1.Exploring Mechanism of Xiaojinwan-containing Serum in Inhibiting Breast Cancer Cells Based on Wnt/β-catenin Signaling Pathway
Hongdi TANG ; Xiaobo JIN ; Chen GAO ; Hongkai LI ; Zhiming LI ; Lu YAO ; Fengli SONG ; Ning KANG ; Wenwen WANG ; Ying SUN ; Zhibin WANG ; Tong LI ; Yingli ZHU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(17):13-22
ObjectiveTo investigate the role and underlying mechanism of the Wnt/β-catenin signaling pathway in the process of Xiaojinwan (XJW)-containing serum interfering with endothelial-mesenchymal transition (EMT) in human breast cancer MDA-MB-231 cells. MethodsXJW-containing serum was prepared by intragastric administration of XJW (4 g·kg-1) to SD rats. MDA-MB-231 cells were cultured in vitro. β-Catenin overexpression and knockdown plasmids were constructed and transfected into MDA-MB-231 cells. The optimal XJW-containing serum (4 g·kg-1) according to previous studies was used for β-catenin intervention and overexpression experiments. The groups for intervention/overexpression experiments included intervention/overexpression blank group, β-catenin intervention/overexpression group, intervention/overexpression blank + XJW group, and β-catenin intervention/overexpression + XJW group. Cell morphology was observed under a microscope. Flow cytometry was used to detect and record apoptosis rates. Western blot was performed to measure apoptosis-related proteins [B-cell lymphoma 2 (Bcl-2), Bcl-2-associated X protein (Bax), and active-Caspase-3] and EMT-related proteins (E-cadherin, N-cadherin, and vimentin). Real-time polymerase chain reaction (Real-time PCR) was used to detect β-catenin mRNA expression levels in different groups. ResultsIntervention experiment results showed that compared with the intervention blank group, the β-catenin intervention group and the intervention blank + XJW group showed increased apoptosis rates (P<0.05, P<0.01), elevated protein levels of Bax, active Caspase-3, and E-cadherin (P<0.05, P<0.01), and decreased protein levels of Bcl-2 and Vimentin (P<0.05, P<0.01). β-catenin mRNA expression was reduced in the β-catenin intervention group (P<0.05, 0.63 ± 0.15) and the intervention blank + XJW group (P<0.05, 0.79 ± 0.33). Compared with the β-catenin intervention group, the β-catenin intervention + XJW group exhibited an increased apoptosis rate (P<0.01), elevated Bax and active Caspase-3 protein levels (P<0.05, P<0.01), and decreased Bcl-2, N-cadherin, and Vimentin protein levels (P<0.05). β-catenin mRNA expression was further reduced in the β-catenin intervention + XJW group (P<0.01, 0.22 ± 0.08). Compared with the intervention blank + XJW group, the β-catenin intervention + XJW group showed an increased apoptosis rate (P<0.01), elevated Bax, active Caspase-3, and E-cadherin protein levels (P<0.05, P<0.01), and decreased Bcl-2, N-cadherin, and vimentin protein levels (P<0.05, P<0.01). β-catenin mRNA expression was also reduced (P<0.05). Overexpression experiment results showed that compared with the overexpression blank group, the β-catenin overexpression group exhibited a reduced apoptosis rate (P<0.01), while the overexpression blank + XJW group showed an increased apoptosis rate (P<0.05). In the β-catenin overexpression and β-catenin overexpression + XJW groups, Bax and E-cadherin protein levels decreased (P<0.05, P<0.01), while Bcl-2, N-cadherin, and vimentin levels increased (P<0.05). In the overexpression blank + XJW group, Bax and E-cadherin levels increased (P<0.05, P<0.01), while Bcl-2, N-cadherin, and vimentin levels decreased (P<0.05, P<0.01). β-catenin mRNA expression increased in the β-catenin overexpression group (P<0.01, 7.26 ± 1.03) but decreased in the overexpression blank + XJW group (P<0.05, 0.73 ± 0.14). Compared with the β-catenin overexpression group, the β-catenin overexpression + XJW group showed an increased apoptosis rate (P<0.01), elevated Bax and E-cadherin levels (P<0.05), and decreased N-cadherin and vimentin levels (P<0.05). β-catenin mRNA expression was reduced (P<0.05, 4.65 ± 1.02). Compared with the overexpression blank + XJW group, the β-catenin overexpression + XJW group exhibited a reduced apoptosis rate (P<0.01), decreased Bax and E-cadherin levels (P<0.01), and increased Bcl-2, N-cadherin, and Vimentin levels (P<0.05). β-catenin mRNA expression increased (P<0.01). ConclusionXJW-containing serum inhibits breast cancer cell proliferation by suppressing EMT, which is associated with the regulation of the Wnt/β-catenin pathway.
2.Spatiotemporal monitoring and ARIMA modeling of Blattella germanica populations in Nanjing, China (2017-2024)
Jian-jun XIA ; Pu-min ZHOU ; Yan ZHANG ; Bing-dong SONG ; Lu-yao SUN ; Shou-gang ZHANG
Acta Parasitologica et Medica Entomologica Sinica 2026;33(3):210-215
Objective Using cockroach surveillance data in Nanjing from 2017 to 2024, we have descriptively analyzed population characteristics and changes in insecticide resistance among Blattella germanica, and have established a seasonal Autoregressive Integrated Moving Average (ARIMA) model to predict monthly population densities in Nanjing spanning the year 2025. Methods B. germanica density and infestation rate were monitored using the sticky trap method, and insecticide resistance was assessed using the residual contact method. Our ARIMA model was applied to fit and estimate cockroach density fluctuations over time. Results From 2017 to 2024, B. germanica accounted for 94.90% of all cockroach specimens captured in Nanjing, with an average density of 0.37 cockroaches per trap and an average infestation rate of 5.56%. Significant differences in density and infestation rate were observed among different habitats (P<0.001). Significant downward annual trends in both density and infestation rate were found (P<0.05). ARIMA was found to be the optimal model for fitting the density data from 2017 to 2024 (0, 1, 1) × (0, 1, 1)1 2. Conclusions From 2017 to 2024, B. germanica was overwhelmingly the dominant cockroach species in Nanjing, with both its density and infestation rate declining annually. A positive correlation was observed between the amount and proportion of insecticide use and the development of insecticide resistance (P<0.05). The established model demonstrated good performance in predicting monthly B. germanica densities in Nanjing throughout 2025, providing a valuable reference for future surveillance and control efforts.
3.2023 China minimally invasive cardiovascular surgery statistics and future development thinking
Yao WANG ; Ye YANG ; Shuyang LU ; Zhe ZHENG ; Nianguo DONG ; Huiming GUO ; Song XUE ; Liming LIU ; Yingqiang GUO ; Xuezeng XU ; Lai WEI ; Chunsheng WANG
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(6):321-327
Objective:Committee of Minimally Invasive Cardiovascular Surgery(CMICS) conducts an annual summary of minimally invasive cardiovascular surgery procedures performed throughout the country, which includes a comprehensive survey of the total number of minimally invasive procedures by region and the distribution of minimally invasive procedures by hospital. Since CMICS first published the 2018-2019 China Minimally Invasive Cardiovascular Surgery Data White Paper in 2020, the report has received great attention from peers within and outside the industry. In this statistical report, CMICS will focus on publishing the data related to minimally invasive cardiovascular surgery in China from 2021 to 2023 for reference and use by industry peers.
4.Effect of silicate bioactive glass fiber on properties of calcium phosphate bone cement
Yuzheng LU ; Yingjie XIONG ; Yanbo SHAN ; Jianting YE ; Yanbin WU ; Jipeng SONG ; Yao ZHANG ; Wancheng LIN ; Qirui WENG ; Xuan CHENG ; Haoye MENG ; Wenjing XU ; Jiang PENG ; Lixiang DING
Chinese Journal of Tissue Engineering Research 2025;29(28):5994-6002
BACKGROUND:The development of calcium phosphate bone cement is limited due to its poor mechanical properties and weak osteogenic ability.Silicate bioactive glass is highly favored due to its excellent biological activity and osteogenic ability.Simultaneously,fiber structures can enhance the mechanical strength of materials.OBJECTIVE:To investigate the mechanical properties,biocompatibility,and osteogenic effect of silicate bioactive glass fiber composite calcium phosphate bone cement.METHODS:Different mass percentages(0%,10%,and 20%)of silicate bioactive glass fiber were added to the solid phase of calcium phosphate bone cement,mixed with the liquid phase and cured for 48 hours to obtain silicate bioactive glass fiber composite calcium phosphate bone cement.The mechanical properties,setting time,and ion precipitation of the cement were characterized.The three groups of bone cement extracts were co-cultured with MC3T3-E1 cells.The cell compatibility of the materials was evaluated by CCK-8 assay,live/dead staining,and phalloidin staining.After osteogenic induction,the osteogenic induction ability of the materials was evaluated by alkaline phosphatase staining,alizarin red staining,RUNX2 immunofluorescence staining,and RT-PCR.RESULTS AND CONCLUSION:(1)With the increase of silicate bioactive glass fiber content,the compressive strength and flexural strength of bone cement increased,and the setting time was prolonged.When bone cement was immersed in simulated body fluid,the precipitation of silicon ions,calcium ions,and phosphorus ions could be detected.Moreover,with the increase of silicate bioactive glass fiber content,the mass concentration of silicon ions and phosphorus ions released by bone cement increased,and the mass concentration of calcium ions decreased.(2)Live/dead staining and phalloidin staining results exhibited that silicate bioactive glass fiber composite calcium phosphate bone cement had no toxic effect on MC3T3-E1 cells.CCK-8 assay results showed that silicate bioactive glass fiber composite calcium phosphate bone cement could promote the proliferation of MC3T3-E1 cells.(3)With the increase of silicate bioactive glass fiber content in bone cement,the alkaline phosphatase activity and extracellular calcium deposition of MC3T3-E1 cells increased,the expression of RUNX2 protein increased,and the expression of alkaline phosphatase,osteocalcin,osteopontin,and RUNX2 mRNA expression increased.(4)The results indicate that silicate bioactive glass fibers can enhance the mechanical properties and osteogenic induction ability of calcium phosphate bone cement,among which 20%silicate bioactive glass fibers have a more obvious effect.
5.2023 China minimally invasive cardiovascular surgery statistics and future development thinking
Yao WANG ; Ye YANG ; Shuyang LU ; Zhe ZHENG ; Nianguo DONG ; Huiming GUO ; Song XUE ; Liming LIU ; Yingqiang GUO ; Xuezeng XU ; Lai WEI ; Chunsheng WANG
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(6):321-327
Objective:Committee of Minimally Invasive Cardiovascular Surgery(CMICS) conducts an annual summary of minimally invasive cardiovascular surgery procedures performed throughout the country, which includes a comprehensive survey of the total number of minimally invasive procedures by region and the distribution of minimally invasive procedures by hospital. Since CMICS first published the 2018-2019 China Minimally Invasive Cardiovascular Surgery Data White Paper in 2020, the report has received great attention from peers within and outside the industry. In this statistical report, CMICS will focus on publishing the data related to minimally invasive cardiovascular surgery in China from 2021 to 2023 for reference and use by industry peers.
6.Comparison of clinical efficacy and learning curve for robot-assisted cortical bone trajectory screw fixation performed by surgeons with different seniority in the treatment of lumbar degenerative disease
Yuzheng LU ; Wancheng LIN ; Jipeng SONG ; Yao ZHANG ; Siyuan YAO ; Meng YI ; Mingtao YAO ; Zhengning LUO ; Jiaqi YANG ; Lixiang DING ; Shengliang FU
Chinese Journal of Postgraduates of Medicine 2025;48(1):24-30
Objective:To analyze the clinical efficacy and learning curve for robot-assisted cortical bone trajectory (CBT) screw fixation performed by surgeons with different seniority in the treatment of lumbar degenerative disease.Methods:The clinical data of 91 lumbar degenerative disease patients underwent robot-assisted CBT screw fixation from August 2020 to December 2022 in Beijing Shijitan Hospital, Capital Medical University were retrospectively analyzed. Among them, 48 patients underwent surgery performed by the same senior surgeon (senior group), with a total of 234 CBT screws were placed; while 43 patients underwent surgery performed by the same junior surgeon (junior group), with a total of 206 CBT screws were placed. The surgical related indexes, functional improvement score, lower back pain and lower limb radiation pain scores, acceptable nail insertion rate, non invasion rate of facet joints and incidence of postoperative complications were compared between two groups. The functional improvement score was evaluated using the Japanese Orthopaedic Association (JOA) score, the pain score was evaluated using visual analog score (VAS). The cumulative sum (CUSUM) method was used to depict the learning curve with "single screw placement time" as the observation index.Results:There were no statistical difference in incision length, operation time, intraoperative blood loss and postoperative hospital stay between two groups ( P>0.05). The least squares means of JOA scores 1, 3 and 6 months after surgery in both groups increased significantly compared to baseline, while the least squares means of lower back pain VAS and lower limb radiation pain VAS decreased significantly compared to baseline; there were no statistical differences between two groups ( P>0.05). There were no statistical difference in acceptable nail insertion rate, non invasion rate of facet joints and incidence of postoperative complications between two group ( P>0.05). The CUSUM learning curves were fitting well and the inflection point for senior surgeon corresponded to 18 cases, while it was reached after performing surgery on 21 cases for junior surgeon. Conclusions:Robot-assisted CBT screw fixation performed by surgeons with different seniority could achieve similar clinical outcomes for treating lumbar degenerative disease. The senior surgeons are able to complete the initial learning stage faster than the junior surgeons, but there is not much difference in the number of surgeries performed the learning curve.
7.Intelligent head and neck CT angiography report quality detection using large language models
Liping TIAN ; Xiaolu FEI ; Dan SONG ; Yao LU ; Jie LU
Chinese Journal of Radiology 2025;59(10):1118-1125
Objective:To assess common errors in head and neck CT angiography (CTA) image reports using four types of large language models (LLM), namely GPT-4, DeepSeek, ERNIE Bot and SparkDesk, and to assess the feasibility of using existing LLMs to support quality control of radiology reports in Chinese.Methods:The study was a cross-sectional study. Totally 1 000 head and neck CTA image reports were randomly selected using the simple random sampling method from Xuanwu Hospital, Capital Medical University in 2023, including 500 primary reports and 500 finalized reports. Two radiologists collaboratively identified six types of errors in the reports: description errors, writing errors, left-right confusion errors, diagnostic omissions, logical sequence errors, and other errors. The overall quality of the reports was assessed using a 5-point Likert scale. Subsequently, GPT-4, DeepSeek, ERNIE Bot and SparkDesk models were employed to detect the same six types of errors in the imaging reports and to provide overall scoring. The results from manual review were considered the gold standard for calculating F1 score to evaluate model performance. Intra-class correlation coefficients ( ICC) were used to assess the consistency between manual scores and the overall scores from the four LLMs. Results:In the primary imaging reports, the proportions of manually detected errors were as follows: descriptive errors 2.6% (13/500), writing errors 0.6% (3/500), left-right confusion errors 0, diagnostic omissions 6.4% (32/500), logical sequence errors 5.2% (26/500), and other errors 0. In the finalized imaging reports, the proportions of errors across the six categories were 0.2% (1/500), 0, 0, 0, 0, and 0.2% (1/500), respectively. For error detection in the primary imaging reports, the F1 scores of GPT-4 for the six error types were 0.992, 0.997, 0.997, 0.967, 0.980, and 0.992, respectively. DeepSeek achieved F1 scores of 0.980, 0.955, 0.981, 0.920, 0.995, and 0.960; ERNIE Bot scored 0.982, 0.990, 1.000, 0.956, 0.976, and 0.999; and SparkDesk achieved 0.985, 0.995, 1.000, 0.961, 0.982, and 1.000. In the detection of errors in finalized imaging reports, GPT-4′s F1 scores were 0.994, 0.995, 0.998, 0.973, 0.989, and 0.993; DeepSeek scored 0.968, 0.965, 0.985, 0.971, 0.991, and 0.983; ERNIE Bot achieved 0.996, 0.992, 1.000, 0.983, 0.999, and 0.997; and SparkDesk achieved 0.999, 0.999, 1.000, 1.000, 1.000, and 0.999. The consistency between GPT-4, DeepSeek, and SparkDesk models and human ratings was moderate, with ICC values of 0.514, 0.560, and 0.515 respectively (all P0.001); in contrast, the overall score of ERNIE Bot showed poor consistency with human ratings, with an ICC of 0.221 ( P0.001). Conclusion:LLMs demonstrate high accuracy in detecting errors in head and neck CTA imaging reports. The overall scoring of report quality shows moderate consistency with manual assessments, indicating a certain feasibility for automated quality control in reporting.
8.Intelligent head and neck CT angiography report quality detection using large language models
Liping TIAN ; Xiaolu FEI ; Dan SONG ; Yao LU ; Jie LU
Chinese Journal of Radiology 2025;59(10):1118-1125
Objective:To assess common errors in head and neck CT angiography (CTA) image reports using four types of large language models (LLM), namely GPT-4, DeepSeek, ERNIE Bot and SparkDesk, and to assess the feasibility of using existing LLMs to support quality control of radiology reports in Chinese.Methods:The study was a cross-sectional study. Totally 1 000 head and neck CTA image reports were randomly selected using the simple random sampling method from Xuanwu Hospital, Capital Medical University in 2023, including 500 primary reports and 500 finalized reports. Two radiologists collaboratively identified six types of errors in the reports: description errors, writing errors, left-right confusion errors, diagnostic omissions, logical sequence errors, and other errors. The overall quality of the reports was assessed using a 5-point Likert scale. Subsequently, GPT-4, DeepSeek, ERNIE Bot and SparkDesk models were employed to detect the same six types of errors in the imaging reports and to provide overall scoring. The results from manual review were considered the gold standard for calculating F1 score to evaluate model performance. Intra-class correlation coefficients ( ICC) were used to assess the consistency between manual scores and the overall scores from the four LLMs. Results:In the primary imaging reports, the proportions of manually detected errors were as follows: descriptive errors 2.6% (13/500), writing errors 0.6% (3/500), left-right confusion errors 0, diagnostic omissions 6.4% (32/500), logical sequence errors 5.2% (26/500), and other errors 0. In the finalized imaging reports, the proportions of errors across the six categories were 0.2% (1/500), 0, 0, 0, 0, and 0.2% (1/500), respectively. For error detection in the primary imaging reports, the F1 scores of GPT-4 for the six error types were 0.992, 0.997, 0.997, 0.967, 0.980, and 0.992, respectively. DeepSeek achieved F1 scores of 0.980, 0.955, 0.981, 0.920, 0.995, and 0.960; ERNIE Bot scored 0.982, 0.990, 1.000, 0.956, 0.976, and 0.999; and SparkDesk achieved 0.985, 0.995, 1.000, 0.961, 0.982, and 1.000. In the detection of errors in finalized imaging reports, GPT-4′s F1 scores were 0.994, 0.995, 0.998, 0.973, 0.989, and 0.993; DeepSeek scored 0.968, 0.965, 0.985, 0.971, 0.991, and 0.983; ERNIE Bot achieved 0.996, 0.992, 1.000, 0.983, 0.999, and 0.997; and SparkDesk achieved 0.999, 0.999, 1.000, 1.000, 1.000, and 0.999. The consistency between GPT-4, DeepSeek, and SparkDesk models and human ratings was moderate, with ICC values of 0.514, 0.560, and 0.515 respectively (all P0.001); in contrast, the overall score of ERNIE Bot showed poor consistency with human ratings, with an ICC of 0.221 ( P0.001). Conclusion:LLMs demonstrate high accuracy in detecting errors in head and neck CTA imaging reports. The overall scoring of report quality shows moderate consistency with manual assessments, indicating a certain feasibility for automated quality control in reporting.
9.Mediating effect of sleep duration between depression symptoms and myopia in middle school students.
Wei DU ; Xu-Xiang YANG ; Ru-Shuang ZENG ; Chun-Yao ZHAO ; Zhi-Peng XIANG ; Yuan-Chun LI ; Jie-Song WANG ; Xiao-Hong SU ; Xiao LU ; Yu LI ; Jing WEN ; Dang HAN ; Qun DU ; Jia HE
Chinese Journal of Contemporary Pediatrics 2025;27(3):359-365
OBJECTIVES:
To explore the mediating role of sleep duration in the relationship between depression symptoms and myopia among middle school students.
METHODS:
This study was a cross-sectional research conducted using a stratified cluster random sampling method. A total of 1 728 middle school students were selected from two junior high schools and two senior high schools in certain urban areas and farms of the Xinjiang Production and Construction Corps. Questionnaire surveys and vision tests were conducted among the students. Spearman analysis was used to analyze the correlation between depression symptoms, sleep duration, and myopia. The Bootstrap method was employed to investigate the mediating effect of sleep duration between depression symptoms and myopia.
RESULTS:
The prevalence of myopia in the overall population was 74.02% (1 279/1 728), with an average sleep duration of (7.6±1.0) hours. The rate of insufficient sleep was 83.62% (1 445/1 728), and the proportion of students exhibiting depression symptoms was 25.29% (437/1 728). Correlation analysis showed significant negative correlations between visual acuity in both eyes and sleep duration with depressive emotions as measured by the Center for Epidemiologic Studies Depression Scale (with correlation coefficients of -0.064, -0.084, and -0.199 respectively; P<0.01), as well as with somatic symptoms and activities (with correlation coefficients of -0.104, -0.124, and -0.233 respectively; P<0.01) and interpersonal relationships (with correlation coefficients of -0.052, -0.059, and -0.071 respectively; P<0.05). The correlation coefficients for left and right eye visual acuity and sleep duration were 0.206 and 0.211 respectively (P<0.001). Sleep duration exhibited a mediating effect between depression symptoms and myopia (indirect effect=0.056, 95%CI: 0.029-0.088), with the mediating effect value for females (indirect effect=0.066, 95%CI: 0.024-0.119) being higher than that for males (indirect effect=0.042, 95%CI: 0.011-0.081).
CONCLUSIONS
Sleep duration serves as a partial mediator between depression symptoms and myopia in middle school students.
Humans
;
Myopia/etiology*
;
Male
;
Female
;
Depression/physiopathology*
;
Cross-Sectional Studies
;
Sleep
;
Adolescent
;
Students
;
Child
;
Time Factors
;
Sleep Duration
10.Erratum: Author Correction: Targeting of AUF1 to vascular endothelial cells as a novel anti-aging therapy.
Jian HE ; Ya-Feng JIANG ; Liu LIANG ; Du-Jin WANG ; Wen-Xin WEI ; Pan-Pan JI ; Yao-Chan HUANG ; Hui SONG ; Xiao-Ling LU ; Yong-Xiang ZHAO
Journal of Geriatric Cardiology 2025;22(9):834-834
[This corrects the article DOI: 10.11909/j.issn.1671-5411.2017.08.005.].


Result Analysis
Print
Save
E-mail