1.Magnetic resonance differential analysis for different hormone receptor expression status in HER-2-positive breast cancer.
Ziqin ZOU ; Yanfang HUANG ; Zhihui ZHOU ; Yu YANG
Journal of Central South University(Medical Sciences) 2023;48(1):68-75
OBJECTIVES:
Currently, it is difficult to assess the expression status of hormone receptor (HR) in breast malignant tumors with human epidermal growth factor receptor 2 (HER-2)-positive in the early preoperative stage, and it is difficult to predict whether it is non-invasively. This study aims to explore the value of MRI on the different HR expression status (HR+/HR-) in HER-2 positive breast cancer.
METHODS:
Thirty patients with HR+ HER-2-positive breast cancer (HR+ group) and 23 patients with HR-HER-2-positive breast cancer (HR- group) from the First Hospital of Hunan University of Traditional Chinese Medicine between January 7, 2015 and November 26, 2021 were selected as subjects, and all the patients were examined by MRI and all were confirmed by surgery or pathological biopsy puncture. The immunohistochemical staining results were used as the gold standard to analyze the basic clinical conditions, peri-lesion conditions and MRI sign characteristics in the 2 groups.
RESULTS:
There were all significant differences in terms of mass margins, internal reinforcement features, and apparent diffusion coefficient (ADC) values between the HR+ group and the HR- group (all P<0.05). The logistic multivariate regression model showed that: when the lesion presented as a mass-type breast cancer on MRI, the internal enhancement features of the lesion were an independent predictor for differentiation in the 2 types of breast cancer [odds ratio (OR)=5.95, 95% CI: 1.223 to 28.951, P<0.05], and the mass margin (OR=0.386, 95% CI: 0.137 to 1.082, P>0.05) and ADC value (OR=0.234, 95% CI: 0.001 to 105.293, P>0.05) were not the independent predictors in distinguishing the 2 types of breast cancer.
CONCLUSIONS
Multiparametric MRI has good diagnostic value for HR expression status in HER-2-positive breast cancer. Combined logistic regression analysis to construct a predictive model may be helpful to the identical diagnosis.
Humans
;
Female
;
Breast Neoplasms/surgery*
;
Magnetic Resonance Imaging/methods*
;
Diffusion Magnetic Resonance Imaging/methods*
;
Breast
;
Magnetic Resonance Spectroscopy
;
Retrospective Studies
2.Cardiac magnetic resonance-feature tracking technique can assess cardiac function and prognosis in patients with myocardial amyloidosis.
Jianing CUI ; Runxia LI ; Xueqian LIU ; Yanan ZHAO ; Xinghua ZHANG ; Qingbo LIU ; Tao LI
Journal of Southern Medical University 2023;43(4):660-666
OBJECTIVE:
To quantitatively assess cardiac functions in patients with cardiac amyloidosis (CA) and hypertrophic cardiomyopathy (HCM) using cardiac magnetic resonance-feature tracking (CMR-FT) technique and evaluate the prognostic value of CMR-FT in patients with CA.
METHODS:
We retrospectively collected the data from 31 CA patients with systemic amyloidosis confirmed by Congo red staining and serum immunohistochemistry after extracardiac tissue biopsy undergoing CMR at our hospital from March, 2013 to June, 2021.Thirty-one age and gender matched patients with asymmetric left ventricular wall hypertrophy and 31 healthy individuals without organic or functional heart disease served as the controls.Radial, circumferential and longitudinal strains and strain rates of the left ventricle at the global level and in each myocardial segment (basal, middle and apical) were obtained with CMR-FT technique and compared among the 3 groups.The predictive value of myocardial strains and strain rates for all-cause mortality in CA patients was analyzed using a stepwise COX regression model.
RESULTS:
The left ventricular volume, myocardial mass, ejection fraction and cardiac output differed significantly among the groups (P < 0.05).Except for apical longitudinal strain, the global and segmental strains were all significantly lower in CA group than in HCM group (P < 0.05).The global and segmental strains were all significantly lower in CA group than in the healthy individuals (P < 0.05).The basal strain rates in the 3 directions were significantly lower in CA group than in the healthy individuals (P < 0.05), but the difference in apical strain rates was not statistically significant between the two groups.Multivariate stepwise COX analysis showed that troponin T (HR=1.05, 95%CI: 1.01-1.10, P=0.017) and middle peak diastolic circumferential strain rate (HR=6.87, 95%CI: 1.52-31.06, P=0.012) were strong predictors of death in CA patients.
CONCLUSION
Strain and strain rate parameters derived from CMR-FT based on cine sequences are new noninvasive imaging markers for assessing cardiac impairment in CA and cardiac function changes in HCM, and provide independent predictive information for all-cause mortality in CA patients.
Humans
;
Retrospective Studies
;
Magnetic Resonance Imaging, Cine/methods*
;
Cardiomyopathy, Hypertrophic/diagnostic imaging*
;
Ventricular Function, Left
;
Stroke Volume
;
Amyloidosis/diagnostic imaging*
;
Magnetic Resonance Spectroscopy
;
Prognosis
;
Predictive Value of Tests
3.Current applications for magnetic resonance-guided focused ultrasound in the treatment of Parkinson's disease.
Haoxuan LU ; Xiaoyu WANG ; Xin LOU
Chinese Medical Journal 2023;136(7):780-787
Magnetic resonance-guided focused ultrasound (MRgFUS) is a novel and minimally invasive technology. Since the US Food and Drug Administration approved unilateral ventral intermediate nucleus-MRgFUS for medication-refractory essential tremor in 2016, studies on new indications, such as Parkinson's disease (PD), psychiatric diseases, and brain tumors, have been on the rise, and MRgFUS has become a promising method to treat such neurological diseases. Currently, as the second most common degenerative disease, PD is a research hotspot in the field of MRgFUS. The actions of MRgFUS on the brain range from thermoablation, blood-brain barrier (BBB) opening, to neuromodulation. Intensity is a key determinant of ultrasound actions. Generally, high intensity can be used to precisely thermoablate brain targets, whereas low intensity can be used as molecular therapies to modulate neuronal activity and open the BBB in conjunction with injected microbubbles. Here, we aimed to summarize advances in the application of MRgFUS for the treatment of PD, with a focus on thermal ablation, BBB opening, and neuromodulation, in the hope of informing clinicians of current applications.
Humans
;
Parkinson Disease/therapy*
;
Brain
;
Blood-Brain Barrier
;
Essential Tremor/surgery*
;
Brain Neoplasms
;
Magnetic Resonance Imaging/methods*
;
Magnetic Resonance Spectroscopy
6.Research on a portable shielding-free ultra-low field magnetic resonance imaging system.
Yuxiang ZHANG ; Wei HE ; Lei YANG ; Yucheng HE ; Jiamin WU ; Zheng XU
Journal of Biomedical Engineering 2023;40(5):829-836
The portable light-weight magnetic resonance imaging system can be deployed in special occasions such as Intensive Care Unit (ICU) and ambulances, making it possible to implement bedside monitoring imaging systems, mobile stroke units and magnetic resonance platforms in remote areas. Compared with medium and high field imaging systems, ultra-low-field magnetic resonance imaging equipment utilizes light-weight permanent magnets, which are compact and easy to move. However, the image quality is highly susceptible to external electromagnetic interference without a shielded room and there are still many key technical problems in hardware design to be solved. In this paper, the system hardware design and environmental electromagnetic interference elimination algorithm were studied. Consequently, some research results were obtained and a prototype of portable shielding-free 50 mT magnetic resonance imaging system was built. The light-weight magnet and its uniformity, coil system and noise elimination algorithm and human brain imaging were verified. Finally, high-quality images of the healthy human brain were obtained. The results of this study would provide reference for the development and application of ultra-low-field magnetic resonance imaging technology.
Humans
;
Magnetic Resonance Imaging/methods*
;
Magnetic Resonance Spectroscopy/methods*
;
Head
;
Equipment Design
;
Magnets
7.Associations of Infarct Size and Regional Myocardial Function Examined by Cardiac Magnetic Resonance Feature Tracking Strain Analysis with the Infarct Location in Patients with Acute ST-Segment Elevation Myocardial Infarction.
Cui JIA-NING ; Zhao YA-NAN ; Wang WEI ; Li TAO
Chinese Medical Sciences Journal 2022;37(4):309-319
Objective To quantitatively evaluate the associations of infarct size, regional myocardial function examined by cardiac magnetic resonance feature tracking (CMR-FT) strain analysis with infarct location in patients with ST-segment elevation myocardial infarction (STEMI) treated by primary percutaneous coronary intervention.Methods Cardiac magnetic resonance images were retrospectively analyzed in 95 consecutive STEMI patients with successful reperfusion. The patients were divided into the anterior wall myocardial infarction (AWMI) and nonanterior wall myocardial infarction (NAWMI) groups. Infarct characteristics were assessed by late gadolinium enhancement. Global and regional strains and associated strain rates in the radial, circumferential and longitudinal directions were assessed by CMR-FT based on standard cine images. The associations of infarct size, regional myocardial function examined by CMR-FT strain analysis with infarct location in STEMI patients were evaluated by the Spearman or Pearsonmethod. Results There were 44 patients in the AWMI group and 51 in the NAWMI group. The extent of left ventricular enhanced mass was significantly larger in patients with AWMI compared with the NAWMI group (24.47±11.89, 21.06±12.08 %LV; t=3.928, P = 0.008). In infarct zone analysis, strains in the radial, circumferential and longitudinal directions were remarkably declined in the AWMI group compared with the NAWMI group (z=-20.873, -20.918, -10.357, all P < 0.001). The volume (end-systolic volume index), total enhanced mass and extent of enhanced mass of the left ventricular were correlated best with infarct zone strain in the AWMI group (all P < 0.001). Conclusion In STEMI patients treated by percutaneous coronary intervention, myocardial damage is more extensive and regional myocardial function in the infarct zone is lower in the AWMI group compared with the NAWMI group.
Humans
;
Anterior Wall Myocardial Infarction/therapy*
;
ST Elevation Myocardial Infarction/pathology*
;
Contrast Media
;
Retrospective Studies
;
Ventricular Function, Left
;
Magnetic Resonance Imaging, Cine/methods*
;
Gadolinium
;
Magnetic Resonance Imaging
;
Myocardial Infarction/diagnostic imaging*
;
Magnetic Resonance Spectroscopy
;
Percutaneous Coronary Intervention
;
Stroke Volume
8.Quality evaluation of ginsenoside reference substances based on qNMR spectroscopy.
Jian-Yang PAN ; Fang ZHAO ; Wen-Zhu LI ; Hai-Bin QU
China Journal of Chinese Materia Medica 2022;47(3):575-580
The present study established a quality evaluation method for ginsenoside reference substances based on quantitative nuclear magnetic resonance(qNMR) spectroscopy. ~1H-NMR spectra were collected on Bruker Avance Ⅲ 500 MHz NMR spectrometer equipped with a 5 mm BBO probe. The acquire parameters were set up as follows: pulse sequence of 30°, D_1=20 s, probe temperature= 303 K, and the scan number = 32. Dimethyl terephthalate, a high-quality ~1H-qNMR standard, was used as the internal standard and measured by the absolute quantitative method. Methyl peaks of comparatively good sensitivity were selected for quantification, and linear fitting deconvolution was adopted to improve the accuracy of integration results. The qNMR spectroscopy-based method was established and validated, which was then used for the quality evaluation of ginsenoside Rg_1, ginsenoside Re, ginsenoside Rb_1, ginsenoside Rd, and notoginsenoside R_1. The results suggested that the content of these ginsenoside reference standards obtained from the qNMR spectroscopy-based method was lower than that detected by the normalization method in HPLC provided by the manufacturers. In conclusion, the qNMR spectroscopy-based method can ensure the quality of ginsenoside reference substances and provide powerful support for the accurate quality evaluation of Chinese medicine and its preparations. The qNMR spectroscopy-based method is simple, rapid, and accurate, which can be developed for the quantitative assay of Chinese medicine standard references.
Chromatography, High Pressure Liquid/methods*
;
Ginsenosides/analysis*
;
Magnetic Resonance Spectroscopy/methods*
;
Proton Magnetic Resonance Spectroscopy
;
Reference Standards
9.Determination of absolute configuration of a new triterpenic acid in leaves of Ilex hainanensis.
Xin-Liang LI ; Sheng-Nan FU ; Shu-Wan TANG ; Li MA ; Jie SUN ; Cun-Yu LI ; Yun-Feng ZHENG ; Guo-Ping PENG
China Journal of Chinese Materia Medica 2022;47(15):4084-4088
This study aimed to explore the triterpenic acid components in leaves of Ilex hainanensis. Alkaline water extraction, macroporous resin adsorption, and high performance liquid chromatography were used to separate and purify the triterpenic acid components in leaves of I. hainanensis. The physical and chemical property analysis, MS, NMR spectroscopy, and literature comparison were performed to identify the structures, and a new triterpene acid compound was discovered:(3S, 4R, 5R, 8R, 9R, 10R, 14S, 17S, 18S, 19R)-3,19-dihydroxyursa-12,20(30)-diene-24,28-dioic-acid, and named ilexhainanin F. In addition, according to its structural characteristics, the ~(19)F-NMR Mosher method was further employed to study its absolute configuration. By comparison of the ~(19)F-NMR chemical shifts of Mosher esters, it was determined that the absolute configuration of the 3-position chiral center of the compound was the S configuration.
Chromatography, High Pressure Liquid/methods*
;
Ilex/chemistry*
;
Magnetic Resonance Spectroscopy
;
Molecular Structure
;
Plant Leaves/chemistry*
;
Triterpenes/analysis*
10.Toxicity comparison of raw and vinegar-processed Bupleuri Radix based on ~1H-NMR metabolomics.
Hui-Min SUN ; Ting ZHANG ; Zhen-Yu LI ; Xue-Mei QIN
China Journal of Chinese Materia Medica 2022;47(19):5224-5234
This study compared the toxicity of raw Bupleuri Radix(BR) and vinegar-processed Bupleuri Radix(VPBR) based on proton nuclear magnetic resonance(~1H-NMR), and explored the mechanism of toxicity. Thirty-two male Sprague-Dawley(SD) rats were randomly divided into four groups: a control group(distilled water), a raw BR group(15 g·kg~(-1)·d~(-1)), a rice VPBR(R-VPBR) group(15 g·kg~(-1)·d~(-1)), and a shanxi VPBR(S-VPBR) group(15 g·kg~(-1)·d~(-1)). After administration for 30 d, pathological sections were treated and observed, and biochemical indexes related to liver and renal function were determined. The serum, liver, and kidney of rats were collected and analyzed by ~1H-NMR. The principal component analysis(PCA) and orthogonal partial least squares-discrimination analysis(OPLS-DA) were performed. The results showed that, as compared with the control group, alanine aminotransferase(ALT), aspartate aminotransferase(AST), and alkaline phosphatase(ALP) in the raw BR group were increased significantly, while ALT and ALP in the R-VPBR and S-VPBR groups were significantly decreased(P<0.05), which indicated that BR showed certain hepatotoxicity, and vinegar processing reduced its hepatotoxicity. No significant difference of blood urea nitrogen(BUN) and creatinine(CREA), the biochemical indexes related to renal function, was observed in the control group and administration groups, indicating that BR had less effect on the renal function. The results of multivariate statistical analysis showed that the biomarkers of BR affecting liver metabolism were methionine, glutamine, and glutamic acid, and affecting kidney metabolism were taurine, ornithine, and inosine. These biomarkers were mainly involved in amino acid metabolism, energy metabolism, lipid metabolism, and taurine metabolism. VPBR alleviated the effect on the biomarkers, and S-VPBR had smaller effect than R-VPBR. Combining the results of biochemical indexes and metabolomics analysis, both raw BR and VPBR showed toxic effect on rats, whereas vinegar processing reduced its toxicity. S-VPBR has smaller effect on kidney and liver metabolism than R-VPBR, which indicates that the vinegar used for processing has certain effect on the toxicity of BR.
Male
;
Rats
;
Animals
;
Acetic Acid/chemistry*
;
Drugs, Chinese Herbal/chemistry*
;
Proton Magnetic Resonance Spectroscopy
;
Rats, Sprague-Dawley
;
Metabolomics/methods*
;
Liver
;
Chemical and Drug Induced Liver Injury/pathology*
;
Taurine/pharmacology*

Result Analysis
Print
Save
E-mail