1.Preliminary study on an improved method for constructing internal quality control framework of ELISA
Youbin DUAN ; Rui WANG ; Le CHANG ; Changwen QIU ; Zhiqiang LI ; Gengrui CHEN ; Jingjuan YANG ; Qing HE ; Lunan WANG
Chinese Journal of Blood Transfusion 2026;39(1):103-108
Objective: To propose an improved method for constructing the internal quality control (IQC) framework for ELISA assays and validate its efficacy by statistically analyzing IQC data from nine blood center laboratories. Methods: 1) IQC data was collected from nine blood centers and analyzed using a domestic HBsAg ELISA detection kit as an example. 2) Differences between IQC values across batches within Blood Center 1 were assessed. 3) Statistical analyses were performed on batch usage, number of batches used, days of use, number of QC points, batch-specific means, and coefficients of variation (CV) across all nine centers. 4) Using the improved construction method for IQC framework, provisional and permanent frames were established for batches within Blood Center 1 and Blood Center 9, followed by outlier determination. Results: 1) Statistically significant differences were observed in IQC data between batches within Blood Center 1 (P<0.01). It is recommended that both the control material/reagents and the control chart framework be replaced simultaneously. 2) There were substantial differences among 9 blood centers regarding the control material/reagent lot numbers used, the number of QC runs per batch, and the QC values for identical lots. Therefore, individual laboratories should establish their own IQC chart frameworks. 3) The improved IQC framework construction method for ELISA assays is as follows: provisional frames are established via frame-shifting, using the pre-experimental mean and cumulative coefficient of variation (CV) from the preceding batch. For batches used >20 days with >20 QC points, permanent frames are constructed by aggregating in-control data accumulated over ≥20 days with ≥20 points to calculate cumulative mean and standard deviation. The provisional and permanent frames constructed by this method identified all 26 extreme outliers across Blood Centers 1 and 9 as out-of-control. Among the 218 general outliers, 10 were classified as normal by the provisional frames, while the remainder were designated as warnings or out-of-control. This method effectively monitors assay stability. Conclusion: Based on the statistical analysis of IQC practices across blood centers of varying scales, combined with the inherent characteristics of ELISA assays and the batch-to-batch instability of reagents/QC materials, it is recommended to reconstruct QC charts upon lot changes. The proposed method—utilizing frame-shifting for provisional frames and establishing permanent frames based on cumulative data—is applicable to blood center laboratories of differing sizes and effectively monitors the stability of the ELISA assay process.
2.Data analysis of resolution discrepancies in minipool nucleic acid testing: A 2024 national study of Chinese blood stations
Ying YAN ; Qing HE ; Wei ZHENG ; Jie MA ; Le CHANG ; Huimin JI ; Huizhen SUN ; Lunan WANG
Chinese Journal of Blood Transfusion 2026;39(4):423-429
Objective: To investigate the incidence, characteristics, and influencing factors of resolution discrepancies within the minipool (MP) testing model across Chinese blood station laboratories in 2024. Methods: A nationwide, multicenter, cross-sectional study was conducted, including 334 blood station laboratories that reported nucleic acid reactive data among enzyme immunoassay non-reactive samples. Of these, 296 laboratories adopted the pool resolution model, with a total of 12 536 273 samples tested. Systematic analysis was performed on resolution data, focusing on the MP-NAT reactivity rate, the pool resolution concordance rate, and the resolution discrepancy rate. Subgroup analyses were conducted based on reagent types, viral targets, and Ct values. Potential causes were further explored through laboratory surveys and re-examination of raw amplification curves. Results: In 2024, the national average MP-NAT reactivity rate was 0.15%. The overall pool resolution concordance rate was 57.86%, which showed a gradual decline as Ct values increased across all reagents. The national average resolution discrepancy rate was 0.081‱(102/12 536 273), with 17.91%(53/296) of laboratories reporting at least one discrepancy. Nine reagent types were associated with these events, exhibiting reagent-specific patterns. For Reagent A2, the predominant discrepancy was HBV reactive pools resolving as HIV (36.36%); for Reagent D1, HBV pools frequently resolved as HCV (38.89%); and for Reagent E, the most common pattern was HIV pools resolving as HBV (48.00%). These resolution discrepancies were strongly associated with high Ct values: the median pool Ct for HBV exceeded 38, while those for HCV and HIV both exceeded 40. Investigations across 16 laboratories revealed that most discrepant samples exhibited “tailing” amplification curves, with some cases linked to cross-contamination or reagent batch-specific issues. Conclusion: While the incidence of resolution discrepancies in the MP-NAT model remains low in China, variations exist across different reagents and laboratories. These discrepancies are closely associated with low viral load, reagent performance, and laboratory operational practices.
3.The management of blood donors tested reactive to HCV in blood screening based on confirmation of HCV infection
Xuelian DENG ; Liang ZANG ; Xiaofang GONG ; Lei ZHOU ; Xiaochun LIU ; Lin WANG ; Lunan WANG
Chinese Journal of Blood Transfusion 2026;39(4):444-451
Objective: To explore the management of blood donors tested reactive to HCV in blood screening based on confirmation of HCV infection. Methods: Multiple HCV antibody assays, repeating HCV RNA testing, follow-up of blood donors and retesting of archive samples were performed to confirm HCV infection, identify infection status, and exclude false positives in blood donors reactive to HCV in blood screening. Results: From 2011 to 2024, the unqualified rate of HCV detection in blood screening was 2.45‰(2 751/1 122 026). Among these, anti-HCV+-&NAT-accounted for 1.85‰, followed by anti-HCV++ at 0.60‰. The proportion of anti-HCV+-&NAT-and HCV RNA yields was extremely low (0.007‰). The positive rate of anti-HCV+-&NAT-samples tested by electrochemiluminescence method (ELCIA) was approximately 7.5%, differing among reagents (P<0.05). The follow-up of anti-HCV+-&NAT-donors showed that 96.2% (202/210) were false positives, but 51.4% of donors remained anti-HCV+-&NAT-during follow-up. Among them, 8 donors (3.8%) could not be ruled out from HCV infection due to positive retesting by ELCIA. Of the anti-HCV+-&NAT-donors who were reactive at the first follow-up, 86.8% remained anti-HCV+-&NAT-at the second follow-up. The sampling confirmation data showed that all of 260 anti-HCV++ donors were confirmed as anti-HCV positive, and the proportion of false positives or missed detections by NAT was very low. Two occult HBV infections (OBIs) and one HBsAg carrier were identified among the 3 anti-HCV +-&NAT+ donors, and no HCV infection was confirmed in 5 anti-HCV--&HCV RNA + donors. Conclusion: The prevalence of HCV among blood donors in Dalian was about 0.06%, with extremely low proportion of window-period infection and slightly higher proportion of resolved infections than that of current infections. The majority of anti-HCV+-&NAT-were false positive. Blood donors confirmed as false positive should be qualified in blood screening 3 months later before next donation. In order to reduce the false positive results, it was advisable to avoid the same type of supplementary reagents as the initial reagents when performing confirmation.
4.Evaluation of repeated testing with blood screening platform in confirmation of NAT non-discriminatory reactive samples
Mengfan LI ; Xuelian DENG ; Liang ZANG ; Lei ZHOU ; Xiaochun LIU ; Xiaohua LIANG ; Lunan WANG
Chinese Journal of Blood Transfusion 2026;39(4):458-464
Objective: To evaluate repeated testing on blood screening platforms in confirmation of non-discriminatory reactive (NDR) samples in nucleic acid testing (NAT). Methods: A total of 102 HBsAg-negative/NAT NDR samples were collected from voluntary blood donors at Dalian Blood Center between January 2021 and December 2023. Repeated testing was performed using two NAT platforms (Cobas s201 and Panther). For the first round of repeated testing, all samples were tested 12 times on each system; for the second round, the samples which were non-reactive or only reactive once in the first round were tested an additional 8 times. Anti-HBc and anti-HBs was detected using electrochemiluminescence assay (ECA). Meanwhile, blood donors were followed up. Results: The proportion of anti-HBc+ in 102 NDR samples was 88.2%. Forty-one samples (40.2%, 41/102) and 7 samples were confirmed HBV DNA+ in first-round and second-round repeated testing, respectively. The cumulative confirmation rate of HBV DNA+ was 47.1% (48/102) after repeated testing. Extra five blood donors detected HBV DNA+ in follow-up were identified as anti-HBc+ occult hepatitis B virus infection (OBI), while no window period infection was observed. Ultimately, there were 53 HBV infected donors confirmed, 46 HBV infection-unconfirmed, and 3 HBV uninfected. No significant difference was observed between the confirmation rate of the first-round testing and the cumulative confirmation rate after the second-round testing (P>0.05). The proportion of anti-HBc+ donors was quite high in both HBV infection-confirmed (98.1%) and unconfirmed group (82.6%), and donors with seronegative and anti-HBs-only occupied a high proportion in the latter (P<0.05). Conclusion: Numerous repeated testing of NDR samples using NAT platforms cannot achieve complete confirmation of HBV infection. Supplementary anti-HBc testing can minimize potential OBI risk among NDR donors, and is low-cost and efficient.
5.Research progress on imaging examinations of macular hole
Luxuan WANG ; Xiuhua LIU ; Lei GAO ; Lifeng LIU
International Eye Science 2026;26(1):63-66
Macular hole is an age-related disorder defined by a full-thickness defect of the foveal retina and a profound loss of central vision. First described in the mid-19th century, its study has now extended across more than 150 years. Breakthroughs in science and technology—especially the relentless refinement of retinal imaging platforms—have progressively refined our understanding of the disease. Optical coherence tomography(OCT)in particular has revolutionized characterization of the condition. At the same time, the widespread adoption of macular hole surgery has not only driven deeper investigations into pathogenesis and pre-operative assessment but also facilitated the global dissemination of surgical expertise and a marked rise in anatomical success. This review synthesizes the multimodal imaging hallmarks of macular holes and highlights the remaining clinical challenges in the application of OCT technology.
6.Analysis of the adjustment of current eligibility criteria for alanine aminotransferase levels in blood screening in China
Le CHANG ; Ying YAN ; Huimin JI ; Huizhen SUN ; Lunan WANG
Chinese Journal of Blood Transfusion 2025;38(4):465-473
[Objective] To obtain accurate data on alanine aminotransferase (ALT) levels among blood donors in China and to explore the necessity of adjusting the qualification criteria for ALT. [Methods] A collaborative study was conducted involving 26 blood centers and 7 central blood stations with an annual testing volume exceeding 100 000 samples. Between December 1 and 15, 2024, pre-donation ALT testing was suspended for 1-2 days for all whole blood donations. ALT levels were measured only post-donation using standard laboratory equipment and reagents. All transfusion-transmitted infectious disease-related serological and nucleic acid testing, including hepatitis E virus (HEV) RNA testing, were performed. Within one week of testing completion, anonymized data on basic donor information, routine test results, and HEV RNA results were collected and statistically analyzed. [Results] A total of 21 345 blood donors were included in the study, with an ALT disqualification rate of 7.6% (1 623/21 345). The disqualification rate was 9.6% (1 453/15 205) for males and 2.8% (170/6 140) for females. There were significant regional variations in both the disqualification rates and levels of ALT, with Shaanxi Province exhibiting the highest disqualification rate (12.3%, 87/710) and Yunnan Province the lowest (2.9%, 19/652). Among the provinces (autonomous regions and municipalities), Beijing recorded the lowest ALT levels. ALT levels varied across different age groups and genders. Among all samples tested by HEV RNA, the HEV RNA positive rate was 0.29‰ (6/21 003). HCV infection was found to directly affect ALT levels, while HBV, HIV, syphilis, and HEV infections did not significantly impact ALT disqualification rates. It is recommended to adjust the ALT qualification criteria to twice the upper limit of the clinical reference range, which would increase the number of eligible blood donations by 6.61% (1 293/19 550). [Conclusion] In China, the ALT levels of blood donors are correlated with gender, age, geographical region, and HCV infection status. Appropriately raising the ALT eligibility criteria to ≤100 U/L for male donors and ≤80 U/L for female donors could expand the pool of eligible donors and reduce the blood discard rate while ensuring blood safety.
7.Analysis of alanine aminotransferase screening results in blood donors and quality management measures
Liang ZANG ; Lei ZHOU ; Le CHANG ; Lunan WANG
Chinese Journal of Blood Transfusion 2025;38(4):474-481
[Objective] To explore quality issues and quality management measures in alanine aminotransferase (ALT) testing, aiming to improve consistency and accuracy of ALT test results by analyzing the outcomes from different pre-donation screening methods and different sample sources. [Methods] Data were collected from 58 blood collection and supply institutions across China. ALT test results from donor samples analyzed by dry chemistry analyzers, semi-automatic biochemical analyzers, and automatic biochemical analyzers were compared, focusing on the influence of venous versus capillary blood samples on testing accuracy. By comparing results from pre-donation screening with laboratory testing, the current state of quality management for different methods and sample types was assessed. Differences in ALT unqualified rates between laboratories were analyzed, and quality improvement strategies were proposed accordingly. [Results] No significant differences were found in laboratory ALT unqualified rates between venous and capillary blood samples during pre-donation screening across different analytical methods (P>0.05). However, laboratory ALT unqualified rates were consistently lower for venous blood compared to capillary blood, regardless of the testing method used (P<0.05). Notable differences in quality control were observed among various blood collection and supply institutions (P<0.05). [Conclusion] Minimal differences were observed between pre-donation ALT screening results obtained by the three analytical methods and laboratory test outcomes; thus, blood stations can select an appropriate testing method according to their specific conditions. Pre-donation screening using venous blood samples demonstrated superior reliability in quality control compared to capillary blood samples. Significant variations in ALT unqualified rates among blood stations suggest that blood collection and supply institutions should emphasize quality management at both the pre-donation screening and laboratory testing stages. Measures such as optimized standardized operating procedures, regular equipment calibration and maintenance, proficiency testing, internal quality control, inter-system comparisons, and enhanced personnel training and evaluation should be implemented to ensure consistent and stable screening results, thereby reducing ALT unqualified rates.
8.Application of SARIMA in predicting outbreaks of hospital-acquired infection in a tertiary psychiatric hospital
Mengwei ZHANG ; Hongwei WANG ; Mei GU ; Lunan XIAO
Chinese Journal of Nosocomiology 2025;35(16):2499-2503
OBJECTIVE To construct a Seasonal Autoregressive Integrated Moving Average(SARIMA)model based on the incidences of hospital-acquired infections(HAIs),and provide a reference for the prevention and control of HAI in such hospitals.METHODS The incidences of HAIs in a tertiary psychiatric hospital from Jan.2016 to Aug.2024 were collected by the Weining Hospital Infection Information Management software and paper-based HAI reporting cards.The incidence rates from 2016 to 2023 were analyzed and a SARIMA model was established.The incidence rates from Jan.to Aug.2024 were predicted,and the accuracy of the SARIMA model was evaluated based on the actual measured values.RESULTS From 2016 to 2023,a total of 98,075 patients were admitted,including 936 patients who developed HAIs,with an incidence rate of 0.95%ranged from 0.79%to 1.23%.The time series plot from 2016 to 2023 did not meet the requirements for sequence stability.After differ-entiating the original data,analyzing the correlation plot(ACF)and partial autocorrelation plot(PACF),and con-ducting multiple assessments and verifications,it was finally determined that SARIMA(1,1,1)(1,1,1)12,SA-RIM A(1,1,1)(1,1,0)12,ARIMA(1,1,1)(0,1,0)12,and SARIMA(1,1,1)(0,1,1)12 were the alterna-tive models.The Ljung-Box Q test was used to retain the models with P>0.05 that met the sequence with white noise and the minimum Bayesian Information Criterion(BIC)value was obtained,it was determined that SARIMA(1,1,1)(0,1,1)12 was the optimal model.When validated with Jan.to Aug.2024 HAI incidence data,the infection rates predicted by SARIMA(1,1,1)(0,1,1)12 model remained within the 95%confidence interval,indicating high prediction accuracy.CONCLUSION SARIMA model can effectively predict the monthly HAI incidences in a tertiary psychiatric hospital,and it plays an role in the decision-making of HAI prevention and control in psychiatric inpatients.
9.Evaluation of donor ALT screening strategies based on random sampling simulation with large sample sizes
Liqin HUANG ; Yuanye XUE ; Le CHANG ; Lunan WANG ; Jinfeng ZENG
Chinese Journal of Blood Transfusion 2025;38(8):1094-1100
Objective: To comprehensively evaluate the current alanine aminotransferase (ALT) screening strategies and provide a basis for their optimization. Methods: ALT test results of 21 345 blood samples were collected from 33 blood collection institutions. Multiple probability distribution functions were employed to fit the data, and the akaike information criterion (AIC) was used to determine the optimal fitting model. Based on this model, 1 million random samplings were conducted to simulate the final ALT test results of blood donors under different ALT screening strategies, eligibility criteria, and pre-donation ALT detection deviations. A decision tree was subsequently constructed for health economic analysis. Results: The log-normal distribution with a mean of 2.96 and a variance of 0.65 provided the best fit for the data. When the eligibility criteria was 50 U/L and the pre-donation detection deviation was ±20%, not conducting pre-donation testing increased blood donation by 1.14%. When the pre-donation detection deviation was ±20% and the eligibility criteria was raised from 50 U/L to 100 U/L, conducting and not conducting pre-donation testing increased blood donation by 7.59% and 6.60%, respectively. With a eligibility criteria of 50 U/L and a pre-donation detection deviation of ±20%, 1.14% of eligible blood donors would be disqualified from donating blood. Health economic analysis showed that when the eligibility criteria was adjusted to 56 U/L or higher, not conducting pre-donation ALT testing was the dominant strategy; under other conditions, conducting pre-donation testing was the dominant strategy. Conclusion: The selection of ALT testing strategies is a complex process influenced by multiple factors, and it is necessary to adopt an appropriate ALT screening strategy based on specific testing circumstances.
10.Effect of Xuebijing injection on tumor necrosis factor-α expression in rats with endotoxin-induced uveitis
Zhongxia DU ; Jie WANG ; Ruidong LI ; Yuan YANG
International Eye Science 2025;25(10):1560-1565
AIM: To evaluate the expression of tumor necrosis factor-α(TNF-α)in the iris and ciliary body of Wistar rats in the endotoxin-induced uveitis(EIU), and the effect of Xuebijing injection on its expression.METHODS:A total of 65 Wistar rats were randomly divided into three groups: Group A(normal saline, n=5), Group B(normal saline+endotoxin-injected, n=30), and Group C(Xuebijing+endotoxin-injected, n=30). The EIU model was induced in Wistar rats of the groups B and C by injecting LPS into the plantar surfaces of the hind feet, and normal saline(15 mL/kg)or Xuebijing(15 mL/kg)were intraperitoneally administered 30 min before LPS administration. The rats of the groups B and C were further divided into 6 subgroups after LPS injection, including 6, 12, 18, 24, 48, and 72 h subgroups, with 5 rats in each group. Furthermore, the intraocular inflammation of the rats was observed at each time above, the number of infiltrating cells in the aqueous humor was counted, and the pathological changes were observed in the iris and ciliary body of rats using hematoxylin and eosin(HE)staining. TNF-α expression in iris and ciliary tissue at different postoperative time points was evaluated using immunohistochemistry.RESULTS: Clinical observations indicated no signs of uveitis in the group A, signs of uveitis were observed in the group B. Both iris symptoms and damage were significantly reduced in the group C compared to the group B(P<0.01). Cell counts in the aqueous humor revealed no inflammatory cells in the group A, while the number of aqueous humor cells in the group C was significantly reduced compared to Group B(P<0.01). HE staining revealed no cellular infiltration in the group A. In the group B, some cellular infiltration was observed in the eyes at 6 h post-LPS exposure. The number of infiltrating cells increased over time, peaked at 24 h, and gradually declined thereafter. In the group C, cell infiltration was not obvious at 6 h, few at 24 h, and nearly disappeared by 48 h. Immunohistochemical staining showed higher TNF-α expression in the ciliary body and iris in the group B than in the group A(P<0.01). Compared to the group C, TNF-α expression in the group B was significantly upregulated following LPS injection(P<0.01).CONCLUSION:TNF-α expression was elevated in EIU rats, and there was a positive correlation between its mean optical density ratio and inflammation degree. Moreover, Xuebijing injection could alleviate inflammation response through the reduction of TNF-α levels.