1.Experimental study of epigallocatechin gallate-loaded hydrogel scaffold for the treatment of periodontitis
Longge LIU ; Jing MAO ; Huimin ZHENG ; Wei LI
Acta Universitatis Medicinalis Anhui 2026;61(6):1013-1020
ObjectiveTo explore the structural characteristics, biocompatibility, anti-inflammatory and antioxidant properties of hyaluronic acid (HA)/silk fibroin (SF) composite hydrogel scaffolds loaded with epigallocatechin gallate (EGCG), and to provide a new material basis for the treatment of periodontitis. MethodsThe composite hydrogel scaffolds were constructed by cross-linking HA and SF and loaded with EGCG. The water absorption rate, degradation property and material characteristics were detected by scanning electron microscopy. The cytocompatibility and anti-inflammatory and antioxidant properties were evaluated by in vitro experiments. ResultsThe EGCG-loaded scaffolds exhibited a porous network structure and desirable swelling properties. In vitro experiments demonstrated that the scaffolds possessed good biocompatibility, along with the ability to inhibit the expression of inflammatory factors and scavenge reactive oxygen species. ConclusionThe HA/SF-EGCG composite scaffolds have excellent biocompatibility and dual functional activities of anti-inflammatory and antioxidant, providing a new strategy for improving the clinical treatment effect of periodontitis.
2.Dynamic assessment of tear-film stability-associated objective vision in mild or moderate dry eyes based on Optical Quality Analysis System parameters
Longge, SUN ; Zhongxu, MA ; Lin, MA ; Yanxia, LIU ; Yuan, GAO
Chinese Journal of Experimental Ophthalmology 2017;35(4):344-348
Background The progenesis and development of dry eye is closely associated with the stability of tear-film.Dry eyes often show the visual disturbance.Therefore,to evaluate the stability of tear-film based on visual quality and explore the relevant dynamic vision change in dry eyes is of important significance.Objective The aim of this study was to evaluate the dynamic changes of objective scattering index (OSI),modulation transfer function cut off (MTF cut off),objective visual acuity (OVA) with tear-film in the patients with mild or moderate dry eye disease using Optical Quality Analysis System.Methods A clinical diagnosis test was performed.Forty-two eyes of 42 consecutive patients with mild or moderate dry eyes were included in Tianjin Eye Hospital from December 2013 to May 2014 based on ‘ The Clinical Diagnosis and Treatment Recommendations for Dry Eye from Consensus of Expert Advice in 2013’,and 29 normal eyes of age-and gender-matched 29 healthy volunteers were simultaneously included as the healthy control group.The dynamic retinal images under non-blinking condition during 15 seconds were recorded by OQAS-Ⅱ system,and the OSI,MTF cut off and OVA values at 0,5,10 and 15 seconds were obtained,and the differences of OSI,MTF cut off and OVA between 0 second and 15 seconds were calculated (△OSI,△MTF cut off,△OVA).The dynamic changes of △OSI,△MTF cut off and △OVA with time were evaluated.The sensitivity and specificity of △OSI,△MTF cut off and △OVA for the differential diagnosis of dry eyes were analyzed by receiver operating characteristic curve (ROC curve).Results The OSI values at 5,10 and 15 seconds in the mild or moderate dry eye group were significantly higher than those at 0 second or those in the healthy control group (all at P<0.05),and the MTF cut off values and OVA values at 5,10 and 15 seconds in the mild or moderate dry eye group were significantly lower than those at 0 second or those in the healthy control group (all at P<0.05).The △OSI,△MTF cut off and △OVA values were 1.03±1.53,(-8.37±9.64)c/d and-0.30±0.32 in the mild or moderate dry eye group,which were significantly higher than 0.06± 0.16,(-0.37 ± 5.27) c/d and-0.03 ± 0.18 in the healthy control group (t=4.10,-5.19,-5.28,all at P<0.05).The area under ROC curve was 0.90,0.79 and 0.78 in △OSI,△MTF cut off and △OVA,respectively.The sensitivity and specificity of △OSI was 78.6% and 93.1% respectively at the diagnostic cut off of 0.3.Conclusions The optical quality parameters related with tear-film stability are gradually reduced with extending of time in mild or moderate dry eyes,but they are stable in healthy eyes.The detecting outcomes by OQAS-Ⅱ system can reflect the dynamic status of tear-film,and this method is of important clinical value for the differential diagnosis and optical quality evaluation in dry eyes.

Result Analysis
Print
Save
E-mail