1.Effect of 3d-printed bolus installation on radiotherapy after radical mastectomy
Liu RUI ; Luo TAOHONG ; Cao ZONGBAO ; Ke XIAOLIN ; Ling RUI ; Li XUEWEN
Chinese Journal of Clinical Oncology 2025;52(3):140-143
Objective:By comparing the effects of installing 3d-printed bolus with or without positioning holes on the skin fit and patient dose distribution,the advantages and disadvantages of the two installation methods in the application of radiotherapy after radical breast cancer surgery were evaluated,and the reference was provided for clinical application.Methods:A total of 48 patients(34 patients with and 14 patients without positioning holes)who received radiotherapy for breast cancer in Suining Central Hospital from December 2022 to Au-gust 2024 were randomly selected.Three dimensional reconstruction of the air gap between the patient body surface and the 3d-printed bolus was conducted,and the tissue dose distribution of each case was analyzed.Comparative analysis was conducted using t-test to ana-lyze the differences of the skin fit and the key dosimetric indexes of target areas and organs at risk between the two bolus installation meth-ods.Results:The mean values of the maximum air gap height,air gap area and air gap volume of the group with positioning holes were lower than those of the group without positioning holes(P<0.05),and the skin fit showed better consistency.The target area conformity in-dex(CI),homogeneity index(HI),and affected lung radiation acceptance(V20,V5)of patients with positioning holes were better than those of patients without positioning holes(P<0.05).There was no significant difference in target area coverage of prescription dose,cardiac dose Dmean and spinal cord dose Dmax between two groups(P>0.05).Conclusions:The skin fit,dosimetric indexes of patient target area and or-gans at risk of 3d-printed bolus with positioning holes were superior to those without positioning holes,showing significant advantages in clinical applications.
2.Effect of 3d-printed bolus installation on radiotherapy after radical mastectomy
Liu RUI ; Luo TAOHONG ; Cao ZONGBAO ; Ke XIAOLIN ; Ling RUI ; Li XUEWEN
Chinese Journal of Clinical Oncology 2025;52(3):140-143
Objective:By comparing the effects of installing 3d-printed bolus with or without positioning holes on the skin fit and patient dose distribution,the advantages and disadvantages of the two installation methods in the application of radiotherapy after radical breast cancer surgery were evaluated,and the reference was provided for clinical application.Methods:A total of 48 patients(34 patients with and 14 patients without positioning holes)who received radiotherapy for breast cancer in Suining Central Hospital from December 2022 to Au-gust 2024 were randomly selected.Three dimensional reconstruction of the air gap between the patient body surface and the 3d-printed bolus was conducted,and the tissue dose distribution of each case was analyzed.Comparative analysis was conducted using t-test to ana-lyze the differences of the skin fit and the key dosimetric indexes of target areas and organs at risk between the two bolus installation meth-ods.Results:The mean values of the maximum air gap height,air gap area and air gap volume of the group with positioning holes were lower than those of the group without positioning holes(P<0.05),and the skin fit showed better consistency.The target area conformity in-dex(CI),homogeneity index(HI),and affected lung radiation acceptance(V20,V5)of patients with positioning holes were better than those of patients without positioning holes(P<0.05).There was no significant difference in target area coverage of prescription dose,cardiac dose Dmean and spinal cord dose Dmax between two groups(P>0.05).Conclusions:The skin fit,dosimetric indexes of patient target area and or-gans at risk of 3d-printed bolus with positioning holes were superior to those without positioning holes,showing significant advantages in clinical applications.
3.Isoflavones' effects on pharmacokinetic profiles of main iridoids from Gardeniae Fructus in rats
Ruirui CHANG ; Jialin LIU ; Yusha LUO ; Taohong HUANG ; Qiang LI ; Jun WEN ; Weidong CHEN ; Tingting ZHOU
Journal of Pharmaceutical Analysis 2020;10(6):571-580
Gardeniae Fructus (GF) and Semen Sojae Praeparatum (SSP) are both medicine food homologies and widely used in Chinese clinical prescriptions together. The research investigated the pharmacokinetics of four iridoids in normal rats and isolfavones-fed rats, which were administered with isolfavones from SSP for 7, 14, 21 and 28 consecutive days. A validated LC-MS/MS method was developed for determining shanzhiside, genipin-1-gentiobioside, geniposide and their metabolite genipin in rat plasma. Plasma samples were pretreated by solid-phase extraction using paeoniflorin as the internal standard. The chromatographic separation was performed on a Waters Atlantis T3 (4.6 mm × 150 mm, 3μm) column using a gradient mobile phase consisting of acetonitril and water (containing 0.06%acetic acid). The mass detection was under the multiple reaction monitoring (MRM) mode via polarity switching between negative and positive ionization modes. The calibration curves exhibited good linearity (r>0.997) for all components. The lower limit of quantitation was in the range of 1-10 ng/mL. The intra-day and inter-day precisions (RSD) at three different levels were both less than 12.2% and the accuracies (RE) ranged from -10.1% to 16.4%. The extraction recovery of them ranged from 53.8% to 99.7%. Pharmacokinetic results indicated the bioavailability of three iridoid glycosides and the metabolite, genipin in normal rats was higher than that in rats exposed to isoflavones. With the longer time of administration of iso-flavones, plasma concentrations of iridoids decreased, while genipin sulfate, the phase II metabolite of genposide and genipin-1-gentiobioside, appeared the rising exposure. The pharmacokinetic profiles of main iridoids from GF were altered by isoflavones.

Result Analysis
Print
Save
E-mail