1.Yimei Baijiang Formula Treats Colitis-associated Colorectal Cancer in Mice via NF-κB Signaling Pathway
Qian WU ; Xin ZOU ; Chaoli JIANG ; Long ZHAO ; Hui CHEN ; Li LI ; Zhi LI ; Jianqin LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(3):119-130
ObjectiveTo explore the effects of Yimei Baijiang formula (YMBJF) on colitis-associated colorectal cancer (CAC) and the nuclear factor kappaB (NF-κB) signaling pathway in mice. MethodsSixty male Balb/c mice of 4-6 weeks old were randomized into 6 groups: Normal, model, capecitabine (0.83 g
2.Yimei Baijiang Formula Treats Colitis-associated Colorectal Cancer in Mice via NF-κB Signaling Pathway
Qian WU ; Xin ZOU ; Chaoli JIANG ; Long ZHAO ; Hui CHEN ; Li LI ; Zhi LI ; Jianqin LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(3):119-130
ObjectiveTo explore the effects of Yimei Baijiang formula (YMBJF) on colitis-associated colorectal cancer (CAC) and the nuclear factor kappaB (NF-κB) signaling pathway in mice. MethodsSixty male Balb/c mice of 4-6 weeks old were randomized into 6 groups: Normal, model, capecitabine (0.83 g
3.Predictive model for severe adverse reaction associated with bevacizumab based on the global trigger tool and machine learning
Yongfei FU ; Xin LONG ; Hongzhen XU ; Jian TANG ; Xiangqing LI ; Yucheng LONG ; Dong QIN
China Pharmacy 2026;37(4):497-503
OBJECTIVE To confirm trigger items for adverse drug reaction (ADR) induced by bevacizumab, to identify and analyze the occurrence of related ADR, and to establish a predictive model for severe adverse reaction (SAR) caused by this drug. METHODS Based on the global trigger tool (GTT) theory, and referencing the GTT White Paper, drug package inserts and relevant literature, trigger items for bevacizumab-related ADR were confirmed using a single-round Delphi method. Utilizing these established items, electronic medical records of relevant patients at Guilin People’s Hospital from January 2020 to September 2024 were actively screened via the China Hospital Pharmacovigilance System. Pharmacists then identified and tallied the occurrence of bevacizumab-induced ADR. Data from patients with any positive trigger item served as the study subjects (divided into training and test sets at a ratio of 7∶3), candidate feature variables were selected from 39 related variables using the Boruta algorithm, and the multivariable Logistic regression analysis was performed with the occurrence of SAR as the dependent variable. Based on these candidate features, Logistic Regression, Extreme Gradient Boosting, Light Gradient Boosting Machine, Random Forest, and Categorical Boosting models were constructed. Model performance was evaluated using metrics including the area under the curve (AUC) of receiver operating characteristic curve and recall rate. The Shapley Additive exPlanations (SHAP) method was applied to analyze and interpret the contribution of each variable. A nomogram was constructed based on the optimal model. RESULTS A total of 38 trigger items for active monitoring of bevacizumab-related ADR were determined, comprising 17 laboratory indicators, 13 clinical manifestations, and 8 intervention measures. In total, 483 patients with positive trigger items were included, and 318 patients with bevacizumab-induced ADR were identified, including 83 SARs. The positive predictive values for the trigger items and cases were 43.57% (708/1 625) and 63.84% (318/483), respectively. Bevacizumab-induced ADR involved 7 systems/organs, with the hematological system being the most frequently involved (64.15%). The Boruta algorithm selected 7 vari ables: serum potassium, hematocrit, albumin-to-globulin ratio, prealbumin, hypertension history, age and red blood cell count. Multivariable Logistic regression showed that elevated serum potassium levels were associated with a decreased risk of bevacizumab-induced SAR (OR=0.234, P =0.002), while a history of hypertension (OR=2.642, P =0.006) and increased age (OR=1.040, P =0.025) were associated with an increased risk. The Logistic Regression model demonstrated superior performance with higher AUC, F1 score and recall rate (0.761, 0.447, 0.607), compared to other models. SHAP evaluation results indicated that variables such as serum potassium, hematocrit, and age ranked highest in importance. CONCLUSIONS Totally 38 trigger entries have been successfully identified for active screening of bevacizumab-related ADR. Elevated serum potassium levels are a protective factor against bevacizumab-induced SAR, whereas the hypertension history and increased age are risk factors. The Logistic Regression model is the optimal predictive model.
4.Reactive and Enzyme-activated Probe Strategies for Imaging Acute Kidney Injury
Ru-Long CHEN ; Ting-Fei XIE ; Jin-Xin ZHANG ; Jia-Ting CHEN ; Jie LI ; Peng-Fei ZHANG ; Ji-Hong CHEN ; Lin-Tao CAI
Progress in Biochemistry and Biophysics 2026;53(6):1622-1637
Acute kidney injury (AKI) is a prevalent and life-threatening clinical syndrome characterised by a rapid decline in renal function and diverse pathological etiologies. The condition has been demonstrated to be associated with elevated mortality rates and an increased risk of progression to chronic kidney disease. At present, clinicians depend heavily on conventional functional markers, such as serum creatinine and urine output, for the diagnosis and staging of the disease. It is evident that these conventional indicators characteristically manifest a considerable temporal delay and only undergo modification subsequent to considerable tissue damage. This severely restricts the timeframe for early detection and timely therapeutic intervention. Furthermore, standard markers fail to provide specific biological information regarding the underlying cellular injury mechanisms. The utilisation of advanced probe technologies in molecular imaging offers a robust alternative to overcome these inherent diagnostic limitations.This comprehensive review systematically evaluates recent progress in the design and application of two primary categories of molecular imaging tools for acute kidney disease, specifically reactive probes and enzyme-activated probes. Reactive probes are engineered to specifically interact with redox-active chemical species, including hydrogen peroxide, peroxynitrite, hypochlorous acid, and sulfur dioxide. Because oxidative stress constitutes a primary early event in acute renal tubular damage, these probes enable researchers and clinicians to visualize early cellular injury and radical accumulation well before global renal functional decline becomes evident. We discuss the application of these reactive probes across multiple imaging modalities including fluorescence imaging, magnetic resonance imaging (MRI), positron emission tomography (PET), and photoacoustic techniques. Photoacoustic imaging combines high spatial resolution with deep tissue penetration and has successfully demonstrated the ability to provide diagnostic alerts up to 12 h before any detectable rise in serum creatinine levels. Additionally, specific reactive probes have shown promising translational potential when tested by high-throughput screening in clinical human urine samples. Enzyme-activated probes target the specific catalytic activity of disease-relevant enzymes. These include well-documented renal tubular structural biomarkers such as NAG, GGT, and ALP, along with apoptosis-related caspases and specific nitroreductases. By responding only to enzymatic cleavage, these tools provide highly specific and pathology-directed imaging readouts. Recent structural design strategies in this field have advanced significantly beyond single-enzyme detection. Researchers are now focusing on sophisticated dual-target recognition to minimize background noise, multimodal integration to cross-validate imaging signals, and theranostic applications where probes simultaneously deliver diagnostic feedback and therapeutic agents to injured tissues. Nanotechnology serves as a fundamental enabler for realizing these advanced probe functions. By precisely optimizing nanoparticle parameters such as hydrodynamic size, surface charge, and targeting ligands, researchers can achieve amplified signal output, highly precise kidney delivery, and protection against premature degradation in the systemic circulation. For example, modifying surface charges can significantly enhance the active uptake of nanoprobes by damaged renal tubular epithelial cells.While preclinical probe development has progressed rapidly, moving these technologies into routine clinical practice remains a major challenge. We analyze the translational feasibility and current obstacles from biological, technological, and regulatory perspectives. Although biological targets such as KIM-1, FAP, and ALP have been validated in extensive patient cohorts, practical barriers severely limit their immediate clinical application. These obstacles involve complex changes in in vivo pharmacokinetics. During an acute injury episode, the extreme drop in the glomerular filtration rate alters probe clearance and can cause unwanted systemic accumulation or confusing background imaging signals. Other major hurdles include a lack of comprehensive long-term toxicity data and the absence of standardized manufacturing protocols to ensure batch-to-batch consistency. Future successful translation will require rigorous multi-center clinical studies to confirm the true diagnostic value of these probes over traditional markers. Researchers must also establish strict standardization of imaging procedures and comprehensive safety evaluations. Ultimately, this review provides a thorough reference framework for designing clinically translatable molecular probes and building a precision diagnostic imaging system for acute kidney injury.
5.Chinese experts' consensus on principles of preoperative hair removal
Yiping MAO ; Jun ZHENG ; Lei LI ; Deyan YANG ; Bing ZHANG ; Lei YANG ; Wang JIA ; Peng KANG ; Hui JIAO ; Yun YANG ; Qi QI ; Shiqing FENG ; Xiao LONG ; Yuewei ZHANG ; Xiaohui WANG ; Lize WANG ; Yuan WEI ; Jichao ZHOU ; Minghui MAO ; Pengju XIN ; Hongyu TAN ; Dahong ZHANG ; Lianxin LIU ; Lei TAO ; Xietong WANG ; Xiaoning YUAN ; Mang CAI ; Li MU ; Fang DU ; Rongzhu CHEN ; Fengmao ZHAO ; Jiuzuo HUANG ; Mingzi ZHANG ; Jie ZHANG ; Baoguo WANG ; Kun WANG ; Fang LUO ; Jinhua ZHANG ; Nong HE ; Ling LYU ; Zhiyong ZONG
Chinese Journal of Nosocomiology 2025;35(10):1441-1449
To formulate an expert consensus on the principles of preoperative hair removal and provide scientific guidance for standardized removal of hair before surgical procedures so as to reduce the incidence of surgical site infections.METHODS Led by the Hospital Management Institute of National Health Commission of the People's Republic of China,this consensus was reached with the joint efforts from the expects of relevant fields such as surgeries,interventional therapies,nursing,and infection prevention and control.The consensus facilitates the classification and evaluation of literatures by following the evidence grade formulated by Oxford Evidence-based Medicine Center and focuses on the association of preoperative hair removal with surgical site infection,it reaches the evidence grade of expert consensus and recommendation intensity by integrating with discussions on meetings and clinical experience of the expects from relevant fields.RESULTS A total of 6 items of consensus were reached by summarizing the latest evidence on the aspects including the indications for preoperative hair removal,tools,range,timing and places.CONCLUSION The consensus,to some extent,make supplements to and complete the exiting regulations and standards.It provides guidance for the medical institutions to carry out the preoperative hair removal.
6.Chinese experts' consensus on principles of preoperative hair removal
Yiping MAO ; Jun ZHENG ; Lei LI ; Deyan YANG ; Bing ZHANG ; Lei YANG ; Wang JIA ; Peng KANG ; Hui JIAO ; Yun YANG ; Qi QI ; Shiqing FENG ; Xiao LONG ; Yuewei ZHANG ; Xiaohui WANG ; Lize WANG ; Yuan WEI ; Jichao ZHOU ; Minghui MAO ; Pengju XIN ; Hongyu TAN ; Dahong ZHANG ; Lianxin LIU ; Lei TAO ; Xietong WANG ; Xiaoning YUAN ; Mang CAI ; Li MU ; Fang DU ; Rongzhu CHEN ; Fengmao ZHAO ; Jiuzuo HUANG ; Mingzi ZHANG ; Jie ZHANG ; Baoguo WANG ; Kun WANG ; Fang LUO ; Jinhua ZHANG ; Nong HE ; Ling LYU ; Zhiyong ZONG
Chinese Journal of Nosocomiology 2025;35(10):1441-1449
To formulate an expert consensus on the principles of preoperative hair removal and provide scientific guidance for standardized removal of hair before surgical procedures so as to reduce the incidence of surgical site infections.METHODS Led by the Hospital Management Institute of National Health Commission of the People's Republic of China,this consensus was reached with the joint efforts from the expects of relevant fields such as surgeries,interventional therapies,nursing,and infection prevention and control.The consensus facilitates the classification and evaluation of literatures by following the evidence grade formulated by Oxford Evidence-based Medicine Center and focuses on the association of preoperative hair removal with surgical site infection,it reaches the evidence grade of expert consensus and recommendation intensity by integrating with discussions on meetings and clinical experience of the expects from relevant fields.RESULTS A total of 6 items of consensus were reached by summarizing the latest evidence on the aspects including the indications for preoperative hair removal,tools,range,timing and places.CONCLUSION The consensus,to some extent,make supplements to and complete the exiting regulations and standards.It provides guidance for the medical institutions to carry out the preoperative hair removal.
7.CFD-based performance analysis of flow field-based biosafety high efficiency particulate air filter device
Yan-ju LI ; Ji-xin CUI ; Yun-li BAO ; Xue-long YANG
Chinese Medical Equipment Journal 2025;46(9):22-27
Objective To explore the effects of the disinfection port position and diameter and disinfectant concentration on the in-situ decontamination of the flow field-based biosafety high efficiency particulate air filter device with the computational fluid dynamics(CFD)method.Methods ANSYS DesignModeler was used to construct five models for the high efficiency particulate air filter device with the disinfection port at the side end in four ones and upper end in the remained one model,with the diameter being 70,100,150,260 and 260 mm respectively;secondly,a standard k-ε turbulence model was applied to simulating the velocity field and concentration field inside the high efficiency particulate air filter device,so as to analyze the influence of the vortex position inside the device and the structure of the device on the disinfection effect and to determine the optimal structure of the device;finally,H2O2 with the concentration of 0.45,0.35 or 0.30 mol/L was selected as the disinectant to investigate the effect of the disinfectant concentration on the disinfection under the optimal device structure.Results Simulation showed that there were vortexes existed the cavity between the filter compression structure and the filter of the high efficiency particulate air filter device.The disinfection effect in case of the disinfection port at the side end was higher than that in case of the disinfection port at the upper end;the diameter of the disinfection port had influences on the disinfection effect,and high-concentration disinfectant was found in the device when the diameter was 100 mm.The optimal structure with the disinfection port at the side end and the diameter of 100 mm was determined for the high efficiency particulate air filter device.An increase in H2O2 concentration was beneficial to improve disinfection without corroding and damaging the device when the in-situ decontamination of the flow field-based biosafety high efficiency particulate air filter device was carried out.Conclusion The characteristics of the internal flow field of the flow field-based biosafety high efficiency particulate air filter device and the influencing factors of the in-situ disinfection effect are revealed,and theoretical references are provided for the optimal design of the device.[Chinese Medical Equipment Journal,2025,46(9):22-27]
8.CFD-based performance analysis of flow field-based biosafety high efficiency particulate air filter device
Yan-ju LI ; Ji-xin CUI ; Yun-li BAO ; Xue-long YANG
Chinese Medical Equipment Journal 2025;46(9):22-27
Objective To explore the effects of the disinfection port position and diameter and disinfectant concentration on the in-situ decontamination of the flow field-based biosafety high efficiency particulate air filter device with the computational fluid dynamics(CFD)method.Methods ANSYS DesignModeler was used to construct five models for the high efficiency particulate air filter device with the disinfection port at the side end in four ones and upper end in the remained one model,with the diameter being 70,100,150,260 and 260 mm respectively;secondly,a standard k-ε turbulence model was applied to simulating the velocity field and concentration field inside the high efficiency particulate air filter device,so as to analyze the influence of the vortex position inside the device and the structure of the device on the disinfection effect and to determine the optimal structure of the device;finally,H2O2 with the concentration of 0.45,0.35 or 0.30 mol/L was selected as the disinectant to investigate the effect of the disinfectant concentration on the disinfection under the optimal device structure.Results Simulation showed that there were vortexes existed the cavity between the filter compression structure and the filter of the high efficiency particulate air filter device.The disinfection effect in case of the disinfection port at the side end was higher than that in case of the disinfection port at the upper end;the diameter of the disinfection port had influences on the disinfection effect,and high-concentration disinfectant was found in the device when the diameter was 100 mm.The optimal structure with the disinfection port at the side end and the diameter of 100 mm was determined for the high efficiency particulate air filter device.An increase in H2O2 concentration was beneficial to improve disinfection without corroding and damaging the device when the in-situ decontamination of the flow field-based biosafety high efficiency particulate air filter device was carried out.Conclusion The characteristics of the internal flow field of the flow field-based biosafety high efficiency particulate air filter device and the influencing factors of the in-situ disinfection effect are revealed,and theoretical references are provided for the optimal design of the device.[Chinese Medical Equipment Journal,2025,46(9):22-27]
9.Role of CHMP4C in gastric cancer development through regulating necroptosis and its action mechanism
Qi-ning GUO ; Ya-ping LI ; Li PEI ; Long-chen YU ; Zheng-dong LUO ; Rui ZHAO ; Zhong-fang NIU ; Xin ZHANG
Chinese Journal of Current Advances in General Surgery 2025;28(2):125-133
Objective:Exploring the role and mechanism of CHMP4C in regulating necroptosis during gastric can-cer development and progression.Method:The expression of CHMP4C in pan-cancer was analyzed by bioinformatics methods,and the expression of CHMP4C was detected in human normal gastric epithelial cells and GC cell lines by RT-qPCR and Western blot.Overexpression or knockdown of CHMP4C was performed in GC cell lines,and the effects of CHMP4C on the growth and proliferation of GC cells were detected using CCK-8 and clone formation assays.The CCK-8 experiment and Hoechst/PI double staining experiment were used to detect the changes in GC cell mortality and PI positive cell ratio after treatment with the necroptsis inducer TSZ or inhibitor necrostatin-1(Nec-1).Western blot assay was used to detect the protein and phosphorylation levels of RIPK1,RIPK3,and MLKL in GC cells.Result:CHMP4C was upregulated in GC tissues and cells.The CCK-8 and clone formation experiments showed that overex-pression of CHMP4C significantly improved the proliferation ability and colony formation efficiency of GC cells,while knockdown of CHMP4C significantly weakened GC cells.Moreover,the results of CCK-8 and Hoechst 33342/PI double staining experiments showed that upregulated CHMP4C could inhibit TSZ induced GC cell death;Nec-1 can reverse the decrease in GC cell viability caused by CHMP4C knockdown.Western blot experiment showed that the levels of p-RIPK1,p-RIPK3,and p-MLKL were significantly decreased in overexpressing cells,while they were increased in knockdown cells.After treatment with Nec-1,the expression levels of these three proteins decreased in knockdown cells.Conclusion:CHMP4C may promote GC progression by negatively regulating necroptosis through inhibiting the phosphorylation of the RIPK1/RIPK3/MLKL signaling pathway,suggesting that it is expected to be a potential target for GC therapy.
10.Feasibility study of using clinical trial individual-level data sample bank as external control to support drug and device development:taking transcatheter aortic valve replacement device as an example
Xiao-ying LIN ; Chi-lie DANZENG ; Duo-er WANG ; Ying-xuan ZHU ; Ye LU ; Fan GAO ; Yuan-xin LI ; Meng-zhu SU ; Zi-long ZHANG ; Min CHEN ; Qi-ze LI ; Ru JIANG ; Yan-yan ZHAO ; Yang WANG
Chinese Journal of Interventional Cardiology 2025;33(8):459-466
Objective To explore the feasibility and corresponding implementation methods of constructing a sample resource bank based on individual-level data of completed clinical trials and using it to construct external controls for drug/device clinical trials.Methods Taking the pre-marketing clinical trial of transcatheter active valve replacement(TAVR)for the treatment of aortic valve stenosis as an example,the individual-level databases of multiple trials were standardized to form a sample bank.The original data of any trial in the sample bank were selected as the experimental group,and the remaining samples were selected as the control group.The potential confounding was handled by using the propensity score matching and stratification methods to clarify the process of constructing external controls based on the sample bank of individual-level data of clinical trials.Results This study included individual-level data of single-group trials of 4 TAVR devices,with a total of 569 subjects(59.2%male).The number of subjects in Trials 1 to 4 was 120,120,163,and 166,respectively.Propensity score matching enabled the matching of 113,117,125,and 147 subjects with comparable or similar characteristics from individual-level data from other trials,respectively,demonstrating a high matching success rate.The PS score distribution plot after stratification showed that the proportions of subjects in the experimental and control groups in strata 1 to 5 in scheme 1 were 4/103,11/103,22/92,32/87,and 51/64,respectively.For all constructed external controlled trials,a certain number of control samples with similar baseline characteristics to the experimental groups were distributed within each propensity score stratum.The results of the simulation test also reflected the potential differences between different devices in the 12-month all-cause mortality rate.Conclusions The sample bank constructed with individual-level data from clinical trials,as a high-quality data source,can serve as a source of external control for single-arm trials in the same field,and as a useful supplement to the external control scenario of real-world evidence to support drug and device development.At the same time,targeted research on research methods and bias control measures in related fields is also needed.

Result Analysis
Print
Save
E-mail