1.Analysis on the clinical application effects and development of intelligent control system for airbag pressure of tracheal catheter
Guangchao YUAN ; Siyuan HA ; Fang WANG ; Weiyi ZHANG ; Wei XIA ; Junyan TAN ; Yijuan DING ; Luyan HUANG ; Min LEI
China Medical Equipment 2025;22(7):87-91
Objective:To analyze the research and development of control system for airbag pressure of intelligent tracheal catheter,and its application effect in clinical practice.Methods:The hospital designed an intelligent self-adaptive control system for cuff pressure of tracheal catheter,which can rationally apply main components such as single chip microcomputer,display screen,control panel,pressure monitoring module,inflation device and solenoid valve,etc..This control system connected the measuring module of pressure through single chip microcomputer,so as to continuously detect the airbag pressure of tracheal catheter.An inflation and deflation algorithm was independently researched and developed to control air pump or solenoid valve to inject or release part of the gas to the airbag,so as to achieve intelligent control for the pressure of airbag.Sixty patients underwent endotracheal intubation who admitted to the department of general surgery of Wuhan Hospital of Traditional Chinese Medicine from January 2022 to January 2023 were selected as the study objects,and they were divided into control group(n=30)and observation group(n=30)according to random number table method.The cuff pressure of endotracheal intubation of patients in control group were managed by conventional method.The intelligent adaptive control system was adopted to manage the cuff pressure of endotracheal intubation for patients in the observation group.The complications,compliance rate of airbag pressure,the instantaneous maximum value of airbag pressure during sputum aspiration,insertion of gastric tube,and turning over of body were compared between the two groups after intubation.Results:The incidence of complication included cough,trachyphonia,dysphagia and bloody sputum after tracheal intubation in the observation group were 6.66%,which was significantly lower than 33.33%in the control group,and the difference was statistically significant(x2=6.667,P<0.05).The compliance rate of the pressure(25-30cmH2O)of airbag in the control group was 92.83%,which was significantly lower than 97.78%in the observation group,and the difference was statistically significant(x2=14.698,P<0.05).The instantaneous maximum values of airbag pressure during sputum aspiration,insertion of gastric tube and turning over were(28.24±3.65)cmH2O,(27.98±4.25)cmH2O and(28.65±4.87)cmH2O in observation group,respectively,which were significantly lower than those in control group,and the differences were significant(t=17.930,19.208,16.485,P<0.05).Conclusion:The application of intelligent adaptive control system for cuff pressure of tracheal catheter can maintain the airbag pressure of tracheal catheter at normal level(20-30 cmH2O),and reduce complications,and improve the compliance rate of airbag pressure.
2.Current status analysis of anti-infection research by using the Bayesian method
Yiling LIU ; Jinglin LIU ; Zhenzhen LU ; Yingying WANG ; Qijing JIANG ; Bingzhe LI ; Luyan DAI ; Fanrong YAN ; Lihong HUANG
Chinese Journal of Pharmacoepidemiology 2025;34(1):69-77
Objective To analyze the application characteristics,trends,and special advantages of anti-infection research using the Bayesian method,and to provide methodological reference for the development of anti-infection research.Methods PubMed,CNKI and WanFang Data were electronically searched for the studies on anti-infection using Bayesian method published from January 1,2015 to November 21,2023.The relevant information of publication time,anti-infection type,sample size,Bayesian characteristics and Bayesian application pattern were analyzed descriptively and reviewed.Results A total of 86 studies were included,of which 41.9%were observational studies,only 7.0%were enterprise-initiated studies,and 48.8%were mentioning prior information studies.There was no domestic intervention study.The application characteristics and advantages of Bayesian method in intervention study,observational study and pharmacokinetic study are different.In intervention researches and observational researches,the application of Bayesian design decision and the application of Bayesian analysis and estimation accounts for 69.2%and 52.8%at most,respectively.Conclusions The Bayesian method is flexible,can be used for small sample sizes and complex model research,and can deal with uncertainty.In intervention studies in the field of anti-infection in China,the Bayesian method has not been applied widely.Only a handful of studies applying Bayesian method have been initiated by companies.In the future,it is still necessary to promote the advantages and application scenarios of Bayesian methods in the field of anti-infection research and strengthen the standardization of the application of Bayesian method.
3.Current status analysis of anti-infection research by using the Bayesian method
Yiling LIU ; Jinglin LIU ; Zhenzhen LU ; Yingying WANG ; Qijing JIANG ; Bingzhe LI ; Luyan DAI ; Fanrong YAN ; Lihong HUANG
Chinese Journal of Pharmacoepidemiology 2025;34(1):69-77
Objective To analyze the application characteristics,trends,and special advantages of anti-infection research using the Bayesian method,and to provide methodological reference for the development of anti-infection research.Methods PubMed,CNKI and WanFang Data were electronically searched for the studies on anti-infection using Bayesian method published from January 1,2015 to November 21,2023.The relevant information of publication time,anti-infection type,sample size,Bayesian characteristics and Bayesian application pattern were analyzed descriptively and reviewed.Results A total of 86 studies were included,of which 41.9%were observational studies,only 7.0%were enterprise-initiated studies,and 48.8%were mentioning prior information studies.There was no domestic intervention study.The application characteristics and advantages of Bayesian method in intervention study,observational study and pharmacokinetic study are different.In intervention researches and observational researches,the application of Bayesian design decision and the application of Bayesian analysis and estimation accounts for 69.2%and 52.8%at most,respectively.Conclusions The Bayesian method is flexible,can be used for small sample sizes and complex model research,and can deal with uncertainty.In intervention studies in the field of anti-infection in China,the Bayesian method has not been applied widely.Only a handful of studies applying Bayesian method have been initiated by companies.In the future,it is still necessary to promote the advantages and application scenarios of Bayesian methods in the field of anti-infection research and strengthen the standardization of the application of Bayesian method.
4.Analysis on the clinical application effects and development of intelligent control system for airbag pressure of tracheal catheter
Guangchao YUAN ; Siyuan HA ; Fang WANG ; Weiyi ZHANG ; Wei XIA ; Junyan TAN ; Yijuan DING ; Luyan HUANG ; Min LEI
China Medical Equipment 2025;22(7):87-91
Objective:To analyze the research and development of control system for airbag pressure of intelligent tracheal catheter,and its application effect in clinical practice.Methods:The hospital designed an intelligent self-adaptive control system for cuff pressure of tracheal catheter,which can rationally apply main components such as single chip microcomputer,display screen,control panel,pressure monitoring module,inflation device and solenoid valve,etc..This control system connected the measuring module of pressure through single chip microcomputer,so as to continuously detect the airbag pressure of tracheal catheter.An inflation and deflation algorithm was independently researched and developed to control air pump or solenoid valve to inject or release part of the gas to the airbag,so as to achieve intelligent control for the pressure of airbag.Sixty patients underwent endotracheal intubation who admitted to the department of general surgery of Wuhan Hospital of Traditional Chinese Medicine from January 2022 to January 2023 were selected as the study objects,and they were divided into control group(n=30)and observation group(n=30)according to random number table method.The cuff pressure of endotracheal intubation of patients in control group were managed by conventional method.The intelligent adaptive control system was adopted to manage the cuff pressure of endotracheal intubation for patients in the observation group.The complications,compliance rate of airbag pressure,the instantaneous maximum value of airbag pressure during sputum aspiration,insertion of gastric tube,and turning over of body were compared between the two groups after intubation.Results:The incidence of complication included cough,trachyphonia,dysphagia and bloody sputum after tracheal intubation in the observation group were 6.66%,which was significantly lower than 33.33%in the control group,and the difference was statistically significant(x2=6.667,P<0.05).The compliance rate of the pressure(25-30cmH2O)of airbag in the control group was 92.83%,which was significantly lower than 97.78%in the observation group,and the difference was statistically significant(x2=14.698,P<0.05).The instantaneous maximum values of airbag pressure during sputum aspiration,insertion of gastric tube and turning over were(28.24±3.65)cmH2O,(27.98±4.25)cmH2O and(28.65±4.87)cmH2O in observation group,respectively,which were significantly lower than those in control group,and the differences were significant(t=17.930,19.208,16.485,P<0.05).Conclusion:The application of intelligent adaptive control system for cuff pressure of tracheal catheter can maintain the airbag pressure of tracheal catheter at normal level(20-30 cmH2O),and reduce complications,and improve the compliance rate of airbag pressure.
5.Dopamine Control of REM Sleep and Cataplexy.
Chujun ZHANG ; Luyan HUANG ; Min XU
Neuroscience Bulletin 2022;38(12):1617-1619
6.Fluorescence spectra and test application study on the interaction of fluorescein and bovine serum albumin.
Xun HUANG ; Ai'ming SUN ; Xueqin DING ; Xiucheng XU ; Luyan FANG
Journal of Biomedical Engineering 2006;23(6):1325-1327
A fluorescence method is found for determination of bovine serum albumin (BSA). The method is based on the interaction of fluorescein with BSA to form a complex in Tris-HCl buffer of pH 2.2. The complex exitation wavelength is 467 nm, the emission wavelength is 515 nm. The linear measurement rang is between 1.8-500 mg/L for BSA, F = 26.776 C + 2.8082, r = 0.9999. This method is sensitive,steady,and low cost for determination of BSA.
Animals
;
Cattle
;
Drug Interactions
;
Fluorescein
;
chemistry
;
Serum Albumin, Bovine
;
analysis
;
Spectrometry, Fluorescence
;
methods

Result Analysis
Print