1.Recent Advancements in Balloon Enteroscopy-Assisted Endoscopic Retrograde Cholangiopancreatography for Patients with Surgically Altered Anatomy
Yuki TANISAKA ; Shomei RYOZAWA ; Masafumi MIZUIDE ; Akashi FUJITA ; Ryuichi WATANABE ; Ryosuke HAMAMURA
Korean Journal of Pancreas and Biliary Tract 2026;31(2):65-72
Endoscopic retrograde cholangiopancreatography (ERCP) in patients with surgically altered anatomy (SAA) is technically challenging, not only because of the difficulty in reaching the target site but also in performing subsequent therapeutic procedures. To overcome these challenges, balloon enteroscopy-assisted ERCP has been introduced into clinical practice and has been reported to be both effective and safe. Recently, short-type balloon enteroscopes, with a working length of approximately 150 cm and a 3.2-mm working channel, have been widely adopted, making procedures more efficient. These short-type scopes facilitate the use of larger accessories in various procedures, such as stone extraction or self-expandable metallic stent placement. In addition, several new technologies and devices have recently been introduced to help manage difficult cases. Despite these advancements, multiple technical hurdles remain before procedures can be successfully completed. It is important to identify the key factors that contribute to procedural difficulty in order to improve success rates. At the same time, endoscopists must remain aware of the potential for adverse events, such as perforation, which can occur due to adhesions specific to SAA. In this review, we provide technical tips for short-type single-balloon enteroscopy-assisted ERCP in patients with SAA, aimed at improving procedural success rates and reducing adverse events, while also highlighting recent advancements in technology and devices.
3.Effectiveness of endoscopic ultrasound-guided tissue acquisition with stereomicroscopic on-site evaluation for preoperative diagnosis of resectable or borderline resectable pancreatic cancer: a prospective study
Junro ISHIZAKI ; Kosuke OKUWAKI ; Masafumi WATANABE ; Hiroshi IMAIZUMI ; Tomohisa IWAI ; Rikiya HASEGAWA ; Takahiro KUROSU ; Masayoshi TADEHARA ; Takaaki MATSUMOTO ; Kai ADACHI ; Taro HANAOKA ; Mitsuhiro KIDA ; Chika KUSANO
Clinical Endoscopy 2024;57(6):807-813
Background/Aims:
To validate endoscopic ultrasound-guided tissue acquisition (EUS-TA) used in conjunction with stereomicroscopic on-site evaluation (SOSE) as a preoperative diagnostic tool for resectable pancreatic cancer (R-PC) and borderline resectable PC (BR-PC).
Methods:
Seventy-eight consecutive patients who underwent EUS-TA for suspected R-PC or BR-PC were enrolled. The primary endpoint was the sensitivity of EUS-TA together with SOSE based on the stereomicroscopically visible white core (SVWC) cutoff value. One or two sites were punctured by using a 22-gauge biopsy needle for EUS-TA, based on the SOSE findings.
Results:
We collected 99 specimens from 56 and 22 patients with R-PC and BR-PC, respectively. Based on the SOSE results, we performed 57 procedures with one puncture. The SVWC cutoff values were met in 73.7% and 73.1% of all specimens and in those obtained during the first puncture, respectively. The final diagnoses were malignant and benign tumors in 76 and two patients, respectively. The overall sensitivity, specificity, and accuracy of EUS-TA for the 78 lesions were 90.8%, 100%, and 91.0%, respectively. The sensitivity for malignant diagnosis based on the SVWC cutoff value were 89.5% and 90.4% for the first puncture and all specimens, respectively.
Conclusions
The sensitivity of EUS-TA in conjunction with SOSE for malignancy diagnosis in patients with suspected R-PC or BR-PC was 90.4%.
4.Effectiveness of endoscopic ultrasound-guided tissue acquisition with stereomicroscopic on-site evaluation for preoperative diagnosis of resectable or borderline resectable pancreatic cancer: a prospective study
Junro ISHIZAKI ; Kosuke OKUWAKI ; Masafumi WATANABE ; Hiroshi IMAIZUMI ; Tomohisa IWAI ; Rikiya HASEGAWA ; Takahiro KUROSU ; Masayoshi TADEHARA ; Takaaki MATSUMOTO ; Kai ADACHI ; Taro HANAOKA ; Mitsuhiro KIDA ; Chika KUSANO
Clinical Endoscopy 2024;57(6):807-813
Background/Aims:
To validate endoscopic ultrasound-guided tissue acquisition (EUS-TA) used in conjunction with stereomicroscopic on-site evaluation (SOSE) as a preoperative diagnostic tool for resectable pancreatic cancer (R-PC) and borderline resectable PC (BR-PC).
Methods:
Seventy-eight consecutive patients who underwent EUS-TA for suspected R-PC or BR-PC were enrolled. The primary endpoint was the sensitivity of EUS-TA together with SOSE based on the stereomicroscopically visible white core (SVWC) cutoff value. One or two sites were punctured by using a 22-gauge biopsy needle for EUS-TA, based on the SOSE findings.
Results:
We collected 99 specimens from 56 and 22 patients with R-PC and BR-PC, respectively. Based on the SOSE results, we performed 57 procedures with one puncture. The SVWC cutoff values were met in 73.7% and 73.1% of all specimens and in those obtained during the first puncture, respectively. The final diagnoses were malignant and benign tumors in 76 and two patients, respectively. The overall sensitivity, specificity, and accuracy of EUS-TA for the 78 lesions were 90.8%, 100%, and 91.0%, respectively. The sensitivity for malignant diagnosis based on the SVWC cutoff value were 89.5% and 90.4% for the first puncture and all specimens, respectively.
Conclusions
The sensitivity of EUS-TA in conjunction with SOSE for malignancy diagnosis in patients with suspected R-PC or BR-PC was 90.4%.
5.Stereomicroscopic on-site evaluation in endoscopic ultrasound-guided tissue acquisition of upper gastrointestinal subepithelial lesions
Seigo NAKATANI ; Kosuke OKUWAKI ; Masafumi WATANABE ; Hiroshi IMAIZUMI ; Tomohisa IWAI ; Takaaki MATSUMOTO ; Rikiya HASEGAWA ; Hironori MASUTANI ; Takahiro KUROSU ; Akihiro TAMAKI ; Junro ISHIZAKI ; Ayana ISHIZAKI ; Mitsuhiro KIDA ; Chika KUSANO
Clinical Endoscopy 2024;57(1):89-95
Background/Aims:
In stereomicroscopic sample isolation processing, the cutoff value (≥4 mm) of stereomicroscopically visible white cores indicates high diagnostic sensitivity. We aimed to evaluate endoscopic ultrasound-guided tissue acquisition (EUS-TA) using a simplified stereomicroscopic on-site evaluation of upper gastrointestinal subepithelial lesions (SELs).
Methods:
In this multicenter prospective trial, we performed EUS-TA using a 22-gauge Franseen needle in 34 participants with SELs derived from the upper gastrointestinal muscularis propria, requiring pathological diagnosis. The presence of stereomicroscopically visible white core (SVWC) in each specimen was assessed using stereomicroscopic on-site evaluation. The primary outcome was EUS-TA’s diagnostic sensitivity with stereomicroscopic on-site evaluation based on the SVWC cutoff value (≥4 mm) for malignant upper gastrointestinal SELs.
Results:
The total number of punctures was 68; 61 specimens (89.7%) contained stereomicroscopically visible white cores ≥4 mm in size. The final diagnoses were gastrointestinal stromal tumor, leiomyoma, and schwannoma in 76.5%, 14.7%, and 8.8% of the cases, respectively. The sensitivity of EUS-TA with stereomicroscopic on-site evaluation based on the SVWC cutoff value for malignant SELs was 100%. The per-lesion accuracy of histological diagnosis reached the highest level (100%) at the second puncture.
Conclusions
Stereomicroscopic on-site evaluation showed high diagnostic sensitivity and could be a new method for diagnosing upper gastrointestinal SELs using EUS-TA.
6.Effectiveness of endoscopic ultrasound-guided tissue acquisition with stereomicroscopic on-site evaluation for preoperative diagnosis of resectable or borderline resectable pancreatic cancer: a prospective study
Junro ISHIZAKI ; Kosuke OKUWAKI ; Masafumi WATANABE ; Hiroshi IMAIZUMI ; Tomohisa IWAI ; Rikiya HASEGAWA ; Takahiro KUROSU ; Masayoshi TADEHARA ; Takaaki MATSUMOTO ; Kai ADACHI ; Taro HANAOKA ; Mitsuhiro KIDA ; Chika KUSANO
Clinical Endoscopy 2024;57(6):807-813
Background/Aims:
To validate endoscopic ultrasound-guided tissue acquisition (EUS-TA) used in conjunction with stereomicroscopic on-site evaluation (SOSE) as a preoperative diagnostic tool for resectable pancreatic cancer (R-PC) and borderline resectable PC (BR-PC).
Methods:
Seventy-eight consecutive patients who underwent EUS-TA for suspected R-PC or BR-PC were enrolled. The primary endpoint was the sensitivity of EUS-TA together with SOSE based on the stereomicroscopically visible white core (SVWC) cutoff value. One or two sites were punctured by using a 22-gauge biopsy needle for EUS-TA, based on the SOSE findings.
Results:
We collected 99 specimens from 56 and 22 patients with R-PC and BR-PC, respectively. Based on the SOSE results, we performed 57 procedures with one puncture. The SVWC cutoff values were met in 73.7% and 73.1% of all specimens and in those obtained during the first puncture, respectively. The final diagnoses were malignant and benign tumors in 76 and two patients, respectively. The overall sensitivity, specificity, and accuracy of EUS-TA for the 78 lesions were 90.8%, 100%, and 91.0%, respectively. The sensitivity for malignant diagnosis based on the SVWC cutoff value were 89.5% and 90.4% for the first puncture and all specimens, respectively.
Conclusions
The sensitivity of EUS-TA in conjunction with SOSE for malignancy diagnosis in patients with suspected R-PC or BR-PC was 90.4%.
7.Cross-sectional area of psoas muscle as a predictive marker of anastomotic failure in male rectal cancer patients: Japanese single institutional retrospective observational study
Yusuke MIZUUCHI ; Yoshitaka TANABE ; Masafumi SADA ; Koji TAMURA ; Kinuko NAGAYOSHI ; Shuntaro NAGAI ; Yusuke WATANABE ; Sadafumi TAMIYA ; Kohei NAKATA ; Kenoki OHUCHIDA ; Toru NAKANO ; Masafumi NAKAMURA
Annals of Coloproctology 2022;38(5):353-361
Purpose:
Preoperative sarcopenia worsens postoperative outcomes in various cancer types including colorectal cancer. However, we often experienced postoperative anastomotic leakage in muscular male patients such as Judo players, especially in rectal cancer surgery with lower anastomosis. It is controversial whether the whole skeletal muscle mass impacts the potential for anastomotic failure in male rectal cancer patients. Thus, the purpose of this study was to clarify whether skeletal muscle mass impacts anastomotic leakage in rectal cancer in men.
Methods:
We reviewed the medical charts of male patients suffering from rectal cancer who underwent colo-procto anastomosis below the peritoneal reflection without a protective diverting stoma. We measured the psoas muscle area and calculated the psoas muscle index.
Results:
One hundred ninety-seven male rectal cancer patients were enrolled in this study. The psoas muscle index was significantly higher in patients with anastomotic leakage (P<0.001). Receiver operating characteristic curve determined the optimal cut-off value of the psoas muscle index for predicting anastomotic leakage as 812.67 cm2/m2 (sensitivity of 60% and specificity of 74.3%). Multivariate analysis revealed that high psoas muscle index (risk ratio [RR], 3.933; P<0.001; 95% confidence interval [CI], 1.917–8.070) and super low anastomosis (RR, 2.792; P=0.015; 95% CI, 1.221–6.384) were independent predictive factors of anastomotic leakage.
Conclusion
This study showed that male rectal cancer patients with a large psoas muscle mass who underwent lower anastomosis had a higher rate of postoperative anastomotic leakage.
8.Cholecystitis after Placement of Covered Self-Expandable Metallic Stents in Patients with Distal Malignant Biliary Obstructions
Masafumi WATANABE ; Kosuke OKUWAKI ; Jun WOO ; Mitsuhiro KIDA ; Hiroshi IMAIZUMI ; Tomohisa IWAI ; Hiroshi YAMAUCHI ; Toru KANEKO ; Rikiya HASEGAWA ; Takahiro KUROSU ; Naoki MINATO ; Hiroki HARADOME ; Wasaburo KOIZUMI
Clinical Endoscopy 2021;54(4):589-595
Background/Aims:
Cholecystitis can occur after the placement of covered self-expandable metallic stents for distal malignant biliary obstructions. We aimed to identify risk factors for cholecystitis following covered self-expandable metallic stent placement.
Methods:
We investigated risk factors related to cholecystitis following covered self-expandable metallic stent placement in 118 patients with distal malignant biliary obstructions between January 1, 2015 and April 30, 2019. Endoscopic assessments and tumor invasion to the arteries feeding the gallbladder were determined by a pancreaticobiliary endoscopist and a radiologist, respectively.
Results:
The median patient age was 72 years (men, 61.0%). The flow of the contrast agent into the gallbladder and tumor involvement in the orifice of the cystic duct were observed in 35 (29.7%) and 35 (29.7%) patients, respectively. During the observation period (median, 179 days), cholecystitis occurred in 18 (15.3%) patients. Multivariate analysis revealed the flow of the contrast agent into the gallbladder (p=0.023) and tumor involvement in the orifice of the cystic duct (p=0.005) as significant independent risk factors associated with cholecystitis.
Conclusions
The flow of the contrast agent into the gallbladder and tumor involvement in the orifice of the cystic duct are potential independent risk factors for cholecystitis following the placement of covered self-expandable metallic stents. A follow-up prospective study is warranted to validate their influence.
9.Cholecystitis after Placement of Covered Self-Expandable Metallic Stents in Patients with Distal Malignant Biliary Obstructions
Masafumi WATANABE ; Kosuke OKUWAKI ; Jun WOO ; Mitsuhiro KIDA ; Hiroshi IMAIZUMI ; Tomohisa IWAI ; Hiroshi YAMAUCHI ; Toru KANEKO ; Rikiya HASEGAWA ; Takahiro KUROSU ; Naoki MINATO ; Hiroki HARADOME ; Wasaburo KOIZUMI
Clinical Endoscopy 2021;54(4):589-595
Background/Aims:
Cholecystitis can occur after the placement of covered self-expandable metallic stents for distal malignant biliary obstructions. We aimed to identify risk factors for cholecystitis following covered self-expandable metallic stent placement.
Methods:
We investigated risk factors related to cholecystitis following covered self-expandable metallic stent placement in 118 patients with distal malignant biliary obstructions between January 1, 2015 and April 30, 2019. Endoscopic assessments and tumor invasion to the arteries feeding the gallbladder were determined by a pancreaticobiliary endoscopist and a radiologist, respectively.
Results:
The median patient age was 72 years (men, 61.0%). The flow of the contrast agent into the gallbladder and tumor involvement in the orifice of the cystic duct were observed in 35 (29.7%) and 35 (29.7%) patients, respectively. During the observation period (median, 179 days), cholecystitis occurred in 18 (15.3%) patients. Multivariate analysis revealed the flow of the contrast agent into the gallbladder (p=0.023) and tumor involvement in the orifice of the cystic duct (p=0.005) as significant independent risk factors associated with cholecystitis.
Conclusions
The flow of the contrast agent into the gallbladder and tumor involvement in the orifice of the cystic duct are potential independent risk factors for cholecystitis following the placement of covered self-expandable metallic stents. A follow-up prospective study is warranted to validate their influence.
10.10-11 Having Residents under the COVID-19 Pandemic - Experiences in the Spring of 2020
Kayoko MATSUSHIMA ; Eriko OZONO ; Yusuke MATSUZAKA ; Syoko ASHIZUKA ; Noriko SHIGETOMI ; Toshimasa SHIMIZU ; Masafumi HARAGUCHI ; Takeshi WATANABE ; Takashi MIYAMOTO ; Hayato TAKAYAMA ; Kenichi KANEKO ; Yuji KOIDE ; Atsuko NAGATANI ; Hisayuki HAMADA
Medical Education 2020;51(3):331-333


Result Analysis
Print
Save
E-mail