1.Terms Related to The Study of Biomacromolecular Condensates
Ke RUAN ; Xiao-Feng FANG ; Dan LI ; Pi-Long LI ; Yi LIN ; Zheng WANG ; Yun-Yu SHI ; Ming-Jie ZHANG ; Hong ZHANG ; Cong LIU
Progress in Biochemistry and Biophysics 2025;52(4):1027-1035
Biomolecular condensates are formed through phase separation of biomacromolecules such as proteins and RNAs. These condensates exhibit liquid-like properties that can futher transition into more stable material states. They form complex internal structures via multivalent weak interactions, enabling precise spatiotemporal regulations. However, the use of inconsistent and non-standardized terminology has become increasingly problematic, hindering academic exchange and the dissemination of scientific knowledge. Therefore, it is necessary to discuss the terminology related to biomolecular condensates in order to clarify concepts, promote interdisciplinary cooperation, enhance research efficiency, and support the healthy development of this field.
2.Urban-rural disparities in mortality due to stroke subtypes in China and its provinces, 2015-2020.
Yi REN ; Jia YANG ; Peng YIN ; Wei LIU ; Zheng LONG ; Chen ZHANG ; Zixin WANG ; Haijie LIU ; Maigeng ZHOU ; Qingfeng MA ; Junwei HAO
Chinese Medical Journal 2025;138(11):1345-1354
BACKGROUND:
Death burden of stroke is severe with over one-third rural residents in China, but there is still a lack of specific national and high-quality reports on the urban-rural differences in stroke burden, especially for subtypes. We aimed to update the understanding of urban-rural differences in stroke deaths.
METHODS:
This is a descriptive observational study. Data from the national mortality surveillance system, which covers 323.8 million with 605 disease surveillance points (DSPs) across all 31 provinces, municipalities, and autonomous regions in China. All deaths from stroke as the underlying cause from 2015 to 2020 according to DSPs. Crude mortality rate and age-standardized mortality rate (ASMR) were estimated through DSPs. Average annual percentage change was used to explain the change in mortality rate.
RESULTS:
From 2015 to 2020, the majority of deaths from all stroke subtypes occurred in rural areas. There were significant differences between the changes of urban and rural ASMRs. On the whole, the changes in urban areas were evidently better, and the ASMR differences were basically expanding. Stroke ASMR in urban China decreased by 15.5%. The rural ASMR of ischemic stroke increased by 12.9%. The rural and urban ASMRs of intracerebral hemorrhage decreased by 24.9% and 27.4%, and those of subarachnoid hemorrhage decreased by 29.5% and 40.4%, respectively. The highest ASMRs of all stroke subtypes and the increasing trend of ischemic stroke ASMR make rural males the focus of stroke management.
CONCLUSIONS
The death burden of stroke varies greatly between urban and rural China. Rural residents face unique challenges.
Humans
;
China/epidemiology*
;
Stroke/mortality*
;
Rural Population/statistics & numerical data*
;
Male
;
Female
;
Urban Population/statistics & numerical data*
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Adult
3.Studies on the best production mode of traditional Chinese medicine driven by artificial intelligence and its engineering application.
Zheng LI ; Ning-Tao CHENG ; Xiao-Ping ZHAO ; Yi TAO ; Qi-Long XUE ; Xing-Chu GONG ; Yang YU ; Jie-Qiang ZHU ; Yi WANG
China Journal of Chinese Materia Medica 2025;50(12):3197-3203
The traditional Chinese medicine(TCM) industry is a crucial part of China's pharmaceutical sector and plays a strategic role in ensuring public health and promoting economic and social development. In response to the practical demand for high-quality development of the TCM industry, this paper focused on the bottlenecks encountered during the digital and intelligent transformation of TCM production systems. Specifically, it explored technical strategies and methodologies for constructing the best TCM production mode. An innovative artificial intelligence(AI)-centered technical architecture for TCM production was proposed, focusing on key aspects of production management including process modeling, state evaluation, and decision optimization. Furthermore, a series of critical technologies were developed to realize the best TCM production mode. Finally, a novel AI-driven TCM production mode characterized by a closed-loop system of "measurement-modeling-decision-execution" was presented through engineering case studies. This study is expected to provide a technological pathway for developing new quality productive forces within the TCM industry.
Artificial Intelligence
;
Drugs, Chinese Herbal
;
Medicine, Chinese Traditional/methods*
;
Humans
4.Development of oral preparations of poorly soluble drugs based on polymer supersaturated self-nanoemulsifying drug delivery technology.
Xu-Long CHEN ; Jiang-Wen SHEN ; Wei-Wei ZHA ; Jian-Yun YI ; Lin LI ; Zhang-Ting LAI ; Zheng-Gen LIAO ; Ye ZHU ; Yue-Er CHENG ; Cheng LI
China Journal of Chinese Materia Medica 2025;50(16):4471-4482
Poor water solubility is the primary obstacle preventing the development of many pharmacologically active compounds into oral preparations. Self-nanoemulsifying drug delivery systems(SNEDDS) have become a widely used strategy to enhance the oral bioavailability of poorly soluble drugs by inducing a supersaturated state, thereby improving their apparent solubility and dissolution rate. However, the supersaturated solutions formed in SNEDDS are thermodynamically unstable systems with solubility levels exceeding the crystalline equilibrium solubility, making them prone to drug precipitation in the gastrointestinal tract and ultimately hindering drug absorption. Therefore, maintaining a stable supersaturated state is crucial for the effective delivery of poorly soluble drugs. Incorporating polymers as precipitation inhibitors(PPIs) into the formulation of supersaturated self-nanoemulsifying drug delivery systems(S-SNEDDS) can inhibit drug aggregation and crystallization, thus maintaining a stable supersaturated state. This has emerged as a novel preparation strategy and a key focus in SNEDDS research. This review explores the preparation design of SNEDDS and the technical challenges involved, with a particular focus on polymer-based S-SNEDDS for enhancing the solubility and oral bioavailability of poorly soluble drugs. It further elucidates the mechanisms by which polymers participate in transmembrane transport, summarizes the principles by which polymers sustain a supersaturated state, and discusses strategies for enhancing drug absorption. Altogether, this review provides a structured framework for the development of S-SNEDDS preparations with stable quality and reduced development risk, and offers a theoretical reference for the application of S-SNEDDS technology in improving the oral bioavailability of poorly soluble drugs.
Solubility
;
Administration, Oral
;
Polymers/chemistry*
;
Drug Delivery Systems/methods*
;
Humans
;
Emulsions/chemistry*
;
Biological Availability
;
Animals
;
Pharmaceutical Preparations/administration & dosage*
5.Comparison of short-term clinical efficacy between CO external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures.
Min-Rui FU ; Chang-Long SHI ; Yong-Zhong CHENG ; Ming-Ming MA ; Zheng-Lin NIU ; Hai-Xiang SUN ; Jing-Hua GAO ; Zhong-Kai WU ; Yi-Ming XU
China Journal of Orthopaedics and Traumatology 2025;38(1):10-17
OBJECTIVE:
To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).
METHODS:
Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.6±11.3) years old. Among them, there were 7 patients of traffic accidents and 18 patients of falls, resulting in a total of 25 patients of closed fractures and no open fractures, the treatment was conducted using closed reduction and CO external fixation. The internal fixation group consisted of 23 patients, comprising 8 males and 15 females, age ranged from 41 to 59 years old, with an average age of(53.3±13.7) years old. Among them, 8 patients resulted from car accidents while the remaining 15 patients were caused by falls. All 23 patients were closed fractures without any open fractures observed. The technique of open reduction and internal fixation with steel plate was employed. The perioperative data, including injury-operation time, operation duration, blood loss, and length of hospital stay, were assessed in both groups. Additionally, the QuickDASH score and visual analogue scale (VAS) were evaluated. Range of motion and grip strength assessment, imaging findings such as palmar inclination angle, ulnar declination angle, radius length, articular surface step, intra-articular space measurements were also examined along with any complications.
RESULTS:
The follow-up duration ranged from 0 to 24 months, with an average duration of (16.0±3.8) months. The CO external fixation exhibited significantly shorter time from injury to operation (2.4±3.3) d vs (7.4±3.7) d, shorter operation duration (56.27±15.23) min vs (74.10±5.26) min, lower blood loss (14.52±6.54) ml vs (32.32±10.03) ml, and reduced hospitalization days (14.04±3.24 )d vs (16.45±3.05) d compared to the internal fixation group (P<0.05). The QuickDASH score at 12 months post-operation was (8.21±1.64) in the CO external fixation group, while no significant difference was observed in the internal fixation group (7.04±3.64), P>0.05. There were no statistically significant differences in VAS between two groups at 6 weeks, as well as 1 and 3 months post-surgery (P>0.05). Additionally, there were no significant disparities observed in terms of range of motion and grip strength between two groups at the 2-year follow-up after the operation (P>0.05). After 12 months of surgery, the CO external fixation group exhibited a significantly smaller palmar inclination angle (17.90±2.18) ° vs (19.87±3.21) °, reduced articular surface step (0.11±0.03) mm vs (0.17±0.02) mm, and shorter radius length (8.16±1.11) mm compared to the internal fixation group (9.59±1.02) mm, P<0.05. The ulnar deviation angle and intra-articular space did not show any significant difference between two groups (P>0.05). The reduced fell within the allowable range between the CO external fixation group (23 out of 25 cases) and the internal fixation group (21 out of 23 cases) was not statistically significant (P=0.29). There was no significant difference in complications between the two groups(P>0.05).
CONCLUSION
Both the CO external fixation and open reduction with plate internal fixation demonstrate clinical efficacy in managing unstable distal radius fractures. The CO external fixation offers advantages in shorter injury-to-operation times, reduced intraoperative blood loss, and decreased surgical durations, while radial shortening is more effectively controlled by internal fixation.
Humans
;
Male
;
Female
;
Middle Aged
;
Radius Fractures/physiopathology*
;
Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
External Fixators
;
Retrospective Studies
;
Fracture Fixation/methods*
;
Wrist Fractures
6.Digital study of IdebergⅡregional pelvic fracture anatomical plate based on 3D metal printing technology.
Yi ZHANG ; Jia-Kai ZHANG ; Jun-Long WU ; Yi ZHENG
China Journal of Orthopaedics and Traumatology 2025;38(3):293-297
OBJECTIVE:
To establish digital model of Ideberg typeⅡregional glenoid fracture anatomical plate with 3D metal printing technology.
METHODS:
The scapular imaging data of a 34-year-old healthy male volunteer were retrospectively selected. Mimics 15.01, NX 12.0 and other software were used to design Ideberg typeⅡ regional scapular fracture guide plate system. STL data were input into a metal 3D printer to print 1∶1 scapular model and anatomical plate of scapular pelvis with guide sleeve. The fit of the plate was tested in vitro and the accuracy of the screw position was evaluated by imaging. The printing time of scapular model, design of the nail path and making time of the anatomic guided plate were recorded.
RESULTS:
3D metal-printed Ideberg typeⅡ guide plate for scapular fracture fitted well to 3D printed scapular model, the locking screw was oriented accurately, and X-ray and CT showed good screw position. The printing time of scapula model, time of nail path design and special-shaped anatomical guide plate production were 52.0, 15.0 and 320 min, respectively.
CONCLUSION
Anatomical plates based on 3D metal printing technology could achieve good adhesion of Ideberg typeⅡ regional fractures and precise screw placement, providing a new and accurate surgical method for the treatment of Ideberg typeⅡ glenoid fractures.
Humans
;
Printing, Three-Dimensional
;
Male
;
Adult
;
Bone Plates
;
Fractures, Bone/diagnostic imaging*
;
Fracture Fixation, Internal/methods*
;
Pelvic Bones/surgery*
;
Metals
;
Scapula/surgery*
;
Models, Anatomic
7.Impact of posterior cruciate ligament resection on the elasticity of the periarticular soft tissue sleeve in the knee joint.
Yun-Feng ZHANG ; De-Jin YANG ; Zhao-Lun WANG ; Yi-Xin ZHOU ; Hao TANG ; Xiang-Dong WU ; Han-Long ZHENG
China Journal of Orthopaedics and Traumatology 2025;38(10):1055-1060
OBJECTIVE:
To evaluate the effects of posterior cruciate ligament(PCL) resection on soft tissue elasticity and knee stability in total knee arthroplasty(TKA).
METHODS:
Six adult cadaveric knee specimens (involving 10 knees) were included in the study. With the assistance of the robotic system(TiRobot Recon, TINAVI, Beijing), total knee arthroplasty (TKA) was performed sequentially using cruciate retaining (CR) prostheses and posterior stabilizing (PS) prostheses. Between the two surgical procedures, the femoral and tibial osteotomy surfaces were not altered;only the posterior cruciate ligament (PCL) was resected and the intercondylar fossa was treated. After installing the femoral trial component, a soft tissue balance solver was used to apply tension ranging from 30 N to 90 N in 5 N increments at 0°, 10°, and 90° of knee flexion. Meanwhile, the medial and lateral joint gaps were measured synchronously. Based on the tension-gap coupling data, the equivalent elastic coefficients of the medial and lateral soft tissue sleeves at different knee flexion angles, as well as the range of the joint line convergence angle (JLCA) under fixed varus-valgus stress, were calculated. Additionally, the gap balance status under 80 N of tension was analyzed. Self-control comparisons of each indicator were conducted before and after PCL resection to analyze the change patterns.
RESULTS:
After PCL resection, in the fully extended position (knee flexion 0°). The medial equivalent elastic coefficient was 32.2 (25.7, 63.3) N·mm-1 for the CR prosthesis and 27.7 (22.0, 51.9) N·mm-1 for the PS prosthesis, and the statistically significant difference (P=0.013). The range of JLCA was 0.41°(0.26, 0.55)° for the CR prosthesis, which was smaller than 0.75° (0.40, 0.98)° for the PS prosthesis, and the difference was statistically significant(P=0.041). At 90° of knee flexion, the medial joint gap was 10.7(10.1, 11.7) mm for the CR prosthesis, which was smaller than 12.1(10.9, 15.1) mm for the PS prosthesis, with a statistically significant difference(P=0.011). No statistically significant differences were observed in other joint gaps.
CONCLUSION
PCL resection reduces the rigidity of the medial soft tissues in the fully extended knee and increases the medial joint gap in the flexed position, thereby affecting knee stability and balance. This finding suggests that PS and CR prostheses may require different morphological designs, and there should be differences in indications and osteotomy strategies between CR-TKA and PS-TKA. CR-TKA is more suitable for patients with preoperative medial soft tissue laxity.
Humans
;
Posterior Cruciate Ligament/physiopathology*
;
Knee Joint/physiopathology*
;
Arthroplasty, Replacement, Knee
;
Elasticity
;
Male
;
Female
;
Middle Aged
;
Aged
;
Biomechanical Phenomena
;
Adult
8.Qingda Granule Attenuates Hypertension-Induced Cardiac Damage via Regulating Renin-Angiotensin System Pathway.
Lin-Zi LONG ; Ling TAN ; Feng-Qin XU ; Wen-Wen YANG ; Hong-Zheng LI ; Jian-Gang LIU ; Ke WANG ; Zhi-Ru ZHAO ; Yue-Qi WANG ; Chao-Ju WANG ; Yi-Chao WEN ; Ming-Yan HUANG ; Hua QU ; Chang-Geng FU ; Ke-Ji CHEN
Chinese journal of integrative medicine 2025;31(5):402-411
OBJECTIVE:
To assess the efficacy of Qingda Granule (QDG) in ameliorating hypertension-induced cardiac damage and investigate the underlying mechanisms involved.
METHODS:
Twenty spontaneously hypertensive rats (SHRs) were used to develope a hypertension-induced cardiac damage model. Another 10 Wistar Kyoto (WKY) rats were used as normotension group. Rats were administrated intragastrically QDG [0.9 g/(kg•d)] or an equivalent volume of pure water for 8 weeks. Blood pressure, histopathological changes, cardiac function, levels of oxidative stress and inflammatory response markers were measured. Furthermore, to gain insights into the potential mechanisms underlying the protective effects of QDG against hypertension-induced cardiac injury, a network pharmacology study was conducted. Predicted results were validated by Western blot, radioimmunoassay immunohistochemistry and quantitative polymerase chain reaction, respectively.
RESULTS:
The administration of QDG resulted in a significant decrease in blood pressure levels in SHRs (P<0.01). Histological examinations, including hematoxylin-eosin staining and Masson trichrome staining revealed that QDG effectively attenuated hypertension-induced cardiac damage. Furthermore, echocardiography demonstrated that QDG improved hypertension-associated cardiac dysfunction. Enzyme-linked immunosorbent assay and colorimetric method indicated that QDG significantly reduced oxidative stress and inflammatory response levels in both myocardial tissue and serum (P<0.01).
CONCLUSIONS
Both network pharmacology and experimental investigations confirmed that QDG exerted its beneficial effects in decreasing hypertension-induced cardiac damage by regulating the angiotensin converting enzyme (ACE)/angiotensin II (Ang II)/Ang II receptor type 1 axis and ACE/Ang II/Ang II receptor type 2 axis.
Animals
;
Drugs, Chinese Herbal/therapeutic use*
;
Hypertension/pathology*
;
Renin-Angiotensin System/drug effects*
;
Rats, Inbred SHR
;
Oxidative Stress/drug effects*
;
Male
;
Rats, Inbred WKY
;
Blood Pressure/drug effects*
;
Myocardium/pathology*
;
Rats
;
Inflammation/pathology*
9.Digital study on proximal clavicle anatomical plate based on 3D printing technology
Yi ZHENG ; Xing-Guo ZHENG ; Jia-Kai ZHANG ; Jun-Long WU ; Xin-Hua YUAN
China Journal of Orthopaedics and Traumatology 2024;37(3):278-280
Objective To explore feasibility of 3D metal printing technology combined with virtual design proximal clavicle anatomical plate.Methods A 52-year-old male healthy volunteer was retrospectively selected to design proximal clavicle anatomical plate system by using Mimics15.01,NX12.0 and other software.STL data were input into 3D printer to print 1∶1 clavicle model and proximal clavicle anatomical plate.The fit of the plate was tested in vitro and the accuracy of screw position was evaluated by imaging.Printing time of model,nail path design and fabrication time of the anatomical plate at proximal clavicle were recorded.Results The 3D metal printing proximal clavicle anatomical plate fitted well to clavicle model,orienta-tion of proximal clavicle locking screw was accurate,and X-ray and CT scan showed the screw position was good.Printing time of model,the time of nail path design,and the time of making anatomical plate of proximal clavicle were 120,15 and 300 min respectively.Conclusion The proximal clavicular anatomical plate system based on 3D metal printing technology could achieve good lamination of proximal clavicular fracture plate and precise screw placement,providing a new and accurate surgical method for the treatment of the proximal clavicular fracture.
10.Finite element analysis of anatomic plate fixation for proximal clavicular fractures
Yi ZHENG ; Jia-Kai ZHANG ; Jun-Long WU ; Xin-Hua YUAN
China Journal of Orthopaedics and Traumatology 2024;37(9):917-920
Objective To explore establishment and finite element analysis of personalized proximal clavicular anatomical plate screw fixation model.Methods A 40-year-old male healthy volunteer was selected and the finite element analysis modules of 3D reconstruction software Mimics 15.01,Hypermesh 2019 and Abaqus 2020 were used.The finite element model of anatomic plate at the proximal clavicle was established,and a vertical load of 250 N was applied to the distal end of long axis of clavicle about 15 mm,then the overall structure,plate and screw displacement cloud image,Mises stress distribution were ob-served.Results The displacement distribution of the overall structure shows the maximum displacement was distributed on the distal clavicle.Under the four conditions of normal upper limb weight,longitudinal clavicle fracture,oblique fracture and shoulder impact violence during fall,longitudinal clavicle fracture and oblique fracture,the maximum displacement were 1.04 mm,1.03 mm,1.35 mm and 1.33 mm,respectively.The displacement cloud map of titanium alloy steel plate showed the largest displacement was distributed near the distal clavicular bone,and the maximum displacement were 0.89 mm,0.88 mm,1.10 mm and 1.09 mm,respectively.The displacement cloud map of titanium alloy screw showed the largest displacement was distribut-ed at the root of the distal screw,and the maximum displacement were 0.88 mm,0.87 mm,1.08 mm and 1.06 mm,respectively.Mises stress distribution showed the maximum stress was mainly distributed on titanium alloy plates and screws,and the stress on the clavicle was very small.Mises stress distribution cloud showed the maximum Mises stress was distributed at the second row of screw holes near the clavicle,and the maximum Mises stress were 673.1,678.1,648.5,654.4 MPa,respectively.The maximum stresses of titanium alloy screws were 414.5,417.4,415.8 and 419.7 MPa,respectively.Conclusion The biomechan-ical changes of personalized proximal clavicular anatomical plates are demonstrated by using 3D finite element method to pro-vide biomechanical data for personalized proximal clavicular anatomical plates.

Result Analysis
Print
Save
E-mail