1.Isochronous substitution effects of 24-hour movement behaviors on self-confidence level of junior high school students
XIONG Zhongjia, XIANG Wei, LI Jinkun, LU Changfen, LUO Xiaobing
Chinese Journal of School Health 2026;47(2):227-231
Objective:
To investigate the effects of 24 hour movement behaviors on the self confidence level of junior high school students, providing empirical evidence for optimizing physical activity intervention strategies and enhancing adolescents mental health.
Methods:
In December 2024, a stratified cluster random sampling method was used to select 350 students from 3 junior high schools in Wuhan City. The ActiGraph wGT3X-BT accelerometer was employed to monitor participants 24 hour movement behaviors, and the Children and Adolescents Self confidence Questionnaire was used to assess their self confidence levels. Compositional isotemporal substitution models were applied to analyze the substitution effects among different movement behaviors and their impact on the self confidence level of junior high school students.
Results:
Among the 24 hour movement behaviors of junior high school students, the compositional means and proportions of moderate to vigorous physical activity (MVPA), light physical activity (LPA), sedentary behavior (SB), and sleep (SP) were 33.91 min (2.35%), 151.64 min (10.53%), 761.12 min (52.86%), and 493.33 min (34.26%), respectively. There were no statistically significant differences were found across grade, parental education level, or family economic status ( t/F =0.62,1.50,-1.22, all P >0.05). Significant differences in self confidence levels were observed between male and female junior high students ( t=3.36, P <0.05). Regarding 24 hour movement behaviors, MVPA, LPA, SB and SP exhibited statistically significant differences across gender, grade, and parental education ( Z/H =-6.76-6.15, all P < 0.05 ). Results of component linear regression analysis indicated that the proportion of MVPA time positively predicted junior high school students self confidence levels ( β =4.38), while the proportion of SP time negatively predicted self confidence levels ( β = -11.20 ) (both P <0.05). Isotemporal substitution analysis revealed that replacing 15 minutes of SB and SP with MVPA increased total self confidence scores by 1.53 and 1.97 units, respectively, while the opposite substitution decreased scores by 2.48 and 2.91 units (all P <0.05). Dose response analysis revealed an asymmetric pattern in the isochronous substitution effects between MVPA and SB/SP.
Conclusions
The overall distribution of 24 hour movement behaviors significantly impacts self confidence level of junior high school students. Insufficient MVPA may constrain the positive development of self confidence.
2.Relationship of non-suicidal self-injury behavior with serum lipid levels and thyroid function among college students with depression
CHEN Lu, YANG Zhiqiang, CAO Xiaoping, ZHAO Yanxia, LIANG Shaoying, LUO Yi, LI Hongyu
Chinese Journal of School Health 2026;47(3):394-397
Objective:
To explore the relationship between non suicidal self injury (NSSI) behavior and serum lipid levels as well as thyroid function among college students with depression.
Methods:
A total of 169 college students with depression in the psychiatry departments of tertiary hospitals (grade 3A and 3B) in Ningbo from December 2023 to April 2025 were selected. The Adolescent Self injury Scale (ASIS) was used to assess the presence of NSSI, and participants were accordingly divided into a NSSI group ( n =51) and a non NSSI group ( n =118). General demographic data (including gender, age, and family situation) were collected from both groups. Blood tests were performed to measure lipid profiles [triglyceride (TG), total cholesterol (TC), high density lipoprotein cholesterol (HDL-C), low density lipoprotein cholesterol (LDL-C)] and thyroid hormones [triiodothyronine (T3), thyroxine (T4), free triiodothyronine (FT3), free thyroxine (FT4), thyroid stimulating hormone (TSH)]. Multivariate Logistic regression was employed to analyze risk factors for NSSI, and receiver operating characteristic (ROC) curve analysis was used to evaluate the predictive value of serum lipid and thyroid hormone levels for NSSI occurrence in college students with depression.
Results:
The levels of TC, LDL-C, and TSH in the NSSI group were (4.02±0.73) mmol/L, (2.32±0.36) mmol/L, and (6.57±1.95) mU/L , which were significantly higher than those in the non NSSI group [(3.41±0.56) mmol/L, (2.00±0.27) mmol/L, and ( 4.48± 1.09) mU/L, respectively] ( t =5.32, 5.60, 7.20, all P <0.05). Logistic regression analysis revealed that college students from single parent/reconstituted families, those who had experienced school bullying, and those with higher levels of TC, LDL-C, and TSH had a significantly increased risk of engaging in NSSI ( OR =5.22, 6.12, 5.90, 83.64, 3.64, all P <0.05). ROC curve analysis demonstrated that the combined detection of TC, LDL-C, and TSH had high diagnostic efficacy for predicting NSSI in college students with depression, with a sensitivity of 86.3% and a specificity of 94.9%.
Conclusions
NSSI behavior in college students with depression is associated with serum lipid levels and thyroid function. These biomarkers may serve as useful reference indicators for assessing the conditions of these patients.
3.Influencing factors for condom use among men who have sex with men
LIU Jing ; ZHU Han ; YIN Jue ; XIA Manman ; LU Yi ; DAI Qing ; GU Chengjie ; LUO Zhen
Journal of Preventive Medicine 2026;38(2):115-118
Objective:
To investigate the status of condom use and its influencing factors among men who have sex with men (MSM), so as to provide a basis for improving condom utilization rates and AIDS prevention and control in this population.
Methods:
From May to October 2024, a snowball sampling method was employed to recruit MSM in Songjiang District, Shanghai Municipality. Self-administered questionnaires were used to collect data on demographic characteristics, AIDS-related knowledge, sexual behaviors, pre-exposure prophylaxis (PrEP) and post-exposure prophylaxis (PEP), and condom use in the past six months. Multivariable logistic regression model was used to analyze the influencing factors for consistent condom use.
Results:
A total of 921 MSM were surveyed, with a median age of 29.00 (interquartile range, 9.00) years. Among them, 697 (75.68%) were aware of AIDS-related knowledge, 826 (89.69%) expressed willingness to use PrEP, and 835 (90.66%) were willing to use PEP. Additionally, 787 (85.45%) MSM reported their age at first homosexual intercourse as ≥18 years, while 519 (56.35%) reported consistent condom use in the past six months. Multivariable logistic regression analysis revealed that MSM who were aware of AIDS-related knowledge (OR=0.582, 95% CI: 0.423-0.801), willing to use PrEP (OR =0.611, 95% CI: 0.385-0.969), and whose age at first homosexual intercourse was <18 years (OR=0.480, 95% CI: 0.330-0.700) were less likely to consistent use condoms.
Conclusion
The proportion of consistent condom use among the MSM remains relatively low, which is primarily associated with AIDS-related knowledge, willingness to use PrEP, and the age at first homosexual intercourse.
4.Integrated evidence chain (Eff-iEC) based effectiveness evaluation of a multifunctional traditional Chinese medicine formula: Taking Xiaoyao San as an example
Caiping HE ; Ye LUO ; Zhiqi LI ; Haocheng YANG ; Lu LIU ; Yingjie XU ; Xiaoyan CHEN ; Siqi HUANG ; Jincai WEN ; Xiaoyan ZHAN ; Zhaofang BAI ; Xu ZHAO ; Xiaohe XIAO
Science of Traditional Chinese Medicine 2026;4(1):96-103
The study focuses on the concept of multifunctional traditional Chinese medicine (TCM) formulas and aims to evaluate the efficacy of the classical formula Xiaoyao San (逍遥散). Study employs the integrated evidence chain (Eff-iEC) method to organize, integrate, and evaluate its therapeutic efficacy in treating different diseases with the same therapy, and to investigate the feasibility of using Eff-iEC to evaluate the multifunctionality of TCM formulas. The evaluation covered Xiaoyao San's therapeutic effects on depression, premenstrual syndrome, chronic hepatitis, irritable bowel syndrome, dyspepsia, and menopausal syndrome. Concurrently, the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) system was used for evaluation, and authoritative medical documents were incorporated to corroborate the recognition of Xiaoyao San within the medical community. Depression and menopausal syndrome received higher ratings than other conditions in the Eff-iEC, GRADE, and Medical Community Recognition assessments. The Eff-iEC evidence grade for Xiaoyao San was rated as "High" or above for chronic hepatitis, irritable bowel syndrome, dyspepsia, and menopausal syndrome. Premenstrual syndrome received a "Moderate +" rating. The GRADE evidence level was "Low-〇〇⨁⨁" for depression, premenstrual syndrome, and chronic hepatitis; "Moderate-〇⨁⨁⨁" for dyspepsia and menopausal syndrome; and "Very Low-〇〇〇⨁" for irritable bowel syndrome. Depression and menopausal syndrome had the highest inclusion frequency, appearing in all 4 categories. Premenstrual syndrome, chronic hepatitis, and dyspepsia are not recommended in Western medical guidelines, but they are included in TCM guidelines, the China National Basic Medical Insurance Drug List, and the China National Essential Drug List. Irritable bowel syndrome appears only in the China National Basic Medical Insurance Drug List and China National Essential Drug List. The evaluation results obtained using the Eff-iEC method align with Medical Community Recognition, providing an objective and comprehensive assessment of Xiaoyao San's efficacy. The findings suggest that Xiaoyao San has strong evidence for treating depression and menopausal syndrome. However, further experimental and clinical trials are needed to assess its efficacy in treating premenstrual syndrome, chronic hepatitis, irritable bowel syndrome, and dyspepsia. These results support the clinical efficacy and rational use of Xiaoyao San, expand the application scope of the Eff-iEC method, and offer valuable insights and methodological references for the comparative evaluation of multifunctional TCM formulas.
5.TAZ WW Domain-Mediated Regulation of Gluconeogenesis and Tumorigenesis in Hepatocellular Carcinoma through Interaction with the Glucocorticoid Receptor
Hongxiang HUANG ; Jinhong CHEN ; Xingyu TAO ; Peiyuan ZHONG ; Yanqiu MENG ; Sujuan PENG ; Wanying LUO ; Zhiyong HE ; Shuai LUO ; Xie ZHU ; Zhihui LU ; Li CHEN ; Yangyang LIU
Endocrinology and Metabolism 2026;41(2):267-287
Background:
Hepatocellular carcinoma (HCC) is a leading cause of cancer mortality, characterized by poor prognosis due to its high proliferative and invasive potential. Tumor metabolic reprogramming, particularly involving glucose metabolism, is essential for tumor survival. This study investigates the role of the Hippo pathway effector transcriptional co-activator with PDZ-binding motif (TAZ) in regulating gluconeogenesis and promoting tumorigenesis in HCC.
Methods:
TAZ expression in HCC was analyzed using The Cancer Genome Atlas data and validated in clinical samples and cell lines. TAZ was overexpressed or silenced in HCC cell lines to evaluate its effects on cell proliferation, apoptosis, migration, and invasion. The expression and prognostic relevance of the gluconeogenesis-related genes phosphoenolpyruvate carboxykinase 1 (PCK1) and glucose-6-phosphatase (G6PC) were examined, along with their correlation with TAZ expression. Tumor growth was assessed in nude mice. Interactions between TAZ and the glucocorticoid receptor (GR) were investigated using co-immunoprecipitation, immunofluorescence, and chromatin immunoprecipitation assays.
Results:
TAZ was significantly upregulated in HCC tissues and cell lines. TAZ overexpression enhanced proliferation, reduced apoptosis, and promoted migration and invasion. In contrast, PCK1 and G6PC were downregulated in HCC and showed a negative correlation with TAZ expression.
Conclusion
TAZ modulates gluconeogenesis and accelerates tumor growth, whereas its knockdown attenuates tumor progression. TAZ interacts with GR, suppressing its transcriptional activity on gluconeogenic gene promoters.
6.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
7.Methodological Issues in the Design,Evaluation,and Reporting of Randomized Controlled Trials with "Pattern Dominating Disease"
Lu WANG ; Jiajia WANG ; Yingying ZHANG ; Xufei LUO ; Yaolong CHEN ; Jiansheng LI
Journal of Traditional Chinese Medicine 2026;67(14):1497-1502
This study explores methodological issues in the design, evaluation, and reporting of randomized controlled trials (RCTs) under the concept of "syndrome dominating disease". The discussion focuses on key aspects including the adaptability of trial design, the screening of research participants, the standardization of syndrome differentiation, the balance between intervention individualization and standardization, the integration of multi-dimensional outcome measures, and the limitations of existing evaluation and reporting tools when applied to this type of research, along with corresponding recommendations and future perspectives. Regarding research design, it is recommended to select or draw upon innovative design concepts such as basket trials and subgroup-based dynamic/static parallel-group designs, in order to innovate the design format of RCTs. Meanwhile, criteria for participant screening, TCM syndrome differentiation, and disease classification should be standardized. The balance should be appropriately achieved between intervention individualization and standardization, and a multidimensional assessment system encompassing TCM syndromes, disease-specific outcomes, and patient-reported outcomes should be established. For risk of bias assessment and research reporting, it is recommended,to develop specialized assessment and reporting tools based on existing instruments, in order to standardize the assessment and reporting of study findings. Future research may further explore the potential applications of artificial intelligence in the study design, risk-of-bias assessment, and reporting quality assessment of RCTs based on the "syndrome dominating disease" model, with a particular focus on methodological optimization, data integration, and enhancement of research quality.
8.Methodological Issues in the Design,Evaluation,and Reporting of Randomized Controlled Trials with "Pattern Dominating Disease"
Lu WANG ; Jiajia WANG ; Yingying ZHANG ; Xufei LUO ; Yaolong CHEN ; Jiansheng LI
Journal of Traditional Chinese Medicine 2026;67(14):1497-1502
This study explores methodological issues in the design, evaluation, and reporting of randomized controlled trials (RCTs) under the concept of "syndrome dominating disease". The discussion focuses on key aspects including the adaptability of trial design, the screening of research participants, the standardization of syndrome differentiation, the balance between intervention individualization and standardization, the integration of multi-dimensional outcome measures, and the limitations of existing evaluation and reporting tools when applied to this type of research, along with corresponding recommendations and future perspectives. Regarding research design, it is recommended to select or draw upon innovative design concepts such as basket trials and subgroup-based dynamic/static parallel-group designs, in order to innovate the design format of RCTs. Meanwhile, criteria for participant screening, TCM syndrome differentiation, and disease classification should be standardized. The balance should be appropriately achieved between intervention individualization and standardization, and a multidimensional assessment system encompassing TCM syndromes, disease-specific outcomes, and patient-reported outcomes should be established. For risk of bias assessment and research reporting, it is recommended,to develop specialized assessment and reporting tools based on existing instruments, in order to standardize the assessment and reporting of study findings. Future research may further explore the potential applications of artificial intelligence in the study design, risk-of-bias assessment, and reporting quality assessment of RCTs based on the "syndrome dominating disease" model, with a particular focus on methodological optimization, data integration, and enhancement of research quality.
9.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
10.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.


Result Analysis
Print
Save
E-mail