1.Evaluation of the application effectiveness and optimization strategies of confidential unit exclusion in Zhengzhou
Dan LIU ; Hongwei MA ; Tao WEN ; Yonglei LYU ; Mengru JI ; Ge SONG ; Huanyu LIU ; Mengdi FAN
Chinese Journal of Blood Transfusion 2026;39(3):379-383
Objective: To evaluate the practical effectiveness of confidential unit exclusion (CUE) in ensuring blood safety in Zhengzhou, analyze its application characteristics and existing problems, and provide a basis for optimizing blood safety management strategies. Methods: A retrospective analysis was conducted on CUE data handled by Henan Red Cross Blood Center from January 2019 to December 2024. Parameters such as the number of cases, demographic characteristics, reasons for exclusion, and time of report were statistically analyzed and compared with those of non-CUE. Results: From 2019 to 2024, the CUE reporting rate in Zhengzhou was 0.002 6% (40/1 547 666). CUE donors were predominantly male (65.00%, 26/40), aged 18-34 years (47.50%, 19/40), had college degree orabove (50.00%, 20/40), and were employees of enterprises or public institutions (32.50%, 13/40). Among the 40 CUE blood units, only one was reactive for anti-TP, while all others were qualified. The main reasons for CUE were recent vaccination (32.50%, 13/40), medical conditions unsuitable for donation (27.50%, 11/40), and high-risk sexual behavior (17.50%, 7/40). A total of 70.00% of reports occurred within 24 hours after donation, during which none of the corresponding blood units had been released; all units reported after more than 7 days had already been issued for clinical use, with no adverse transfusion reactions reported upon follow-up. Conclusion: The confidential unit exclusion program has played an active role in establishing a supplementary information feedback channel for blood donors. The procedure can be optimized by strengthening interactive communication and confirmation before donation, improving the accuracy of donors' self-assessment, and expanding convenient and rapid information-based reporting channels.
2.Intelligent blood logistics reinvention: HFMEA-applied transport pathway optimization for biopharmaceutical safety assurance
Qiming YING ; Fangfang JIN ; Fengmin XU ; Jiaji HU ; Danni SONG ; Bin WU ; Qinhong XU ; Dingfeng LYU
Chinese Journal of Blood Transfusion 2026;39(1):123-127
Objective: To explore the application effectiveness of healthcare failure mode and effect analysis (HFMEA) in optimizing intelligent blood logistics transport pathways for safety assurance. Methods: Data from 1 851 cases of intelligent blood logistics transport were collected between September 2023 and March 2025. Based on the implementation phases of HFMEA measures, the cases were divided into a control group (n=120), observation group 1 (n=219), and observation group 2 (n=1 512). Through systematic analysis of the transport processes, hazard scoring and decision tree analysis were conducted for each process, and phased optimization measures were implemented for high-risk failure modes. Results: The transport duration of intelligent blood logistics was 35.5 (20.8, 71.1) min in the control group, 25.1 (10.9, 40.7) min in observation group 1, and 9.9 (4.2, 44.5) min in observation group 2. Observation group 2 exhibited significantly shorter transport time compared to both observation group 1 and the control group, with statistically significant differences between groups (P<0.000 1). Conclusion: The implementation of HFMEA-driven measures significantly reduced intelligent blood logistics transport duration, thereby fostering the evolution of smart hospital ecosystems while enhancing healthcare service quality and operational efficiency.
3.Effect of measurement site on diagnostic performance of CT-derived fractional flow reserve
Yutao ZHOU ; Na ZHAO ; Yunqiang AN ; Lei SONG ; Chaowei MU ; Jingang CUI ; Tao JIANG ; Li XU ; Hongjie HU ; Lin LI ; Dumin LI ; Wenqiang CHEN ; Lijuan FAN ; Feng ZHANG ; Yang GAO ; Bin LYU
Chinese Journal of Radiology 2025;59(6):704-711
Objective:To investigate the effect of CT-derived fractional flow reserve (CT-FFR) measurement sites on the values and the diagnostic performance, and to determine the optimal measurement site for CT-FFR using invasive FFR as the reference standard.Methods:This study was part of the CT-FFR CHINA clinical trial. Patients with suspected coronary artery disease who were scheduled for invasive coronary angiography (ICA) were prospectively recruited from five clinical centers across the country from November 2018 to March 2020. Each enrolled patient underwent coronary CT angiography (CCTA), CT-FFR, ICA, and invasive pressure wire-based FFR assessments sequentially within one week. Four groups of CT-FFR values were obtained on each enrolled target vessels according to different CT-FFR measurement locations: 1, 2, 3 cm distal to the target lesion, and terminal vessel groups. Spearman and Bland-Altman analyses were used to explore the correlation and consistency of CT-FFR values and FFR values at different measurement sites. The measurement deviation of CT-FFR was also compared. Diagnostic accuracy and performance of CT-FFR, including sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve (AUC), in discriminating myocardial ischemia were analyzed across all measurement site groups on a per-vessel level, using FFR as the reference standard.Results:A total of 289 patients with 345 target lesion vessels were included. According to CCTA, there were 51 target vessels (14.8%) with<50% stenosis, 106 vessels (30.7%) with 50%-69% stenosis, and 188 vessels (54.5%) with stenosis≥70%. At per-vessel level, CT-FFR and FFR values at each measurement position group were highly positively correlated: 1 cm distal to target lesion group, r=0.734 ( P<0.001); 2 cm distal to target lesion group, r=0.732 ( P<0.001); 3 cm distal to target lesion group, r=0.737 ( P<0.001); terminal vessel group was 0.719 ( P<0.001). At per-vessel level, CT-FFR and FFR values of all measurement sites were in good agreement (Bland-Altman analysis results): 1 cm distal to target lesion group, 0.014 (95% LoA 0.002-0.026); 2 cm distal to target lesion group, 0.026 (95% LoA 0.015-0.038); 3 cm distal to target lesion group, 0.040 (95% LoA 0.039-0.051); terminal vessel group, 0.075 (95% LoA 0.064-0.087). And at per-vessel level, the accuracy of diagnosing myocardial ischemia with CT-FFR at 1 cm was highest [84.6% (95% CI 80.4%-88.3%)], and the lowest accuracy in the terminal vessel group [67.0% (95% CI 61.7%-72.0%)]. However, there was no significant difference in the diagnostic accuracy of CT-FFR at 1 cm, 2 cm [80.6% (95% CI 76.1%-84.6%)] and 3 cm [77.5% (95% CI 72.6%-81.7%)]. AUC of CT-FFR at 1 cm distal to the lesion were both highest for global level and moderately stenosis (50%-69%) lesions [0.85 (95% CI 0.81-0.89), 0.84 (95% CI 0.77-0.90)]. And the differences were statistically significant among the four measurement location groups (all P<0.05). Conclusions:The deviation of CT-FFR increases with measurement site distance distal to target lesions. One centimeter distal to the target lesion is the optimal measurement site, and the CT-FFR value here shows the highest diagnostic performance for myocardial ischemic lesions, especially for moderate stenosis.
4.Application of ultrasound-guided liver puncture biopsy followed by coaxial biopsy needle tract radiofrequency ablation in patients with hepatocellular carcinoma at risk of bleeding
Sitong WU ; Hao CHENG ; Siyuan FAN ; Yong XIE ; Zechuan LIU ; Tianshi LYU ; Li SONG ; Xiaoqiang TONG ; Yinghua ZOU ; Hong ZHAO ; Jian WANG
Chinese Journal of Hepatobiliary Surgery 2025;31(7):515-518
Objective:To analyse the effect of ultrasound-guided percutaneous liver biopsy and the coaxial biopsy needle tract radiofrequency ablation on patients diagnosed with hepatocellular carcinoma who are considered to be at risk of bleeding.Methods:The data of 117 patients with hepatocellular carcinoma who underwent coaxial biopsy needle tract radiofrequency ablation after ultrasound-guided percutaneous liver biopsy in Peking University First Hospital from March 2019 to April 2023 were retrospectively analysed. There were 95 males and 22 females, with the age of (62.0±11.8) years. A comprehensive analysis was conducted on the following variables: the pre-puncture platelet count, the international standardised ratio, anticoagulation therapy, the haemoglobin (Hb) level, the success rate of the liver puncture, the qualified rate of liver puncture specimens, the number of puncture samples, the length of hospital stay, the Hb level after puncture, bleeding within 10 days post-operation, and complications after ablation, including biliary fistula, hemothorax and organ perforation.Results:Among the 117 patients, 60 cases (51.3%) had an international normalized ratio >1.1, 40 cases (34.2%) had thrombocytopenia, that is, <150×10 9/L, and 17 cases (14.5%) received continuous anticoagulation therapy before the operation. It is evident that all 117 patients successfully completed the ultrasound-guided percutaneous liver biopsy, and that all liver biopsy specimens were qualified. The absence of biliary fistula, hemothorax, organ perforation or death in the patients post-ablation was noted. According to the adverse event evaluation criteria, version 5.0, 113 cases (96.6%) were classified as grade 1 and 4 cases (3.4%) were classified as grade 3. The Hb concentration of patients with minor bleeding (grade 1) prior to puncture was (119.7±22.2) g/L, which was significantly higher than the Hb concentration of patients with severe bleeding (grade 3), (76.0±10.4) g/L ( t=3.92, P=0.010). A meticulous examination of the data revealed that there were no statistically significant differences between the two groups with regard to pre-puncture platelet count, pre-puncture international standardised ratio, pre-puncture proportion of receiving anticoagulant drugs, length of hospital stay and number of puncture samples (all P>0.05). Conclusion:For patients with hepatocellular carcinoma who are at risk of bleeding, ultrasound-guided percutaneous liver biopsy followed by coaxial biopsy needle tract radiofrequency ablation can obtain satisfactory liver tissue samples and is relatively safe. There were differences in hemoglobin levels before puncture among patients with different bleeding after puncture.
5.Efficacy and safety of tegoprazan (LXI-15028) vs. esomeprazole in patients with erosive esophagitis: A multicenter, randomized, doubleblind, non-inferiority phase Ⅲ trial
Huiyun ZHU ; Qian XUE ; Yingxiao SONG ; Zhenyu ZHANG ; Xing LI ; Shengxiang LYU ; Qiang ZHAN ; Fei LIU ; Lungen LU ; Liang ZHONG ; Weixing CHEN ; Dong SHAO ; Yanbing DING ; Deliang LIU ; Xiaozhong YANG ; Zhiming HUANG ; Zhaoshen LI ; Yiqi DU
Chinese Medical Journal 2025;138(19):2464-2471
Background::An evidence gap still exists regarding the efficacy and safety of tegoprazan in patients with erosive esophagitis (EE) in China. This study aimed to verify the efficacy and safety of tegoprazan vs. esomeprazole in patients with EE in China. Methods::This study was a multicenter, randomized, double-blind, parallel, active-controlled, non-inferiority phase III trial of patients with EE randomized 1:1 to tegoprazan 50 mg/day vs. esomeprazole 40 mg/day. This study was conducted in 32 sites between October 24, 2018 and October 18, 2019. The primary endpoint was the cumulative endoscopic healing rate at week 8. The secondary endpoint included endoscopic healing rate at week 4, changes in the reflux disease questionnaire (RDQ) and gastroesophageal reflux disease health-related quality of life (GERD-HRQL) scores, and symptom improvement. Results::A total of 261 patients were randomized: 132 to the tegoprazan group and 129 to the esomeprazole group. The cumulative endoscopic healing rate at 8 weeks in the tegoprazan group was non-inferior to that of the esomeprazole group (91.1% vs. 92.8%, difference: -1.7%, 95% confidence interval [CI]: -8.5%, 5.0%, P = 0.008). There were no statistically significant differences in the changes in RDQ (total, severity, and frequency) and GERD-HRQL scores between the two groups (all P >0.05). The percentages of days without symptoms, including daytime and nighttime symptoms based on patients' diaries, were similar between the two groups (all P >0.05). In the tegoprazan and esomeprazole groups, 71.5% (93/130) and 61.7% (79/128) of the participants reported adverse events (AEs), 2.3% and 0 experienced serious AEs, while 70.0% and 60.2% had treatment-emergent AEs, respectively. Conclusion::Tegoprazan 50 mg/day demonstrated non-inferior efficacy in healing EE, symptom improvement, and quality of life, and it has similar tolerability compared with esomeprazole 40 mg/day.
6.Comparison analyses of global burden of colorectal cancer
Jingjing LI ; Yunmeng ZHANG ; Yuting JI ; Jie WU ; Qianyun JIN ; Zhuowei FENG ; Hongyuan DUAN ; Xiaomin LIU ; Zhangyan LYU ; Fengju SONG ; Yubei HUANG
Chinese Journal of Oncology 2025;47(4):308-315
Objective:To analyze the incidence, mortality, survival patterns, and distribution characteristics of modifiable risk factors for colorectal cancer in selected global regions.Methods:Secondary analysis was conducted using data from the GLOBOCAN database and previous literature. We described the number of cases and age-standardized rates (ASRs) of incidence and mortality for colorectal cancer in China, the United States, the United Kingdom, and globally in 2022 and 2020, with gender-stratified analysis. ASRs were calculated using Segi's world standard population. Temporal trends in 5-year net survival rates were compared across three periods (2000-2004, 2005-2009, 2010-2014) among countries. Regional distribution differences in colorectal cancer deaths attributable to modifiable risk factors by gender were assessed in China.Results:In 2022, global colorectal cancer incidence and mortality were estimated at 1.926 million new cases and 904 000 deaths. China accounted for 27% of both global incidence (517 000 cases) and mortality (240 000 deaths). China's age-standardized incidence rate (20.1 per 100 000) was lower than those of the United States (27.0 per 100 000) and the UK (30.9 per 100 000). However, China's mortality rate (8.6 per 100 000) exceeded that of the US (7.9 per 100 000) but was lower than the UK (11.8 per 100 000). Compared to 2020, China demonstrated significant mortality reductions in 2022: males declined from 14.8 to 10.9 per 100 000, females from 9.4 to 6.5 per 100 000. Five-year net survival rates in China improved across periods for colon cancer (51.4%, 55.6%, 57.6%) and rectal cancer (49.5%, 52.5%, 56.9%), yet remained consistently lower than US and UK rates. Modifiable risk factors contributed to 45.1% of male and 41.4% of female colorectal cancer deaths in China, with marked regional disparities.Conclusions:China exhibits higher colorectal cancer incidence and mortality than global averages, with survival gaps persisting compared to developed nations. Regionally tailored comprehensive prevention strategies are essential to reduce disease burden through risk factor modification and optimized clinical management.
7.Expert consensus on combined screening for common cancers(2025 edition)
Kexin CHEN ; Wanqing CHEN ; Yubei HUANG ; Zhangyan LYU ; Fangfang SONG ; Changfa XIA ; Yongjie XU ; Lei YANG ; Chao SHENG ; Yacong ZHANG ; Peng WANG ; Yunmeng ZHANG ; Yuting JI ; Jingjing LI ; Wenxuan LI ; Jie WU ; Qianyun JIN ; Fengju SONG
Chinese Journal of Oncology 2025;47(7):533-557
Malignant tumors (commonly referred to as cancer) represent a major global public health challenge and contribute significantly to the worldwide disease burden. Early screening plays a critical role in improving detection rates, enabling timely intervention, and enhancing patient survival rates. However, current cancer screening guidelines primarily focus on site-specific screening, which may not fully address the need for comprehensive early detection. A scientifically rational, multi-cancer screening approach offers several advantages: it optimizes the use of biological samples, reduces time costs for participants, enhances the efficiency and comprehensiveness of screening, and minimizes overall expenses. Such an approach also facilitates the rational allocation of healthcare resources, ultimately helping to reduce the societal burden of cancer. To address this need, the Cancer Epidemiology Committee of the Chinese Anti-Cancer Association has developed the Expert Consensus on Combined Screening for Common Cancers in China. This consensus integrates multidisciplinary expertise and synthesizes the latest domestic and international researches on cancer screening, early detection, and treatment for prevalent malignancies. Drawing upon China's unique demographic and healthcare context, as well as practical screening experiences, the consensus provides evidence-based recommendations on target populations, screening technologies, and procedural workflows for multi-cancer screening. These guidelines align with the principles and methodologies established by the World Health Organization (WHO), aiming to enhance the effectiveness of combined cancer screening in China, improve early detection rates, and provide a scientific foundation for national cancer prevention and control strategies.
8.Development of transparent manikin and its application to surgical training on medical train
Ya-jun SONG ; Wen-gang HU ; Ming-hui YANG ; Sheng-qing LYU ; Chi-bing HUANG ; Ji-feng ZOU ; Yang LI ; Yun WANG ; Ji ZHENG
Chinese Medical Equipment Journal 2025;46(6):111-115
Objective To develop a novel type of transparent simulation manikin as a surgical training model to meet the surgical treatment demand on the medical train.Methods A transparent manikin was developed with the steps of basic data collection,motherboard design and manufacture and module production and assembly.Firstly,basic data collection was carried out with reference to standardized human anatomy and parameters.Secondly,some software such as UG NX7.5 was used to construct the motherboard of the manikin.Finally,module production and assembly were performed with the materials of acrylic,transparent rubber,silicone and hydrogel and the technology of silicone infusion.Results The transparent manikin developed had its anatomy structure close to that of the real body and high visuality for its internal and external components,which simulated a variety of war wounds and thus could be integrated with the surgical training scenarios on the medical train effectively.Conclusion The transparent manikin developed is characterized by high visuality,modularity and blood flow,and meets the demands for surgical training on the medical train.[Chinese Medical Equipment Journal,2025,46(6):111-115]
9.Value of RFID technology in the transfusion of uncrossmatched red blood cell during trauma emergency care
Qiming YING ; Danni SONG ; Dingfeng LYU
Chinese Journal of Blood Transfusion 2025;38(10):1377-1381
Objective: To establish a radio frequency identification (RFID) technology-based emergency release process of uncrossmatched type O red blood cells for trauma patients, thereby providing a reference method for blood inventory management. Methods: The medical records of uncrossmatched type O red blood cell suspension released from Jan 2023 to Dec 2024 were retrospectively analyzed. The pre-implementation (2023, n=23) and post-implementation (2024, n=19) data of the RFID technology-based emergency uncrossmatched transfusion management method were compared to evaluate its effectiveness. Results: During the study period, 42 patients received a total of 92 units uncrossmatched type O red blood cell suspensions in emergency, with no case of hemolytic transfusion reactions reported. Traffic accidents were the primary cause of emergency uncrossmatched transfusion, accounting for 66.7% (28/42) of cases. The patients in observation group were significantly older than those in the control group (60.58y vs 48y, P<0.05), with a trend toward more critical trauma conditions (84.2% vs 56.5%, P=0.053). Among 29 critically injured patients, the blood release time in the observation group was significantly shorter than that in the control group (2 min vs 4 min, P<0.05). After excluding deceased patients, the observation group showed shorter hospitalization duration compared to the control group (18.5 d vs 35.58 d, P<0.05). Patients treated with a high red blood cell-to-plasma ratio demonstrated a significantly higher resuscitation success rate compared to those with a low ratio (64.3% vs 30%, P<0.05). Conclusion: The implementation of the RFID technology-based emergency uncrossmatched transfusion management method can significantly reduce the blood release time, shorten average hospitalization duration, improve treatment efficiency, and ensure transfusion safety for trauma emergency patients.
10.Simultaneous Determination of 50 Kinds of Steroid Hormones in Surface Water by Online Solid Phase Extraction Coupled with Ultra Performance Liquid Chromatography-Triple Quadrupole Mass Spectrometry
Fang-Xi XU ; He NIU ; Yu-Tao GE ; Guo-Hua ZHU ; Hang-Bin LYU ; Jin-Song LI ; Lang-Sha YI ; Jian-Jie FU ; Gui-Bin JIANG
Chinese Journal of Analytical Chemistry 2025;53(6):998-1009,中插22-中插41
A novel analytical method was developed in this study by combining online solid phase extraction with ultra performance liquid chromatography-tandem mass spectrometry(Online SPE-UPLC-MS/MS)for simultaneous determination of 50 kinds of steroid hormones in surface water.Specifically,after high-speed centrifugation of 4 mL water samples,the supernatant was directly injected into an Oasis HLB online SPE column for enrichment and purification.Subsequently,the target compounds were transferred to the analytical column via valve switching for separation and analysis.The chromatographic separation was performed on a Thermo Acclaim RSLC C18 column(100 mm×2.1 mm,2.2 μm),using a mobile phase composed of 5 mmol/L ammonium fluoride aqueous solution and acetonitrile.Mass spectrometric detection was conducted in positive ion mode,utilizing multiple reaction monitoring(MRM)with quantification achieved by the internal standard method.The method validation demonstrated that the limits of detection(LOD)for the 50 kinds of steroid hormones ranged from 0.02 to 0.50 ng/L,while the limits of quantification(LOQ)were between 0.08 and 1.67 ng/L.The average recoveries in surface water samples at spiked concentrations of 5,20 and 200 ng/L were between 74.1%and 119%,with relative standard deviations(RSDs)of 0.2%to 9.9%.This method was applied to analyze 11 surface water samples collected from sites surrounding a pharmaceutical and chemical industrial park.A total of 44 kinds of steroid hormones were detected,with concentrations ranging from 0.11 to 88.6 ng/L,revealing the presence of hormone contamination in the environmental waters surrounding industrial areas.Compared with the traditional offline SPE methods,the proposed online SPE technique significantly reduced sample volume requirements and pretreatment time,while minimizing the loss of target compounds during the pretreatment process.Moreover,compared to reported online SPE techniques,this method achieved high-throughput analysis of multiple classes of steroid hormones,with lower detection limits and higher recoveries.Overall,this method provided rapid sample preparation,high sensitivity,and excellent stability,making it suitable for the direct analysis of trace steroid hormones in surface water.

Result Analysis
Print
Save
E-mail