1.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
2.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
3.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
4.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
5.Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment
Shen CHEN ; Chao XIE ; Xiaoxi LONG ; Xianwei WANG ; Xudong LI ; Peng LIU ; Jiabin LIU ; Zuyong WANG
Tissue Engineering and Regenerative Medicine 2025;22(2):195-210
BACKGROUND:
Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.
METHODS:
A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring. The impact of process parameters on fiber size and morphology was investigated. The structure and functions of the scaffolds were evaluated through material characterization and assessments of cellular biocompatibility.
RESULTS:
The new setup enabled controlled deposition of fibers in different designed orientations. The fabricated small-diameter vascular scaffolds consisted of an inner layer of longitudinally oriented fibers and an outer layer of circumferentially oriented fibers (L + C vascular scaffold). Key parameters, including rotational speed, the utilization of the auxiliary electrode, and top-to-collector distance (TCD) significantly influenced fiber orientation. Additionally, voltage, TCD, feed rate, needle size, auxiliary electrode and collector-auxiliary electrode distance affected fiber diameter and distribution. Mechanical advantages and improved surface wettability of L + C vascular scaffold were confirmed through tensile testing and water contact angle. Cellular experiments indicated that L + C vascular scaffold facilitated cell adhesion and proliferation, with human umbilical vein endothelial cells and smooth muscle cells attaching and elongating along the fiber direction of the inner and outer layer, respectively.
CONCLUSION
This study demonstrated the feasibility of fabricating fiber-aligned, thick-walled vascular scaffolds using a modified electrospinning setup. The findings provided insights into how the auxiliary electrode, specific collector influenced fiber deposition, potentially advancing biomimetic vascular scaffold engineering.
6.Effectiveness of innervated medial plantar flap for reconstruction of soft tissue defects following foot tumor resection.
Wenchao ZHANG ; Luqi GUO ; Yan HAO ; Liangya WANG ; Chao ZHANG ; Yun WANG ; Jiuzuo HUANG ; Ang ZENG ; Xiao LONG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1086-1090
OBJECTIVE:
To evaluate the effectiveness of the innervated medial plantar flap for reconstructing soft tissue defects, particularly in the weight-bearing zone, after resection of foot tumors.
METHODS:
A retrospective analysis was conducted on 12 patients with malignant skin and soft tissue tumors of the foot treated between October 2023 and December 2024. The cohort included 8 males and 4 females, aged 42-67 years (mean, 57.5 years). Tumor types comprised malignant melanoma (5 cases), squamous cell carcinoma (4 cases), arsenical keratosis (2 cases), and tumor-induced osteomalacia (1 case). Soft tissue defects located in the heel weight-bearing region in 10 cases and non-weight-bearing ankle region in 2 cases, with defect sizes ranging from 4.0 cm×3.0 cm to 6.0 cm×4.0 cm. Preoperative photon-counting CT angiography (PC-CTA) was performed to assess the medial plantar artery and its perforators. All patients underwent radical tumor resection with confirmed negative margins. The resulting defects were reconstructed using a innervated medial plantar flap incorporating sensory branches of the medial plantar nerve. The flap donor site was covered with a split-thickness skin graft harvested from the ipsilateral inguinal region.
RESULTS:
The operation was successfully completed in all 12 patients. All flaps survived completely without vascular compromise, partial necrosis, or total loss. Incisions healed primarily without dehiscence or infection. Minor skin graft necrosis occurred at the donor site in 3 patients, which healed within 2-3 weeks with routine dressing changes. No donor site complication (e.g., tendon or nerve injury) occurred. Patients were followed up 2-16 months (mean, 10.3 months). At last follow-up, there was no tumor recurrence. Flaps exhibited good color and texture match with surrounding tissue, restored sensation, and all feet achieved normal weight-bearing activity.
CONCLUSION
The innervated medial plantar flap, precisely designed based on PC-CTA localization, provides reliable blood supply and effective sensory restoration. It is an ideal method for reconstructing soft tissue defects after foot tumor resection, especially in the heel weight-bearing region.
Humans
;
Male
;
Middle Aged
;
Female
;
Plastic Surgery Procedures/methods*
;
Adult
;
Aged
;
Retrospective Studies
;
Soft Tissue Neoplasms/surgery*
;
Surgical Flaps/blood supply*
;
Foot/surgery*
;
Skin Neoplasms/surgery*
;
Soft Tissue Injuries/surgery*
;
Carcinoma, Squamous Cell/surgery*
;
Treatment Outcome
;
Skin Transplantation/methods*
;
Melanoma/surgery*
7.Clinical efficacy of minimally invasive tendon blade technique in the treatment of moderate and severe gluteal muscle contracture.
Jia-Kai GAO ; Tao-Ran WANG ; Long BI ; Xiao-Chao CHEN ; Yan-Wu LIU ; Yao-Ping WU ; Xiang HE ; Zhi-Xia NIU
China Journal of Orthopaedics and Traumatology 2025;38(4):420-423
OBJECTIVE:
To investigate the clinical effect of minimally invasive technique in the treatment of moderate and severe gluteal muscle contracture.
METHODS:
A retrospective study was conducted on 85 patients (170 sides) with bilateral gluteal muscle contracture admitted from January 2016 to December 2019. All patients were treated with minimally invasive release of tendon knife. There were 32 males and 53 females, ranging in age from 15 to 37 years old, with an average age of (22.3±6.3) years old. Operation time, intraoperative blood loss, incision length, first postoperative ambulation time, complication rate, recurrence rate, and Harris hip score (HHS) were analyzed and evaluated.
RESULTS:
The average follow-up time was (16.2±4.6) months, ranging from 12 to 30 months. The operation time ranged from 7 to 15 min, with an average of (10.2±3.1) min. Intraoperative blood loss ranged from 2 to 20 ml, with an average of (8.4±2.2) ml. The incision length ranged from 0.6 to 2.0 cm, with an average of (0.8±0.3) cm. The time to postoperative ambulation ranged from 12 to 28 h, with an average of (20.0±3.2) h. All patients achieved primary wound healing without sciatic nerve injury or recurrence. HHS hip function scores ranged from 90 to 98, with an average score of (96.2±1.4). Complications included intraoperative tendon blade tip fracture in two cases (removed under fluoroscopic guidance) and subcutaneous hematoma in three cases-two resolved with compression and one with open evacuation.. Twenty-nine patients exhibited transient swaying gait postoperatively, of which 24 patients returned to normal after 4 weeks and 5 patients returned to normal after 6 weeks.
CONCLUSION
Minimally invasive tendon blade release is a safe and effective technique for treating gluteal muscle contracture, offering minimal trauma, rapid recovery, and excellent cosmetic and functional outcomes. However, it exhibits a low risk of blade tip fracture and sciatic nerve injury, warranting experienced surgical handling.
Humans
;
Male
;
Female
;
Adult
;
Minimally Invasive Surgical Procedures/methods*
;
Adolescent
;
Retrospective Studies
;
Buttocks/surgery*
;
Young Adult
;
Contracture/surgery*
;
Tendons/surgery*
;
Muscle, Skeletal/surgery*
8.Exploring urban versus rural disparities in atrial fibrillation: prevalence and management trends among elderly Chinese in a screening study.
Wei ZHANG ; Yi CHEN ; Lei-Xiao HU ; Jia-Hui XIA ; Xiao-Fei YE ; Wen-Yuan-Yue WANG ; Xin-Yu WANG ; Quan-Yong XIANG ; Qin TAN ; Xiao-Long WANG ; Xiao-Min YANG ; De-Chao ZHAO ; Xin CHEN ; Yan LI ; Ji-Guang WANG ; FOR THE IMPRESSION INVESTIGATORS AND COORDINATORS
Journal of Geriatric Cardiology 2025;22(2):246-254
BACKGROUND:
Atrial fibrillation (AF) is a common cardiac arrhythmia in the elderly. This study aimed to evaluate urban-rural disparities in its prevalence and management in elderly Chinese.
METHODS:
Consecutive participants aged ≥ 65 years attending outpatient clinics were enrolled for AF screening using handheld single-lead electrocardiogram (ECG) from April 2017 to December 2022. Each ECG rhythm strip was reviewed from the research team. AF or uninterpretable single-lead ECGs were referred for 12-lead ECG. Primary study outcome comparison was between rural and urban areas for the prevalence of AF. The Student's t-test was used to compare mean values of clinical characteristics between rural and urban participants, while the Pearson's chi-square test was used to compare between-group proportions. Multivariate stepwise logistic regression analysis was performed to estimate the association between AF and various patient characteristics.
RESULTS:
The 29,166 study participants included 13,253 men (45.4%) and had a mean age of 72.2 years. The 7073 rural participants differed significantly (P ≤ 0.02) from the 22,093 urban participants in several major characteristics, such as older age, greater body mass index, and so on. The overall prevalence of AF was 4.6% (n = 1347). AF was more prevalent in 7073 rural participants than 22,093 urban participants (5.6% vs. 4.3%, P < 0.01), before and after adjustment for age, body mass index, blood pressure, pulse rate, cigarette smoking, alcohol consumption and prior medical history. Multivariate logistic regression analysis identified overweight/obesity (OR = 1.35, 95% CI: 1.17-1.54) in urban areas and cigarette smoking (OR = 1.62, 95% CI: 1.20-2.17) and alcohol consumption (OR = 1.42, 95% CI: 1.04-1.93) in rural areas as specific risk factors for prevalent AF. In patients with known AF in urban areas (n = 781) and rural areas (n = 338), 60.6% and 45.9%, respectively, received AF treatment (P < 0.01), and only 22.4% and 17.2%, respectively, received anticoagulation therapy (P = 0.05).
CONCLUSIONS
In China, there are urban-rural disparities in AF in the elderly, with a higher prevalence and worse management in rural areas than urban areas. Our study findings provide insight for health policymakers to consider urban-rural disparity in the prevention and treatment of AF.
9.Multiple biomarkers risk score for accurately predicting the long-term prognosis of patients with acute coronary syndrome.
Zhi-Yong ZHANG ; Xin-Yu WANG ; Cong-Cong HOU ; Hong-Bin LIU ; Lyu LYU ; Mu-Lei CHEN ; Xiao-Rong XU ; Feng JIANG ; Long LI ; Wei-Ming LI ; Kui-Bao LI ; Juan WANG
Journal of Geriatric Cardiology 2025;22(7):656-667
BACKGROUND:
Biomarkers-based prediction of long-term risk of acute coronary syndrome (ACS) is scarce. We aim to develop a risk score integrating clinical routine information (C) and plasma biomarkers (B) for predicting long-term risk of ACS patients.
METHODS:
We included 2729 ACS patients from the OCEA (Observation of cardiovascular events in ACS patients). The earlier admitted 1910 patients were enrolled as development cohort; and the subsequently admitted 819 subjects were treated as validation cohort. We investigated 10-year risk of cardiovascular (CV) death, myocardial infarction (MI) and all cause death in these patients. Potential variables contributing to risk of clinical events were assessed using Cox regression models and a score was derived using main part of these variables.
RESULTS:
During 16,110 person-years of follow-up, there were 238 CV death/MI in the development cohort. The 7 most important predictors including in the final model were NT-proBNP, D-dimer, GDF-15, peripheral artery disease (PAD), Fibrinogen, ST-segment elevated MI (STEMI), left ventricular ejection fraction (LVEF), termed as CB-ACS score. C-index of the score for predication of cardiovascular events was 0.79 (95% CI: 0.76-0.82) in development cohort and 0.77 (95% CI: 0.76-0.78) in the validation cohort (5832 person-years of follow-up), which outperformed GRACE 2.0 and ABC-ACS risk score. The CB-ACS score was also well calibrated in development and validation cohort (Greenwood-Nam-D'Agostino: P = 0.70 and P = 0.07, respectively).
CONCLUSIONS
CB-ACS risk score provides a useful tool for long-term prediction of CV events in patients with ACS. This model outperforms GRACE 2.0 and ABC-ACS ischemic risk score.
10.Qingda Granule Attenuates Hypertension-Induced Cardiac Damage via Regulating Renin-Angiotensin System Pathway.
Lin-Zi LONG ; Ling TAN ; Feng-Qin XU ; Wen-Wen YANG ; Hong-Zheng LI ; Jian-Gang LIU ; Ke WANG ; Zhi-Ru ZHAO ; Yue-Qi WANG ; Chao-Ju WANG ; Yi-Chao WEN ; Ming-Yan HUANG ; Hua QU ; Chang-Geng FU ; Ke-Ji CHEN
Chinese journal of integrative medicine 2025;31(5):402-411
OBJECTIVE:
To assess the efficacy of Qingda Granule (QDG) in ameliorating hypertension-induced cardiac damage and investigate the underlying mechanisms involved.
METHODS:
Twenty spontaneously hypertensive rats (SHRs) were used to develope a hypertension-induced cardiac damage model. Another 10 Wistar Kyoto (WKY) rats were used as normotension group. Rats were administrated intragastrically QDG [0.9 g/(kg•d)] or an equivalent volume of pure water for 8 weeks. Blood pressure, histopathological changes, cardiac function, levels of oxidative stress and inflammatory response markers were measured. Furthermore, to gain insights into the potential mechanisms underlying the protective effects of QDG against hypertension-induced cardiac injury, a network pharmacology study was conducted. Predicted results were validated by Western blot, radioimmunoassay immunohistochemistry and quantitative polymerase chain reaction, respectively.
RESULTS:
The administration of QDG resulted in a significant decrease in blood pressure levels in SHRs (P<0.01). Histological examinations, including hematoxylin-eosin staining and Masson trichrome staining revealed that QDG effectively attenuated hypertension-induced cardiac damage. Furthermore, echocardiography demonstrated that QDG improved hypertension-associated cardiac dysfunction. Enzyme-linked immunosorbent assay and colorimetric method indicated that QDG significantly reduced oxidative stress and inflammatory response levels in both myocardial tissue and serum (P<0.01).
CONCLUSIONS
Both network pharmacology and experimental investigations confirmed that QDG exerted its beneficial effects in decreasing hypertension-induced cardiac damage by regulating the angiotensin converting enzyme (ACE)/angiotensin II (Ang II)/Ang II receptor type 1 axis and ACE/Ang II/Ang II receptor type 2 axis.
Animals
;
Drugs, Chinese Herbal/therapeutic use*
;
Hypertension/pathology*
;
Renin-Angiotensin System/drug effects*
;
Rats, Inbred SHR
;
Oxidative Stress/drug effects*
;
Male
;
Rats, Inbred WKY
;
Blood Pressure/drug effects*
;
Myocardium/pathology*
;
Rats
;
Inflammation/pathology*

Result Analysis
Print
Save
E-mail