only significant risk factor for stent migration.
Conclusions
The non-obstruction rate of a novel fully covered SEMS for MDBO is comparable to that reported earlier but shorter than expected. Short bile duct stenosis is a significant risk factor for stent migration.
9.Diffusion Tensor Imaging of the Spinal Canal in Quantitative Assessment of Patients with Lumbar Spinal Canal Stenosis
Masaki NORIMOTO ; Yawara EGUCHI ; Hirohito KANAMOTO ; Yasuhiro OIKAWA ; Koji MATSUMOTO ; Yoshitada MASUDA ; Takeo FURUYA ; Sumihisa ORITA ; Kazuhide INAGE ; Satoshi MAKI ; Yasuhiro SHIGA ; Hideyuki KINOSHITA ; Koki ABE ; Masahiro INOUE ; Tomotaka UMIMURA ; Takashi SATO ; Masashi SATO ; Masahiro SUZUKI ; Keigo ENOMOTO ; Seiji OHTORI
Asian Spine Journal 2021;15(2):207-215
Methods:
Study participants comprised five healthy volunteers (mean age, 27.2 years) and 27 patients with LSS (mean age, 58.4 years) who were individually assessed using 3.0 Tesla magnetic resonance imaging. Intraspinal ADC and FA values of 10 intervertebral discs from healthy volunteers and 52 intervertebral discs from LSS patients were measured. Also, intraspinal canal area, Schizas classification (A: normal, B: mild stenosis, C: severe stenosis) and correlations with symptoms were investigated. Clinical symptoms were checked for the presence of low back pain (LBP), intermittent claudication (IMC), and bladder and bowel dysfunction (BBD).
Results:
Compared to healthy individuals, LSS patients had significantly lower ADC (
10.Endoscopic Ultrasound-Guided Gastroenterostomy for Afferent Loop Syndrome
Hideyuki SHIOMI ; Arata SAKAI ; Ryota NAKANO ; Shogo OTA ; Takashi KOBAYASHI ; Atsuhiro MASUDA ; Hiroko IIJIMA
Clinical Endoscopy 2021;54(6):810-817
Afferent loop syndrome (ALS) is a mechanical obstruction of the afferent limbs after gastrectomy with gastrojejunostomy reconstruction. Patients with cancer recurrence require immediate and less invasive treatment because of their poor condition. Percutaneous transhepatic/transluminal drainage (PTD) and endoscopic enteral stenting offer reasonable palliative treatment for malignant ALS but are not fully satisfactory in terms of patient quality of life (QoL) and stent patency. Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) using a lumen-apposing metal stent may address these shortcomings. Clinical data from 11 reports showed that all patients who had undergone EUS-GE had positive technical and clinical outcomes. The adverse event rate was 11.4%, including only mild or moderate abdominal pain, with no severe adverse events. Indirect comparative studies indicated that patients who had undergone EUS-GE had a significantly superior QoL, a higher clinical success rate, and a lower reintervention rate than those who had undergone PTD or endoscopic enteral stenting. Although the evidence is limited, EUS-GE may be considered as a first-line treatment for malignant ALS because it has better clinical outcomes than other less invasive treatments, such as PTD or endoscopic enteral stenting. Further prospective randomized control trials are necessary to establish EUS-GE as a standard treatment for ALS.

Result Analysis
Print
Save
E-mail