1.Effect of transcutaneous electrical acupoint stimulation on postoperative pain in patients undergoing modified radical mastectomy for breast cancer.
Li YAN ; Bin SUN ; Meiyan ZHOU ; Yan ZHANG ; Fei GAO ; Qianwen ZHAO ; Liwei WANG
Chinese Acupuncture & Moxibustion 2025;45(2):162-166
OBJECTIVE:
To observe the effect of transcutaneous electrical acupoint stimulation (TEAS) on postoperative pain in patients undergoing modified radical mastectomy for breast cancer.
METHODS:
A total of 140 female patients scheduled for unilateral modified radical mastectomy for breast cancer undergoing general anesthesia were randomized into a TEAS group (70 cases) and a sham TEAS group (70 cases, 2 cases dropped out). Patients in both groups received TEAS or sham TEAS at bilateral Neiguan (PC6), Zusanli (ST36), and Danzhong (CV17), respectively, from 30 min before anesthesia induction until the end of surgery, and on 1st, 2nd, and 3rd days after surgery for 30 min a time, once a day. On 1st, 2nd, and 3rd days after surgery, the pain visual analogue scale (VAS) score was observed; on 3, 6, 12 months after surgery, the incidence rate of chronic pain was observed; before surgery, and on 1st, 3rd, and 7th days after surgery, the serum levels of tumor necrosis factor (TNF)-α, interleukin (IL)-6 and IL-10 were detected; the number of analgesia pump press, rescue analgesia, and the occurrence of adverse reaction after surgery were recorded in the two groups.
RESULTS:
In the TEAS group, the VAS scores on 1st and 2nd days after surgery, and the incidence rates of chronic pain on 3 and 6 months after surgery were lower than those in the sham TEAS group (P<0.05). On 1st, 3rd, and 7th days after surgery, the serum levels of TNF-α, IL-6, and IL-10 were increased compared with those before surgery in both groups (P<0.05, P<0.01); the above indexes in the TEAS group were lower than those in the sham TEAS group (P<0.05). The number of analgesia pump press and the incidence rate of rescue analgesia after surgery in the TEAS group were lower than those in the sham TEAS group (P<0.05). There was no statistically significant difference in the incidence of adverse reactions after surgery between the two groups (P>0.05).
CONCLUSION
TEAS can effectively improve both the postoperative acute pain and chronic pain in patients undergoing modified radical mastectomy for breast cancer, the mechanism may relate to inhibiting the inflammatory reaction.
Humans
;
Female
;
Acupuncture Points
;
Pain, Postoperative/blood*
;
Middle Aged
;
Breast Neoplasms/surgery*
;
Adult
;
Transcutaneous Electric Nerve Stimulation
;
Mastectomy, Modified Radical/adverse effects*
;
Interleukin-6/blood*
;
Tumor Necrosis Factor-alpha/blood*
;
Interleukin-10/blood*
;
Aged
2.Preventive effect of transcutaneous electro-acupuncture on the intratracheal extubation stress response in general anesthesia of patients with breast cancer undergoing modified radical mastectomy.
Hui-chang YU ; Wu-jun GENG ; Hong-li TANG
Chinese Journal of Integrated Traditional and Western Medicine 2009;29(11):990-992
OBJECTIVETo observe the regulatory effect of transcutaneous electro-acupuncture (TCEA) for preventing intratracheal extubation stress response (IESR) in general anesthesia.
METHODSSixty patients with breast cancer scheduled to receive mastectomy were numbered according to their sequence of hospitalization, patients of odd number were assigned to the control group and those of even number to the treated group, 30 in each group. They were anesthetized by the same anesthesia approach, but TCEA was applied on patients in the treated group in the narcotic process by stimulating at Hegu (LI4) and Neiguan (PC6) of the diseased side for 20 min before induction; then on bilateral points of Hegu, Neiguan, Chize (LU5) and Lieque (LU7) all through the whole course of operation, but at time of 30 min before ending operation, stimulus at Chize and Lieque points stopped and turned to bilateral Shuitu (ST10) and Qishe (ST11) points. No management other than conventional anesthesia was applied on patients in the control group. Changes of blood pressure (MAP), heart rate (HR), plasma catecholamine and cortisol as well as the respiratory tract response occurred after extubation were observed and compared.
RESULTSHR, MAP, plasma levels of catecholamine and cortisol increased after extubation in both groups (P < 0.05), but the changes were more obvious in the control group than in the treated group (P < 0.05). Besides, the adverse reaction of respiratory tract occurred in the treated group was milder (P < 0.05).
CONCLUSIONSTCEA can alleviate the IESR to attenuate the adverse reaction of respiratory tract. It is definitely valuable in clinical practice.
Acupuncture Points ; Airway Extubation ; Anesthetics, General ; adverse effects ; Breast Neoplasms ; surgery ; Electroacupuncture ; methods ; Female ; Humans ; Mastectomy, Modified Radical ; Stress, Physiological ; Transcutaneous Electric Nerve Stimulation ; methods

Result Analysis
Print
Save
E-mail