1.The relationship between activities of daily living and mental health in community elderly people and the mediating role of sleep quality
Heng-Yi ZHOU ; Jing LI ; Dan-Hua DAI ; Yang LI ; Bin ZHANG ; Rong DU ; Rui-Long WU ; Jia-Yan JIANG ; Yuan-Man WEI ; Jing-Rong GAO ; Qi ZHAO
Fudan University Journal of Medical Sciences 2024;51(2):143-150
Objective To explore the relationship and internal path between activities of daily living(ADL),sleep quality and mental health of community elderly people in Shanghai.Methods A questionnaire survey was conducted among community residents aged 60 years and older seeing doctors in community health care center of five streets in Shanghai during Sept to Dec,2021 using convenience sampling.Activities of Daily Living(ADL),Pittsburgh Sleep Quality Index(PSQI)and 10-item Kessler Psychological Distress Scale(K10)were adopted in the survey.Single factor analysis,correlation analysis and multiple linear regression were used to analyze the data.The effect relationship between the variables was tested using Bootstrap's mediated effects test.Results A total of 1 864 participants were included in the study.The average score was 15.53±4.47 for ADL,5.60±3.71 for PSQI and 15.50±6.28 for K10.The rate of ADL impairment,poor sleep quality,poor and very poor mental health of the elderly were 23.6%,27.3%,11.9%and 4.9%,respectively.ADL and sleep quality were all positively correlated with mental health(r=0.321,P<0.001;r=0.466,P<0.001);ADL was positively correlated with sleep quality(r=0.294,P<0.001).Multiple linear results of factors influencing mental health showed that ADL(β= 0.457,95%CI:0.341-0.573),sleep quality(β =0.667,95%CI:0.598-0.737)and mental health were positively correlated(P<0.001).Sleep quality partially mediated the relationship between ADL and mental health(95%CI:0.078-0.124)with an effect size of 33.0%.Conclusion Sleep quality is a mediator between ADL and mental health among community elderly people.Improving ADL and sleep quality may improve mental health in the population.
2.Efficacy and safety of CM310 in moderate-to-severe atopic dermatitis: A multicenter, randomized, double-blind, placebo-controlled phase 2b trial
Yan ZHAO ; Jianzhong ZHANG ; Bin YANG ; Jingyi LI ; Yangfeng DING ; Liming WU ; Litao ZHANG ; Jinyan WANG ; Xiaohong ZHU ; Furen ZHANG ; Xiaohua TAO ; Yumei LI ; Chunlei ZHANG ; Linfeng LI ; Jianyun LU ; Qingchun DIAO ; Qianjin LU ; Xiaoyong MAN ; Fuqiu LI ; Xiujuan XIA ; Hao CHENG ; Yingmin JIA ; Guoqing ZHAO ; Jinchun YAN ; Bo CHEN
Chinese Medical Journal 2024;137(2):200-208
Background::Atopic dermatitis (AD) affects approximately 10% of adults worldwide. CM310 is a humanized monoclonal antibody targeting interleukin-4 receptor alpha that blocks interleukin-4 and interleukin-13 signaling. This trial aimed to evaluate the efficacy and safety of CM310 in Chinese adults with moderate-to-severe AD.Methods::This multicenter, randomized, double-blind, placebo-controlled, phase 2b trial was conducted in 21 medical institutions in China from February to November 2021. Totally 120 eligible patients were enrolled and randomized (1:1:1) to receive subcutaneous injections of 300 mg CM310, 150 mg CM310, or placebo every 2 weeks for 16 weeks, followed by an 8-week follow-up period. The primary endpoint was the proportion of patients achieving ≥75% improvement in the Eczema Area and Severity Index (EASI-75) score from baseline at week 16. Safety and pharmacodynamics were also studied.Results::At week 16, the proportion of EASI-75 responders from baseline was significantly higher in the CM310 groups (70% [28/40] for high-dose and 65% [26/40] for low-dose) than that in the placebo group (20%[8/40]). The differences in EASI-75 response rate were 50% (high vs. placebo, 95% CI 31%–69%) and 45% (low vs. placebo, 95% CI 26%–64%), with both P values <0.0001. CM310 at both doses also significantly improved the EASI score, Investigator’s Global Assessment score, daily peak pruritus Numerical Rating Scale, AD-affected body surface area, and Dermatology Life Quality Index compared with placebo. CM310 treatment reduced levels of thymus and activation-regulated chemokine, total immunoglobulin E, lactate dehydrogenase, and blood eosinophils. The incidence of treatment-emergent adverse events (TEAEs) was similar among all three groups, with the most common TEAEs reported being upper respiratory tract infection, atopic dermatitis, hyperlipidemia, and hyperuricemia. No severe adverse events were deemed to be attributed to CM310. Conclusion::CM310 at 150 mg and 300 mg every 2 weeks demonstrated significant efficacy and was well-tolerated in adults with moderate-to-severe AD.Trial Registration::ClinicalTrials.gov, NCT04805411.
3.Early experience with mechanical hemodynamic support for catheter ablation of malignant ventricular tachycardia
Mengmeng LI ; Yang YANG ; Deyong LONG ; Chenxi JIANG ; Ribo TANG ; Caihua SANG ; Wei WANG ; Xin ZHAO ; Xueyuan GUO ; Songnan LI ; Changyi LI ; Man NING ; Changqi JIA ; Li FENG ; Dan WEN ; Hui ZHU ; Yuexin JIANG ; Fang LIU ; Tong LIU ; Jianzeng DONG ; Changsheng MA
Chinese Journal of Cardiology 2024;52(7):768-776
Objective:To explore the role of mechanical hemodynamic support (MHS) in mapping and catheter ablation of patients with hemodynamically unstable ventricular tachycardia (VT), report single-center experience in a cohort of consecutive patients receiving VT ablation during MHS therapy, and provide evidence-based medical evidence for clinical practice.Methods:This was a retrospective cohort study. Patients with hemodynamically unstable VT who underwent catheter ablation with MHS at Beijing Anzhen Hospital, Capital Medical University between August 2021 and December 2023 were included. Patients were divided into rescue group and preventive group according to the purpose of treatment. Their demographic data, periprocedural details, and clinical outcomes were collected and analyzed.Results:A total of 15 patients with hemodynamically unstable VT were included (8 patients in the rescue group and 7 patients in the preventive group). The acute procedure was successful in all patients. One patient in the rescue group had surgical left ventricular assist device (LVAD) implantation, remaining 14 patients received extracorporeal membrane oxygenation (ECMO) for circulation support. ECMO decannulation was performed in 12 patients due to clinical and hemodynamic stability, of which 6 patients were decannulation immediately after surgery and the remaining patients were decannulation at 2.0 (2.5) d after surgery. Two patients in the rescue group died during the index admission due to refractory heart failure and cerebral hemorrhage. During a median follow-up of 30 d (1 d to 12 months), one patient with LVAD had one episode of ventricular fibrillation at 6 months after discharge, and no further episodes of ventricular fibrillation and/or VT occurred after treatment with antiarrhythmic drugs. No malignant ventricular arrhythmia occurred in the remaining 12 patients who were followed up.Conclusions:MHS contributes to the successful completion of mapping and catheter ablation in patients with hemodynamically unstable VT, providing desirable hemodynamic status for emergency and elective conditions.
4.Associations between carotid plaque shape, biomechanical parameters, and ischemic stroke in mild carotid stenosis with a single plaque
Man ZHAO ; Luni ZHANG ; Jing CHEN ; Shiyao GU ; Rong WU ; Caixia JIA
Ultrasonography 2024;43(3):209-219
Purpose:
This cross-sectional cohort-comparison observational study investigated the value of high-frame-rate vector flow (V Flow) imaging for evaluating differences in carotid plaque shape and biomechanical parameters in patients with mild stenosis according to a recent history of ipsilateral ischemic stroke.
Methods:
The present study included 352 patients from February 2023 to October 2023, who were categorized as symptomatic or asymptomatic based on a history of recent ischemic stroke and ipsilateral ischemic lesions detected on head computed tomography or magnetic resonance imaging. A Mindray Resona R9 system was used for B-mode ultrasonography and V Flow imaging. The upstream and downstream surfaces of the plaques were examined at the carotid bifurcation for wall shear stress (WSS), oscillatory shear index (OSI), and turbulence index, which performed peri-plaque biomechanical condition. Multivariable logistic regression models were used to determine associations between plaque shape, V Flow parameters, and ischemic stroke.
Results:
Symptomatic patients exhibited higher WSS values for the upstream and downstream surfaces of carotid plaque, as well as higher OSI and turbulence index values for the downstream surface. Type Ⅲ plaques and higher WSS and OSI values for the downstream surface of the plaque were significantly associated with ischemic stroke. Type Ⅲ plaques were more prevalent in symptomatic patients and demonstrated much higher WSS and OSI values for the downstream plaque surface in both groups.
Conclusion
High-frame-rate V Flow imaging could assess peri-plaque biomechanical forces and may provide effective imaging biomarkers for early prediction of ischemic stroke in patients with mild stenosis.
5.Associations between carotid plaque shape, biomechanical parameters, and ischemic stroke in mild carotid stenosis with a single plaque
Man ZHAO ; Luni ZHANG ; Jing CHEN ; Shiyao GU ; Rong WU ; Caixia JIA
Ultrasonography 2024;43(3):209-219
Purpose:
This cross-sectional cohort-comparison observational study investigated the value of high-frame-rate vector flow (V Flow) imaging for evaluating differences in carotid plaque shape and biomechanical parameters in patients with mild stenosis according to a recent history of ipsilateral ischemic stroke.
Methods:
The present study included 352 patients from February 2023 to October 2023, who were categorized as symptomatic or asymptomatic based on a history of recent ischemic stroke and ipsilateral ischemic lesions detected on head computed tomography or magnetic resonance imaging. A Mindray Resona R9 system was used for B-mode ultrasonography and V Flow imaging. The upstream and downstream surfaces of the plaques were examined at the carotid bifurcation for wall shear stress (WSS), oscillatory shear index (OSI), and turbulence index, which performed peri-plaque biomechanical condition. Multivariable logistic regression models were used to determine associations between plaque shape, V Flow parameters, and ischemic stroke.
Results:
Symptomatic patients exhibited higher WSS values for the upstream and downstream surfaces of carotid plaque, as well as higher OSI and turbulence index values for the downstream surface. Type Ⅲ plaques and higher WSS and OSI values for the downstream surface of the plaque were significantly associated with ischemic stroke. Type Ⅲ plaques were more prevalent in symptomatic patients and demonstrated much higher WSS and OSI values for the downstream plaque surface in both groups.
Conclusion
High-frame-rate V Flow imaging could assess peri-plaque biomechanical forces and may provide effective imaging biomarkers for early prediction of ischemic stroke in patients with mild stenosis.
6.Associations between carotid plaque shape, biomechanical parameters, and ischemic stroke in mild carotid stenosis with a single plaque
Man ZHAO ; Luni ZHANG ; Jing CHEN ; Shiyao GU ; Rong WU ; Caixia JIA
Ultrasonography 2024;43(3):209-219
Purpose:
This cross-sectional cohort-comparison observational study investigated the value of high-frame-rate vector flow (V Flow) imaging for evaluating differences in carotid plaque shape and biomechanical parameters in patients with mild stenosis according to a recent history of ipsilateral ischemic stroke.
Methods:
The present study included 352 patients from February 2023 to October 2023, who were categorized as symptomatic or asymptomatic based on a history of recent ischemic stroke and ipsilateral ischemic lesions detected on head computed tomography or magnetic resonance imaging. A Mindray Resona R9 system was used for B-mode ultrasonography and V Flow imaging. The upstream and downstream surfaces of the plaques were examined at the carotid bifurcation for wall shear stress (WSS), oscillatory shear index (OSI), and turbulence index, which performed peri-plaque biomechanical condition. Multivariable logistic regression models were used to determine associations between plaque shape, V Flow parameters, and ischemic stroke.
Results:
Symptomatic patients exhibited higher WSS values for the upstream and downstream surfaces of carotid plaque, as well as higher OSI and turbulence index values for the downstream surface. Type Ⅲ plaques and higher WSS and OSI values for the downstream surface of the plaque were significantly associated with ischemic stroke. Type Ⅲ plaques were more prevalent in symptomatic patients and demonstrated much higher WSS and OSI values for the downstream plaque surface in both groups.
Conclusion
High-frame-rate V Flow imaging could assess peri-plaque biomechanical forces and may provide effective imaging biomarkers for early prediction of ischemic stroke in patients with mild stenosis.
7.Associations between carotid plaque shape, biomechanical parameters, and ischemic stroke in mild carotid stenosis with a single plaque
Man ZHAO ; Luni ZHANG ; Jing CHEN ; Shiyao GU ; Rong WU ; Caixia JIA
Ultrasonography 2024;43(3):209-219
Purpose:
This cross-sectional cohort-comparison observational study investigated the value of high-frame-rate vector flow (V Flow) imaging for evaluating differences in carotid plaque shape and biomechanical parameters in patients with mild stenosis according to a recent history of ipsilateral ischemic stroke.
Methods:
The present study included 352 patients from February 2023 to October 2023, who were categorized as symptomatic or asymptomatic based on a history of recent ischemic stroke and ipsilateral ischemic lesions detected on head computed tomography or magnetic resonance imaging. A Mindray Resona R9 system was used for B-mode ultrasonography and V Flow imaging. The upstream and downstream surfaces of the plaques were examined at the carotid bifurcation for wall shear stress (WSS), oscillatory shear index (OSI), and turbulence index, which performed peri-plaque biomechanical condition. Multivariable logistic regression models were used to determine associations between plaque shape, V Flow parameters, and ischemic stroke.
Results:
Symptomatic patients exhibited higher WSS values for the upstream and downstream surfaces of carotid plaque, as well as higher OSI and turbulence index values for the downstream surface. Type Ⅲ plaques and higher WSS and OSI values for the downstream surface of the plaque were significantly associated with ischemic stroke. Type Ⅲ plaques were more prevalent in symptomatic patients and demonstrated much higher WSS and OSI values for the downstream plaque surface in both groups.
Conclusion
High-frame-rate V Flow imaging could assess peri-plaque biomechanical forces and may provide effective imaging biomarkers for early prediction of ischemic stroke in patients with mild stenosis.
8.Associations between carotid plaque shape, biomechanical parameters, and ischemic stroke in mild carotid stenosis with a single plaque
Man ZHAO ; Luni ZHANG ; Jing CHEN ; Shiyao GU ; Rong WU ; Caixia JIA
Ultrasonography 2024;43(3):209-219
Purpose:
This cross-sectional cohort-comparison observational study investigated the value of high-frame-rate vector flow (V Flow) imaging for evaluating differences in carotid plaque shape and biomechanical parameters in patients with mild stenosis according to a recent history of ipsilateral ischemic stroke.
Methods:
The present study included 352 patients from February 2023 to October 2023, who were categorized as symptomatic or asymptomatic based on a history of recent ischemic stroke and ipsilateral ischemic lesions detected on head computed tomography or magnetic resonance imaging. A Mindray Resona R9 system was used for B-mode ultrasonography and V Flow imaging. The upstream and downstream surfaces of the plaques were examined at the carotid bifurcation for wall shear stress (WSS), oscillatory shear index (OSI), and turbulence index, which performed peri-plaque biomechanical condition. Multivariable logistic regression models were used to determine associations between plaque shape, V Flow parameters, and ischemic stroke.
Results:
Symptomatic patients exhibited higher WSS values for the upstream and downstream surfaces of carotid plaque, as well as higher OSI and turbulence index values for the downstream surface. Type Ⅲ plaques and higher WSS and OSI values for the downstream surface of the plaque were significantly associated with ischemic stroke. Type Ⅲ plaques were more prevalent in symptomatic patients and demonstrated much higher WSS and OSI values for the downstream plaque surface in both groups.
Conclusion
High-frame-rate V Flow imaging could assess peri-plaque biomechanical forces and may provide effective imaging biomarkers for early prediction of ischemic stroke in patients with mild stenosis.
9.The timing of pericardial drainage catheter removal and restart of the anticoagulation in patients suffered from perioperative pericardial tamponade during atrial fibrillation catheter ablation and uninterrupted dabigatran: Experiences from 20 cases.
Xin ZHAO ; Wen Li DAI ; Xin SU ; Jia Hui WU ; Chang Qi JIA ; Li FENG ; Man NING ; Yan Fei RUAN ; Song ZUO ; Rong HU ; Xin DU ; Jian Zeng DONG ; Chang Sheng MA
Chinese Journal of Cardiology 2023;51(1):45-50
Objective: To investigate the timing of pericardial drainage catheter removal and restart of the anticoagulation in patients with atrial fibrillation (AF) suffered from perioperative pericardial tamponade during atrial fibrillation catheter ablation and uninterrupted dabigatran. Methods: A total of 20 patients with pericardial tamponade, who underwent AF catheter ablation with uninterrupted dabigatran in Beijing Anzhen Hospital from January 2019 to August 2021, were included in this retrospective analysis. The clinical characteristics of enrolled patients, information of catheter ablation procedures, pericardial tamponade management, perioperative complications, the timing of pericardial drainage catheter removal and restart of anticoagulation were analyzed. Results: All patients underwent pericardiocentesis and pericardial effusion drainage was successful in all patients. The average drainage volume was (427.8±527.4) ml. Seven cases were treated with idarucizumab, of which 1 patient received surgical repair. The average timing of pericardial drainage catheter removal and restart of anticoagulation in 19 patients without surgical repair was (1.4±0.7) and (0.8±0.4) days, respectively. No new bleeding, embolism and death were reported during hospitalization and within 30 days following hospital discharge. Time of removal of pericardial drainage catheter, restart of anticoagulation and hospital stay were similar between patients treated with idarucizumab or not. Conclusion: It is safe and reasonable to remove pericardial drainage catheter and restart anticoagulation as soon as possible during catheter ablation of atrial fibrillation with uninterrupted dabigatran independent of the idarucizumab use or not in case of confirmed hemostasis.
Humans
;
Atrial Fibrillation/drug therapy*
;
Dabigatran/therapeutic use*
;
Cardiac Tamponade/complications*
;
Anticoagulants/therapeutic use*
;
Retrospective Studies
;
Treatment Outcome
;
Drainage/adverse effects*
;
Catheter Ablation
;
Catheters/adverse effects*
10.Research progress in targeting autophagy of traditional Chinese medicine and natural compounds to regulate atherosclerosis.
Man-Li ZHOU ; Yun-Feng YU ; Yan-Zhen ZHAO ; Xiao-Xin LUO ; Jia-le ZHU ; Yi-Lei HU ; Wei-Xiong JIAN
China Journal of Chinese Materia Medica 2023;48(2):311-320
Atherosclerosis(AS) is the common pathological basis of many ischemic cardiovascular diseases, and its formation process involves various aspects such as vascular endothelial injury and platelet activation. Vascular endothelial injury is the initiating factor of AS plaque. Monocytes are recruited to differentiate into macrophages at the damaged endothelial cells, which absorb oxidized low-density lipoprotein(ox-LDL) and slowly transform into foam cells. Smooth muscle cells(SMCs) proliferate and migrate continuously. As the only cell producing interstitial collagen fibers in the fibrous cap, SMCs largely determine whether the plaque ruptured or not. The amplifying inflammatory response during the formation of AS recruits platelets to adhere to the damaged area of vascular endothelium and stimulates excessive platelet aggregation. Autophagy activity is associated with vascular lesions and abnormal platelet activation, and excessive autophagy is considered to be a negative factor for plaque stability. Therefore, precise regulation of different types of vascular autophagy and platelet autophagy to treat AS may provide a new therapeutic perspective for the prevention and treatment of atherosclerotic ischemic cardiovascular disease. Currently, treatment strategies for AS still focus on lowering lipid levels with high-intensity statins, which often cause significant side effects. Therefore, the development of safer and more effective drugs and treatment modes is the focus of current research. Traditional Chinese medicine and natural compounds have the potential to treat AS by targeted autophagy, and have been playing an increasingly important role in the prevention and treatment of cardiovascular diseases in China. This paper summarizes the experimental studies on different vascular cell types and platelet autophagy in AS, and sums up the published research results on targeted autophagy of traditional Chinese medicine and natural plant compounds to regulate AS, providing new ideas for further research.
Humans
;
Endothelial Cells/metabolism*
;
Cardiovascular Diseases
;
Medicine, Chinese Traditional
;
Atherosclerosis/prevention & control*
;
Lipoproteins, LDL/metabolism*
;
Endothelium, Vascular
;
Plaque, Atherosclerotic
;
Autophagy

Result Analysis
Print
Save
E-mail